Suzanne Spijkers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Suzanne Spijkers has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Annemieke S. Littooij
7 shared publicationsRutger A. J. Nievelstein
Department of Radiology and Nuclear Medicine, University Medical Centre Utrecht/Wilhelmina Children’s Hospital, Utrecht University, Utrecht, The Netherlands
5 shared publicationsAuke Beishuizen
3 shared publicationsBart de Keizer
Department of Radiology and Nuclear Medicine, University Medical Centre Utrecht/Wilhelmina Children’s Hospital, Utrecht University, Utrecht, The Netherlands
2 shared publicationsCharlotte de Lange
Department of Diagnostic Imaging and Intervention, Oslo University Hospital, Rikshospitalet, Oslo, Norway
2 shared publicationsClaudio Granata
Department of Radiology, Institute for Maternal and Child Health IRCCS Burlo Garofolo, Trieste, Italy
2 shared publications
Latest Publications
- Open Access
- 22 May 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (12) , 8925-8936
Whole-body MRI versus an [18F]FDG-PET/CT-based reference standard for early response assessment and restaging of paediatric Hodgkin’s lymphoma: a prospective multicentre study
Objectives: To compare WB-MRI with an [18F]FDG-PET/CT-based reference for early response assessment and restaging in children with Hodgkin’s lymphoma (HL). Methods: Fifty-one children (ages 10–17) with HL were included in this prospective, multicentre study. All participants underwent WB-MRI and [18F]FDG-PET/CT at early response assessment. Thirteen of the 51 patients also underwent both WB-MRI and [18F]FDG-PET/CT at restaging. Two radiologists independently evaluated all WB-MR images in two separate readings: without and with DWI. The [18F]FDG-PET/CT examinations were evaluated by a nuclear medicine physician. An expert panel assessed all discrepancies between WB-MRI and [18F]FDG-PET/CT to derive the [18F]FDG-PET/CT-based reference standard. Inter-observer agreement for WB-MRI was calculated using kappa statistics. Concordance, PPV, NPV, sensitivity and specificity for a correct assessment of the response between WB-MRI and the reference standard were calculated for both nodal and extra-nodal disease presence and total response evaluation. Results: Inter-observer agreement of WB-MRI including DWI between both readers was moderate (κ 0.46–0.60). For early response assessment, WB-MRI DWI agreed with the reference standard in 33/51 patients (65%, 95% CI 51–77%) versus 15/51 (29%, 95% CI 19–43%) for WB-MRI without DWI. For restaging, WB-MRI including DWI agreed with the reference standard in 9/13 patients (69%, 95% CI 42–87%) versus 5/13 patients (38%, 95% CI 18–64%) for WB-MRI without DWI. Conclusions: The addition of DWI to the WB-MRI protocol in early response assessment and restaging of paediatric HL improved agreement with the [18F]FDG-PET/CT-based reference standard. However, WB-MRI remained discordant in 30% of the patients compared to standard imaging for assessing residual disease presence. Key Points: • Inter-observer agreement of WB-MRI including DWI between both readers was moderate for (early) response assessment of paediatric Hodgkin’s lymphoma. • The addition of DWI to the WB-MRI protocol in early response assessment and restaging of paediatric Hodgkin’s lymphoma improved agreement with the [18F]FDG-PET/CT-based reference standard. • WB-MRI including DWI agreed with the reference standard in respectively 65% and 69% of the patients for early response assessment and restaging.
- 22 May 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (12) , 8925-8936
Open AccessWhole-body MRI versus an [18F]FDG-PET/CT-based reference standard for early response assessment and restaging of paediatric Hodgkin’s lymphoma: a prospective multicentre study
Objectives: To compare WB-MRI with an [18F]FDG-PET/CT-based reference for early response assessment and restaging in children with Hodgkin’s lymphoma (HL). Methods: Fifty-one children (ages 10–17) with HL were included in this prospective, multicentre study. All participants underwent WB-MRI and [18F]FDG-PET/CT at early response assessment. Thirteen of the 51 patients also underwent both WB-MRI and [18F]FDG-PET/CT at restaging. Two radiologists independently evaluated all WB-MR images in two separate readings: without and with DWI. The [18F]FDG-PET/CT examinations were evaluated by a nuclear medicine physician. An expert panel assessed all discrepancies between WB-MRI and [18F]FDG-PET/CT to derive the [18F]FDG-PET/CT-based reference standard. Inter-observer agreement for WB-MRI was calculated using kappa statistics. Concordance, PPV, NPV, sensitivity and specificity for a correct assessment of the response between WB-MRI and the reference standard were calculated for both nodal and extra-nodal disease presence and total response evaluation. Results: Inter-observer agreement of WB-MRI including DWI between both readers was moderate (κ 0.46–0.60). For early response assessment, WB-MRI DWI agreed with the reference standard in 33/51 patients (65%, 95% CI 51–77%) versus 15/51 (29%, 95% CI 19–43%) for WB-MRI without DWI. For restaging, WB-MRI including DWI agreed with the reference standard in 9/13 patients (69%, 95% CI 42–87%) versus 5/13 patients (38%, 95% CI 18–64%) for WB-MRI without DWI. Conclusions: The addition of DWI to the WB-MRI protocol in early response assessment and restaging of paediatric HL improved agreement with the [18F]FDG-PET/CT-based reference standard. However, WB-MRI remained discordant in 30% of the patients compared to standard imaging for assessing residual disease presence. Key Points: • Inter-observer agreement of WB-MRI including DWI between both readers was moderate for (early) response assessment of paediatric Hodgkin’s lymphoma. • The addition of DWI to the WB-MRI protocol in early response assessment and restaging of paediatric Hodgkin’s lymphoma improved agreement with the [18F]FDG-PET/CT-based reference standard. • WB-MRI including DWI agreed with the reference standard in respectively 65% and 69% of the patients for early response assessment and restaging.
- Open Access
- 3 September 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (3) , 1494-1504
Whole-body MRI versus an FDG-PET/CT-based reference standard for staging of paediatric Hodgkin lymphoma: a prospective multicentre study
Objectives: To assess the concordance of whole-body MRI (WB-MRI) and an FDG-PET/CT-based reference standard for the initial staging in children with Hodgkin lymphoma (HL) Methods: Children with newly diagnosed HL were included in this prospective, multicentre, international study and underwent WB-MRI and FDG-PET/CT at staging. Two radiologists and a nuclear medicine physician independently evaluated all images. Discrepancies between WB-MRI and FDG-PET/CT were assessed by an expert panel. All FDG-PET/CT errors were corrected to derive the FDG-PET/CT-based reference standard. The expert panel corrected all reader errors in the WB-MRI DWI dataset to form the intrinsic MRI data. Inter-observer agreement for WB-MRI DWI was calculated using overall agreement, specific agreements and kappa statistics. Concordance for correct classification of all disease sites and disease stage between WB-MRI (without DWI, with DWI and intrinsic WB-MRI DWI) and the reference standard was calculated as primary outcome. Secondary outcomes included positive predictive value, negative predictive value and kappa statistics. Clustering within patients was accounted for using a mixed-effect logistic regression model with random intercepts and a multilevel kappa analysis. Results: Sixty-eight children were included. Inter-observer agreement between WB-MRI DWI readers was good for disease stage (κ = 0.74). WB-MRI DWI agreed with the FDG-PET/CT-based reference standard for determining disease stage in 96% of the patients versus 88% for WB-MRI without DWI. Agreement between WB-MRI DWI and the reference standard was excellent for both nodal (98%) and extra-nodal (100%) staging. Conclusions: WB-MRI DWI showed excellent agreement with the FDG-PET/CT-based reference standard. The addition of DWI to the WB-MRI protocol improved the staging agreement. Key Points: • This study showed excellent agreement between WB-MRI DWI and an FDG-PET/CT-based reference standard for staging paediatric HL. • Diffusion-weighted imaging is a useful addition to WB-MRI in staging paediatric HL. • Inter-observer agreement for WB-MRI DWI was good for both nodal and extra-nodal staging and determining disease stage.
- 3 September 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (3) , 1494-1504
Open AccessWhole-body MRI versus an FDG-PET/CT-based reference standard for staging of paediatric Hodgkin lymphoma: a prospective multicentre study
Objectives: To assess the concordance of whole-body MRI (WB-MRI) and an FDG-PET/CT-based reference standard for the initial staging in children with Hodgkin lymphoma (HL) Methods: Children with newly diagnosed HL were included in this prospective, multicentre, international study and underwent WB-MRI and FDG-PET/CT at staging. Two radiologists and a nuclear medicine physician independently evaluated all images. Discrepancies between WB-MRI and FDG-PET/CT were assessed by an expert panel. All FDG-PET/CT errors were corrected to derive the FDG-PET/CT-based reference standard. The expert panel corrected all reader errors in the WB-MRI DWI dataset to form the intrinsic MRI data. Inter-observer agreement for WB-MRI DWI was calculated using overall agreement, specific agreements and kappa statistics. Concordance for correct classification of all disease sites and disease stage between WB-MRI (without DWI, with DWI and intrinsic WB-MRI DWI) and the reference standard was calculated as primary outcome. Secondary outcomes included positive predictive value, negative predictive value and kappa statistics. Clustering within patients was accounted for using a mixed-effect logistic regression model with random intercepts and a multilevel kappa analysis. Results: Sixty-eight children were included. Inter-observer agreement between WB-MRI DWI readers was good for disease stage (κ = 0.74). WB-MRI DWI agreed with the FDG-PET/CT-based reference standard for determining disease stage in 96% of the patients versus 88% for WB-MRI without DWI. Agreement between WB-MRI DWI and the reference standard was excellent for both nodal (98%) and extra-nodal (100%) staging. Conclusions: WB-MRI DWI showed excellent agreement with the FDG-PET/CT-based reference standard. The addition of DWI to the WB-MRI protocol improved the staging agreement. Key Points: • This study showed excellent agreement between WB-MRI DWI and an FDG-PET/CT-based reference standard for staging paediatric HL. • Diffusion-weighted imaging is a useful addition to WB-MRI in staging paediatric HL. • Inter-observer agreement for WB-MRI DWI was good for both nodal and extra-nodal staging and determining disease stage.
- Open Access
- 7 June 2020
- Published by Springer Nature in Pediatric Radiology
- Vol. 50 (9) , 1263-1270
Abdominal lymph node size in children at computed tomography
Background: Lymph node enlargement is commonly used to indicate abnormality. Objective: To evaluate the normal size and prevalence of abdominal lymph nodes in children at CT. Materials and methods: In this retrospective study, we included a total of 152 children ages 1–17 years who underwent abdominal CT examination after high-energy trauma. We measured abdominal lymph nodes in five lymph node stations (inguinal, iliac, para-aortic, hepatic and mesenteric). For the largest lymph node in each level, we measured long- and short-axis diameters in both the axial and coronal planes. We then calculated distribution parameters, correlation coefficients between lymph node size and age, and reference intervals. Results: The prevalence of detectable lymph nodes was high for the inguinal (100%), iliac (98%), para-aortic (97%) and mesenteric (99%) stations and lower for the hepatic station (32%). Lymph node size showed small to medium significant correlations (ranging from 0.21 to 0.50) with age. When applying the Lugano criteria and RECIST (Response Criteria in Solid Tumors), 29 children (19%) would have had one or more enlarged abdominal lymph nodes. Conclusion: The results of this study provide normative data of abdominal lymph node size in children. The current adult guidelines for enlarged lymph nodes seem adequate for most children with the exception of young adolescents, in which larger lymph nodes were relatively common, particularly in the inguinal region.
- 7 June 2020
- Published by Springer Nature in Pediatric Radiology
- Vol. 50 (9) , 1263-1270
Open AccessAbdominal lymph node size in children at computed tomography
Background: Lymph node enlargement is commonly used to indicate abnormality. Objective: To evaluate the normal size and prevalence of abdominal lymph nodes in children at CT. Materials and methods: In this retrospective study, we included a total of 152 children ages 1–17 years who underwent abdominal CT examination after high-energy trauma. We measured abdominal lymph nodes in five lymph node stations (inguinal, iliac, para-aortic, hepatic and mesenteric). For the largest lymph node in each level, we measured long- and short-axis diameters in both the axial and coronal planes. We then calculated distribution parameters, correlation coefficients between lymph node size and age, and reference intervals. Results: The prevalence of detectable lymph nodes was high for the inguinal (100%), iliac (98%), para-aortic (97%) and mesenteric (99%) stations and lower for the hepatic station (32%). Lymph node size showed small to medium significant correlations (ranging from 0.21 to 0.50) with age. When applying the Lugano criteria and RECIST (Response Criteria in Solid Tumors), 29 children (19%) would have had one or more enlarged abdominal lymph nodes. Conclusion: The results of this study provide normative data of abdominal lymph node size in children. The current adult guidelines for enlarged lymph nodes seem adequate for most children with the exception of young adolescents, in which larger lymph nodes were relatively common, particularly in the inguinal region.
- Open Access
- 18 December 2019
- Published by Springer Nature in Pediatric Radiology
- Vol. 50 (4) , 534-542
Measurements of cervical lymph nodes in children on computed tomography
Background: No normal measurements or specific size criteria have been described for cervical lymph nodes in children. Objective: To determine the normal measurements of cervical lymph nodes in children on CT. Materials and methods: We included 142 children (ages 1–17 years) who underwent cervical CT examination after high-energy trauma. We evaluated axial and coronal 2-mm reconstructions for lymph nodes at six cervical levels. For the largest lymph node at each level, we measured diameters in both the long and short axial axes and the long coronal axis. Results: A total of 733 lymph nodes were measured in 142 children (62% boys, 38% girls). The greatest measured diameters were 14 mm for the short axis in the axial plane, 24 mm for the long axis in the axial plane and 28 mm for the long axis in the coronal plane. The Pearson correlation coefficient for age and lymph node size at Levels IV–VI was in the range of 0.19–0.47. Conclusion: Lymph nodes with an axial short-axis diameter exceeding 15 mm for Level II and 10 mm for all other cervical levels are uncommon in otherwise healthy children.
- 18 December 2019
- Published by Springer Nature in Pediatric Radiology
- Vol. 50 (4) , 534-542
Open AccessMeasurements of cervical lymph nodes in children on computed tomography
Background: No normal measurements or specific size criteria have been described for cervical lymph nodes in children. Objective: To determine the normal measurements of cervical lymph nodes in children on CT. Materials and methods: We included 142 children (ages 1–17 years) who underwent cervical CT examination after high-energy trauma. We evaluated axial and coronal 2-mm reconstructions for lymph nodes at six cervical levels. For the largest lymph node at each level, we measured diameters in both the long and short axial axes and the long coronal axis. Results: A total of 733 lymph nodes were measured in 142 children (62% boys, 38% girls). The greatest measured diameters were 14 mm for the short axis in the axial plane, 24 mm for the long axis in the axial plane and 28 mm for the long axis in the coronal plane. The Pearson correlation coefficient for age and lymph node size at Levels IV–VI was in the range of 0.19–0.47. Conclusion: Lymph nodes with an axial short-axis diameter exceeding 15 mm for Level II and 10 mm for all other cervical levels are uncommon in otherwise healthy children.
- 1 December 2019
- Published by Elsevier in European Journal of Radiology
- Vol. 121, 108737
Fused high b-value diffusion weighted and T2-weighted MR images in staging of pediatric Hodgkin’s lymphoma: A pilot study
- 1 December 2019
- Published by Elsevier in European Journal of Radiology
- Vol. 121, 108737
Fused high b-value diffusion weighted and T2-weighted MR images in staging of pediatric Hodgkin’s lymphoma: A pilot study
- Open Access
- 5 December 2018
- Published by Springer Nature in Pediatric Radiology
- Vol. 49 (2) , 266-276
Imaging features of extranodal involvement in paediatric Hodgkin lymphoma
Detecting extranodal disease in paediatric Hodgkin lymphoma is of great importance for both treatment and prognosis. Different imaging techniques can be used to identify these extranodal sites. This pictorial essay provides an overview of imaging features of extranodal disease manifestation in paediatric Hodgkin lymphoma.
- 5 December 2018
- Published by Springer Nature in Pediatric Radiology
- Vol. 49 (2) , 266-276
Open AccessImaging features of extranodal involvement in paediatric Hodgkin lymphoma
Detecting extranodal disease in paediatric Hodgkin lymphoma is of great importance for both treatment and prognosis. Different imaging techniques can be used to identify these extranodal sites. This pictorial essay provides an overview of imaging features of extranodal disease manifestation in paediatric Hodgkin lymphoma.
- Open Access
- 13 May 2017
- Published by S. Karger AG in Gynecologic and Obstetric Investigation
- Vol. 82 (6) , 538-546
Fresh and Frozen-Thawed Embryo Transfer Compared to Natural Conception: Differences in Perinatal Outcome
Background/Aim: To compare the pregnancy outcome of singletons conceived after transfer of cryopreserved and thawed embryos (frozen embryo transfer [FET]) to singletons conceived after fresh embryo transfer (fresh ET) and natural conceived singletons. Methods: Using a retrospective data analysis on a study population consisting of 1,261 singletons born after FET and 2,519 singletons born after fresh ET between 2006 and 2015. The control group consisted of singletons born after natural conception. Main outcome measures consisted of birth weight (in grams), gestational age, preterm birth (Results: Babies born after FET had an increased risk of high birth weight (adjusted OR [AOR]) 2.92; 1.503-3.482) and being LGA (AOR fresh ET vs. FET 1.47; 1.210-1.787) compared to singletons born after fresh ET, as well as higher birth weights compared to natural conceived children. Conclusions: Singletons born after FET have a higher risk of high birth weight and being LGA compared to singletons after fresh ET and compared to natural conceived singletons. We assume that the freezing process might be the underlying cause.
- 13 May 2017
- Published by S. Karger AG in Gynecologic and Obstetric Investigation
- Vol. 82 (6) , 538-546
Open AccessFresh and Frozen-Thawed Embryo Transfer Compared to Natural Conception: Differences in Perinatal Outcome
Background/Aim: To compare the pregnancy outcome of singletons conceived after transfer of cryopreserved and thawed embryos (frozen embryo transfer [FET]) to singletons conceived after fresh embryo transfer (fresh ET) and natural conceived singletons. Methods: Using a retrospective data analysis on a study population consisting of 1,261 singletons born after FET and 2,519 singletons born after fresh ET between 2006 and 2015. The control group consisted of singletons born after natural conception. Main outcome measures consisted of birth weight (in grams), gestational age, preterm birth (Results: Babies born after FET had an increased risk of high birth weight (adjusted OR [AOR]) 2.92; 1.503-3.482) and being LGA (AOR fresh ET vs. FET 1.47; 1.210-1.787) compared to singletons born after fresh ET, as well as higher birth weights compared to natural conceived children. Conclusions: Singletons born after FET have a higher risk of high birth weight and being LGA compared to singletons after fresh ET and compared to natural conceived singletons. We assume that the freezing process might be the underlying cause.