Daxi Geng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daxi Geng has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Deyuan Zhang
School of Mechanical Engineering and Automation, Beihang University, Beijing, China
10 shared publications Xinggang Jiang
School of Mechanical Engineering and Automation, Beihang University, Beijing, China
10 shared publicationsDeyuan Zhang
9 shared publications- Xinggang Jiang
School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, China
7 shared publications Zhenyu Shao
Aerospace Times FeiHong Technology Company Limited, Beijing, China
6 shared publicationsZhefei Sun
School of Mechanical Engineering and Automation, Beihang University, Beijing, China
5 shared publications
Latest Publications
- Top Cited Papers
- 8 January 2026
- Published by Elsevier in Tribology International
- Vol. 217
Effects of self-excited vibration on tool wear behaviors in cutting of Inconel 718 superalloy
- 8 January 2026
- Published by Elsevier in Tribology International
- Vol. 217
Top Cited PapersEffects of self-excited vibration on tool wear behaviors in cutting of Inconel 718 superalloy
- Open Access
Design and Experimental Verification of a Compact Robot for Large-Curvature Surface Drilling
Automated precision drilling is essential for aircraft skin manufacturing, yet current robotic systems face dual challenges: chatter-induced inaccuracies in hole quality and limited access to confined spaces such as air inlets. To overcome these limitations, this paper develops a compact drilling robot for drilling large-curvature skins of aircraft air inlets. Targeting the precision drilling requirements for complex-curvature aircraft air inlets, we present the robot’s overall design scheme, detailing each module’s composition to ensure precision drilling. In-depth analysis of the robot’s large-curvature adaptability precisely calculates the wheel assembly dimensions. To ensure high-precision drilling bit entry into guide mechanisms, a flexible drilling spindle mechanism is designed, with calculated and verified elastic ranges. An integrated intelligent control system is developed, combining vision recognition, real-time pose adjustment, and automated drilling workflow planning. Finally, traversability and drilling capabilities are validated using a simplified air inlet model. Test results confirm successful traversal on R200 mm curvature skins and automated drilling of Carbon Fiber-Reinforced Polymer (CFRP)/7075 aluminum stacks with a diameter of Φ4–Φ6 mm, achieving dimensional errors of less than 0.05 mm and normal direction errors of less than 0.65°.
Open AccessDesign and Experimental Verification of a Compact Robot for Large-Curvature Surface Drilling
Automated precision drilling is essential for aircraft skin manufacturing, yet current robotic systems face dual challenges: chatter-induced inaccuracies in hole quality and limited access to confined spaces such as air inlets. To overcome these limitations, this paper develops a compact drilling robot for drilling large-curvature skins of aircraft air inlets. Targeting the precision drilling requirements for complex-curvature aircraft air inlets, we present the robot’s overall design scheme, detailing each module’s composition to ensure precision drilling. In-depth analysis of the robot’s large-curvature adaptability precisely calculates the wheel assembly dimensions. To ensure high-precision drilling bit entry into guide mechanisms, a flexible drilling spindle mechanism is designed, with calculated and verified elastic ranges. An integrated intelligent control system is developed, combining vision recognition, real-time pose adjustment, and automated drilling workflow planning. Finally, traversability and drilling capabilities are validated using a simplified air inlet model. Test results confirm successful traversal on R200 mm curvature skins and automated drilling of Carbon Fiber-Reinforced Polymer (CFRP)/7075 aluminum stacks with a diameter of Φ4–Φ6 mm, achieving dimensional errors of less than 0.05 mm and normal direction errors of less than 0.65°.
- 11 December 2025
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 26 (12) , 1179-1196
Elliptical ultrasonic side milling for improved surface integrity and fatigue resistance of thin-walled Ti6Al4V components
Ti6Al4V alloy is critical for thin-walled aerospace components, yet conventional methods for its surface enhancement struggle to balance efficiency and pre
- 11 December 2025
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 26 (12) , 1179-1196
Elliptical ultrasonic side milling for improved surface integrity and fatigue resistance of thin-walled Ti6Al4V components
Ti6Al4V alloy is critical for thin-walled aerospace components, yet conventional methods for its surface enhancement struggle to balance efficiency and pre
- Top Cited Papers
- 21 June 2025
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 26 (8) , 707-722
High-performance milling of Ti-6Al-4V through rotary ultrasonic elliptical milling with anticlockwise elliptical vibration
Ultrasonic elliptical vibration cutting (UEVC) with clockwise elliptical vibration has made notable achievements in precision machining; however, its criti
- 21 June 2025
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 26 (8) , 707-722
Top Cited PapersHigh-performance milling of Ti-6Al-4V through rotary ultrasonic elliptical milling with anticlockwise elliptical vibration
Ultrasonic elliptical vibration cutting (UEVC) with clockwise elliptical vibration has made notable achievements in precision machining; however, its criti
- Open Access
Design of a Longitudinal-Bending Elliptical Vibration Ultrasonic Transducer with a Bent Horn
The thin and straight horn of the ultrasonic transducer is located in the center of the thick transducer, so that the tool tip of the ultrasonic vibration turning tool holder cannot be located on the outermost side of the entire tool holder, which leads to the structural interference between the tool holder and the part during turning. In order to solve this problem, this paper proposes a longitudinal-bending elliptical vibration ultrasonic transducer with a bending horn for ultrasonic vibration-assisted cutting (UVAC). The designed transducer can be used for the partial separation continuous high-speed elliptic ultrasonic vibration cutting (HEUVC) of external surface and internal cavity. The ultrasonic vibration amplitude of the transducer can meet the needs of HEUVC. When using an ultrasonic transducer with a bending horn for HEUVC, compared with conventional cutting (CC), HEUVC can improve the tool life by about 50%.
Open AccessDesign of a Longitudinal-Bending Elliptical Vibration Ultrasonic Transducer with a Bent Horn
The thin and straight horn of the ultrasonic transducer is located in the center of the thick transducer, so that the tool tip of the ultrasonic vibration turning tool holder cannot be located on the outermost side of the entire tool holder, which leads to the structural interference between the tool holder and the part during turning. In order to solve this problem, this paper proposes a longitudinal-bending elliptical vibration ultrasonic transducer with a bending horn for ultrasonic vibration-assisted cutting (UVAC). The designed transducer can be used for the partial separation continuous high-speed elliptic ultrasonic vibration cutting (HEUVC) of external surface and internal cavity. The ultrasonic vibration amplitude of the transducer can meet the needs of HEUVC. When using an ultrasonic transducer with a bending horn for HEUVC, compared with conventional cutting (CC), HEUVC can improve the tool life by about 50%.
- Open Access
- 12 May 2025
- Published by MDPI AG in Preprints.org
Design of Longitudinal-Bending Elliptical Vibration Ultrasonic Transducer with Bending Horn
The thin and straight horn of the ultrasonic transducer is located in the center of the thick transducer, so that the tool tip of the ultrasonic vibration turning tool holder cannot be located on the outermost side of the entire tool holder, which leads to the structural interference between the tool holder and the part during turning. In order to solve this problem, this paper proposes a longitudinal-bending elliptical vibration ultrasonic transducer with bending horn for ultrasonic vibration-assisted cutting (UVAC). A-type transducer can be used for UVAC of external surface, and B-type transducer can be used for UVAC of internal cavity. The maximum peak-peak amplitudes of longitudinal vibration and bending vibration for A-type transducer are 14μm and 16μm, respectively. The maximum peak-peak amplitudes of longitudinal vibration and bending vibration for B-type transducer are 17μm and 21μm, respectively. Such a large amplitude can fully meet the needs of UVAC. When using ultrasonic transducer with bending horn for partial separation continuous high-speed elliptic ultrasonic vibration cutting (HEUVC), compared with conventional cutting (CC), HEUVC can improve the tool life by 65.74% for A-type transducer, HEUVC can improve the tool life by 44.62% for B-type transducer.
- 12 May 2025
- Published by MDPI AG in Preprints.org
Open AccessDesign of Longitudinal-Bending Elliptical Vibration Ultrasonic Transducer with Bending Horn
The thin and straight horn of the ultrasonic transducer is located in the center of the thick transducer, so that the tool tip of the ultrasonic vibration turning tool holder cannot be located on the outermost side of the entire tool holder, which leads to the structural interference between the tool holder and the part during turning. In order to solve this problem, this paper proposes a longitudinal-bending elliptical vibration ultrasonic transducer with bending horn for ultrasonic vibration-assisted cutting (UVAC). A-type transducer can be used for UVAC of external surface, and B-type transducer can be used for UVAC of internal cavity. The maximum peak-peak amplitudes of longitudinal vibration and bending vibration for A-type transducer are 14μm and 16μm, respectively. The maximum peak-peak amplitudes of longitudinal vibration and bending vibration for B-type transducer are 17μm and 21μm, respectively. Such a large amplitude can fully meet the needs of UVAC. When using ultrasonic transducer with bending horn for partial separation continuous high-speed elliptic ultrasonic vibration cutting (HEUVC), compared with conventional cutting (CC), HEUVC can improve the tool life by 65.74% for A-type transducer, HEUVC can improve the tool life by 44.62% for B-type transducer.
- Open Access
- 25 January 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 35, 2584-2601
Feasibility study of partial separation continuous high-speed ultrasonic vibration cutting Inconel 718
- 25 January 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 35, 2584-2601
Open AccessFeasibility study of partial separation continuous high-speed ultrasonic vibration cutting Inconel 718
- Open Access
- 21 April 2024
- Published by Elsevier in Chinese Journal of Aeronautics
- Vol. 37 (10) , 493-507
Influence of transversal vibration on cutting performance and surface integrity during ultrasonic peening drilling of Al-Li alloys
- 21 April 2024
- Published by Elsevier in Chinese Journal of Aeronautics
- Vol. 37 (10) , 493-507
Open AccessInfluence of transversal vibration on cutting performance and surface integrity during ultrasonic peening drilling of Al-Li alloys
- 27 February 2024
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 25 (4) , 275-291
High-efficiency ultrasonic assisted drilling of CFRP/Ti stacks under non-separation type and dry conditions
In this study, to address the low efficiency for conventional ultrasonic-assisted drilling (UAD) of carbon fiber-reinforced plastic and titanium alloy (CFR
- 27 February 2024
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 25 (4) , 275-291
High-efficiency ultrasonic assisted drilling of CFRP/Ti stacks under non-separation type and dry conditions
In this study, to address the low efficiency for conventional ultrasonic-assisted drilling (UAD) of carbon fiber-reinforced plastic and titanium alloy (CFR
- Top Cited Papers
- 27 June 2023
- Published by Elsevier in Ultrasonics
- Vol. 134, 107097
High performance drilling of T800 CFRP composites by combining ultrasonic vibration and optimized drill structure
- 27 June 2023
- Published by Elsevier in Ultrasonics
- Vol. 134, 107097
Top Cited PapersHigh performance drilling of T800 CFRP composites by combining ultrasonic vibration and optimized drill structure