JEJan-Christoph Edelmann

Jan-Christoph Edelmann

*This is an algorithmically generated author record based on publicly available information.

Jan-Christoph Edelmann has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Thomas Ussmueller

    Department of Mechatronics, University of Innsbruck, Innsbruck, Austria

    4 shared publications
  • Dominik Mair

    Microelectronics and Implantable Systems Group, Department of Mechatronics, University of Innsbruck, 6020 Innsbruck, Austria

    2 shared publications
  • Thomas Ussmueller

    A Department of Mechatronics , University of Innsbruck , Innsbruck , Austria

    2 shared publications
  • Daniel Ziesel

    A Department of Mechatronics , University of Innsbruck , Innsbruck , Austria

    1 shared publication
  • Gilbert Prokop

    Microelectronics and Implantable Systems, Institute of Mechatronics, Innsbruck, Tyrol, Austria

    1 shared publication
  • Jasmin Walk

    University of Innsbruck,Institute of Mechatronics, Microelectronics and Implantable Systems,Innsbruck,Tyrol,Austria,6020

    1 shared publication

Latest Publications

  • An e2e Communication System Operating in the Electromagnetic Near Field

    by Jasmin Walk, Jan-Christoph Edelmann, Thomas Ussmueller

    Ear to ear communication (e2e) is an excellent method to improve hearing aids. Given that the human head is inside the radio channel, this presents us with a major challenge, both in terms of efficiency and component geometry. This study provides an inductive communication platform for e2e including the selection of convincing topologies for antenna, transmitter, receiver and amplifier circuits. The test setup reaches 100 kBit/s at a distance of 20 cm. The power consumption amounts to 0.8 mA for transmission and 1.7 mA for reception. To achieve the gain needed for such a large distance, a receiver with a 4-stage amplifier is shown, which reaches 45 dB gain. For transmission a modified Hartley oscillator with OOK is presented which allows inductive counling at $f_{\text{res}}=3.175$ MHz.

  • Can You Hear Me Now?: Challenges and Benefits for Connectivity of Hearing Aids and Implants

    by Jan-Christoph Edelmann, Thomas Ussmueller

    "Pardon me," says grandpa to his adolescent grandson, in a scenario to which nearly every teenager can relate, "but I didn't catch your last sentence." This is not only because teenagers speak fast, mumble, and use "new language." According to the latest World Health Organization (WHO) survey, one in three senior citizens suffers from hearing loss. Among all age groups, a total of 466 million people are affected, which is roughly 5% of the global population. Researchers predict that this number will rise to 900 million people by 2050.


  • A Receiver for Inductive Ear-to-Ear Communication

    by Jan-Christoph Edelmann, Rade Stojakovic, Thomas Ussmueller

    This paper proposes a receiver circuit for inductive ear-to-ear communication. Its input resonance structure, an LCR front-end, is optimized for both a data transmission rate of 100 kbit/s and maximum voltage excess. Following an analytical study, the optimal quality factor Q LCR is found to be 12.8. Subsequent amplification of ON-OFF keyed bits is performed with a four-stage JFET amplifier, introducing a total amplification of 68.6 dB at a sensitivity of 31.6 μV. Each stage is implemented in common-source JFET topology containing a current source in its drain path instead of the conventional drain resistor. This modification allows for a per-stage increase in voltage amplification by a factor of 1.87, avoiding extra quiescent current (detailed circuit theory is added). A hardware realization for signal demodulation reconstructs the baseband signal. In combination with a dedicated transmitter, a Hartley Oscillator, the inductive ear-to-ear transmission system demonstrates a reliable functionality over a distance of 18 cm. Operation is possible with a standard 1.5 V battery cell requiring low currents on a discrete benchtop prototype [transmitter: 0.8 mA; receiver: 4.0 mA]. Applying a carrier frequency of 3.175 MHz, the system is fully compliant with ITU regulation 5.115.

  • Open Access

    An ECG simulator with a novel ECG profile for physiological signals

    by Jan-Christoph Edelmann, Dominik Mair, Daniel Ziesel, Martin Burtscher, Thomas Ussmueller

    This work introduces a low-cost open-source electrocardiography (ECG) simulator comprising both MATLAB software for signal generation and a dedicated circuit board for signal output via a commercial sound card. Synthetic, rate-dependent ECG simulation is based on third-order polynomials that are calculated in sections for the main waves and spikes, respectively. Besides the heart rate, the output profile is fully adjustable with respect to Einthoven lead signals I–III, the amplitudes of the individual ECG waves and spikes, as well as the constitution and intensity of common distortions. The underlying coefficients for the synthetic ECG profile are obtained experimentally by analysing recordings of 22 healthy individuals with heart rates in the range of 40–180 bpm. Eight of these recordings are selected to determine the coefficients for the polynomials (training set) while the remaining 14 serve as test set to evaluate their applicability and accuracy. Thereby, a mean correlation of 98.57% is found which is superior in comparison with a widely accepted rate-dependent ECG profile that is generated from square root and linear terms (correlation score: 91.46%). Although other use-cases are feasible, the focus of this work is the development of an ECG simulator for academic research and university education. Both the MATLAB source code and the circuit layout files are available in the online supplement stimulating further work on this topic.


  • A novel measurement strategy to evaluate the human head as a transition medium for inductive ear-to-ear communication

    by Jan-Christoph Edelmann, Dominik Mair, Thomas Ussmueller

    This manuscript introduces a novel concept for measuring coil coupling for extremely loose-coupled coils (coupling factors k −6 ; mutual inductance values M 50. Measuring these quantities with a low-power technology requires a sophisticated setup that goes beyond the sensitivity of state-of-the art approaches. The methodology is validated using laboratory measurements with three sets of solenoids (two ferrite-cored, one air-cored) and numerical simulations with COMSOL Multiphysics 5.2a, Stockholm, Sweden. The concept is then employed to investigate the channel characteristics for inductive through-the-head communication within the 3.155–3.195 MHz band. This selected part of the spectrum is in accordance with International Telecommunication Union Radio Regulation 5.116 for low-power wireless hearing aids. By applying a phantom solution, we demonstrate that human tissue layers are transparent for magnetic fields within these frequencies. However, the influence from the relative coil arrangement is evaluated in detail as it restricts the communication range significantly. The coupling results for off-the-shelf Sonion, Roskilde, Denmark, RF 02 AA 10 solenoids considering both lateral and axial displacements might be of special interest for a number of near-field applications.

  • Bone Conduction: A Feasible Concept for Ear-to-Ear Communication?

    by Jan-Christoph Edelmann, Gilbert Prokop, Thomas Ussmueller

    This paper evaluates bone conduction as physical implementation for ear-to-ear communication. Applying a pair of B-81 High Output Transducers, a special focus is set on currently commercialized bone conduction modules in implanted systems. A head phantom and PCB circuitry serve as setup to study the individual contributions of inductive flux and mechanical coupling between the transducers over a distance of 15.5 cm. Results show that mechanical coupling dominates up to 5 kHz while inductive coupling is dominant above that frequency. Thus, although such a system would still be functional, we conclude that other approaches might be more effective for the exchange of data between assistive listening devices.