YIYusuf Ziya Ider

Yusuf Ziya Ider

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yusuf Ziya Ider has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accelerated solution method for 3D phase-based cr-MREPT

    by Mustafa Kaan Çan, Yusuf Ziya İder

    Objective Convection-Reaction equation based Magnetic Resonance Electrical Properties Imaging (cr-MREPT), especially in phase-based form, is one of the most commonly used MREPT methods since it can successfully overcome internal boundary artefacts, does not rely on Transceive Phase Approximation (TPA) and is relatively easy to implement. While the partial differential equation system solved in this method introduces regularization compared to Helmholtz MREPT, it also increases the solution time especially when the method is applied in large 3D volumes and reduces the practicality of the applications. Approach We divide the large 3D volume of interest into smaller regions (local ROIs) for which the solutions can be obtained faster, we then parallelize the solutions of the individual regions and finally combine the results to obtain the whole conductivity distribution. Sensitivities of the reconstructed conductivity at a certain voxel, to the B_1 phase data of nearby voxels and to the Dirichlet Boundary condition imposed at the boundary of the solution region are investigated to determine the optimum size for the small regions. Main Results Conductivity distributions for various phantoms are successfully reconstructed with significantly reduced computational times, and up to approximately 100 times acceleration of the solution is achieved using a 72-core server. This can be further increased with a high-performance computer, where theoretical limit is the solution time for a single local ROI. Significance Multislice reconstruction of large phantoms, such as a human head, is possible within a reasonable solution time with the proposed method. These findings enhance the potential for the practical applications of phase-based cr-MREPT.

  • Bias correction for phase-based cr-MREPT using low resolution B1+ magnitude

    by Mustafa Kaan Çan, Yusuf Ziya Ider

    Objective Full-form Magnetic Resonance Electrical Properties Tomography (MREPT) requires both B 1 + magnitude and phase information. Since B 1 + phase can be obtained faster and with higher SNR compared to B 1 + magnitude, several phase-based methods have been developed for conductivity imaging. However, phase-based methods suffer from a concave bias due to the assumption that ∇ | B 1 + | is negligible in the ROI. Approach In this paper, we re-derive the central equation of phase-based cr-MREPT without assuming that ∇ | B 1 + | is negligible and thus propose a correction method directly integrated into the equation system. Main results Proposed method successfully corrects the concave bias on both simulated and experimental data and significantly increases image quality. Significance The proposed correction method depends on a very low-resolution | B 1 + | map, and therefore the imaging time does not increase significantly for obtaining B 1 + magnitude. Moreover, correction can be achieved using simulated B 1 + magnitude, hence completely removing the additional imaging requirement.


  • SNR Weighting for Shear Wave Speed Reconstruction in Tomoelastography

    by Cemre Ariyurek, Bilal Tasdelen, Yusuf Ziya Ider, Ergin Atalar

    In tomoelastography, to achieve a final wave speed map by combining reconstructions obtained from all spatial directions and excitation frequencies, the use of weights is inevitable. Here, a new weighting scheme, which maximizes the signal‐to‐noise ratio (SNR) of the final wave speed map, has been proposed. To maximize the SNR of the final wave speed map, the use of squares of estimated SNR values of reconstructed individual maps has been proposed. Therefore, derivations of the SNR of the reconstructed wave speed maps have become necessary. Considering the noise on the complex MRI signal, the SNR of the reconstructed wave speed map was formulated by an analytical approach assuming a high SNR, and the results were verified using Monte Carlo simulations (MCSs). It has been assumed that the noise remains approximately Gaussian when the image SNR is high enough, despite the nonlinear operations in tomoelastography inversion. Hence, the SNR threshold was determined by comparing the SNR computed by MCSs and analytical approximations. The weighting scheme was evaluated for accuracy, spatial resolution and SNR performances on simulated phantoms. MR elastography (MRE) experiments on two different phantoms were conducted. Wave speed maps were generated for simulated 3D human abdomen MRE data and experimental human abdomen MRE data. The simulation results demonstrated that the SNR‐weighted inversion improved the SNR performance of the wave speed map by a factor of two compared to the performance of the original (i.e., amplitude‐weighted) reconstruction. In the case of a low SNR, no bias occurred in the wave speed map when SNR weighting was used, whereas 10% bias occurred when the original weighting (i.e., amplitude weighting) was used. Thus, while not altering the accuracy or spatial resolution of the wave speed map with the proposed weighting method, the SNR of the wave speed map has been significantly improved.


  • New approach for designing cVEP BCI stimuli based on superposition of edge responses

    by Muhammad Nabi Yasinzai, Yusuf Ziya Ider

    The purpose of this study is to develop a new methodology for designing stimulus sequences for Brain Computer Interfaces that utilize code modulated Visually Evoked Potentials (cVEP BCIs), based on experimental results regarding the behavior and the properties of the actual EEG responses of the visual system to binary-coded visual stimuli, such that training time is reduced and possible number of targets is increased. EEG from 8 occipital sites is recorded with 2000 sps, in response to visual stimuli presented on a computer monitor with 60 Hz refresh rate. EEG responses of the visual system to black-to-white and white-to-black transitions of a target area on the monitor are recorded for 500 ms, for 160 trials, and signal-averaged to obtain the onset (positive edge) and offset (negative edge) responses, respectively. It is found that both edge responses are delayed by 50 ms and wane completely within 350 ms. These edge responses are then used to generate (predict) the EEG responses to arbitrary binary stimulus sequences using the superposition principle. It is found that the generated and the measured EEG responses to certain (16) simple short sequences (16.67–350 ms) are highly correlated. These ‘optimal short patterns’ are then randomly combined to design the long (120 bit, 2 sec) ‘Superposition Optimized Pulse (SOP)’ sequences, and their EEG response templates are obtained by superposition of the edge responses. A SOP sequence-based Visual Speller BCI application yielded higher accuracy (95.9%) and Information Transfer Rate (ITR) (57.2 bpm), compared to when superposition principle is applied to conventional m-sequences and randomly generated sequences. Training for the BCI application involves only the acquisition of the edge responses and takes less than 4 min. This is the first study in which the EEG templates for cVEP BCI sequences are obtained by the superposition of edge responses.


  • Open Access

    New Approach for Designing cVEP BCI Stimuli Based on Superposition of Edge Responses

    by M. N. Yasinzai, Y. Z. Ider

    The purpose of this study is to develop a new methodology for designing stimulus sequences for cVEP BCI based on experimental studies regarding the behavior and the properties of the actual EEG responses of the visual system to coded visual stimuli, such that training time is reduced and the possible number of targets is increased. EEG from 8 occipital sites is recorded with 2000 samples/sec per channel, in response to visual stimuli presented on a computer monitor with 60Hz refresh rate. Onset and offset EEG responses to long visual stimulus pulses are obtained through 160-trial signal averaging. These edge responses are used to predict the EEG responses to arbitrary stimulus sequences using the superposition principle. A BCI speller which utilizes the target templates generated by this principle is also implemented and tested. It is found that certain short stimulus patterns can be accurately predicted by the superposition principle. BCI sequences that are constructed by combinations of these optimal patterns yield higher accuracy (95.9%) and ITR (57.2 bpm) compared to when the superposition principle is applied to conventional m-sequences and randomly generated sequences. Training time for the BCI application involves only the acquisition of the edge responses and is less than 4 minutes, and a huge number of sequences is possible. This is the first study in which cVEP BCI sequences are designed based on constraints obtained by observing the actual brain responses to several stimulus patterns.

  • A model based investigation of the period doubling behavior in human steady-state visual evoked potentials

    by Yiğit Tuncel, Toygun Başaklar, Yusuf Ziya Ider

    Objective. This study aims at investigating the potential mechanism of period doubling (PD) (subharmonic generation) in human steady-state visual evoked potentials (SSVEPs) by using a mathematical model. Approach. Robinson’s Corticothalamic Model, which includes three main neuronal populations (cortical, thalamic reticular, and thalamic relay neurons) was employed. SSVEP experiments were simulated using this model and dependence of PD behavior in relation to the values of model parameters was investigated. The feedback loop in the model that is responsible for the generation of subharmonic components was thus identified, and this loop was isolated from the rest of the model and analyzed with a describing function approach. Main Results. It has been found in general, for a wide range of parameter values, that if the excitation frequency or half of it is close to the native oscillation frequency of the system, the native oscillation ceases to exist and oscillations at either the excitation frequency or half of it are observed. This observation is in line with the experimental findings except for some discrepancies which are also discussed. The intrathalamic feedback loop is identified to be the potential source of subharmonic oscillations. When isolated from the rest of the model and simulated by itself, it has been found that this feedback loop can show a resonance phenomenon at the subharmonic frequency. By deriving a set of equations based on the necessary conditions for a resonance phenomenon, a semi-analytical method was developed by which one can predict the existence of subharmonic generation for a given set of parameters and stimulus frequency. Significance. This study is the first model-based investigation of the mechanism of subharmonic oscillations. The proposed semi-analytical method can replace extensive time and memory consuming parameter sweep studies.


  • Effects of high stimulus presentation rate on EEG template characteristics and performance of c-VEP based BCIs

    by Toygun Başaklar, Yiğit Tuncel, Yusuf Ziya Ider

    Objective : This study aims at investigating the effects of high stimulus presentation rates on the characteristics of c-VEP responses along with the change in performance depending on the stimulus presentation rate by utilizing a c-VEP based speller BCI. Approach : Twenty subjects participated in three different experiments with refresh rates of 60 Hz (E1), 120 Hz (E2) and 240 Hz (E3), where a 127-bit m-sequence is used. To observe the change in frequency content of c-VEP responses, PSD estimates of c-VEP responses were evaluated. Principal component analysis (PCA) was applied to observe how many distinguishable responses could be evoked with a 127-bit length m-sequence for three different refresh rates. Main Results : Average ITR and accuracy values are 85.87 bits min −1 and 92% for E1, 94.21 bits min −1 and 97% for E2, and 78.65 bits min −1 and 87% for E3 respectively. The c-VEP responses are band-limited although the bandwidth of the input signal significantly increases as the refresh rate increases. The spectral densities of c-VEP templates are concentrated on several frequency intervals, especially for E3, which eventually results in a target misclassification. PCA shows that the number of well distinguishable responses decreases with the increasing refresh rate. Considering all results and observations, we suggest that 120 Hz refresh rate is best to use in BCIs with high number of targets whereas 240 Hz refresh rate may be prefered for low number of targets. Significance: This study mainly investigates the alterations in the characteristics of c-VEP responses according to the stimulus presentation rate which have never been investigated thoroughly before. Our results show that increasing refresh rate does not necessarily increase the overall performance of the system due to the changes in characteristics of c-VEP responses. Further applications and designs of a c-VEP based BCIs will benefit from the observations and results of this study.


  • Use of dielectric padding to eliminate low convective field artifact in cr‐MREPT conductivity images

    by Gulsah Yildiz, Yusuf Ziya Ider

    Purpose Convection–reaction equation‐based magnetic resonance electrical properties tomography (cr‐MREPT) provides conductivity images that are boundary artifact‐free and robust against noise. However, these images suffer from the low convective field (LCF) artifact. We propose to use dielectric pads to alter the transmit magnetic field (B1+), shift the LCF region, and eliminate the LCF artifact. Methods Computer simulations were conducted to analyze the effects of pad electrical properties, pad thickness, pad height, arc angle, and thickness of the pad–object gap. In 3T MR experiments, water pads and BaTiO3 pads were used with agar–saline phantoms. Two data sets (e.g., with the pad located on the left or on the right of the object [phantom]) were acquired, and the corresponding linear systems were simultaneously solved to get LCF artifact‐free conductivity images. Results A pad needed to have 180° arc angle and the same height with the phantom for maximum benefit. Increasing the pad thickness and/or the relative permittivity of the pad increased the LCF shift, whereas excessive amounts of these parameters caused errors in conductivity reconstructions because the effect of neglected Bz terms became noticeable. Conductivity of the pad, on the other hand, had minimal effect on elimination of the LCF artifact. Combining 2 data sets (i.e., with 2 different dielectric pad positions) resulted in more accurate conductivity maps (low L2‐errors) as opposed to no pad or single pad cases in experiments and simulations. Conclusions Using the proposed technique, LCF artifact is significantly removed, and the reconstructed conductivity values are improved.


  • B 1 + phase retrieval for non-quadrature radio frequency excitation and its preliminary application in MR-EPT

    by Gokhan Ariturk, Yusuf Ziya Ider

    Non-quadrature radio frequency (RF) excitation has been widely studied in the fields of RF shimming, local SAR estimation, and MR-EPT with the use of multi-channel transceiver arrays. These studies generally require the retrieval of the complex transmit field ( ), which can be accomplished by acquiring its magnitude and phase in different steps. Magnitude of the transmit field is acquired with the conventional methods which give accurate results for both quadrature and non-quadrature excitations. On the other hand, there is no straightforward method to acquire the absolute phase of the transmit field and generally approximations in MRI experiments are made in order to get it. However, many of these approximations fail in non-quadrature excitation and/or in ultra high fields. In this study, we propose a simple method to acquire the absolute transmit phase in non-quadrature excitation with an eight channel transceiver TEM array for 3 T. The proposed method requires the application of a single additional quadrature drive in order to get the receive phases of the individual channels of the transceiver coil. These receive phases are then subtracted from the transceive phase of the non-quadrature drive experiment to acquire its transmit phase. The developed ideas are tested in the framework of simulations and MRI experiments with the use of four different non-quadrature drive configurations. It has been observed that the simulated and experimentally acquired transmit phase distributions tend to have a strong consensus which supports the validity of the proposed method. Finally, the estimated transmit phase distribution of non-quadrature drive is used in the standard MR-EPT study to get the conductivity reconstructions in order for the validation of its eligibility in MR-EPT studies.


  • bSSFP phase correction and its use in magnetic resonance electrical properties tomography

    by Safa Ozdemir, Yusuf Ziya Ider

    Purpose: Balanced steady‐state free precession (bSSFP) sequence is widely used because of its high SNR and high speed. However, bSSFP images suffer from “banding artifact” caused by B0 inhomogeneity. In this article, we propose a method to remove this artifact in bSSFP phase images and investigate the usage of the corrected phase images in phase‐based magnetic resonance electrical properties tomography (MREPT).Theory and Methods: Two bSSFP phase images, obtained with different excitation frequencies, are collaged to get rid of the regions containing banding artifacts. Phase of the collaged bSSFP image is the sum of the transceive phase of the RF system and an error term that depends on B0 and T2. By using B0 and T2 maps, this error is eliminated from bSSFP phase images by using pixel‐wise corrections. Conductivity maps are obtained from the uncorrected and the corrected phase images using the phase‐based cr‐MREPT method.Results: Phantom and human experiment results of the proposed method are illustrated for both phase images and conductivity maps. It is shown that uncorrected phase images yield unacceptable conductivity images. When only B0 information is used for phase correction conductivity, reconstructions are substantially improved, and yet T2 information is still needed to fully recover accurate and undistorted conductivity images.Conclusions: With the proposed technique, B0 sensitivity of the bSSFP phase images can be removed by using B0 and T2 maps. It is also shown that corrected bSSFP phase images are of sufficient quality to be used in conductivity imaging.