Daisuke Akamatsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daisuke Akamatsu has a total of 226 co-authors. Here are the top co-authors by number of shared publications:
- Feng-Lei Hong
Yokohama National University
55 shared publications - Masami Yasuda
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan
36 shared publications - Hajime Inaba
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan
34 shared publications Kazumoto Hosaka
National Institute of Advanced Industrial Science and Technology (AIST)
29 shared publications- Takumi Kobayashi
National Institute of Standards and Technology
26 shared publications Atsushi Onae
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central 3, Ibaraki 305-8563, Japan
23 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by IOP Publishing in Applied Physics Express
- Vol. 19 (8) , 082001
Phase noise suppression in an optical-fiber-based interferometer using ultralow-noise lasers for quantum communication
The frequency noise of an external-cavity diode laser locked to an ultralow-expansion cavity (cavity-stabilized laser) and a whispering-gallery-mode (WGM) cavity optical-feedback semiconductor laser (WGM laser) was evaluated. The frequency noise of the WGM laser was approximately two orders of magnitude smaller than that of the cavity-stabilized laser at high Fourier frequencies. Using the WGM laser, phase noise reduction of approximately two orders of magnitude was observed in the dual-band stabilization of an optical-fiber-based interferometer at high Fourier frequencies. This noise reduction should improve the measurement fidelity in quantum key and entanglement distributions in long-distance quantum communication.
- 1 August 2026
- Published by IOP Publishing in Applied Physics Express
- Vol. 19 (8) , 082001
Open AccessPhase noise suppression in an optical-fiber-based interferometer using ultralow-noise lasers for quantum communication
The frequency noise of an external-cavity diode laser locked to an ultralow-expansion cavity (cavity-stabilized laser) and a whispering-gallery-mode (WGM) cavity optical-feedback semiconductor laser (WGM laser) was evaluated. The frequency noise of the WGM laser was approximately two orders of magnitude smaller than that of the cavity-stabilized laser at high Fourier frequencies. Using the WGM laser, phase noise reduction of approximately two orders of magnitude was observed in the dual-band stabilization of an optical-fiber-based interferometer at high Fourier frequencies. This noise reduction should improve the measurement fidelity in quantum key and entanglement distributions in long-distance quantum communication.
- Open Access
- 25 May 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (21)
Quantum storage of frequency-multiplexed photons exhibiting nonclassical correlations with telecom C-band photons
Multiplexing is essential for improving entanglement distribution rates in quantum communication. Frequency multiplexing provides a promising and scalable path toward large-capacity quantum networks. Further progress requires increasing the number of frequency modes and developing broadband photon-pair sources and quantum memories that are spectrally compatible. Here, we report the integration of a cavity-enhanced spontaneous parametric downconversion source in the telecom C-band with a frequency-multiplexed atomic frequency-comb memory. The bow-tie cavity source was simultaneously resonant at 606 and 1550 nm, generating non-degenerate photon pairs exhibiting a clustered frequency-comb spectrum. The atomic frequency-comb memory, implemented in a Praseodymium-doped Yttrium Orthosilicate crystal, provided up to 83 frequency modes with 123 MHz spacing and enabled broadband storage of 606 nm signal photons. By filtering the main cluster, we obtained 32.7±4.8 effective modes, as confirmed from coincidence measurements. Importantly, we observed strong nonclassical correlations after storage, with cross correlation values of gs,i(2)=8.1±0.7. Our experimental results demonstrate the feasibility of integrating cavity-enhanced photon-pair sources with rare-earth-ion-doped solid-state memories. The integration reveals a high frequency multiplicity that is essential for scalable quantum networks.
- 25 May 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (21)
Open AccessQuantum storage of frequency-multiplexed photons exhibiting nonclassical correlations with telecom C-band photons
Multiplexing is essential for improving entanglement distribution rates in quantum communication. Frequency multiplexing provides a promising and scalable path toward large-capacity quantum networks. Further progress requires increasing the number of frequency modes and developing broadband photon-pair sources and quantum memories that are spectrally compatible. Here, we report the integration of a cavity-enhanced spontaneous parametric downconversion source in the telecom C-band with a frequency-multiplexed atomic frequency-comb memory. The bow-tie cavity source was simultaneously resonant at 606 and 1550 nm, generating non-degenerate photon pairs exhibiting a clustered frequency-comb spectrum. The atomic frequency-comb memory, implemented in a Praseodymium-doped Yttrium Orthosilicate crystal, provided up to 83 frequency modes with 123 MHz spacing and enabled broadband storage of 606 nm signal photons. By filtering the main cluster, we obtained 32.7±4.8 effective modes, as confirmed from coincidence measurements. Importantly, we observed strong nonclassical correlations after storage, with cross correlation values of gs,i(2)=8.1±0.7. Our experimental results demonstrate the feasibility of integrating cavity-enhanced photon-pair sources with rare-earth-ion-doped solid-state memories. The integration reveals a high frequency multiplicity that is essential for scalable quantum networks.
- 2 January 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (1) , 295-307
Phase stabilization with triple wavelength bands for single-photon interference in quantum communication
Optical interferometers are crucial for long-distance quantum communications. We propose a novel phase stabilization method employing triple wavelength bands for single-photon interference in optical fiber-based interferometers, incorporating a simplified laser frequency stabilization technique that utilizes a single nonlinear crystal. After stabilization, the residual phase noise of the fiber interferometer was 20 mrad for differential arm lengths (Δ L ) of 0 and 10 m. This represents a 9-fold and 7.5-fold improvement for Δ L = 0 and 10 m, respectively, compared with those observed in previous double-wavelength methods. These findings enhance the visibility and simplicity of quantum key and entanglement distributions in long-distance quantum communication.
- 2 January 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (1) , 295-307
Phase stabilization with triple wavelength bands for single-photon interference in quantum communication
Optical interferometers are crucial for long-distance quantum communications. We propose a novel phase stabilization method employing triple wavelength bands for single-photon interference in optical fiber-based interferometers, incorporating a simplified laser frequency stabilization technique that utilizes a single nonlinear crystal. After stabilization, the residual phase noise of the fiber interferometer was 20 mrad for differential arm lengths (Δ L ) of 0 and 10 m. This represents a 9-fold and 7.5-fold improvement for Δ L = 0 and 10 m, respectively, compared with those observed in previous double-wavelength methods. These findings enhance the visibility and simplicity of quantum key and entanglement distributions in long-distance quantum communication.
- 23 September 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (28) , 8187-8190
Development of a frequency-stabilized pump source at 436 nm for 606 nm–1.5 µm entangled photon pair generation
We developed a frequency-stable laser light source operating at 436 nm to produce entangled photon pairs at 606 nm and 1.5 µm via spontaneous parametric down conversion. This light source was produced via the sum frequency generation of two lasers operating at 852 and 895 nm, each stabilized to the D2 and D1 transitions of cesium atoms, respectively. We evaluated the frequency stability of the light source using heterodyne measurements between two identical setups. The developed light source can be used to generate frequency-stable photon pairs, a critical requirement for quantum repeaters using Pr:YSO quantum memories.
- 23 September 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (28) , 8187-8190
Development of a frequency-stabilized pump source at 436 nm for 606 nm–1.5 µm entangled photon pair generation
We developed a frequency-stable laser light source operating at 436 nm to produce entangled photon pairs at 606 nm and 1.5 µm via spontaneous parametric down conversion. This light source was produced via the sum frequency generation of two lasers operating at 852 and 895 nm, each stabilized to the D2 and D1 transitions of cesium atoms, respectively. We evaluated the frequency stability of the light source using heterodyne measurements between two identical setups. The developed light source can be used to generate frequency-stable photon pairs, a critical requirement for quantum repeaters using Pr:YSO quantum memories.
- 2 September 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (9)
Frequency measurement of hyperfine transitions of the R(158)25-0 iodine line near the 1S0–3P1 transition of 174Yb
The a10 hyperfine transition of the R(158)25-0 line in molecular iodine serves as a viable optical frequency reference for laser cooling of 174Yb via the 1S0–3P1 intercombination transition at 556 nm. This study reports a frequency measurement of the a10 transition using an optical frequency comb, with an uncertainty of approximately 9 kHz. Additional hyperfine transitions of the R(158)25-0 line were also characterized, and a theoretical analysis of the hyperfine structure was conducted. These results facilitate laser-cooling experiments involving 174Yb and contribute to the spectroscopic understanding of molecular iodine.
- 2 September 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (9)
Frequency measurement of hyperfine transitions of the R(158)25-0 iodine line near the 1S0–3P1 transition of 174Yb
The a10 hyperfine transition of the R(158)25-0 line in molecular iodine serves as a viable optical frequency reference for laser cooling of 174Yb via the 1S0–3P1 intercombination transition at 556 nm. This study reports a frequency measurement of the a10 transition using an optical frequency comb, with an uncertainty of approximately 9 kHz. Additional hyperfine transitions of the R(158)25-0 line were also characterized, and a theoretical analysis of the hyperfine structure was conducted. These results facilitate laser-cooling experiments involving 174Yb and contribute to the spectroscopic understanding of molecular iodine.
- Open Access
- 12 June 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (6) , 843
Coordinated international comparisons between optical clocks connected via fiber and satellite links
Optical clocks provide ultraprecise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time to our knowledge, while others had significantly lower uncertainties than previously achieved, supporting the advance toward a redefinition of the second and the use of optical standards for international time scales.
- 12 June 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (6) , 843
Open AccessCoordinated international comparisons between optical clocks connected via fiber and satellite links
Optical clocks provide ultraprecise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time to our knowledge, while others had significantly lower uncertainties than previously achieved, supporting the advance toward a redefinition of the second and the use of optical standards for international time scales.
- 1 June 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (6) , 062004
Enhancing dual-band stabilization for twin-field quantum key distribution using laser frequency stabilization
Twin-field quantum key distribution (TF-QKD) has attracted considerable attention in quantum communication for the extension of secure communication distance. In TF-QKD, precise photon phase control is required and has been realized using dual-band stabilization (DBS). In this study, we performed residual phase noise reduction in DBS using laser frequency stabilization. The achieved frequency stability of the light sources was better than 1 × 10−12 when the averaging time is larger than 1 s, indicating that the laser frequency variation was less than 200 Hz at 1.5 μm. The integrated phase noise at 1 s was less than 200 mrad, and the corresponding quantum bit error rate at 1 s was less than 1% after applying laser frequency stabilization. This result demonstrates that the stringent phase stability requirements in TF-QKD can be achieved without relying on complex optical frequency combs, enabling a simpler and more cost-effective experimental setup.
- 1 June 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (6) , 062004
Enhancing dual-band stabilization for twin-field quantum key distribution using laser frequency stabilization
Twin-field quantum key distribution (TF-QKD) has attracted considerable attention in quantum communication for the extension of secure communication distance. In TF-QKD, precise photon phase control is required and has been realized using dual-band stabilization (DBS). In this study, we performed residual phase noise reduction in DBS using laser frequency stabilization. The achieved frequency stability of the light sources was better than 1 × 10−12 when the averaging time is larger than 1 s, indicating that the laser frequency variation was less than 200 Hz at 1.5 μm. The integrated phase noise at 1 s was less than 200 mrad, and the corresponding quantum bit error rate at 1 s was less than 1% after applying laser frequency stabilization. This result demonstrates that the stringent phase stability requirements in TF-QKD can be achieved without relying on complex optical frequency combs, enabling a simpler and more cost-effective experimental setup.
- 4 March 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (2) , 025006
Improved absolute frequency measurement of 171Yb at NMIJ with uncertainty below 2 × 10 − 16
We report improved absolute frequency measurement of the 1S 0 − 3 P0 transition of 171Yb at National Metrology Institute of Japan (NMIJ) by comparing the 171Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary frequency standards via International Atomic Time from August 2021 to May 2023. The measured absolute frequency is 518 295 836 590 863.62(10) Hz with a fractional uncertainty of 1.9 × 10 − 16 , in good agreement with the recommended frequency of 171Yb as a secondary representation of the second. This uncertainty is 2.6 times lower than our previous measurement uncertainty, and slightly lower than any uncertainties of the absolute frequency measurements of 171Yb that have so far been reported by other institutes. We also estimate correlation coefficients between our present and previous measurements, which is important for updating the recommended frequency.
- 4 March 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (2) , 025006
Improved absolute frequency measurement of 171Yb at NMIJ with uncertainty below 2 × 10 − 16
We report improved absolute frequency measurement of the 1S 0 − 3 P0 transition of 171Yb at National Metrology Institute of Japan (NMIJ) by comparing the 171Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary frequency standards via International Atomic Time from August 2021 to May 2023. The measured absolute frequency is 518 295 836 590 863.62(10) Hz with a fractional uncertainty of 1.9 × 10 − 16 , in good agreement with the recommended frequency of 171Yb as a secondary representation of the second. This uncertainty is 2.6 times lower than our previous measurement uncertainty, and slightly lower than any uncertainties of the absolute frequency measurements of 171Yb that have so far been reported by other institutes. We also estimate correlation coefficients between our present and previous measurements, which is important for updating the recommended frequency.
- 1 February 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (2) , 022005
Development of a 1 Hz relative linewidth Er:fiber comb utilizing a semiconductor saturable absorber mirror
An Er:fiber comb based on a mode-locked Er:fiber laser was developed, employing a semiconductor saturable absorber mirror and an intra-cavity electro-optic modulator. The carrier-envelope offset frequency of the comb was phase-locked with a servo bandwidth of 60 kHz using a divide-by-10 frequency divider. Subsequently, the Er:fiber comb was phase-locked to an iodine-stabilized Nd:YAG laser with a servo bandwidth of 550 kHz, without the necessity of a frequency divider. Furthermore, the relative linewidth of the developed Er:fiber comb was evaluated by comparing it with another optical frequency comb, confirming that the relative linewidth was less than 1 Hz.
- 1 February 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (2) , 022005
Development of a 1 Hz relative linewidth Er:fiber comb utilizing a semiconductor saturable absorber mirror
An Er:fiber comb based on a mode-locked Er:fiber laser was developed, employing a semiconductor saturable absorber mirror and an intra-cavity electro-optic modulator. The carrier-envelope offset frequency of the comb was phase-locked with a servo bandwidth of 60 kHz using a divide-by-10 frequency divider. Subsequently, the Er:fiber comb was phase-locked to an iodine-stabilized Nd:YAG laser with a servo bandwidth of 550 kHz, without the necessity of a frequency divider. Furthermore, the relative linewidth of the developed Er:fiber comb was evaluated by comparing it with another optical frequency comb, confirming that the relative linewidth was less than 1 Hz.
- Open Access
Optical Frequency References at 1542 nm: Precision Spectroscopy of the R(106)50-0, R(100)49-0, R(84)47-0, R(59)45-0, P(82)47-0, and P(71)46-0 Lines of 127I2 at 514 nm
Frequency-stabilized lasers are fundamental topics in research relating to optical frequency and wavelength standards. The absolute frequencies and hyperfine structures of the R(106)50-0, R(100)49-0, R(84)47-0, R(59)45-0, P(82)47-0, and P(71)46-0 lines of molecular iodine (127I2) at 514 nm were measured using a frequency-stabilized laser based on modulation transfer spectroscopy. The hyperfine splitting of each line was fitted to a four-term Hamiltonian with an uncertainty of several kilohertz to obtain the hyperfine constants for the line. A total of 97 hyperfine transitions of the six lines were measured with an uncertainty of 5.6 kHz (fractionally 9.6 × 10−12). They can provide new optical frequency references for telecommunication and other applications.
Open AccessOptical Frequency References at 1542 nm: Precision Spectroscopy of the R(106)50-0, R(100)49-0, R(84)47-0, R(59)45-0, P(82)47-0, and P(71)46-0 Lines of 127I2 at 514 nm
Frequency-stabilized lasers are fundamental topics in research relating to optical frequency and wavelength standards. The absolute frequencies and hyperfine structures of the R(106)50-0, R(100)49-0, R(84)47-0, R(59)45-0, P(82)47-0, and P(71)46-0 lines of molecular iodine (127I2) at 514 nm were measured using a frequency-stabilized laser based on modulation transfer spectroscopy. The hyperfine splitting of each line was fitted to a four-term Hamiltonian with an uncertainty of several kilohertz to obtain the hyperfine constants for the line. A total of 97 hyperfine transitions of the six lines were measured with an uncertainty of 5.6 kHz (fractionally 9.6 × 10−12). They can provide new optical frequency references for telecommunication and other applications.