Francois Vasey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Francois Vasey has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Jan Troska
CERN
18 shared publications Csaba Soos
Experimental Physics Department, CERN, Geneva, Switzerland
7 shared publicationsC Soos
CERN
6 shared publicationsChristophe Sigaud
Experimental Physics Department, CERN, CH1211 Geneva, Switzerland
4 shared publications- Christophe Sigaud
CERN, Esplanade des Particules 1, 1211 Geneva 23, Switzerland
4 shared publications - Ioannis Papakonstantinou
University College London
4 shared publications
Latest Publications
- Open Access
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , P08027
Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC
Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , P08027
Open AccessOperation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC
Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.
- Open Access
- 16 March 2022
- Published by The Royal Society in Royal Society Open Science
- Vol. 9 (3) , 211519
The HEV Ventilator: at the interface between particle physics and biomedical engineering
A high-quality, low-cost ventilator, dubbed HEV, has been developed by the particle physics community working together with biomedical engineers and physicians around the world. The HEV design is suitable for use both in and out of hospital intensive care units, provides a variety of modes and is capable of supporting spontaneous breathing and supplying oxygen-enriched air. An external air supply can be combined with the unit for use in situations where compressed air is not readily available. HEV supports remote training and post market surveillance via a Web interface and data logging to complement standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the ventilation performance, especially the quality and accuracy of the pressure curves, reactivity of the trigger, measurement of delivered volume and control of oxygen mixing, delivering a global performance which will be applicable to ventilator needs beyond the COVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with a performance evaluation.
- 16 March 2022
- Published by The Royal Society in Royal Society Open Science
- Vol. 9 (3) , 211519
Open AccessThe HEV Ventilator: at the interface between particle physics and biomedical engineering
A high-quality, low-cost ventilator, dubbed HEV, has been developed by the particle physics community working together with biomedical engineers and physicians around the world. The HEV design is suitable for use both in and out of hospital intensive care units, provides a variety of modes and is capable of supporting spontaneous breathing and supplying oxygen-enriched air. An external air supply can be combined with the unit for use in situations where compressed air is not readily available. HEV supports remote training and post market surveillance via a Web interface and data logging to complement standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the ventilation performance, especially the quality and accuracy of the pressure curves, reactivity of the trigger, measurement of delivered volume and control of oxygen mixing, delivering a global performance which will be applicable to ventilator needs beyond the COVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with a performance evaluation.
- Open Access
- 10 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (4) , 447-457
A Timing, Trigger, and Control System With Picosecond Precision Based on 10 Gbit/s Passive Optical Networks for High-Energy Physics
The Large Hadron Collider (LHC) experiments will have their timing, trigger, and control (TTC) system upgraded as a consequence of the need for higher bandwidth and components which are obsolete. In this article, we present a TTC based on passive optical networks (PONs). TTC-PON is a point-to-multipoint bidirectional TTC system based on the 10 Gbit/s International Telecommunications Union (ITU) XG-PON technology and modern field-programmable gate array (FPGA) devices. Each master can handle up to 64 slaves through a fully passive network, delivering a fixed-phase recovered clock to all the destinations with less than 5-ps jitter. TTC-PON pushes the limits of the PON technology by exploiting cutting-edge custom protocols on top of the commercially available XG-PON optical modules. It can potentially reuse the current optical fiber infrastructure already installed in the experiments and allows for high flexibility in terms of partitioning, which can ease future upgrades of the TTC network. The system features a picosecond-level on-the-fly phase monitoring for each slave's recovered clock by exploiting the bidirectionality of the network. In addition, a full set of link-quality monitoring tools was developed, allowing real-time performance monitoring. An overview of the tailored protocols will be given together with the details on the system implementation, operation, and performance. A discussion on the characterization campaign of more than 1000 optical modules delivered to the first implementation of the TTC-PON system will be drawn.
- 10 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (4) , 447-457
Open AccessA Timing, Trigger, and Control System With Picosecond Precision Based on 10 Gbit/s Passive Optical Networks for High-Energy Physics
The Large Hadron Collider (LHC) experiments will have their timing, trigger, and control (TTC) system upgraded as a consequence of the need for higher bandwidth and components which are obsolete. In this article, we present a TTC based on passive optical networks (PONs). TTC-PON is a point-to-multipoint bidirectional TTC system based on the 10 Gbit/s International Telecommunications Union (ITU) XG-PON technology and modern field-programmable gate array (FPGA) devices. Each master can handle up to 64 slaves through a fully passive network, delivering a fixed-phase recovered clock to all the destinations with less than 5-ps jitter. TTC-PON pushes the limits of the PON technology by exploiting cutting-edge custom protocols on top of the commercially available XG-PON optical modules. It can potentially reuse the current optical fiber infrastructure already installed in the experiments and allows for high flexibility in terms of partitioning, which can ease future upgrades of the TTC network. The system features a picosecond-level on-the-fly phase monitoring for each slave's recovered clock by exploiting the bidirectionality of the network. In addition, a full set of link-quality monitoring tools was developed, allowing real-time performance monitoring. An overview of the tailored protocols will be given together with the details on the system implementation, operation, and performance. A discussion on the characterization campaign of more than 1000 optical modules delivered to the first implementation of the TTC-PON system will be drawn.
- Open Access
- 23 May 2019
- Published by Sissa Medialab Srl
- Vol. 343, 151
Next generation of Radiation Tolerant Single-Mode Optical Links for Accelerator Instrumentation
Long-reach data transmission is an enabling technology for Accelerator Instrumentation at CERN. We present the development of next generation radiation-hard single-mode optical links. This new design aims to support the increasing data volume produced by the beam sensing electronics deployed along the accelerators. We present the design of the new optical data link and its characterization in terms of functional performance and radiation tolerance.
- 23 May 2019
- Published by Sissa Medialab Srl
- Vol. 343, 151
Open AccessNext generation of Radiation Tolerant Single-Mode Optical Links for Accelerator Instrumentation
Long-reach data transmission is an enabling technology for Accelerator Instrumentation at CERN. We present the development of next generation radiation-hard single-mode optical links. This new design aims to support the increasing data volume produced by the beam sensing electronics deployed along the accelerators. We present the design of the new optical data link and its characterization in terms of functional performance and radiation tolerance.
- 4 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (7) , 1663-1670
Radiation Effects on High-Speed InGaAs Photodiodes
Photodiodes are important components in optical data links, and their performance degradation under irradiation has to be understood in order to guarantee the long-term functionality of the data links in radiation environments of high-energy physics experiments. InGaAs on InP photodiodes are attractive candidates for these applications thanks to their relatively modest radiation-induced responsivity loss when operated at detect-all850. In this paper we present the results that confirm earlier observed additional sensitivity penalties in InGaAs-based receivers. This behavior is further investigated by carrying out several proton tests where InGaAs photodiodes are irradiated together with alternative photodiode types. The critical parameters – responsivity, dark current, and capacitance – are measured up to fluences exceeding detect-all1e16. Radiation-induced dark current is shown to be orders of magnitude higher in InGaAs photodiodes than in GaAs and InGaAs on GaAs photodiodes. However, instead of the dark current increase, the additional losses with InGaAs photodiodes are shown to arise from strongly increased capacitance, which is a dominant feature only in InGaAs photodiodes. This is confirmed with simulations where the measured capacitance characteristics are used in the device model. Our results show that without precautions in the receiver design radiation-induced capacitance can limit the use of InGaAs photodiodes in harsh radiation environments.
- 4 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (7) , 1663-1670
Radiation Effects on High-Speed InGaAs Photodiodes
Photodiodes are important components in optical data links, and their performance degradation under irradiation has to be understood in order to guarantee the long-term functionality of the data links in radiation environments of high-energy physics experiments. InGaAs on InP photodiodes are attractive candidates for these applications thanks to their relatively modest radiation-induced responsivity loss when operated at detect-all850. In this paper we present the results that confirm earlier observed additional sensitivity penalties in InGaAs-based receivers. This behavior is further investigated by carrying out several proton tests where InGaAs photodiodes are irradiated together with alternative photodiode types. The critical parameters – responsivity, dark current, and capacitance – are measured up to fluences exceeding detect-all1e16. Radiation-induced dark current is shown to be orders of magnitude higher in InGaAs photodiodes than in GaAs and InGaAs on GaAs photodiodes. However, instead of the dark current increase, the additional losses with InGaAs photodiodes are shown to arise from strongly increased capacitance, which is a dominant feature only in InGaAs photodiodes. This is confirmed with simulations where the measured capacitance characteristics are used in the device model. Our results show that without precautions in the receiver design radiation-induced capacitance can limit the use of InGaAs photodiodes in harsh radiation environments.
- Open Access
- 6 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 1624-1631
Investigation of the Influence of Temperature and Annealing on the Radiation Hardness of Silicon Mach–Zehnder Modulators
Optical links are vital components in the data transmission systems of high energy physics (HEP) experiments at CERN. With the ever higher beam fluxes achieved by the Large Hadron Collider, the optical components have to withstand higher radiation levels and handle ever-increasing data volumes. To face these challenges, the use of silicon photonics (SiPh) Mach–Zehnder modulators (MZMs) in the next generation of optical transceivers for HEP experiments is currently being investigated. In this paper, the dependence of the radiation hardness of custom-designed SiPh MZMs on temperature is reported, including the observed improvement in radiation tolerance at low operating temperatures that are closer to the typical temperatures found in HEP experiments. Furthermore, postirradiation annealing measurements of the devices were performed. An effective annealing method has been found by applying a forward current to the MZMs, leading to an almost immediate and full recovery of the device after irradiation up to 3 MGy. This enhanced device recovery method could effectively increase the radiation hardness tremendously in applications with low dose rates and periodic shutdown times.
- 6 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 1624-1631
Open AccessInvestigation of the Influence of Temperature and Annealing on the Radiation Hardness of Silicon Mach–Zehnder Modulators
Optical links are vital components in the data transmission systems of high energy physics (HEP) experiments at CERN. With the ever higher beam fluxes achieved by the Large Hadron Collider, the optical components have to withstand higher radiation levels and handle ever-increasing data volumes. To face these challenges, the use of silicon photonics (SiPh) Mach–Zehnder modulators (MZMs) in the next generation of optical transceivers for HEP experiments is currently being investigated. In this paper, the dependence of the radiation hardness of custom-designed SiPh MZMs on temperature is reported, including the observed improvement in radiation tolerance at low operating temperatures that are closer to the typical temperatures found in HEP experiments. Furthermore, postirradiation annealing measurements of the devices were performed. An effective annealing method has been found by applying a forward current to the MZMs, leading to an almost immediate and full recovery of the device after irradiation up to 3 MGy. This enhanced device recovery method could effectively increase the radiation hardness tremendously in applications with low dose rates and periodic shutdown times.
- Open Access
- 5 March 2018
- Published by Sissa Medialab Srl
- Vol. 313, 124
Demonstrating TTC-PON Robustness and Flexibility
- 5 March 2018
- Published by Sissa Medialab Srl
- Vol. 313, 124
Open AccessDemonstrating TTC-PON Robustness and Flexibility
- Open Access
- 5 March 2018
- Published by Sissa Medialab Srl
- Vol. 313, 053
CERN-IPMC Solution for AdvancedTCA Blades
The AdvancedTCA standard has been selected as one of the hardware platforms for the upgrades of the back-end electronics of the CMS and ATLAS experiments of the Large Hadron Collider. In this context, the CERN EP-ESE group has designed and produced an IPMC mezzanine card for the management of AdvancedTCA blades. This paper presents the CERN-IPMC hardware and the software environment to be used for its customization and describes a test pad that can also be used as a development kit.
- 5 March 2018
- Published by Sissa Medialab Srl
- Vol. 313, 053
Open AccessCERN-IPMC Solution for AdvancedTCA Blades
The AdvancedTCA standard has been selected as one of the hardware platforms for the upgrades of the back-end electronics of the CMS and ATLAS experiments of the Large Hadron Collider. In this context, the CERN EP-ESE group has designed and produced an IPMC mezzanine card for the management of AdvancedTCA blades. This paper presents the CERN-IPMC hardware and the software environment to be used for its customization and describes a test pad that can also be used as a development kit.
- 1 March 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (3) , E03002
ERRATUM: A system-level model for high-speed, radiation-hard optical links in HEP experiments based on silicon Mach-Zehnder modulators
Please see the PDF file for details.
- 1 March 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (3) , E03002
ERRATUM: A system-level model for high-speed, radiation-hard optical links in HEP experiments based on silicon Mach-Zehnder modulators
Please see the PDF file for details.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Comparison of the radiation hardness of silicon Mach-Zehnder modulators for different DC bias voltages
Radiation hard optical links are the backbone of read-out systems in high-energy physics experiments at CERN. The optical components have to withstand large doses of radiation and provide high data rates. Silicon photonics is currently being considered a promising technology to replace electrical and optical links in future experiments. It has already been demonstrated that integrated silicon Mach-Zehnder modulators can withstand a high neutron fluence and large total ionizing doses. Before read-out systems based on these components can be taken into consideration, it has to be determined how biasing affects their radiation hardness. For this reason we prepared bonded and fiber-pigtailed prototypes and irradiated them with x-rays. We found that under reverse-bias the radiation hardness of the tested components is reduced in comparison to un-biased samples. However, we were able to show that one device type can withstand the radiation without phase shift degradation up to 1 MGy despite the accelerated degradation due to biasing.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Comparison of the radiation hardness of silicon Mach-Zehnder modulators for different DC bias voltages
Radiation hard optical links are the backbone of read-out systems in high-energy physics experiments at CERN. The optical components have to withstand large doses of radiation and provide high data rates. Silicon photonics is currently being considered a promising technology to replace electrical and optical links in future experiments. It has already been demonstrated that integrated silicon Mach-Zehnder modulators can withstand a high neutron fluence and large total ionizing doses. Before read-out systems based on these components can be taken into consideration, it has to be determined how biasing affects their radiation hardness. For this reason we prepared bonded and fiber-pigtailed prototypes and irradiated them with x-rays. We found that under reverse-bias the radiation hardness of the tested components is reduced in comparison to un-biased samples. However, we were able to show that one device type can withstand the radiation without phase shift degradation up to 1 MGy despite the accelerated degradation due to biasing.