Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Riccardo Ferrero has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A GPU-Accelerated MRI Simulator for Synthetic Image Generation

    by Riccardo Ferrero, Marta Vicentini, Elizabeth Cooke, Cormac McGrath, Aaron McCann, Amy McDowell, Nick Zafeiropoulos, Paul Tofts, Matt G. Hall, Alessandra Manzin

    Magnetic Resonance Imaging (MRI) is an imaging technique that provides detailed structural and functional information about organs and tissues. To support the validation of MRI measurement techniques and provide a tool for scanner benchmarking, we develop an MRI simulator exploiting graphics processing units (GPUs) for computational acceleration. The GPU-Accelerated MRI Simulator (GAMS) enables us to generate synthetic images with high-resolution detail for quantitative estimation of relaxation times. GAMS is designed to reproduce the entire MRI image acquisition pipeline, including the definition of the MRI pulse sequence in a standard Pulseq format, the input of the digital phantom and its voxelization, the time integration of the Bloch equation at voxel level, and the processing of the derived k-space for image synthesis. The Bloch equation solver is implemented in CUDA Fortran, using GPUs to increase computational efficiency. The solver accuracy is tested in simple cases by comparison with analytical solutions and with the open-source Jülich Extensible MRI Simulator (JEMRIS). GAMS is applied to an inverse reconstruction problem to estimate the relaxation properties of a calibration phantom, starting with synthetic data. Then, it is used to reproduce the imaging process of a high-resolution digital brain phantom, generating realistic images under diverse MRI pulse sequences, which enable differentiation of tissues based on relaxation properties and/or proton density. The results demonstrate GAMS’s ability to generate synthetic images of complex anatomical structures comparable to those acquired with real MRI scanners and to reliably quantify sample relaxation properties. The simulator is also characterized by high computational efficiency, extensibility for multi-GPU implementation, and cross-platform compatibility. These features make GAMS a valuable tool for the metrological assessment of quantitative MRI (qMRI) and the testing of new pulse sequences for qMRI technique development.

  • Open Access

    Image-based reconstruction of anthropomorphic breast phantoms for synthetic mammogram generation

    by Martina Oria, Riccardo Ferrero, Chiara Andreis, Marta Vicentini, Ruben van Engen, Carlijn Roozemond, Paola Lamberti, Sara Remogna, Alessandra Manzin


  • Open Access

    From data to nutrition: the impact of computing infrastructure and artificial intelligence

    by Pierpaolo Di Bitonto, Michele Magarelli, Pierfrancesco Novielli, Donato Romano, Domenico Diacono, Lorenzo de Trizio, Angelo Mariano, Claudia Zoani, Riccardo Ferrero, Alessandra Manzin, et al.

    This article explores the significant impact that artificial intelligence (AI) could have on food safety and nutrition, with a specific focus on the use of machine learning and neural networks for disease risk prediction, diet personalization, and food product development. Specific AI techniques and explainable AI (XAI) are highlighted for their potential in personalizing diet recommendations, predicting models for disease prevention, and enhancing data-driven approaches to food production. The article also underlines the importance of high-performance computing infrastructures and data management strategies, including data operations (DataOps) for efficient data pipelines and findable, accessible, interoperable, and reusable (FAIR) principles for open and standardized data sharing. Additionally, it explores the concept of open data sharing and the integration of machine learning algorithms in the food industry to enhance food safety and product development. It highlights the METROFOOD-IT project as a best practice example of implementing advancements in the agri-food sector, demonstrating successful interdisciplinary collaboration. The project fosters both data security and transparency within a decentralized data space model, ensuring reliable and efficient data sharing. However, challenges such as data privacy, model interoperability, and ethical considerations remain key obstacles. The article also discusses the need for ongoing interdisciplinary collaboration between data scientists, nutritionists, and food technologists to effectively address these challenges. Future research should focus on refining AI models to improve their reliability and exploring how to integrate these technologies into everyday nutritional practices for better health outcomes.


  • Open Access

    Influence of size, volume concentration and aggregation state on magnetic nanoparticle hyperthermia properties versus excitation conditions

    by Riccardo Ferrero, Marta Vicentini, Alessandra Manzin

    A micromagnetic model is used to evaluate the heating properties of Fe3O4 nanoparticles versus size, concentration, aggregation order, and AC magnetic field parameters. The obtained data can guide nanoparticle design in view of hyperthermia application.


  • Open Access

    In Silico Experiments to Explore the Heating Efficiency of Magnetic Nanoparticles in Hyperthermia Preclinical Tests

    by Marta Vicentini, Riccardo Ferrero, Alessandra Manzin

    Preclinical tests on murine models are typically performed to evaluate the therapeutic efficacy of novel magnetic nanoparticles (MNPs) in cancer treatment with magnetic hyperthermia. Here, through in silico experiments, in vivo tests are mimicked on a 30 g mouse and a 500 g rat, with the aim of determining the optimal treatment conditions allowing to reach the therapeutic temperature range (40−45 °C) within tumor regions. Various types of MNPs are considered with very different heating properties in terms of specific loss power, varying their administered dose, as well as the frequency and peak amplitude of the magnetic field. The analysis is performed by means of finite element models that solve the low‐frequency electromagnetic (EM) field problem and the Pennes’ bioheat transfer equation, to calculate the temperature increase in biological tissues due to the combined effects of EM field exposure and MNP activation. The methodology, which can be generalized to any type of MNPs, has permitted to identify the proper doses of MNPs to be administered to the tumor region, as a function of their heating properties and magnetic field parameters, highlighting the conditions that can lead to possible overheating, generation of hot spots or magnetic hyperthermia inefficacy.


  • Open Access

    Design and Validation of Experimental Setup for Cell Spheroid Radiofrequency-Induced Heating

    by Ioannis Androulakis, Riccardo Ferrero, Rogier van Oossanen, Alessandra Manzin, Antonia G. Denkova, Kristina Djanashvili, Robin Nadar, Gerard C. van Rhoon

    While hyperthermia has been shown to induce a variety of cytotoxic and sensitizing effects on cancer tissues, the thermal dose–effect relationship is still not well quantified, and it is still unclear how it can be optimally combined with other treatment modalities. Additionally, it is speculated that different methods of applying hyperthermia, such as water bath heating or electromagnetic energy, may have an effect on the resulting biological mechanisms involved in cell death or in sensitizing tumor cells to other oncological treatments. In order to further quantify and characterize hyperthermia treatments on a cellular level, in vitro experiments shifted towards the use of 3D cell spheroids. These are in fact considered a more representative model of the cell environment when compared to 2D cell cultures. In order to perform radiofrequency (RF)-induced heating in vitro, we have recently developed a dedicated electromagnetic field applicator. In this study, using this applicator, we designed and validated an experimental setup which can heat 3D cell spheroids in a conical polypropylene vial, thus providing a reliable instrument for investigating hyperthermia effects at the cellular scale.


  • Open Access

    Application of Magnonic Crystals in Magnetic Bead Detection

    by Alessandra Manzin, Riccardo Ferrero, Marta Vicentini

    This paper aims at studying a sensor concept for possible integration in magnetic field-based lab-on-chip devices that exploit ferromagnetic resonance (FMR) phenomena in magnonic crystals. The focus is on 2D magnetic antidot arrays, i.e., magnetic thin films with periodic non-magnetic inclusions (holes), recently proposed as magnetic field sensor elements operating in the gigahertz (GHz) range. The sensing mechanism is here demonstrated for magnetic nano/microbeads adsorbed on the surface of permalloy (Ni80Fe20) antidot arrays with a rhomboid lattice structure and variable hole size. Through extensive micromagnetic modelling analysis, it is shown that the antidot arrays can be used as both bead traps and high-sensitivity detectors, with performance that can be tuned as a function of bead size and magnetic moment. A key parameter for the detection mechanism is the antidot array hole size, which affects the FMR frequency shifts associated with the interaction between the magnetization configuration in the nanostructured film and the bead stray field. Possible applications of the proposed device concept include magnetic immunoassays, using magnetic nano/microbeads as probes for biomarker detection, and biomaterial manipulation.


  • In silico evaluation of adverse eddy current effects in preclinical tests of magnetic hyperthermia

    by Marta Vicentini, Marta Vassallo, Riccardo Ferrero, Ioannis Androulakis, Alessandra Manzin


  • Open Access

    Design and Characterization of an RF Applicator for In Vitro Tests of Electromagnetic Hyperthermia

    by Riccardo Ferrero, Ioannis Androulakis, Luca Martino, Robin Nadar, Gerard C. van Rhoon, Alessandra Manzin

    The evaluation of the biological effects of therapeutic hyperthermia in oncology and the precise quantification of thermal dose, when heating is coupled with radiotherapy or chemotherapy, are active fields of research. The reliable measurement of hyperthermia effects on cells and tissues requires a strong control of the delivered power and of the induced temperature rise. To this aim, we have developed a radiofrequency (RF) electromagnetic applicator operating at 434 MHz, specifically engineered for in vitro tests on 3D cell cultures. The applicator has been designed with the aid of an extensive modelling analysis, which combines electromagnetic and thermal simulations. The heating performance of the built prototype has been validated by means of temperature measurements carried out on tissue-mimicking phantoms and aimed at monitoring both spatial and temporal temperature variations. The experimental results demonstrate the capability of the RF applicator to produce a well-focused heating, with the possibility of modulating the duration of the heating transient and controlling the temperature rise in a specific target region, by simply tuning the effectively supplied power.