Christopher J. Long
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christopher J. Long has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- James J. Hickman
University of Central Florida
7 shared publications Candace Martin
NanoScience Technology Center University of Central Florida Orlando Florida
3 shared publications- Christopher W. McAleer
NanoScience Technology Center University of Central Florida Orlando Florida USA
3 shared publications - Lee Richard Bridges
NanoScience Technology Center University of Central Florida Orlando Florida USA
3 shared publications - Carlota Oleaga
NanoScience Technology Center University of Central Florida 12424 Research Parkway Suite 400 Orlando FL 32826 USA
2 shared publications Kaveena Autar
Hesperos, Inc., 12501 Research Parkway, Suite 100, Orlando, FL 32826, USA
2 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (18) , 4913-4934
Investigating cannabidiol rescue of stress-induced cognitive impairment and metabolism-driven safety in Human-on-a-Chip® models
This manuscript combined two studies that assessed the effects of cannabidiol (CBD) exposure in distinct organ-on-a-chip models.
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (18) , 4913-4934
Open AccessInvestigating cannabidiol rescue of stress-induced cognitive impairment and metabolism-driven safety in Human-on-a-Chip® models
This manuscript combined two studies that assessed the effects of cannabidiol (CBD) exposure in distinct organ-on-a-chip models.
- Open Access
- 27 September 2025
- Published by Elsevier in Biomedicine & Pharmacotherapy
- Vol. 192, 118556
Developing a functional non-animal CNS stress model utilizing long-term potentiation with human iPSC-cortical neurons to evaluate therapeutics
- 27 September 2025
- Published by Elsevier in Biomedicine & Pharmacotherapy
- Vol. 192, 118556
Open AccessDeveloping a functional non-animal CNS stress model utilizing long-term potentiation with human iPSC-cortical neurons to evaluate therapeutics
- 23 August 2020
- Published by Wiley in Biotechnology Progress
- Vol. 37 (1) , e3069
A functional long‐term 2D serum‐free human hepatic in vitro system for drug evaluation
Human in vitro hepatic models generate faster drug toxicity data with higher human predictability compared to animal models. However, for long‐term studies, current models require the use of serum and 3D architecture, limiting their utility. Maintaining a functional long‐term human in vitro hepatic culture that avoids complex structures and serum would improve the value of such systems for preclinical studies. This would also enable a more straightforward integration with current multi‐organ devices to study human systemic toxicity to generate an alternative model to chronic animal evaluations. A human primary hepatocyte culture system was characterized for 28 days in 2D and serum‐free defined conditions. Under the studied conditions, human primary hepatocytes maintained their characteristic morphology, hepatic markers and functions for 28 days. The acute and chronic administration of known drugs validated the sensitivity of the system for drug testing. This human 2D model represents a realistic system to evaluate hepatic function for long‐term drug studies, without the need of animal serum, confounding variable in most models, and with less complexity and resultant cost compared to most 3D models. The defined culture conditions can easily be integrated into complex multi‐organ in vitro models for studying systemic effects driven by the liver function for long‐term evaluations.
- 23 August 2020
- Published by Wiley in Biotechnology Progress
- Vol. 37 (1) , e3069
A functional long‐term 2D serum‐free human hepatic in vitro system for drug evaluation
Human in vitro hepatic models generate faster drug toxicity data with higher human predictability compared to animal models. However, for long‐term studies, current models require the use of serum and 3D architecture, limiting their utility. Maintaining a functional long‐term human in vitro hepatic culture that avoids complex structures and serum would improve the value of such systems for preclinical studies. This would also enable a more straightforward integration with current multi‐organ devices to study human systemic toxicity to generate an alternative model to chronic animal evaluations. A human primary hepatocyte culture system was characterized for 28 days in 2D and serum‐free defined conditions. Under the studied conditions, human primary hepatocytes maintained their characteristic morphology, hepatic markers and functions for 28 days. The acute and chronic administration of known drugs validated the sensitivity of the system for drug testing. This human 2D model represents a realistic system to evaluate hepatic function for long‐term drug studies, without the need of animal serum, confounding variable in most models, and with less complexity and resultant cost compared to most 3D models. The defined culture conditions can easily be integrated into complex multi‐organ in vitro models for studying systemic effects driven by the liver function for long‐term evaluations.
- 13 December 2019
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 117 (3) , 736-747
A multiplexed in vitro assay system for evaluating human skeletal muscle functionality in response to drug treatment
In vitro systems that mimic organ functionality have become increasingly important tools in drug development studies. Systems that measure the functional properties of skeletal muscle are beneficial to compound screening studies and also for integration into multi‐organ devices. To date, no studies have investigated human skeletal muscle responses to drug treatments at the single myotube level in vitro. This report details a microscale cantilever chip‐based assay system for culturing individual human myotubes. The cantilevers, along with a laser and photo‐detector system, enable measurement of myotube contractions in response to broad‐field electrical stimulation. This system was used to obtain baseline functional parameters for untreated human myotubes, including peak contractile force and time‐to‐fatigue data. The cultured myotubes were then treated with known myotoxic compounds and the resulting functional changes were compared to baseline measurements as well as known physiological responses in vivo. The collected data demonstrate the system's capacity for screening direct effects of compound action on individual human skeletal myotubes in a reliable, reproducible, and non‐invasive manner. Furthermore, it has the potential to be utilized for high‐content screening, disease modeling, and exercise studies of human skeletal muscle performance utilizing iPSCs derived from specific patient populations such as the muscular dystrophies.
- 13 December 2019
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 117 (3) , 736-747
A multiplexed in vitro assay system for evaluating human skeletal muscle functionality in response to drug treatment
In vitro systems that mimic organ functionality have become increasingly important tools in drug development studies. Systems that measure the functional properties of skeletal muscle are beneficial to compound screening studies and also for integration into multi‐organ devices. To date, no studies have investigated human skeletal muscle responses to drug treatments at the single myotube level in vitro. This report details a microscale cantilever chip‐based assay system for culturing individual human myotubes. The cantilevers, along with a laser and photo‐detector system, enable measurement of myotube contractions in response to broad‐field electrical stimulation. This system was used to obtain baseline functional parameters for untreated human myotubes, including peak contractile force and time‐to‐fatigue data. The cultured myotubes were then treated with known myotoxic compounds and the resulting functional changes were compared to baseline measurements as well as known physiological responses in vivo. The collected data demonstrate the system's capacity for screening direct effects of compound action on individual human skeletal myotubes in a reliable, reproducible, and non‐invasive manner. Furthermore, it has the potential to be utilized for high‐content screening, disease modeling, and exercise studies of human skeletal muscle performance utilizing iPSCs derived from specific patient populations such as the muscular dystrophies.
- 19 June 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 11 (497)
Multi-organ system for the evaluation of efficacy and off-target toxicity of anticancer therapeutics
An in vitro multi-organ system evaluates the efficacy and potential off-target toxicities of anticancer parent drugs and metabolites.
- 19 June 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 11 (497)
Multi-organ system for the evaluation of efficacy and off-target toxicity of anticancer therapeutics
An in vitro multi-organ system evaluates the efficacy and potential off-target toxicities of anticancer parent drugs and metabolites.
- Open Access
- 19 February 2019
- Published by Wiley in Advanced Functional Materials
- Vol. 29 (8)
Human‐on‐a‐Chip Systems: Long‐Term Electrical and Mechanical Function Monitoring of a Human‐on‐a‐Chip System (Adv. Funct. Mater. 8/2019)
- 19 February 2019
- Published by Wiley in Advanced Functional Materials
- Vol. 29 (8)
Open AccessHuman‐on‐a‐Chip Systems: Long‐Term Electrical and Mechanical Function Monitoring of a Human‐on‐a‐Chip System (Adv. Funct. Mater. 8/2019)
- Top Cited Papers
- 26 November 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (1) , 330-351
Recent Advances in Body-on-a-Chip Systems
- 26 November 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (1) , 330-351
Top Cited PapersRecent Advances in Body-on-a-Chip Systems