Bayu Andalas
Research Subjects
Bayu Andalas has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Haryoto Kusnoputranto
School of Environmental Science, Universitas Indonesia, 10430, Salemba, Indonesia
1 shared publication- Haryoto Kusnoputranto
Department of Environmental Health Faculty of Public Health Universitas Indonesia Depok Indonesia
1 shared publication Raldi H. Koestoer
School of Environmental Science, Universitas Indonesia, 10430, Salemba, Indonesia
1 shared publication- Raldi Hendrotoro Seputro Koestoer
Environmental Science Study Program, University of Indonesia
1 shared publication - Suyud Warno Utomo
School of Environmental Science, University of Indonesia, Salemba, Jakarta, Indonesia
1 shared publication
Latest Publications
- Open Access
- 1 January 2020
- Published by European Alliance for Innovation n.o.
Spatial Perspective on Thermal Comfort and Energy Consumption: a PLS-SEM approach
Jakarta has implemented Environmentally-friendly buildings and Energy-saving act policy. But the energy consumption in a building is moderately increased all the time. It dominated by consumption in building's air conditioner and related to thermal comfort for building's occupants and also the work performance of civil services employees. This research is providing statistical questionnaire-based of subjective answers by a public service employee of Jakarta Capital Government. This study was conducted by concerning spatial perspective or geographic location of the object in six administrative parts of Jakarta Capital City (center, east, north, west, south and Seribu archipelago). The questions is spreads to 367 buildings occupants during the dry-wet season (October-November). The study were performed in 311 Public service facility, then the data is analyzed by Partial Least Square Structural Equation Modeling (PLS-SEM) method to answer research questions about the link between thermal comfort and energy consumption. The results showed a significant result between two variables. A model using those variables was generated to show the link between them and suggested as a tool to conduct better building-related policies in Jakarta Provincial Government.
- 1 January 2020
- Published by European Alliance for Innovation n.o.
Open AccessSpatial Perspective on Thermal Comfort and Energy Consumption: a PLS-SEM approach
Jakarta has implemented Environmentally-friendly buildings and Energy-saving act policy. But the energy consumption in a building is moderately increased all the time. It dominated by consumption in building's air conditioner and related to thermal comfort for building's occupants and also the work performance of civil services employees. This research is providing statistical questionnaire-based of subjective answers by a public service employee of Jakarta Capital Government. This study was conducted by concerning spatial perspective or geographic location of the object in six administrative parts of Jakarta Capital City (center, east, north, west, south and Seribu archipelago). The questions is spreads to 367 buildings occupants during the dry-wet season (October-November). The study were performed in 311 Public service facility, then the data is analyzed by Partial Least Square Structural Equation Modeling (PLS-SEM) method to answer research questions about the link between thermal comfort and energy consumption. The results showed a significant result between two variables. A model using those variables was generated to show the link between them and suggested as a tool to conduct better building-related policies in Jakarta Provincial Government.
- Open Access
- 12 December 2018
- Published by EDP Sciences
- Vol. 74, 05001
Developing thermal comfort model through regional budget expenditure analysis towards low energy consumption in public building facility (case object: government building in north and south of Jakarta)
Building efficiency policy has implemented Indonesia. However, energy consumption in building sector remains significantly increased. Jakarta Government relied on AC in providing a comfortable condition for its service it consumed 57% of its total energy consumption. Current available energy monitoring method based on the expensive electrical device, so a new method using regional budget expenditure is developed in this research. This study established: Field study (6 buildings), regional budget expenditure analysis (313 buildings) on thermal comfort and building energy in 112 administrative office building equipped with Natural air ventilated (NV) and Air Conditioned (AC) and 224 building occupants/building manager were taking part in this research. Quantitative method used in this research with variables: thermal comfort (Air temperature, Relative humidity, radiant temperature, Air velocity, and personal clothing index) with Fanger’s Predicted Mean Vote (PMV) method calculation. Another variable used in this research is government standard for Building Energy Consumption Index (IKE) through regional government budget analysis. During an early stage, the budget analysis shows 6 out of 112 office buildings energy consumption (electricity) categorised as ‘extravagant.’ Field study higher IKE caused by too cold temperature setting, underperformed Air Conditioning System, building envelope and ventilation or ‘inappropriate’ building orientation (facing east-west).
- 12 December 2018
- Published by EDP Sciences
- Vol. 74, 05001
Open AccessDeveloping thermal comfort model through regional budget expenditure analysis towards low energy consumption in public building facility (case object: government building in north and south of Jakarta)
Building efficiency policy has implemented Indonesia. However, energy consumption in building sector remains significantly increased. Jakarta Government relied on AC in providing a comfortable condition for its service it consumed 57% of its total energy consumption. Current available energy monitoring method based on the expensive electrical device, so a new method using regional budget expenditure is developed in this research. This study established: Field study (6 buildings), regional budget expenditure analysis (313 buildings) on thermal comfort and building energy in 112 administrative office building equipped with Natural air ventilated (NV) and Air Conditioned (AC) and 224 building occupants/building manager were taking part in this research. Quantitative method used in this research with variables: thermal comfort (Air temperature, Relative humidity, radiant temperature, Air velocity, and personal clothing index) with Fanger’s Predicted Mean Vote (PMV) method calculation. Another variable used in this research is government standard for Building Energy Consumption Index (IKE) through regional government budget analysis. During an early stage, the budget analysis shows 6 out of 112 office buildings energy consumption (electricity) categorised as ‘extravagant.’ Field study higher IKE caused by too cold temperature setting, underperformed Air Conditioning System, building envelope and ventilation or ‘inappropriate’ building orientation (facing east-west).