Angela Wai Shan Fung

Angela Wai Shan Fung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Angela Wai Shan Fung has a total of 108 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Guidance for continuous glucose monitor (CGM) use in Canadian hospitals

    by Julie L.V. Shaw, Davor Brinc, Angela W.S. Fung, Robyn L. Houlden, Annie Garon-Mailer, Lisa Maks, Sarah Moore-Vasram, Leta C. Philp, Atoosa Rezvanpour, Cathy J. Sun, et al.

  • Open Access

    Assessing Analytical Performance and Correct Classification for Cardiac Troponin Deltas Across Diagnostic Pathways Used for Myocardial Infarction

    by Peter A. Kavsak, Sameer Sharif, Wael L. Demian, Won-Shik Choi, Emilie P. Belley-Cote, Jennifer Taher, Jennifer L. Shea, David W. Blank, Michael Knauer, Laurel Thorlacius, et al.

    Background: In the emergency setting, many diagnostic pathways incorporate change in high-sensitivity cardiac troponin (hs-cTn) concentrations (i.e., the delta) to classify patients as low-risk (rule-out) or high-risk (rule-in) for possible myocardial infarction (MI). However, the impact of analytical variation on the delta for correct classification is unknown, especially at concentrations below and around the 99th percentile. Our objective was to assess the impact of delta variation for correct risk classification across the European Society of Cardiology (ESC 0/1 h and 0/2 h), the High-STEACS, and the common change criteria (3C) pathways. Methods: A yearlong accuracy study for hs-cTnT was performed where laboratories across Canada tested three patient-based samples (level 1 target value = 6 ng/L, level 2 target value = 9 ng/L, level 3 target value = 12 ng/L) monthly across 41 different analyzers. The assigned low-delta between levels 1 and 2 was 3 ng/L (i.e., 9 − 6 = 3 ng/L) and the assigned high-delta between levels 1 and 3 was 6 ng/L (i.e., 12 − 6 = 6 ng/L). The low- and high-deltas for each analyzer were determined monthly from the measured values, with the difference calculated from the assigned deltas. The obtained deltas were then assessed via the different pathways on correct classification (i.e., percent correct with 95% confidence intervals, CI) and using non-parametric analyses. Results: The median (interquartile range) difference between the measured versus assigned low-delta (n = 436) and high-delta (n = 439) was −1 ng/L (−1 to 0). The correct classification differed among the pathways. The ESC 0/1 h pathway yielded the lowest percentage of correct classification at 35.3% (95% CI: 30.8 to 40.0) for the low-delta and 90.0% (95% CI: 86.8 to 92.6) for the high-delta. The 3C and ESC 0/2 h pathways yielded higher and equivalent estimates on correct classification: 95.2% (95% CI: 92.7 to 97.0) for the low-delta and 98.2% (95% CI: 96.4 to 99.2) for the high-delta. The High-STEACS pathway yielded 99.5% (95% CI: 98.4 to 99.9) of correct classifications for the high-delta but only 36.2% (95% CI: 31.7 to 40.9) for the low-delta. Conclusions: Analytical variation will impact risk classification for MI when using hs-cTn deltas alone per the pathways. The 3C and ESC 0/2 h pathways have <5% misclassification when using deltas for hs-cTnT in this dataset. Additional studies with different hs-cTnI assays at concentrations below and near the 99th percentile are warranted to confirm these findings.


  • Vitamin D Toxicity from an Unusual and Unexpected Source: A Report of 2 Cases

    by Carolina Silva, Angela W.S. Fung, Vanessa Masson, Katrina Assen, Valerie Ward, Jordan McKenzie, Tom D. Blydt-Hansen, Jake Cosme, Grace van der Gugten, Vilte E. Barakauskas, et al.

    Introduction: Hypervitaminosis D is a relatively uncommon etiology of hypercalcemia. Toxicity is usually caused by very high doses, mostly secondary to erroneous prescription or administration of vitamin D, and less commonly, contaminated foods or manufacturing errors of vitamin D-containing supplements. Case Presentation: A 16-year-old male, previously healthy, presented with 2-week history of nonspecific symptoms (fatigue, gastrointestinal complaints). Investigations showed acute kidney injury and hypercalcemia (total calcium 3.81 mmol/L). Further diagnostic workup revealed markedly elevated 25-hydroxyvitamin D levels (1,910 nmol/L). He denied taking any vitamin D supplements; however, he reported consumption of creatine and protein supplements. Mass spectrometry analysis of the creatine supplement estimated a vitamin D content of 425,000 IU per serving (100 times the upper tolerable daily dose). A few months later, another previously healthy adolescent presented with severe hypercalcemia and acute kidney injury secondary to hypervitaminosis D. He was also using a creatine supplement, from the same manufacturer brand and lot. Both patients were treated with intravenous hydration, calcitonin, and pamidronate. They maintained normocalcemia after their initial presentation but required low-calcium diets and laboratory testing for months after this exposure. Discussion/Conclusion: We present 2 cases of hypervitaminosis D caused by a manufacturing error of a natural health product which did not claim to contain vitamin D. The use of dietary supplements is highly prevalent; this should be incorporated while taking medical history, and considered a potential source of toxicity when an alternative source cannot be found, regardless of the product label.


  • Intrapartum Fetal Scalp Lactate Testing: Considerations for Implementation and Clinical Decision Making

    by Angela W.S. Fung, Andre Mattman, Li Wang, Teralee Burton, Lori A. Beach, A.K. Füzéry

  • Rapid COVID-19 testing: Speed, quality and cost. Can you have all three?

    by Lori A. Beach, Angela W.S. Fung, Michael J. Knauer, Julie L.V. Shaw, Jennifer Taher


  • Open Access

    Quality assurance practices for point of care testing programs: Recommendations by the Canadian society of clinical chemists point of care testing interest group

    by Allison A. Venner, Lori A. Beach, Jennifer L. Shea, Michael J. Knauer, Yun Huang, Angela W.S. Fung, James Dalton, Mathieu Provencal, Julie L.V. Shaw


  • Clinical utility of serum IgG4 measurement

    by Julia L. Varghese, Angela W.S. Fung, Andre Mattman, Tien T.T. Quach, Deonne Thaddeus V. Gauiran, Mollie N. Carruthers, Luke Y.C. Chen


  • Open Access

    Performance of StatSensor Point-of-Care Device for Measuring Creatinine in Patients With Chronic Kidney Disease and Postkidney Transplantation

    by Melissa Nataatmadja, Angela W. S. Fung, Beryl Jacobson, Jack Ferera, Eva Bernstein, Paul Komenda, Andre Mattman, David Seccombe, Adeera Levin

    Background: The StatSensor is a point-of-care device which measures creatinine in capillary whole blood. Previous studies reported an underestimation of the creatinine measurements at high creatinine concentrations and were performed in the prestandardization era for creatinine. Objective: This accuracy-based study evaluates the use of this device in kidney-transplanted patients and those with chronic kidney disease (CKD). Design: Cross-sectional diagnostic accuracy study. Setting: Nephrology outpatient clinic in an urban tertiary center. Participants: Adults with CKD or a functioning kidney transplant. Measurements: Duplicate StatSensor creatinine measurements were performed on capillary whole blood samples collected by direct fingerstick and SAFE-T-FILL collection device. Results were compared with simultaneous venous blood sampling for serum and plasma creatinine measured by an enzymatic method on the Roche Integra 400 mainframe analyzer with traceability to the ID-GC-MS (isotope dilution gas chromatography mass spectrometry) reference method. Methods: Deming regression, Pearson correlation coefficient, and Bland-Altman analysis were used to assess accuracy and comparability between capillary whole blood measured by StatSensor and plasma creatinine measured by routine analyzer with traceability to the reference method. Estimated glomerular filtration (eGFR) rates were calculated using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation and concordance with Kidney Disease Improving Global Outcomes (KDIGO) CKD stage classification was evaluated. Results: There were 60 participants (mean age = 61.9 ± 15.0 years, 55% men, 33% transplant, mean plasma creatinine = 137 ± 59 µmol/L). Bland-Altman analysis indicated a positive mean bias of 12.7 µmol/L between StatSensor fingerstick creatinine measurement and plasma creatinine. Comparison of eGFR (CKD-EPI) calculated from the StatSensor fingerstick creatinine versus plasma creatinine showed misclassification across all KDIGO CKD stages. Postanalytical correction of the bias did not improve misclassifications. The use of mean of duplicate StatSensor creatinine results did not improve performance compared with the use of singlet results. Limitations: Single center, limited participant numbers. Conclusions: The results of our study suggest that the limiting characteristics of the StatSensor device are not only bias, but also imprecision. The level of imprecision observed may influence clinical decision-making and limit the usefulness of StatSensor as a CKD screening tool. If choosing to utilize it for either screening for or monitoring CKD, it is essential that clinicians understand the limitations of point-of-care devices and apply this knowledge to test interpretation.