Junjian Xiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Junjian Xiang has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Yong Tang
GuangDong Engineering Technology Research Center of Antibody Drug and Immunoassay, Department of Biological Sciences and Biotechnology, College of Life Science and Technology, Jinan University, Guangzhou, China
4 shared publications - Qiangqiang Fu
Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
2 shared publications Chenchen Shao
1 shared publicationFang Zhao
Shenzhen Entry-Exit Inspection and Quarantine Bureau
1 shared publication- Feng Wu
School of Life Sciences, Tsinghua University, Beijing 100084, China
1 shared publication - Guodong Sun
Department of Orthopedics, First Affliated Hospital, Jinan University, Guangzhou, 510632, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 5 December 2018
- Published by Springer Nature in Discover Nano
- Vol. 13 (1) , 397
Plasmonic ELISA for Sensitive Detection of Disease Biomarkers with a Smart Phone-Based Reader
Serum myoglobin is one of the earliest markers for the diagnosis of acute myocardial infarction. It is, therefore, critical to develop a point-of-care testing technology for myoglobin detection. In this work, we reported a sensitive plasmonic immunoassay-based on enzyme-mediated localized surface plasmon resonance change of gold nanorods for the point-of-care testing detection of myoglobin. In addition, we developed a novel plasmonic immunoassay reader using the ambient light sensor of smart phone to increase the accessibility and utility of the plasmonic immunoassay. The linear detection range of gold nanorods-based plasmonic immunoassay for myoglobin detection was 0.1–1000 ng mL−1 and the limit of detection was 0.057 ng mL−1. Myoglobin in serum samples was also analyzed by the plasmonic immunoassay. The results were significantly correlated with those of conventional enzyme-linked immunosorbent assay. The plasmonic immunoassay, coupled with smart phone-based reader, could be widely used for point-of-care testing application of acute myocardial infarction, especially in the regions with limited technological resources.
- 5 December 2018
- Published by Springer Nature in Discover Nano
- Vol. 13 (1) , 397
Open AccessPlasmonic ELISA for Sensitive Detection of Disease Biomarkers with a Smart Phone-Based Reader
Serum myoglobin is one of the earliest markers for the diagnosis of acute myocardial infarction. It is, therefore, critical to develop a point-of-care testing technology for myoglobin detection. In this work, we reported a sensitive plasmonic immunoassay-based on enzyme-mediated localized surface plasmon resonance change of gold nanorods for the point-of-care testing detection of myoglobin. In addition, we developed a novel plasmonic immunoassay reader using the ambient light sensor of smart phone to increase the accessibility and utility of the plasmonic immunoassay. The linear detection range of gold nanorods-based plasmonic immunoassay for myoglobin detection was 0.1–1000 ng mL−1 and the limit of detection was 0.057 ng mL−1. Myoglobin in serum samples was also analyzed by the plasmonic immunoassay. The results were significantly correlated with those of conventional enzyme-linked immunosorbent assay. The plasmonic immunoassay, coupled with smart phone-based reader, could be widely used for point-of-care testing application of acute myocardial infarction, especially in the regions with limited technological resources.
- 1 August 2015
- Vol. 31 (8) , 1115-9
[Preparation and application of monoclonal antibody against human myoglobin].
To prepare the monoclonal antibody (mAb) against human myoglobin (MYO) of high titer and specificity and develop double-antibody sandwich ELISA for detecting MYO in human serum samples. The BALB/c mice were immunized with natural human MYO, and the hybridoma cell lines secreting anti-MYO mAb were established using cell fusion and hybridoma screening techniques. The characteristics of the mAb were identified after affinity purification from ascites. Then the best antibody pair was selected from mAb to establish a one-step sandwich ELISA method. Sixty human serum samples were detected by the homemade ELISA kit and the imported one, respectively. Nine strains of hybridoma cell lines stably secreted anti-MYO mAb. Four strains named 2M1, 3M4, 5M7 and 10M4 could secrete high-quality mAb and the titers of them were in the range of 1.0×10(6) to 2.6×10(6) (A450 value was about 1.0). Three antibody pairs (2M1/HRP-3M4, 5M7/HRP-3M4, 10M4/HRP-5M7) were selected by double-antibody sandwich ELISA. Among them, the 5M7/HRP-3M4 had higher sensitivity and larger linear range. The homemade ELISA kit had a larger linear range (25-1000 ng/mL) than the imported one (25-500 ng/mL) and showed high accuracies in detecting human serum samples, being 95% (19/20) in positive samples and 100% (40/40) in negative samples. With the anti-human MYO mAbs of high specificity and affinity, a one-step sandwich ELISA for detecting human MYO has been established successfully, which provides a basis for the development of domestic ELISA kit.
- 1 August 2015
- Vol. 31 (8) , 1115-9
[Preparation and application of monoclonal antibody against human myoglobin].
To prepare the monoclonal antibody (mAb) against human myoglobin (MYO) of high titer and specificity and develop double-antibody sandwich ELISA for detecting MYO in human serum samples. The BALB/c mice were immunized with natural human MYO, and the hybridoma cell lines secreting anti-MYO mAb were established using cell fusion and hybridoma screening techniques. The characteristics of the mAb were identified after affinity purification from ascites. Then the best antibody pair was selected from mAb to establish a one-step sandwich ELISA method. Sixty human serum samples were detected by the homemade ELISA kit and the imported one, respectively. Nine strains of hybridoma cell lines stably secreted anti-MYO mAb. Four strains named 2M1, 3M4, 5M7 and 10M4 could secrete high-quality mAb and the titers of them were in the range of 1.0×10(6) to 2.6×10(6) (A450 value was about 1.0). Three antibody pairs (2M1/HRP-3M4, 5M7/HRP-3M4, 10M4/HRP-5M7) were selected by double-antibody sandwich ELISA. Among them, the 5M7/HRP-3M4 had higher sensitivity and larger linear range. The homemade ELISA kit had a larger linear range (25-1000 ng/mL) than the imported one (25-500 ng/mL) and showed high accuracies in detecting human serum samples, being 95% (19/20) in positive samples and 100% (40/40) in negative samples. With the anti-human MYO mAbs of high specificity and affinity, a one-step sandwich ELISA for detecting human MYO has been established successfully, which provides a basis for the development of domestic ELISA kit.
- 9 December 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (2) , 529-535
A novel method to detect Listeria monocytogenes via superparamagnetic lateral flow immunoassay
A novel strip test system combining immunomagnetic separation with lateral flow immunoassay (LFIA) was established for the accurate detection of Listeria monocytogenes. In this system, a pair of matched monoclonal antibodies was used to construct a sandwich immunoassay, in which superparamagnetic particles were coupled with one of the antibodies as a labeled antibody to capture the target bacteria, while the other antibody was immobilized on the detection zone. After a 20-min reaction, the strips were analyzed by a novel instrument which could detect the magnetic signal of the immunocomplex in a magnetic field. Sensitivity evaluation showed that the limit of detection (LOD) of the superparamagnetic LFIA system for L. monocytogenes was 104 CFU/mL, which was at least one log lower than conventional LFIA. No cross-reaction was observed when Salmonella, Escherichia coli O157:H7, or three types of harmless Listeria strains were tested. Further evaluation with actual food samples indicated that the superparamagnetic LFIA system showed 100 % concordance with real-time PCR. Therefore, this novel superparamagnetic LFIA system could be used as a rapid, sensitive, and specific method for the detection of L. monocytogenes. Graphical Abstract
- 9 December 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (2) , 529-535
A novel method to detect Listeria monocytogenes via superparamagnetic lateral flow immunoassay
A novel strip test system combining immunomagnetic separation with lateral flow immunoassay (LFIA) was established for the accurate detection of Listeria monocytogenes. In this system, a pair of matched monoclonal antibodies was used to construct a sandwich immunoassay, in which superparamagnetic particles were coupled with one of the antibodies as a labeled antibody to capture the target bacteria, while the other antibody was immobilized on the detection zone. After a 20-min reaction, the strips were analyzed by a novel instrument which could detect the magnetic signal of the immunocomplex in a magnetic field. Sensitivity evaluation showed that the limit of detection (LOD) of the superparamagnetic LFIA system for L. monocytogenes was 104 CFU/mL, which was at least one log lower than conventional LFIA. No cross-reaction was observed when Salmonella, Escherichia coli O157:H7, or three types of harmless Listeria strains were tested. Further evaluation with actual food samples indicated that the superparamagnetic LFIA system showed 100 % concordance with real-time PCR. Therefore, this novel superparamagnetic LFIA system could be used as a rapid, sensitive, and specific method for the detection of L. monocytogenes. Graphical Abstract
- 1 July 2013
- Vol. 29 (7) , 729-33
[Preparation of anti-zearalenone monoclonal antibody and preliminary establishment of colloidal gold immunochromatographic assay for zearalenone].
To prepare the monoclonal antibody against zearalenone (ZEN) toxin and preliminarily establish the colloidal gold immunochromatographic detection method for ZEN. The artificial antigen ZEN-BSA and ZEN-OVA were prepared by active ester method. Mice were immunized with ZEN-OVA and monoclonal antibodies against ZEN were prepared by regular cell fusion and subcloning approach. The titer, subtype and specificity of the antibodies were identified by ELISA. To establish a method of colloidal gold immunochromatographic assay (GICA) for the determination of ZEN, colloidal gold binding cushion was coated with anti-ZEN monoclonal antibody-colloidal gold complex, and the synthetic ZEN-BSA and goat anti-mouse immunoglobulins were sprayed on cellulose nitrate film to form the test (T) band and control (C) band. Identified by SDS-PAGE and UV spectroscopy, the artificial antigen ZEN-BSA and ZEN-OVA were successfully coupled respectively. One hybridoma line (1G4) which could secrete monoclonal antibody specifically against ZEN was obtained by three-time cloning. The ascites titer of this monoclonal antibody reached 1:1.6×10(5);. The antibody subtype was IgG2b. The IC50; to ZEN was 10.2 ng/mL, and the detction limit was 0.58 ng/mL. In addition, the mAb was proved highly specific for ZEN. ZEN metabolites α-zearalanol, β-zearalanol, zearalanone and other similar toxins deoxynivalenol, fumonisin B1, ochratoxin A showed very low or no cross-activity with the monoclonal antibody. The whole assay using the prepared colloidal gold immunochromatographic strip could be finished in 5 min, which could be read by naked eyes. The limit of detection was 100 ng/mL. The anti-ZEN mAb was successfully prepared. And the gold immunochromatographic assay(GICA) for ZEN was preliminarily established with the limit of detection being 100 ng/mL.
- 1 July 2013
- Vol. 29 (7) , 729-33
[Preparation of anti-zearalenone monoclonal antibody and preliminary establishment of colloidal gold immunochromatographic assay for zearalenone].
To prepare the monoclonal antibody against zearalenone (ZEN) toxin and preliminarily establish the colloidal gold immunochromatographic detection method for ZEN. The artificial antigen ZEN-BSA and ZEN-OVA were prepared by active ester method. Mice were immunized with ZEN-OVA and monoclonal antibodies against ZEN were prepared by regular cell fusion and subcloning approach. The titer, subtype and specificity of the antibodies were identified by ELISA. To establish a method of colloidal gold immunochromatographic assay (GICA) for the determination of ZEN, colloidal gold binding cushion was coated with anti-ZEN monoclonal antibody-colloidal gold complex, and the synthetic ZEN-BSA and goat anti-mouse immunoglobulins were sprayed on cellulose nitrate film to form the test (T) band and control (C) band. Identified by SDS-PAGE and UV spectroscopy, the artificial antigen ZEN-BSA and ZEN-OVA were successfully coupled respectively. One hybridoma line (1G4) which could secrete monoclonal antibody specifically against ZEN was obtained by three-time cloning. The ascites titer of this monoclonal antibody reached 1:1.6×10(5);. The antibody subtype was IgG2b. The IC50; to ZEN was 10.2 ng/mL, and the detction limit was 0.58 ng/mL. In addition, the mAb was proved highly specific for ZEN. ZEN metabolites α-zearalanol, β-zearalanol, zearalanone and other similar toxins deoxynivalenol, fumonisin B1, ochratoxin A showed very low or no cross-activity with the monoclonal antibody. The whole assay using the prepared colloidal gold immunochromatographic strip could be finished in 5 min, which could be read by naked eyes. The limit of detection was 100 ng/mL. The anti-ZEN mAb was successfully prepared. And the gold immunochromatographic assay(GICA) for ZEN was preliminarily established with the limit of detection being 100 ng/mL.
- 5 August 2011
- Published by Wiley in Journal of Food Science
- Vol. 76 (6) , T138-T143
Development of a Lateral Flow Immunoassay (LFA) Strip for the Rapid Detection of 1‐Aminohydantoin in Meat Samples
Abstract: Due to the potential toxic effects of the nitrofuran family of antibiotics, their use in animals in the food industry has raised health concerns. This study was aimed to develop a lateral flow assay (LFA) based on competitive format for the detection of 1‐aminohydantoin (AHD) in meat samples. The assay could be completed in 1 min and detected AHDs derivates (CPAHD) at 3 ng/mL, equivalent to 1.40 ng/mL of AHD, which was much lower than that reported in the literature by similar method. The antibody showed no cross‐reactivity with a panel of more than 10 nitrofuran analogs except for nitrofurantoin at a high concentration. The test strip was stable at room temperature for up to 8 wk or at 37 °C for 4 wk. Parallel analyses of meat samples with LFA and enzyme‐linked immunosorbent assay (ELISA) obtained data in good agreement. This developed gold nanoparticle based LFA had a good specificity, sensitivity, stability, and reliability. It was potentially suitable for on‐the‐spot large‐scale screening of meat samples, and even more other applications. Practical Application: Nitrofurantoin is one of antibiotics of the nitrofuran family, which has been used not only to prevent and treat diseases, but also to promote growth in animals. However, concerning the carcinogenicity of the metabolite of nitrofurantoin (AHD), a new fast and convenient method for monitoring AHD should be established. We describe the development of a new test assay for rapid screening of meat samples.
- 5 August 2011
- Published by Wiley in Journal of Food Science
- Vol. 76 (6) , T138-T143
Development of a Lateral Flow Immunoassay (LFA) Strip for the Rapid Detection of 1‐Aminohydantoin in Meat Samples
Abstract: Due to the potential toxic effects of the nitrofuran family of antibiotics, their use in animals in the food industry has raised health concerns. This study was aimed to develop a lateral flow assay (LFA) based on competitive format for the detection of 1‐aminohydantoin (AHD) in meat samples. The assay could be completed in 1 min and detected AHDs derivates (CPAHD) at 3 ng/mL, equivalent to 1.40 ng/mL of AHD, which was much lower than that reported in the literature by similar method. The antibody showed no cross‐reactivity with a panel of more than 10 nitrofuran analogs except for nitrofurantoin at a high concentration. The test strip was stable at room temperature for up to 8 wk or at 37 °C for 4 wk. Parallel analyses of meat samples with LFA and enzyme‐linked immunosorbent assay (ELISA) obtained data in good agreement. This developed gold nanoparticle based LFA had a good specificity, sensitivity, stability, and reliability. It was potentially suitable for on‐the‐spot large‐scale screening of meat samples, and even more other applications. Practical Application: Nitrofurantoin is one of antibiotics of the nitrofuran family, which has been used not only to prevent and treat diseases, but also to promote growth in animals. However, concerning the carcinogenicity of the metabolite of nitrofurantoin (AHD), a new fast and convenient method for monitoring AHD should be established. We describe the development of a new test assay for rapid screening of meat samples.
- 5 April 2011
- Published by Springer Nature in European Food Research and Technology
- Vol. 232 (6) , 963-969
An immunoassay based on bio-barcode method for quantitative detection of semicarbazide
- 5 April 2011
- Published by Springer Nature in European Food Research and Technology
- Vol. 232 (6) , 963-969
An immunoassay based on bio-barcode method for quantitative detection of semicarbazide
- 1 September 2010
- Published by Springer Nature in European Food Research and Technology
- Vol. 232 (1) , 9-16
A sensitive immunochromatographic assay using colloidal gold–antibody probe for the rapid detection of semicarbazide in meat specimens
- 1 September 2010
- Published by Springer Nature in European Food Research and Technology
- Vol. 232 (1) , 9-16
A sensitive immunochromatographic assay using colloidal gold–antibody probe for the rapid detection of semicarbazide in meat specimens