LRLisa Rosenqvist

Lisa Rosenqvist

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lisa Rosenqvist has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Recent Measurements at a GIC Hotspot in Sweden: Reinterpretation and New Insights into Impacts and Causes

    by Alice Vivianne Linnea Wallner, Andrew P. Dimmock, Martin Pettersson, Vanina Lanabere, Stephan Christoph Buchert, Johan Setréus, Andreas Johlander, Lisa Rosenqvist, Emiliya Yordanova, Elena Marshalko, et al.

    Long-term measurements of geomagnetically induced currents (GICs) in power grids are rare, particularly in Sweden. This means that knowledge of GIC levels and impacts is usually based on modeling the geoelectric field and estimating GICs, which can have varying accuracy, making the diagnosis of GIC impacts difficult. However, following the power grid disturbance during the Gannon storm in May 2024, the Swedish power grid operator, Svenska Kraftnät, started measuring GIC in the most GIC-affected transformer in the Swedish power grid, located in Karlshamn, southern Sweden. Elevated levels of GIC (relative to quiet periods) during a recent G4 geomagnetic storm on 19-22 January 2026 were captured by this measurement. In this study, we use the GIC measurement from January to evaluate different ways of modeling GIC at this specific location. Using the best-performing models and previously unpublished harmonic recordings, we revisit the power grid impact from the Gannon storm in May 2024 to provide valuable new insights into the circumstances around the disturbance. Lastly, we use the same model to investigate the levels of GIC over 11 years and compare them to simulations of rare and strong space weather impacts. This study shows that GIC measurements from one event can significantly improve the accuracy of modeled GICs during other events for which measurements are unavailable, given that the power grid configuration does not change significantly. Improving modeling of GICs in the power grid is an important step to understanding and mitigating one of the most

  • Top Cited Papers
    Open Access

    The Geomagnetic Storm on 10–12 May 2024 and Its Effect on the Swedish Power Grid

    by A. V. L. Wallner, A. P. Dimmock, V. Lanabere, A. Johlander, S. Molenkamp Venholen, A. Viljanen, L. Juusola, L. Rosenqvist, J. Setréus, E. Yordanova, et al.

    On 10–12 May 2024, at least five interplanetary coronal mass ejections (ICMEs) arrived at Earth and caused the strongest geomagnetic storm in over 20 years. During this geomagnetic storm, a disturbance occurred in a transformer in southern Sweden, causing a drop in power supply in the power line connecting Sweden and Poland. The power grid operator confirm geomagnetically induced currents (GICs) were the cause. The purpose of this study is to investigate the circumstances around and the cause of this disturbance, as well as analyzing if the effect in southern Sweden could have been different had the first ICME arrived earlier or later. Using satellite data, ground magnetometer measurements and a ground conductivity model over Fennoscandia, we perform this analysis from the solar wind down to the induced geoelectric field. Further, we compare this event to two previous disturbances in the same power line caused by GICs. The results of this study show that the disturbance occurred at a time of turbulent solar wind conditions and the merging of two ionospheric current structures. However, the disturbance did not occur at the time of peak induced geoelectric field throughout the storm, at the location of the disturbance. From the timing analysis, we see that most magnetic local time sectors along the same geomagnetic latitude, experienced similar magnitudes of geoelectric field as a result of the storm. The results suggest that there is a high probability the disturbance would have occurred even if the ICME would have arrived at a different time.


  • Open Access

    The geomagnetic storm on May 10-12 2024 and its effect on the Swedish power grid

    by Alice Vivianne Linnea Wallner, Andrew P. Dimmock, Vanina Carina Lanabere, Andreas Johlander, Sven Molenkamp, Ari Viljanen, Liisa Juusola, Lisa Rosenqvist, Johan Setréus, Emiliya Yordanova, et al.

    On May 10 2024, the first of at least five interplanetary coronal mass ejections (ICMEs) arrived at Earth and caused the strongest geomagnetic storm in over twenty years. During this geomagnetic storm, a disturbance occurred in a transformer in southern Sweden, causing a drop in power supply in the power line connecting Sweden and Poland. The power grid operator confirm geomagnetically induced currents (GICs) were the cause. The purpose of this study is to investigate the circumstances around and the cause of this disturbance, as well as analyzing if the effect in southern Sweden could have been different had the first ICME arrived earlier or later. Using satellite data, ground magnetometer measurements and a ground conductivity model over Fennoscandia, we perform this analysis from the solar wind down to the induced geoelectric field. Further, we compare this event to two previous disturbances in the same power line caused by GICs. The results of this study show that the disturbance occurred at a time of turbulent solar wind conditions and the merging of two ionospheric current structures. However, the disturbance did not occur at the time of peak induced geoelectric field throughout the storm, at the location of the disturbance. From the timing analysis, we see that most magnetic local time sectors along the same geomagnetic latitude, experienced similar levels of geoelectric field as a result of the storm. This indicates that the disturbance would have occurred regardless of the arrival time of the first ICME, however at a different time.

  • Open Access

    A Novel Approach for Evaluating GIC Impacts in the Swedish Power Grid

    by L. Rosenqvist, A. Johlander, S. Molenkamp, A. P. Dimmock, J. Setréus, V. Lanabere

    The dynamic behavior of the Sun and its interaction with the magnetosphere and ionosphere can cause rapid variations in the geomagnetic field at ground level, geomagnetically induced currents (GICs) flowing through long grounded conductors. The most severe impacts of GICs include power grid disruptions and can, in extreme cases, cause widespread power blackouts. Thus, it is important to investigate GICs to understand the impacts, improve predictions, and develop appropriate mitigation measures. A comprehensive list of disturbances reported in the Swedish power grid between 1999 and June 2024 is evaluated in collaboration with the Swedish authority responsible for the electrical transmission system, Svenska Kraftnät. Using a regional modeling capability of geoelectric fields in Sweden and a simplified yet representative equivalent circuit model of the national power grid, the resulting GICs in the earthing nodes of the network are calculated. The calculated GICs are cross‐correlated with the power grid disturbances to determine which events may have been caused by space weather. By disregarding events with known causes (lightning, fallen trees, equipment failures, etc.), events associated with significant voltage deviations are identified as likely GIC‐related disturbances. While it is not possible to pinpoint the exact location of the impact in the grid or the absolute magnitude of the GICs, both dependent on the accuracy of the grid circuit model, the maximum modeled GICs overlap with several previously uncategorized disturbances. These results highlight the value of the unique collaboration between the scientific community and the power grid operator in Sweden.


  • Open Access

    Investigating the Trip of a Transformer in Sweden During the 24 April 2023 Storm

    by A. P. Dimmock, V. Lanabere, A. Johlander, L. Rosenqvist, E. Yordanova, S. Buchert, S. Molenkamp, J. Setréus

    Geomagnetically Induced Currents are unwanted currents that flow in large ground‐based conductive infrastructure and are a significant threat to bulk power grids. This susceptibility is increased at high latitudes due to the larger amplitude geomagnetic disturbances caused by the strong and dynamic auroral electrojet currents. In Sweden, there has been a record of disturbances connected to geomagnetically induced currents; the most documented was a blackout in Malmö, a city in southern Sweden, on 30 October 2003. However, on 24 April 2023, there was a transformer trip in the Bandsjö substation (near Sundsvall) around the time of enhanced space weather. In this paper, we investigate this event by studying the solar wind properties as well as geomagnetic disturbances. The study shows evidence that the transformer trip was caused by a strong geomagnetic disturbance in the morning sector. This was triggered by a high‐pressure sub‐structure within the interplanetary coronal mass ejection cloud, preceded by 2 hr of strong southward interplanetary magnetic field. Additionally, analysis of multiple ground magnetometers shows that the geomagnetic impact was highly spatially structured.


  • Open Access

    Characterizing the distribution of extreme geoelectric field events in Sweden

    by Vanina Lanabere, Andrew P. Dimmock, Lisa Rosenqvist, Ari Viljanen, Liisa Juusola, Andreas Johlander

    Historically, Sweden has reported several impacts on transformers and transmission lines related to geomagnetically induced currents (GICs) that develop during strong space weather events. GICs are driven by the geoelectric field (E), and their intensity depends on various factors, including the lithology conductivity and the rate of change of the Earth’s magnetic field. The purpose of this study is to perform an extreme value (EV) analysis of the E magnitude at six different latitudes in Sweden and to express the maximum |E| that might be observed in 10, 50, and 100 years. We analyzed 10-s E data in Sweden, obtained from a 1-D model. This model incorporates 10-s geomagnetic measurements from the IMAGE network and the vertical Earth’s ground electrical conductivity in Sweden, extracted from a 3-D conductance map for the Fennoscandian region. Extreme E events tend to occur in clusters around geomagnetic disturbances (substorms and geomagnetic storms). Therefore, we applied two different methods to decluster the data. After declustering, Generalized Pareto (GP) distributions were fitted to the remaining extreme events that exceeded the 99.5th percentile. The EV analysis indicates that the shape parameter of the GP distribution depends on latitude. This implies that at higher geographic latitudes (64.52–68.02°N) the distribution decreases faster toward zero than at lower latitudes (58.26–62.25°N). As a result the expected maximum |E| in 100 years in central Sweden ranges between 4.0 and 8.5 V/km, while at higher latitudes, it ranges between 2.0 and 2.5 V/km, similar to the modeled geoelectric field values during the Halloween event in October 2003. In particular, around 60.50°N the distribution of extreme events exhibits the heaviest tail. When we additionally consider the effect of conductivity, the region of west Sweden around 60.50°N exhibits the largest expected maximum in 100 years with a value around 8.5 V/km. This is three times larger than the maximum modeled |E| at that latitude.


  • Open Access

    Analysis of the Geoelectric Field in Sweden Over Solar Cycles 23 and 24: Spatial and Temporal Variability During Strong GIC Events

    by V. Lanabere, A. P. Dimmock, L. Rosenqvist, L. Juusola, A. Viljanen, A. Johlander, E. Odelstad

    Geomagnetic storms can produce large perturbations on the Earth magnetic field. Through complex magnetosphere‐ionosphere coupling, the geoelectric field (E) and geomagnetic field (B) are highly perturbed. The E is the physical driver of geomagnetically induced currents. However, a statistical study of the E in Sweden has never been done before. We combined geomagnetic data from the International Monitor for Auroral Geomagnetic Effects network in Northern Europe with a 3‐D structure of Earth's electrical conductivity in Sweden as the input of a 1‐D model to compute the E between 2000 and 2018. Northwestern Sweden presents statistically larger E magnitudes due to larger |dB/dt| variations in the north than in the south of Sweden and relative lower conductivity in the west compared to central and eastern Sweden. In contrast, the 15 strongest daily maximum |E| events present more frequently a maximum magnitude in central Sweden (62.25°N) and their relative strengths are not the same for all latitudes. These results highlight the different regional response to geomagnetic storms, which can be related to ground conductivity variability and the complex magnetosphere‐ionosphere coupling mechanisms.


  • Open Access

    Distribution and Occurrence Frequency of dB/dt Spikes During Magnetic Storms 1980–2020

    by A. Schillings, L. Palin, H. J. Opgenoorth, M. Hamrin, L. Rosenqvist, J. W. Gjerloev, L. Juusola, R. Barnes

    The physical magnetospheric cause for geomagnetically induced currents (GICs) are rapid time‐varying magnetic fields (dB/dt), which occur mainly during magnetic substorms and storms. When, where and why exactly such rapid dB/dt may occur is insufficiently understood. We investigated all storms since 1980 and analyzed the negative and positive dB/dt spikes (>|500| nT/min) in the north and east component using a worldwide coverage (SuperMAG). Our analysis confirmed the existence of two dB/dt spikes “hotspots” located in the pre‐midnight and in the morning magnetic local time sector, independently of the geographic location of the stations. The associated physical phenomena are probably substorm current wedge onsets and westward traveling surges (WTS) in the evening sector, and wave‐ or vortex‐like current flows in the morning sector known as Omega bands. We observed a spatiotemporal evolution of the negative northern dB/dt spikes. The spikes initially occur in the pre‐midnight sector, and then develop in time toward the morning sector. This spatiotemporal sequence is correlated with bursts in the AE index, and can be repeated several times throughout a storm. Finally, we investigated the peak value of Dst and AE during the storm period in comparison with the dB/dt spike occurrence frequency, we did not find any correlation. This result implies that a moderate storm with many spikes can be as (or more) dangerous for ground‐based infrastructures than a major storm with fewer dB/dt spikes. Our findings regarding the physical causes and characteristics of dB/dt spikes may help to improve the GIC forecast for the affected regions.


  • Open Access

    3D Modeling of Geomagnetically Induced Currents in Sweden—Validation and Extreme Event Analysis

    by L. Rosenqvist, T. Fristedt, A. P. Dimmock, P. Davidsson, R. Fridström, J. O. Hall, L. Hesslow, J. Kjäll, M. Yu Smirnov, D. Welling, et al.

    Rosenqvist and Hall (2019), https://agupubs.onlinelibrary.wiley.com/doi/abs/10.1029/2018SW002084 developed a proof‐of‐concept modeling capability that incorporates a detailed 3D structure of Earth's electrical conductivity in a geomagnetically induced current estimation procedure (GIC‐SMAP). The model was verified based on GIC measurements in northern Sweden. The study showed that southern Sweden is exposed to stronger electric fields due to a combined effect of low crustal conductivity and the influence of the surrounding coast. This study aims at further verifying the model in this region. GIC measurements on a power line at the west coast of southern Sweden are utilized. The location of the transmission line was selected to include coast effects at the ocean‐land interface to investigate the importance of using 3D induction modeling methods. The model is used to quantify the hazard of severe GICs in this particular transmission line by using historic recordings of strong geomagnetic disturbances. To quantify a worst‐case scenario GICs are calculated from modeled magnetic disturbances by the Space Weather Modeling Framework based on estimates for an idealized extreme interplanetary coronal mass ejection. The observed and estimated GIC based on the 3D GIC‐SMAP procedure in the transmission line in southern Sweden are in good agreement. In contrast, 1D methods underestimate GICs by about 50%. The estimated GICs in the studied transmission line exceed 100 A for one of 14 historical geomagnetic storm intervals. The peak GIC during the sudden impulse phase of a “perfect” storm exceeds 300 A but depends on the locality of the station as the interplanetary magnetic cloud hits Earth.


  • Open Access

    Distribution and occurrence frequency of dB/dt spikes during magnetic storms 1980-2019

    by Audrey Schillings, Laurianne Palin, Hermann Opgenoorth, Maria Hamrin, Lisa Rosenqvist, Jesper W. Gjerloev, Liisa Juusola, Robin J. Barnes

    Geomagnetically induced currents or GICs are signatures of a rapidly time-varying magnetic field (dB/dt) and occur mainly during substorms and storms. When, where and why exactly GICs may occur, is still vague. Thus, we investigated storms for the last 40 years (from 1980 with a storm-list created by W.T. Walach) and analyzed the negative and positive dB/dt spikes (threshold of 500 nT/min) in the north and east component using a worldwide coverage (SuperMAG). Our analysis confirmed the existence of two dB/dt spikes “hotspots” located in the pre-midnight and in the morning MLT sector, independently of the geographic location of the stations. The associated physical ionospheric phenomena are most probably substorm current wedge (SCW) onsets and westward travelling surges (WTS) in the evening sector, and wave- or vortex-like current flows in Omega bands in the morning sector. Additionally, we observed a spatio-temporal evolution of the negative northern dB/dt spikes. The spikes initially occur in the pre-midnight sector, and then develop in time towards the morning sector. This spatio-temporal sequence is correlated with bursts in the AE index, and can be repeated several times throughout a storm. Finally, we investigated the intensity (Dst and AE) of the storms compared to the number of dB/dt spikes, but we did not find any correlation. This result implies that moderate storm with many spikes can be as (or more) dangerous for ground-based infrastructures than a major storm with fewer dB/dt spikes. Our findings may help to improve the GICs forecast to accurately predict dB/dt spikes.