MMMichael A. J. Moser

Michael A. J. Moser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael A. J. Moser has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Computational Modeling With Phantom-Tissue Validation of Gold-Nanorod-Enhanced Laser Ablation of Prostate Cancer

    by Huishan Liang, Zhiqin Qian, Hanwei Zhang, Yigang Luo, Michael A. J. Moser, Wenjun Zhang, Bing Zhang

    The purpose of this study was to develop a computational model for the laser ablation (LA) of prostate cancer, enhanced by gold-nanorods (GNRs) in a phantom-tissue system, and to explore the effect of GNRs on the ablation zone. A prostate biomimetic tissue (PBT) was prepared with different volume fractions of GNRs (i.e., 0, 1.68 × 10−7 or 8.40 × 10−7). Specifically, the computational model was built by considering the change of light properties of PBTs with and without GNRs and introducing the dynamic heat source determined by porcine liver carbonization, reported elsewhere. The computational model was then validated by comparing the simulation and the ex vivo LA experiment in terms of three performance indexes, namely, (i) the spatiotemporal temperature distribution, (ii) ablation zone, and (iii) carbonization zone, with the three volume fractions of GNRs in the PBT model, as mentioned above. Except for minor discrepancies found in the carbonization zone, the proposed model agrees with the experimental data. The effect of GNRs on LA was explored with the help of the model, and nine combinations of the laser powers and the volume fractions of GNRs were tested. The result shows that the ablation zone increases with the increase in the volume fraction of GNRs for all three laser powers used. Two conclusions can be drawn: (1) loading GNRs into the tissues may increase the ablation zone of LA, and (2) the proposed computational model is a reliable tool for predicting the spatiotemporal temperature distribution and the ablation zone of the GNR-enhanced LA.


  • Open Access

    Systemic Therapy and Its Surgical Implications in Patients with Resectable Liver Colorectal Cancer Metastases. A Report from the Western Canadian Gastrointestinal Cancer Consensus Conference

    by Shahid Ahmed, Nicholas Bosma, Michael Moser, Shahida Ahmed, Bryan Brunet, Janine Davies, Corinne Doll, Dorie-Anna Dueck, Christina A. Kim, Shuying Ji, et al.

    The Western Canadian Gastrointestinal Cancer Consensus Conference (WCGCCC) convened virtually on 4 November 2021. The WCGCCC is an interactive multi-disciplinary conference attended by health care professionals, including surgical, medical, and radiation oncologists; pathologists; radiologists; and allied health care professionals from across four Western Canadian provinces, British Columbia, Alberta, Saskatchewan, and Manitoba, who are involved in the care of patients with gastrointestinal cancer. They participated in presentation and discussion sessions for the purpose of developing recommendations on the role of systemic therapy and its optimal sequence in patients with resectable metastatic colorectal cancer.

  • Open Access

    Report from the Western Canadian Gastrointestinal Cancer Consensus Conference Virtual Education Series—Transition from Local to System Therapy and Optimal Sequencing of Systemic Therapy for HCC

    by Adnan Zaidi, Shahid Ahmed, Shahida Ahmed, Bryan Brunet, Janine Davies, Corinne Doll, Dorie-Anna Dueck, Vallerie Gordon, Pamela Hebbard, Christina Kim, et al.

    The Western Canadian Gastrointestinal Cancer Consensus Conference (WC-5) convened virtually on 10 February 2021. The WC-5 is an interactive multidisciplinary conference attended by health care professionals from across Western Canada (British Columbia, Alberta, Saskatchewan, and Manitoba) who are involved in the care of patients with gastrointestinal cancer. Surgical, medical, and radiation oncologists; pathologists; radiologists; and allied health care professionals participated in presentation and discussion sessions for the purpose of developing the recommendations presented here. This consensus statement addresses current issues in the management of hepatocellular cancer (HCC). Recommendations have been made for the transition from local to systemic therapy and the optimal sequencing of systemic regimens in the management of HCC.


  • Treatment Planning Optimization in Irreversible Electroporation for Complete Ablation of Variously Sized Cervical Tumors: A Numerical Study

    by Lujia Ding, Michael Moser, Yigang Luo, W.J. (Chris) Zhang, Bing Zhang

    Irreversible electroporation (IRE), a relatively new energy-based tumor ablation technology, has shown itself in the last decade to be able to safely ablate tumors with favorable clinical outcomes, yet little work has been done on optimizing the IRE protocol to variously sized tumors. Incomplete tumor ablation has been shown to be the main reason leading to the local recurrence and thus treatment failure. The goal of this study was to develop a general optimization approach to optimize the IRE protocol for cervical tumors in different sizes, while minimizing the damage to normal tissues. This kind of approach can lay a foundation for future personalized treatment of IRE. First, a statistical IRE cervical tumor death model was built using previous data in our group. Then, a multi-objective optimization problem model was built, in which the decision variables are five IRE-setting parameters, namely, the pulse strength (U), the length of active tip (H), the number of pulses delivered in one round between a pair of electrodes (A), the distance between electrodes (D), and the number of electrodes (N). The domains of the decision variables were determined based on the clinical experience. Finally, the problem model was solved by using nondominated sorting genetic algorithms II (NSGA-II) algorithm to give respective optimal protocol for three sizes of cervical tumors. Every protocol was assessed by the evaluation criterion established in the study to show the efficacy in a more straightforward way. The results of the study demonstrate this approach can theoretically provide the optimal IRE protocol for different sizes of tumors and may be generalizable to other types, sizes, and locations of tumors.


  • Design of a Novel Electrode of Radiofrequency Ablation for Large Tumors: In Vitro Validation and Evaluation

    by Zheng Fang, Micheal A. J. Moser, Edwin Zhang, Wenjun Zhang, Bing Zhang

    In a prior study, we proposed a novel monopolar expandable electrode (MEE) for use in radiofrequency ablation (RFA). The purpose of our work was to now validate and evaluate this electrode using on in vitro experimental model and computer simulation. Two commercially available RF electrodes (conventional electrode (CE) and umbrella electrode (UE)) were used to compare the ablation results with the novel MEE using an in vitro egg white model and in vivo liver tumor model to verify the efficacy of MEE in the large tumor ablation, respectively. The sharp increase in impedance during RFA procedures was taken as the termination of RFA protocols. In the in vitro egg white experiment, the ablation volume of MEE, CE, and UE was 75.3 ± 1.6 cm3, 2.7 ± 0.4 cm3, and 12.4±1.8 cm3 (P < 0.001), respectively. Correspondingly, the sphericity was 88.1±0.9%, 12.9±1.3%, and 62.0 ± 3.0% (P < 0.001), respectively. A similar result was obtained in the in vitro egg white computer simulation. In the liver tumor computer simulation, the volume and sphericity of ablation zone generated by MEE, CE, and UE were 36.6 cm3 and 93.6%, 3.82 cm3 and 16.9%, and 13.5 cm3 and 56.7%, respectively. In summary, MEE has the potential to achieve complete ablation in the treatment of large tumors (>3 cm in diameter) compared to CE and UE due to the larger electrode–tissue interface and more round shape of hooks.


  • Open Access

    An In Vitro Experimental Study of the Pulse Delivery Method in Irreversible Electroporation

    by Bing Zhang, Michael A. J. Moser, Edwin M. Zhang, Jim Xiang, Wenjun Zhang

    The purpose of this study was to investigate the feasibility of generating larger ablation volumes using the pulse delivery method in irreversible electroporation (IRE) using a potato model. Ten types of pulse timing schemes and two pulse repetition rates (1 pulse per 200 ms and 1 pulse per 550 ms) were proposed in the study. Twenty in vitro experiments with five samples each were performed to check the effects on the ablation volumes for the ten pulse timing schemes and two pulse repetition rates. At the two pulse repetition rates (1 pulse per 200 ms and 1 pulse per 550 ms), the largest ablation volumes achieved were 1634.1 mm3± 122.6 and 1828.4 mm3±160.9, respectively. Compared with the baseline approach (no pulse delays), the ablation volume was increased approximately by 62.8% and 22.6% at the repetition rates of 1 pulse per 200 ms and 1 pulse per 550 ms, respectively, using the pulse timing approach (with pulse delays). With the pulse timing approach, the ablation volumes generated at the lower pulse repetition rate were significantly larger than those generated at the higher pulse repetition rate (P < 0.001). For the experiments with one pulse train (baseline approach), the current was 5.2 A±0.4. For the experiments with two pulse trains, the currents were 6.4 A±0.9 and 6.8 A±0.9, respectively (P = 0.191). For the experiments with three pulse trains, the currents were 6.6 A±0.6, 6.9 A±0.6, and 6.5 A±0.6, respectively (P = 0.216). For the experiments with five pulse trains, the currents were 6.6 A±0.9, 6.9 A±0.9, 6.5 A±1.0, 6.5 A±1.0, and 5.7 A±1.2, respectively (P = 0.09). This study concluded that: (1) compared with the baseline approach used clinically, the pulse timing approach is able to increase the volume of ablation; but, the pulse timing scheme with the best performance might be various with the tissue type; (2) the pulse timing approach is still effective in achieving larger ablation volumes when the pulse repetition rate changes; but, the best pulse timing scheme might be different with the pulse repletion rate; (3) the current in the base line approach was significantly smaller than that in the pulse timing approach.