Nieke Karnaningroem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nieke Karnaningroem has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- A Aliffia
Department of Environmental Engineering, Faculty of Civil, Environmental, and GeoEngineering, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia
1 shared publication A Wicaksono
Environmental Engineering Departement, Faculty of Civil, Environmental, and Geo-Engineering, Institut Teknologi Sepuluh Nopember (ITS), Surabaya, Indonesia
1 shared publicationAgus Slamet
1 shared publication- Budisantoso Wirjodirdjo
Institut Teknologi Sepuluh Nopember
1 shared publication F A Putri
1 shared publication- H. S. Titah
Faculty of Civil, Planning, and Geo Engineering, Institut Teknologi Sepuluh Nopember, Surabaya, East Java
1 shared publication
Latest Publications
- Open Access
- 25 February 2024
- Published by International Journal Labs in Indonesian Journal of Multidisciplinary Science
- Vol. 3 (5)
Analyzing raw water quality of drinking water of Pelayaran River: Tribute to Brantas River
Raw water quality for drinking water is a strategic issue requiring attention and environmental dynamics. River quality changes are crucial for sustainability and monitoring suitability. Kali Pelayaran, a tributary of the Brantas River, is a key source for drinking water in Sidoarjo Regency. The aim of the research is to analyze the water quality status of the Kali Pelayaran river as a basis for mitigating the sustainability of raw drinking water in Sidoarjo Regency. The length of the segment analyzed starts from the upstream branch of the Brantas River which enters the Pelayaran River to the intake of the Tawangsari WTP, a distance of 21 kilometers. The research method that will be implemented is: analyzing the existing condition of the water quality of the Kali Pelayaran river which is divided into 8 segments by measuring the quality status of the river using the Pollutant Index (IP). Next, use the K-means method to create clustering based on the measured level of quality status. The water and sediment quality parameters analyzed were pH, temperature, DO (Dissolved oxygen), BOD (Biological oxygen demand), COD (Chemical oxygen demand), TDS (Total dissolved solids), and TSS (Total suspended solid). Research conclusions was formulated in an integrated manner regarding the description of current conditions and predictions for the future, presented in the form of tables, graphs, and maps.
- 25 February 2024
- Published by International Journal Labs in Indonesian Journal of Multidisciplinary Science
- Vol. 3 (5)
Open AccessAnalyzing raw water quality of drinking water of Pelayaran River: Tribute to Brantas River
Raw water quality for drinking water is a strategic issue requiring attention and environmental dynamics. River quality changes are crucial for sustainability and monitoring suitability. Kali Pelayaran, a tributary of the Brantas River, is a key source for drinking water in Sidoarjo Regency. The aim of the research is to analyze the water quality status of the Kali Pelayaran river as a basis for mitigating the sustainability of raw drinking water in Sidoarjo Regency. The length of the segment analyzed starts from the upstream branch of the Brantas River which enters the Pelayaran River to the intake of the Tawangsari WTP, a distance of 21 kilometers. The research method that will be implemented is: analyzing the existing condition of the water quality of the Kali Pelayaran river which is divided into 8 segments by measuring the quality status of the river using the Pollutant Index (IP). Next, use the K-means method to create clustering based on the measured level of quality status. The water and sediment quality parameters analyzed were pH, temperature, DO (Dissolved oxygen), BOD (Biological oxygen demand), COD (Chemical oxygen demand), TDS (Total dissolved solids), and TSS (Total suspended solid). Research conclusions was formulated in an integrated manner regarding the description of current conditions and predictions for the future, presented in the form of tables, graphs, and maps.
- Open Access
- 13 November 2023
- Published by Ridwan Institute in Asian Journal of Engineering, Social and Health
- Vol. 2 (11) , 1521-1530
The Environmental Impact of Leachate Processing Installations: Life Cycle Assessment (LCA) Study
This study aims to analyze waste management in the face of population growth and increasing human activity. As the population continues to grow and human activities intensify, the proper management of waste becomes crucial to safeguarding the environment. In this context, leachate treatment through the Leachate Treatment Plant (LTP) emerges as a key element in protecting the environment from the negative impacts of leachate. The Life Cycle Assessment (LCA) method serves as a valuable tool for analyzing the environmental implications of LTPs and aiding in sustainable decision-making. The research process commences with gathering essential data and constructing an inventory related to energy use, greenhouse gas emissions, water pollution loads, and the utilization of natural resources. Through the gate-to-gate approach using the SimaPro application with the CML-IA Baseline method, the environmental impacts are quantified. The study reveals the significant impacts of Global warming (3.03E-08 Pt), Photochemical Oxidation (3.70E-09 Pt), Human toxicity (2.09E-09 Pt), and Eutrophication (1.87E-06 Pt). Eutrophication stands out as the most prominent impact of wastewater treatment. The resultant eutrophication impact predominantly originates from the Biological Oxygen Demand (BOD) pollutant component, mainly generated from the equalization tub unit and constructed wetland. Furthermore, the control tank emerges as the primary source of the dominant pollutant.
- 13 November 2023
- Published by Ridwan Institute in Asian Journal of Engineering, Social and Health
- Vol. 2 (11) , 1521-1530
Open AccessThe Environmental Impact of Leachate Processing Installations: Life Cycle Assessment (LCA) Study
This study aims to analyze waste management in the face of population growth and increasing human activity. As the population continues to grow and human activities intensify, the proper management of waste becomes crucial to safeguarding the environment. In this context, leachate treatment through the Leachate Treatment Plant (LTP) emerges as a key element in protecting the environment from the negative impacts of leachate. The Life Cycle Assessment (LCA) method serves as a valuable tool for analyzing the environmental implications of LTPs and aiding in sustainable decision-making. The research process commences with gathering essential data and constructing an inventory related to energy use, greenhouse gas emissions, water pollution loads, and the utilization of natural resources. Through the gate-to-gate approach using the SimaPro application with the CML-IA Baseline method, the environmental impacts are quantified. The study reveals the significant impacts of Global warming (3.03E-08 Pt), Photochemical Oxidation (3.70E-09 Pt), Human toxicity (2.09E-09 Pt), and Eutrophication (1.87E-06 Pt). Eutrophication stands out as the most prominent impact of wastewater treatment. The resultant eutrophication impact predominantly originates from the Biological Oxygen Demand (BOD) pollutant component, mainly generated from the equalization tub unit and constructed wetland. Furthermore, the control tank emerges as the primary source of the dominant pollutant.
- Open Access
- 25 December 2019
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in IPTEK Journal of Proceedings Series
- No. 5,p. 225
Evaluation of Water Losses: Study Case in Intan Banjar Water Supply Company
Water losses from water distribution networks have become a crucial problem. The BNA (Basic Need Approach) zone has high water losses above the standard for maximum tolerance ministry of public work as 20%. The water losses during September - December 2018 has experienced a fluctuation. the highest losses occurred in October at 36.05%, but in November the level of water losses decreased to 34.17%. The water balance can be used to know to understand the quantity, source, and charge of water losses. The water balance calculation in this study uses the WB-Easy Calc program version 4.05. Based on the result, the percentage of water losses 34,81% with the composition of real losses as 30,61% and apparent losses of 4.21%. On the other hand, the financial impact by the water losses was deficit as Rp. 4.593.648.335. Furthermore, gets to the action for each one of the above main components of the water balance in order to reduce water losses.
- 25 December 2019
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in IPTEK Journal of Proceedings Series
- No. 5,p. 225
Open AccessEvaluation of Water Losses: Study Case in Intan Banjar Water Supply Company
Water losses from water distribution networks have become a crucial problem. The BNA (Basic Need Approach) zone has high water losses above the standard for maximum tolerance ministry of public work as 20%. The water losses during September - December 2018 has experienced a fluctuation. the highest losses occurred in October at 36.05%, but in November the level of water losses decreased to 34.17%. The water balance can be used to know to understand the quantity, source, and charge of water losses. The water balance calculation in this study uses the WB-Easy Calc program version 4.05. Based on the result, the percentage of water losses 34,81% with the composition of real losses as 30,61% and apparent losses of 4.21%. On the other hand, the financial impact by the water losses was deficit as Rp. 4.593.648.335. Furthermore, gets to the action for each one of the above main components of the water balance in order to reduce water losses.
- Open Access
- 25 December 2019
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in IPTEK Journal of Proceedings Series
- No. 5,p. 161
Study of the Application of the RCA and Six Sigma Method for Quality of the Kalimas River in Surabaya (Prestasi Park-Petekan Bridge Segment)
Study of the Application of the RCA and Six Sigma Method for Quality of the Kalimas River in Surabaya (Prestasi Park-Petekan Bridge Segment)
- 25 December 2019
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in IPTEK Journal of Proceedings Series
- No. 5,p. 161
Open AccessStudy of the Application of the RCA and Six Sigma Method for Quality of the Kalimas River in Surabaya (Prestasi Park-Petekan Bridge Segment)
Study of the Application of the RCA and Six Sigma Method for Quality of the Kalimas River in Surabaya (Prestasi Park-Petekan Bridge Segment)
- Open Access
- 25 December 2019
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in IPTEK Journal of Proceedings Series
- No. 5,p. 248
Study of Karangpilang II Water Production Quality Control Using Statistical Process Control (SPC)
Study of Karangpilang II Water Production Quality Control Using Statistical Process Control (SPC)
- 25 December 2019
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in IPTEK Journal of Proceedings Series
- No. 5,p. 248
Open AccessStudy of Karangpilang II Water Production Quality Control Using Statistical Process Control (SPC)
Study of Karangpilang II Water Production Quality Control Using Statistical Process Control (SPC)
- Open Access
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 259 (1) , 012013
Minimizing failure risk of refill drinking water production in Rungkut district Surabaya using Failure Mode and Effect Analysis (FMEA)
Human necessity toward consumable drinking water increases along with population growth. People nowadays have a hard time obtaining clean water because of polluted river. To meet daily necessity of drinking water, a lot of industries open drinking water business, particularly refill drinking water facility (DAMIU). The utilization of refill drinking water facility has its own hazardous risk because of the doubtful quality, moreover if the customers aren’t paying attention towards the security and hygiene. This study used FMEA (Failure Mode Effect and Analysis) to determine the priority of failure incident in refill drinking water treatment process. This FMEA method was used because FMEA has advantage over other method in term of being more feasible and effective for operational improvement while being able to analyze risk in bigger and more complex scale. To determine the failure, we first did risk identification which contained failures information obtained from interview, quality test, and direct observation. Failure causes risk happened in refill drinking water facilities were analyzed using Fishbone method. The location of the study was in Rungkut District, Surabaya. The parameters used were turbidity, TDS, pH, and Total Coliform. Obtained risk should had a value to be measured and determined for the handling priority and to find improvement effort. The measurement value was called as RPN (Risk Priority Number) which was the multiply value of severity, occurrence, and detection. Based on analysis result using fishbone method there were 4 factors which caused failure for total coliform parameter. Then, it was analyzed using FMEA method, and it was found that failure happened within 3 highest priority, which was UV system contact duration, ozone system contact duration, and disinfection tool replacement and maintenance.
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 259 (1) , 012013
Open AccessMinimizing failure risk of refill drinking water production in Rungkut district Surabaya using Failure Mode and Effect Analysis (FMEA)
Human necessity toward consumable drinking water increases along with population growth. People nowadays have a hard time obtaining clean water because of polluted river. To meet daily necessity of drinking water, a lot of industries open drinking water business, particularly refill drinking water facility (DAMIU). The utilization of refill drinking water facility has its own hazardous risk because of the doubtful quality, moreover if the customers aren’t paying attention towards the security and hygiene. This study used FMEA (Failure Mode Effect and Analysis) to determine the priority of failure incident in refill drinking water treatment process. This FMEA method was used because FMEA has advantage over other method in term of being more feasible and effective for operational improvement while being able to analyze risk in bigger and more complex scale. To determine the failure, we first did risk identification which contained failures information obtained from interview, quality test, and direct observation. Failure causes risk happened in refill drinking water facilities were analyzed using Fishbone method. The location of the study was in Rungkut District, Surabaya. The parameters used were turbidity, TDS, pH, and Total Coliform. Obtained risk should had a value to be measured and determined for the handling priority and to find improvement effort. The measurement value was called as RPN (Risk Priority Number) which was the multiply value of severity, occurrence, and detection. Based on analysis result using fishbone method there were 4 factors which caused failure for total coliform parameter. Then, it was analyzed using FMEA method, and it was found that failure happened within 3 highest priority, which was UV system contact duration, ozone system contact duration, and disinfection tool replacement and maintenance.
- Open Access
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 259 (1) , 012019
Simulation of pollution load capacity using QUAL2Kw model in Kali Surabaya River (Cangkir-Sepanjang segment)
The Utilization of Kali Surabaya River as water resources for drinking water is constrained by pollution from domestic and industrial waste and agricultural activities around the river banks. This study was aimed to calculate the pollution load capacity using QUAL2Kw model which presented the water quality. Study area from upstream (Cangkir) to downstream (Sepanjang) of the river was divided into 3 segments. The required data included primary data by sampling at determined points representing the condition of pollutant source. Secondary data included climatology, population, river hydraulic, and discharge and quality of pollution obtained from related institution. The water quality parameters analysed were BOD and COD, where the result exceeded the water quality standard of class I, while the DO was less than the standard requirement. Based on the simulation result, the value of pollutant load in each segment for BOD was 12,416 kg/day, 23,180 kg/day, and 17,759 kg/day while COD was 56,158 kg/day, 99,188 kg/day, and 74,316 kg/day. Then, the capacity of BOD in each segment was 1,681 kg/day, 1,138 kg/day, and 1,398 kg/day while COD is 12,396 kg/day, 8,150 kg/day, and 9,681 kg/day. This means that the pollutant load has exceeded the capacity of the river.
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 259 (1) , 012019
Open AccessSimulation of pollution load capacity using QUAL2Kw model in Kali Surabaya River (Cangkir-Sepanjang segment)
The Utilization of Kali Surabaya River as water resources for drinking water is constrained by pollution from domestic and industrial waste and agricultural activities around the river banks. This study was aimed to calculate the pollution load capacity using QUAL2Kw model which presented the water quality. Study area from upstream (Cangkir) to downstream (Sepanjang) of the river was divided into 3 segments. The required data included primary data by sampling at determined points representing the condition of pollutant source. Secondary data included climatology, population, river hydraulic, and discharge and quality of pollution obtained from related institution. The water quality parameters analysed were BOD and COD, where the result exceeded the water quality standard of class I, while the DO was less than the standard requirement. Based on the simulation result, the value of pollutant load in each segment for BOD was 12,416 kg/day, 23,180 kg/day, and 17,759 kg/day while COD was 56,158 kg/day, 99,188 kg/day, and 74,316 kg/day. Then, the capacity of BOD in each segment was 1,681 kg/day, 1,138 kg/day, and 1,398 kg/day while COD is 12,396 kg/day, 8,150 kg/day, and 9,681 kg/day. This means that the pollutant load has exceeded the capacity of the river.
- Open Access
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 259 (1) , 012010
Prediction of water pollution in Kali Surabaya river segment Karangpilang-Ngagel using stella model
Kali Surabaya River is one of the river in Surabaya that use as the water source of PDAM Surabaya. Moreover, Kali Surabaya River takes an important role of society, industry, agriculture and economic commerce in its surrounding area. The increasing of industry and domestic waste that dispose to Kali Surabaya River, causing the degradation of its water quality. From parameters DO, BOD, and COD of Kali Surabaya River, we can look for relation and mutual attachment to determine the class of water body of Kali Surabaya. The method that use in this case is system dynamics using Stella Model. The purpose of this modelling is to identify and determine the relation of DO, BOD and COD value that contains in Kali Surabaya river segment Karangpilang-Ngagel Surabaya, and to determine the class of water body of Kali Surabaya River segment Karangpilang-Ngagel using dynamic system method. The result of this modelling is prediction of DO parameter value that decreasing in 2018 at all three segments. In December 2018, concentration of DO in segment 1 is 3.79 mg/L; in segment 2 is 4.34 mg/L and in segment 3 is 3.72 mg/L. According to the prediction result from this model, DO value at all segments in November and December is still exceed the standard value of class II river standard, which is 4 mg/L. In the other hand, in January until October DO value at all segments is under the standard of class II river standard. The average DO value of Kali Surabaya River in 2018 is in the range of 3.72-4.9 mg/L.
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 259 (1) , 012010
Open AccessPrediction of water pollution in Kali Surabaya river segment Karangpilang-Ngagel using stella model
Kali Surabaya River is one of the river in Surabaya that use as the water source of PDAM Surabaya. Moreover, Kali Surabaya River takes an important role of society, industry, agriculture and economic commerce in its surrounding area. The increasing of industry and domestic waste that dispose to Kali Surabaya River, causing the degradation of its water quality. From parameters DO, BOD, and COD of Kali Surabaya River, we can look for relation and mutual attachment to determine the class of water body of Kali Surabaya. The method that use in this case is system dynamics using Stella Model. The purpose of this modelling is to identify and determine the relation of DO, BOD and COD value that contains in Kali Surabaya river segment Karangpilang-Ngagel Surabaya, and to determine the class of water body of Kali Surabaya River segment Karangpilang-Ngagel using dynamic system method. The result of this modelling is prediction of DO parameter value that decreasing in 2018 at all three segments. In December 2018, concentration of DO in segment 1 is 3.79 mg/L; in segment 2 is 4.34 mg/L and in segment 3 is 3.72 mg/L. According to the prediction result from this model, DO value at all segments in November and December is still exceed the standard value of class II river standard, which is 4 mg/L. In the other hand, in January until October DO value at all segments is under the standard of class II river standard. The average DO value of Kali Surabaya River in 2018 is in the range of 3.72-4.9 mg/L.
- Open Access
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 259 (1) , 012012
Minimizing failure of production quality from refill drinking water in Gubeng District, Surabaya City, using failure mode and effect analysis
Refill water is one important element in filling the increasing drinking water demand. The price offered by refill water depot is significantly lower than packaged water, however, its quality does not meet the standards, and therefore it will potentially affect people’s health. This risk surfaces if refill water depot installation can’t treat raw water as well as the environment surrounding properly. Thus, identification to refill water production failure cause is needed to minimize the possibility of failure happening. Identification and risk analysis processes are based on risk management concept by using Failure Mode and Effect Analysis (FMEA). Failure cause identification is done using fishbone diagram to find the root of the problem causing the failure. The root of the failure will then be given score to determine the biggest risk stated in Risk Priority Number (RPN). RPN value is obtained through multiplying severity, occurrence, and detection. The biggest failure cause in refill water depot is in the disinfection technology used, which is the replacing and contact duration of regulation regarding refill water also causes failure in refill water production process.
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 259 (1) , 012012
Open AccessMinimizing failure of production quality from refill drinking water in Gubeng District, Surabaya City, using failure mode and effect analysis
Refill water is one important element in filling the increasing drinking water demand. The price offered by refill water depot is significantly lower than packaged water, however, its quality does not meet the standards, and therefore it will potentially affect people’s health. This risk surfaces if refill water depot installation can’t treat raw water as well as the environment surrounding properly. Thus, identification to refill water production failure cause is needed to minimize the possibility of failure happening. Identification and risk analysis processes are based on risk management concept by using Failure Mode and Effect Analysis (FMEA). Failure cause identification is done using fishbone diagram to find the root of the problem causing the failure. The root of the failure will then be given score to determine the biggest risk stated in Risk Priority Number (RPN). RPN value is obtained through multiplying severity, occurrence, and detection. The biggest failure cause in refill water depot is in the disinfection technology used, which is the replacing and contact duration of regulation regarding refill water also causes failure in refill water production process.
- Open Access
- 1 February 2019
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 20 (2) , 177-182
The Self-Purification Ability in The Rivers of Banjarmasin, Indonesia
The river water Self-purification capacity is an essential indicator for a healthy river. Various organic and inorganic pollutants, both point sources and nonpoint sources, in most streams in Banjarmasin have been beyond the river self-purification capacity, which causes river water quality...
- 1 February 2019
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 20 (2) , 177-182
Open AccessThe Self-Purification Ability in The Rivers of Banjarmasin, Indonesia
The river water Self-purification capacity is an essential indicator for a healthy river. Various organic and inorganic pollutants, both point sources and nonpoint sources, in most streams in Banjarmasin have been beyond the river self-purification capacity, which causes river water quality...