YNYasunori Niwa

Yasunori Niwa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yasunori Niwa has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Oxygen reserve index (ORi™) contributes to prediction of hypoxemia and patient safety during tracheal stent insertion using rigid bronchoscopy: a case report

    by Yasunori Niwa, Juntaro Shiba, Hiromasa Fujita, Risa Oka, Mamoru Takeuchi

    The oxygen reserve index (ORi™) is a new noninvasive and continuous variable, which represents a moderate hyperoxygenation status, with a unitless scale between 0.00 and 1.00. When percutaneous oxygen saturation (SpO2) exceeds 100%, arterial blood oxygen partial pressure cannot be evaluated without performing arterial blood gas analysis. Because of significant air leakage during rigid bronchoscopy, it is difficult to monitor respiration using capnography, which does not measure end-tidal carbon dioxide (ETCO2) accurately. A 66-year-old man (175 cm, 76.8 kg) with a chief complaint of difficulty in breathing was diagnosed with a thyroid tumor. Computed tomography revealed tracheal stenosis due to direct invasion of the thyroid tumor; therefore, tracheal stenting was planned immediately. After supplying 6 L/min oxygen with a face mask and administering 180 mg of propofol intravenously, the supraglottic airway was intubated. General anesthesia (total intravenous anesthesia) through continuous administration of 6–10 mg/kg/h of propofol and intermittent administration of 50 µg of fentanyl (total 200 µg) preserved spontaneous breathing. During tracheal stent insertion, disconnection between the oxygen supply system and rigid bronchoscopy, and tracheal stent expansion, the ORi tended to decrease before SpO2 decreased. Thus, measuring ORi could prevent hypoxemia during tracheal stent insertion using rigid bronchoscopy.


  • Current Knowledge of Epiduroscopy

    by Takashi Igarashi, Nobuhiro Shimada, Yasunori Niwa, Masaaki Satoh, Kunihiko Murai, Mamoru Takeuchi

    エピドラスコピーは難治性の腰下肢痛患者に対する診断治療法の一つである.診断面の特長は,通常の画像で得られにくい炎症や癒着などの所見を直接観察できる点にある.治療面の特長は,内視鏡下での生理食塩水を用いた硬膜外腔の灌流,神経周囲の癒着や瘢痕組織の剥離,目的部位への薬液投与の3つである.エピドラスコピーは,腰椎椎間板ヘルニア,腰部脊柱管狭窄症,腰椎手術後疼痛症候群への有効性が確認されているが,近年では新たな適応例や治療効果を高める工夫などが報告されて,さらなる発展が期待できる.

  • Open Access

    A Case of Cardiac Tamponade during Thoracoscopic Surgery : Usefulness of Transesophageal Echocardiography

    by Miyuki Takahashi, Yasunori Niwa, Miho Urayama, Nobuhiro Shimada, Mamoru Takeuchi

    胸腔鏡手術中に発症した心タンポナーデに対して,経食道心エコー図検査(TEE)を用いて診断し救命し得た.症例は65歳の男性.左転移性肺腫瘍に対し,右側臥位で胸腔鏡下左肺上大区域切除術が行われた.術中,検体摘出直後に突然収縮期血圧が50mmHgに低下した.胸壁からの出血を認め急速輸液と昇圧剤投与を行ったが,止血完了後も循環動態は安定しなかった.原因検索のためTEEを行い心タンポナーデと診断し,心膜切開後速やかに循環動態は安定した.術中心タンポナーデはまれであるが起こりうる合併症として鑑別が必要である.またTEEは術中の急激な循環不全の際に有用なモニターである.


  • Spinal Epidural Hematoma Following Epidural Anesthesia

    by Takashi Igarashi, Koki Taira, Nobuhiro Shimada, Kunihiko Murai, Yasunori Niwa, Mamoru Takeuchi

    硬膜外麻酔後に発生した脊髄硬膜外血腫について報告する.症例は,81歳女性で,硬膜外麻酔を併用した全身麻酔下に行ったイレウス手術の術後第3病日に脊髄硬膜外血腫を発症した.緊急椎弓切除術を施行し,下肢の麻痺は改善した.硬膜外麻酔や硬膜外腔内視鏡の後に腰背部や下肢の痛みが出現した場合は,硬膜外血腫を念頭に置き厳密に神経所見を観察し,麻痺が出現したときは早期の検査と治療が必要である.


    • 1 September 2014
      • Vol. 63  (9) , 1025-8

    [McGRATH MAC Videolaryngoscope: clinical assessment of its performance in 50 surgical patients].

    by Yumiko Negishi, Nobuhiro Shimada, Miho Urayama, Yasunori Niwa, Mamoru Takeuchi

    The aim of this study was to evaluate the utility of McGRATH MAC Videolaryngoscope in tracheal intubation of surgical patients. McGRATH MAC Videolaryngoscope was used for the tracheal intubation in 50 surgical patients undergoing general anesthesia. We compared the percentage of glottic opening score between McGRATH MAC Videolaryngoscope and Coopdech Videolaryngoscope Portable VLP-100 by anesthesia staffs and unexperienced anesthetic trainees. The number of intubation attempts and the time to complete intubation were also recorded. In 49 of 50 surgical patients including 18 patients with potential difficult airways, successful intubation was performed with McGRATH MAC. Not only anesthesia staffs but also unexperienced anesthetic trainees could obtain better view of the glottis with McGRATH compared with Coopdech Videolaryngoscope Portable VLP-100. McGRATH MAC Videolaryngoscope facilitates tracheal intubation in surgical patients.

    • 1 August 2014
      • Vol. 63  (8) , 927-30

    [Comparative study of the KingVision videolaryngoscope and Airwayscope using manikins].

    by Kentaro Hayashi, Nobuhiro Shimada, Juntaro Shiba, Yasunori Niwa, Mamoru Takeuchi

    KingVision (KV) is a new videolaryngoscope. In this study, we compared the ease of use of the KV with the Airwayscope (AWS) by experienced personnel in a simulated manikin. Twenty-eight anesthesiologists participated in this study. We used an advanced patient simulator (AIRSIM) to simulate normal manikin and difficult airway scenarios including cervical spine rigidity and limited mouth opening. We compared the time required for visualization of the glottis (Tv) and tracheal intubation (Ti), and analyzed the percentage of glottic opening (POGO) score and the success rates for tracheal intubation. In normal manikin, the Tv and Ti with the KV were significantly shorter than with the AWS (P < 0.05). The POGO score with the KV was higher than with the AWS (P < 0.05). In difficult airway scenarios including both cervical spine rigidity and limited mouth opening, the Tv and Ti with the KV were shorter than with only the AWS (P < 0.05). There is not much difference between KV and AWS regarding the POGO score in difficult airway. KV may be a suitable device for routine anesthesia care and difficult airway intubation. Further studies in a clinical setting are necessary to confirm these findings.


    • 1 July 2013
      • Vol. 62  (7) , 855-8

    [Use of RRa sensor in a pediatric patient with post-adenotonsillectomy].

    by Yasunori Niwa, Soichiro Inoue, Fumito Nakamura, Naoyuki Taga, Mamoru Takeuchi, Hiroaki Konishi

    Rad-87 and RRa are new acoustic monitoring devices which can monitor the respiratory rate. To our knowledge, no studies have reported the RRa sensor used in pediatric patients after surgery. We succeeded in measuring the respiratory rate with the RRa sensor in the Pediatric Intensive Care Unit(PICU). A 10-year-old boy, 14.5 kg in weight and 119.6 cm in height, with cerebral palsy, mental retardation, epilepsy, and obstructive sleep apnea due to adenoidal and tonsillar hypertrophy, was scheduled for adenotonsillectomy under general anesthesia. Anesthesia was maintained with oxygen, air, sevoflurane (1.5-2.0%), remifentanil (0.1 to 0.5 microg . kg-1. min-1), and fentanyl (4 microg . kg-1). The operating time was 55 minutes, and the duration of anesthesia was 133 minutes. After finishing the surgery, we attached the RRa sensor to his anterior neck and monitored his respiratory rate. Furthermore, RRa could count his respiratory rate, during transfer from the operating room to PICU. The patient was sedated with dexmedetomidine (0.28 microg . kg-1 . min-1) at PICU, and his respiratory rate was accurately measured with the RRa sensor. We hope that Rad-87 and RRa sensors will become useful for measuring the respiratory rate in pediatric patients in the future.

    • 1 July 2013
      • Vol. 62  (7) , 867-9

    [Tracheal intubation using Airtraq optical laryngoscope in an adult patient with Goldenhar syndrome].

    by Hiromi Sasanuma, Yasunori Niwa, Nobuhiro Shimada, Masanari Machida, Takeshi Irei, Kenji Hayashi, Mamoru Takeuchi

    A 23-year-old woman with Goldenhar syndrome and conductive deafness was scheduled for tympanoplasty. Goldenhar syndrome is a developmental disorder characterized by ear malformation, mandibular hypoplasia, and vertebral anomalies. Furthermore, she had micrognathia, trismus, and mandibular hypoplasia. Awake taracheal intubation was attempted to prevent airway obstruction, because we had anticipated her difficult airway (micrognathia, trismus, and mandibular hypoplasia). The vocal cords were visualized with a Cormac and Lehane grade I, using the Airtraq optical laryngoscope Small (Size 2), under sedation. Then, an endotracheal tube was inserted after induction of general anesthesia. This is the first case report on the successful orotracheal intubation using Airtraq in an adult with Goldenhar syndrome.


    • 1 June 2013
      • Vol. 62  (6) , 757-60

    [The KINGVISION: clinical assessment of performance in 50 patients].

    by Nobuhiro Shimada, Kentaro Hayashi, Kenzaburo Sugimoto, Miyuki Takahashi, Yasunori Niwa, Mamoru Takeuchi

    The aim of this study was to evaluate the suitability of the KINGVISION videolaryngoscope for tracheal intubation. Endotracheal intubation was performed using the KINGVISION in 50 patients undergoing general anesthesia. We compared the percentage of glottic opening score between Coopdech Videolaryngoscope Portable VLP100 and the KINGVISION with staff anesthesiologist and novice personnel. The time to complete instrumentation and optimizing procedures were also recorded. The KINGVISION allowed visualization of the glottis and successful intubation in all patients, including 11 patients with difficult airway. There were no differences in the time to intubation between staff anesthesiologist and novice personnel. Furthermore, percentage of glottic opening score was higher with KINGVISION than with Coopdech Videolaryngoscope Portable VLP100 among staff anesthesiologist and novice personnel. The KINGVISION could be an effective aid to airway management in surgical patients.