Qihui Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qihui Liu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Hua Zhang
Correspondence to: Prof. Hua Zhang, Department of Metabolic and Bariatric Surgery, The First Affiliated Hospital of Jinan University, Jinan University, No. 613, Huangpu Avenue West, Tianhe District, Guangzhou 510632, Guangdong, China
3 shared publications Xufeng Chen
Department of Stomatology, First Affiliated Hospital, Jinan University, Guangzhou, 510632, PR China
2 shared publicationsZhanpeng Zhang
Department of Dermatology, The first Affiliated Hospital of Jinan University, Guangzhou, Guangdong 510632, PR China
2 shared publicationsBata Wang
Department of Orthopedics, First Affiliated Hospital, Jinan University, Guangzhou, 510632, PR China
1 shared publicationDesheng Wang
School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou, Guangdong 510275, PR China
1 shared publication- Guodong Sun
Department of Orthopedics, First Affliated Hospital, Jinan University, Guangzhou, 510632, People’s Republic of China
1 shared publication
Latest Publications
- 1 March 2022
- Published by Elsevier in Chemosphere
- Vol. 291 (Pt 1) , 132804
Response to comment on “Occurrence of neonicotinoid insecticides and their metabolites in tooth samples collected from south China: Associations with periodontitis”
- 1 March 2022
- Published by Elsevier in Chemosphere
- Vol. 291 (Pt 1) , 132804
Response to comment on “Occurrence of neonicotinoid insecticides and their metabolites in tooth samples collected from south China: Associations with periodontitis”
- 1 February 2021
- Published by Elsevier in Chemosphere
- Vol. 264, 128498
Occurrence of neonicotinoid insecticides and their metabolites in tooth samples collected from south China: Associations with periodontitis
- 1 February 2021
- Published by Elsevier in Chemosphere
- Vol. 264, 128498
Occurrence of neonicotinoid insecticides and their metabolites in tooth samples collected from south China: Associations with periodontitis
- Open Access
- 5 December 2018
- Published by Springer Nature in Discover Nano
- Vol. 13 (1) , 397
Plasmonic ELISA for Sensitive Detection of Disease Biomarkers with a Smart Phone-Based Reader
Serum myoglobin is one of the earliest markers for the diagnosis of acute myocardial infarction. It is, therefore, critical to develop a point-of-care testing technology for myoglobin detection. In this work, we reported a sensitive plasmonic immunoassay-based on enzyme-mediated localized surface plasmon resonance change of gold nanorods for the point-of-care testing detection of myoglobin. In addition, we developed a novel plasmonic immunoassay reader using the ambient light sensor of smart phone to increase the accessibility and utility of the plasmonic immunoassay. The linear detection range of gold nanorods-based plasmonic immunoassay for myoglobin detection was 0.1–1000 ng mL−1 and the limit of detection was 0.057 ng mL−1. Myoglobin in serum samples was also analyzed by the plasmonic immunoassay. The results were significantly correlated with those of conventional enzyme-linked immunosorbent assay. The plasmonic immunoassay, coupled with smart phone-based reader, could be widely used for point-of-care testing application of acute myocardial infarction, especially in the regions with limited technological resources.
- 5 December 2018
- Published by Springer Nature in Discover Nano
- Vol. 13 (1) , 397
Open AccessPlasmonic ELISA for Sensitive Detection of Disease Biomarkers with a Smart Phone-Based Reader
Serum myoglobin is one of the earliest markers for the diagnosis of acute myocardial infarction. It is, therefore, critical to develop a point-of-care testing technology for myoglobin detection. In this work, we reported a sensitive plasmonic immunoassay-based on enzyme-mediated localized surface plasmon resonance change of gold nanorods for the point-of-care testing detection of myoglobin. In addition, we developed a novel plasmonic immunoassay reader using the ambient light sensor of smart phone to increase the accessibility and utility of the plasmonic immunoassay. The linear detection range of gold nanorods-based plasmonic immunoassay for myoglobin detection was 0.1–1000 ng mL−1 and the limit of detection was 0.057 ng mL−1. Myoglobin in serum samples was also analyzed by the plasmonic immunoassay. The results were significantly correlated with those of conventional enzyme-linked immunosorbent assay. The plasmonic immunoassay, coupled with smart phone-based reader, could be widely used for point-of-care testing application of acute myocardial infarction, especially in the regions with limited technological resources.