Y. Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Y. Dong has a total of 202 co-authors. Here are the top co-authors by number of shared publications:
M. Fischetti
6 shared publicationsA. Sciubba
5 shared publicationsG. Traini
5 shared publications- Giuseppe Battistoni
National Institute of Nuclear Physics, Section of Milan, Milan, Italy
5 shared publications M. De Simoni
5 shared publicationsS. Muraro
5 shared publications
Latest Publications
- 16 October 2024
- Published by Elsevier in Computer Physics Communications
- Vol. 307
The FLUKA Monte Carlo simulation of the magnetic spectrometer of the FOOT experiment
- 16 October 2024
- Published by Elsevier in Computer Physics Communications
- Vol. 307
The FLUKA Monte Carlo simulation of the magnetic spectrometer of the FOOT experiment
- 11 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 4 (2) , 269-282
Measurement of 12C Fragmentation Cross Sections on C, O, and H in the Energy Range of Interest for Particle Therapy Applications
In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumour and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. These data are also important for the development of the range monitoring techniques with charged particles. The production of charged fragments generated by carbon ion beams of 115-353 MeV/u kinetic energy impinging on carbon, oxygen and hydrogen targets has been measured at the CNAO particle therapy center (Pavia, Italy). The use of thin targets of graphite (C), PMMA (C2O5H8) and polyvinyl-toluene (plastic scintillator, CbHa) allowed to measure fragments production cross sections, exploiting a Time of Flight (ToF) technique. Plastic scintillator detectors have been used to perform the ToF measurements, while LYSO crystals have been used for the deposited energy measurement and to perform particle identification. Cross sections have been measured at 90 and 60 degrees with respect to the beam direction. The measured proton, deuteron and triton differential production cross sections on C, O and H, obtained exploiting the target subtraction strategy, are presented here as a function of the fragment kinetic energy.
- 11 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 4 (2) , 269-282
Measurement of 12C Fragmentation Cross Sections on C, O, and H in the Energy Range of Interest for Particle Therapy Applications
In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumour and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. These data are also important for the development of the range monitoring techniques with charged particles. The production of charged fragments generated by carbon ion beams of 115-353 MeV/u kinetic energy impinging on carbon, oxygen and hydrogen targets has been measured at the CNAO particle therapy center (Pavia, Italy). The use of thin targets of graphite (C), PMMA (C2O5H8) and polyvinyl-toluene (plastic scintillator, CbHa) allowed to measure fragments production cross sections, exploiting a Time of Flight (ToF) technique. Plastic scintillator detectors have been used to perform the ToF measurements, while LYSO crystals have been used for the deposited energy measurement and to perform particle identification. Cross sections have been measured at 90 and 60 degrees with respect to the beam direction. The measured proton, deuteron and triton differential production cross sections on C, O and H, obtained exploiting the target subtraction strategy, are presented here as a function of the fragment kinetic energy.
- 1 August 2019
- Published by Elsevier in Physica Medica
- Vol. 64, 45-53
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles
- 1 August 2019
- Published by Elsevier in Physica Medica
- Vol. 64, 45-53
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles
- Open Access
- 1 January 2019
- Published by Walter de Gruyter GmbH in Open Physics
- Vol. 17 (1) , 233-240
Ion charge separation with new generation of nuclear emulsion films
In hadron therapy, the accelerated ions, interacting with the body of the patient, cause the fragmentation of both projectile and target nuclei. The fragments interact with the human tissues depositing energy both in the entrance channel and in the volume surrounding the tumor. The knowledge of the fragments features is crucial to determine the energy amount deposited in the human body, and - hence - the damage to the organs and to the tissues around the tumor target. The FOOT (FragmentatiOn Of Target) experiment aims at studying the fragmentation induced by the interaction of a proton beam (150-250 MeV/n) inside the human body. The FOOT detector includes an electronic setup for the identification of Z ≥ 3 fragments integrated with an emulsion spectrometer to measure Z ≤ 3 fragments. Charge identification by nuclear emulsions is based on the development of techniques of controlled fading of the particle tracks inside the nuclear emulsion, that extend the dynamical range of the films developed for the tracking of minimum ionising particles. The controlled fading strongly depends on temperature, relative humidity and treatment duration. In this study the performances in terms of charge separation of proton, helium and carbon particles, obtained on a batch of new emulsion films produced in Japan are reported.
- 1 January 2019
- Published by Walter de Gruyter GmbH in Open Physics
- Vol. 17 (1) , 233-240
Open AccessIon charge separation with new generation of nuclear emulsion films
In hadron therapy, the accelerated ions, interacting with the body of the patient, cause the fragmentation of both projectile and target nuclei. The fragments interact with the human tissues depositing energy both in the entrance channel and in the volume surrounding the tumor. The knowledge of the fragments features is crucial to determine the energy amount deposited in the human body, and - hence - the damage to the organs and to the tissues around the tumor target. The FOOT (FragmentatiOn Of Target) experiment aims at studying the fragmentation induced by the interaction of a proton beam (150-250 MeV/n) inside the human body. The FOOT detector includes an electronic setup for the identification of Z ≥ 3 fragments integrated with an emulsion spectrometer to measure Z ≤ 3 fragments. Charge identification by nuclear emulsions is based on the development of techniques of controlled fading of the particle tracks inside the nuclear emulsion, that extend the dynamical range of the films developed for the tracking of minimum ionising particles. The controlled fading strongly depends on temperature, relative humidity and treatment duration. In this study the performances in terms of charge separation of proton, helium and carbon particles, obtained on a batch of new emulsion films produced in Japan are reported.
- 1 December 2018
- Published by Elsevier in Radiation Measurements
- Vol. 119, 144-149
Characterisation of the MONDO detector response to neutrons by means of a FLUKA Monte Carlo simulation
- 1 December 2018
- Published by Elsevier in Radiation Measurements
- Vol. 119, 144-149
Characterisation of the MONDO detector response to neutrons by means of a FLUKA Monte Carlo simulation
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 2054-2060
Scintillating Fiber Devices for Particle Therapy Applications
Particle therapy (PT) is a radiation therapy technique in which solid tumors are treated with charged ions and exploits the achievable highly localized dose delivery, allowing to spare healthy tissues and organs at risk. The development of a range monitoring technique to be used online, during the treatment, capable to reach millimetric precision is considered one of the important steps toward an optimization of the PT efficacy and of the treatment quality. To this aim, charged secondary particles produced in the nuclear interactions between the beam particles and the patient tissues can be exploited. Besides charged secondaries, neutrons are also produced in nuclear interactions. The secondary neutron component might cause an undesired and not negligible dose deposition far away from the tumor region, enhancing the risk of secondary malignant neoplasms that can develop even years after the treatment. An accurate neutron characterization (flux, energy and emission profile) is, hence, needed for a better evaluation of long-term complications. In this contribution, two tracker detectors, both based on scintillating fibers, are presented. The first one, named dose profiler (DP), is planned to be used as a beam range monitor in PT treatments with heavy ion beams, exploiting the charged secondary fragments production. The DP is currently under development within the Innovative Solutions for In-Beam DosimEtry in Hadrontherapy project. The second one is dedicated to the measurement of the fast and ultrafast neutron component produced in PT treatments, in the framework of the monitor for neutron dose in hadrontherapy project. Results of the first calibration tests performed at the Trento Protontherapy Center and at Centro Nazionale di Adroterapia Oncologica (Italy) are reported, as well as simulation studies.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 2054-2060
Scintillating Fiber Devices for Particle Therapy Applications
Particle therapy (PT) is a radiation therapy technique in which solid tumors are treated with charged ions and exploits the achievable highly localized dose delivery, allowing to spare healthy tissues and organs at risk. The development of a range monitoring technique to be used online, during the treatment, capable to reach millimetric precision is considered one of the important steps toward an optimization of the PT efficacy and of the treatment quality. To this aim, charged secondary particles produced in the nuclear interactions between the beam particles and the patient tissues can be exploited. Besides charged secondaries, neutrons are also produced in nuclear interactions. The secondary neutron component might cause an undesired and not negligible dose deposition far away from the tumor region, enhancing the risk of secondary malignant neoplasms that can develop even years after the treatment. An accurate neutron characterization (flux, energy and emission profile) is, hence, needed for a better evaluation of long-term complications. In this contribution, two tracker detectors, both based on scintillating fibers, are presented. The first one, named dose profiler (DP), is planned to be used as a beam range monitor in PT treatments with heavy ion beams, exploiting the charged secondary fragments production. The DP is currently under development within the Innovative Solutions for In-Beam DosimEtry in Hadrontherapy project. The second one is dedicated to the measurement of the fast and ultrafast neutron component produced in PT treatments, in the framework of the monitor for neutron dose in hadrontherapy project. Results of the first calibration tests performed at the Trento Protontherapy Center and at Centro Nazionale di Adroterapia Oncologica (Italy) are reported, as well as simulation studies.