Stuart R. Miller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Stuart R. Miller has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- VivekV. Nagarkar
Radiation Monitoring Devices, Inc., Watertown, MA, USA
10 shared publications Charles Brecher
Radiation Monitoring Devices (RMD), Watertown, MA 02472, USA
7 shared publications- Megan Wart
Radiation Monitoring Devices, Inc., Watertown, MA 02472 USA
6 shared publications Vivek V. Nagarkar
Radiation Monitoring Devices, Inc. (United States)
6 shared publications- Matthew S. J. Marshall
Radiation Monitoring Devices, Inc., Watertown, MA, USA
5 shared publications - Pijush Bhattacharya
Radiation Monitoring Devices (RMD), Watertown, MA 02472, USA
4 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by Springer Nature
- p. 276-289
Characterization of Dual-Mode Scintillators for Fast Neutron and X-ray Radiography
X-rays and neutrons serve as sources for various radiographic applications, and scintillators for use with each are well-established. While high-energy X-ray radiography is useful for applications involving high-Z materials, this technique is limited for probing objects with low-density composition. Alternatively, fast neutron radiography can be used for detecting low-Z compositions without significant attenuation by dense materials. By combining fast neutrons and X-rays in a single radiographic application, the complementary information provided by each source can be used to produce images with more information about a subject. Currently, there are no commercially available detectors capable of high-resolution imaging with both fast neutrons and X-rays. Under sponsorship through the DOE/NNSA’s Office of Defense Nuclear Nonproliferation, RMD is developing a high-resolution radiography detector for both high-energy X-ray and fast neutron imaging. The envisioned detector maximizes detection efficiency for fast neutrons and high-energy X-rays, while also producing high-contrast radiographs with sub-mm spatial resolution. Multiple scintillator formats for use in a dual-mode detector have been developed including 1) Embedded ZnS converters, 2) Layered CsI converters, 3) Tin-loaded Organic Glass Scintillators, and 4) Pixelated Organic Glass Scintillators. These scintillators have produced X-ray radiographs with spatial resolutions below 100 µm and fast neutron radiographs with spatial resolutions as low as 550 µm. Here we report on imaging data collected with these dual-mode scintillators using separate fast neutron and X-ray sources.
- 1 June 2026
- Published by Springer Nature
- p. 276-289
Open AccessCharacterization of Dual-Mode Scintillators for Fast Neutron and X-ray Radiography
X-rays and neutrons serve as sources for various radiographic applications, and scintillators for use with each are well-established. While high-energy X-ray radiography is useful for applications involving high-Z materials, this technique is limited for probing objects with low-density composition. Alternatively, fast neutron radiography can be used for detecting low-Z compositions without significant attenuation by dense materials. By combining fast neutrons and X-rays in a single radiographic application, the complementary information provided by each source can be used to produce images with more information about a subject. Currently, there are no commercially available detectors capable of high-resolution imaging with both fast neutrons and X-rays. Under sponsorship through the DOE/NNSA’s Office of Defense Nuclear Nonproliferation, RMD is developing a high-resolution radiography detector for both high-energy X-ray and fast neutron imaging. The envisioned detector maximizes detection efficiency for fast neutrons and high-energy X-rays, while also producing high-contrast radiographs with sub-mm spatial resolution. Multiple scintillator formats for use in a dual-mode detector have been developed including 1) Embedded ZnS converters, 2) Layered CsI converters, 3) Tin-loaded Organic Glass Scintillators, and 4) Pixelated Organic Glass Scintillators. These scintillators have produced X-ray radiographs with spatial resolutions below 100 µm and fast neutron radiographs with spatial resolutions as low as 550 µm. Here we report on imaging data collected with these dual-mode scintillators using separate fast neutron and X-ray sources.
- Open Access
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Gallium nitride (GaN) scintillation response to fast neutrons and flash gamma rays and associated broadband photoluminescence
Gallium nitride (GaN), a wide-bandgap semiconductor (3.45 eV), has emerged as a promising material for radiation detection due to its exceptional radiation tolerance, high thermal stability, and ultrafast scintillation response. This study investigates the energy-dependent scintillation response of bulk and thin GaN crystals to fast neutrons and flash gamma rays. Experiments were conducted at the Los Alamos Neutron Science Center using neutron time-of-flight techniques and a fast-gated intensified CCD camera. GaN crystals were exposed to neutron energies ranging from 0.1 to 400 MeV, including the 14.1 MeV relevant to deuterium–tritium fusion. Results indicate a pronounced gamma-induced scintillation signal with prompt full width-at-half-maximum values of 4.27 ns for thin GaN and 3.60 ns for bulk GaN. Rise times were modeled at 90 ps for thin GaN and 662 ps for bulk GaN, confirming rapid response characteristics. Neutron energy-dependent scintillation was observed, and efficiency per millimeter of material was quantified. Broadband photoluminescence observation revealed emission peaks, which are associated with defect states within the crystal structure. Unlike conventional scintillator materials, GaN offers the unique advantage of integration into semiconductor-based circuits, making it highly suitable for radiation-hard diagnostics in fusion power, nuclear reactors, aerospace, and biomedical applications. These findings demonstrate the viability of GaN as a next-generation integrated scintillation material, paving the way for multi-modal, multi-mode-readout diagnostic platforms in high-radiation environments.
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Open AccessGallium nitride (GaN) scintillation response to fast neutrons and flash gamma rays and associated broadband photoluminescence
Gallium nitride (GaN), a wide-bandgap semiconductor (3.45 eV), has emerged as a promising material for radiation detection due to its exceptional radiation tolerance, high thermal stability, and ultrafast scintillation response. This study investigates the energy-dependent scintillation response of bulk and thin GaN crystals to fast neutrons and flash gamma rays. Experiments were conducted at the Los Alamos Neutron Science Center using neutron time-of-flight techniques and a fast-gated intensified CCD camera. GaN crystals were exposed to neutron energies ranging from 0.1 to 400 MeV, including the 14.1 MeV relevant to deuterium–tritium fusion. Results indicate a pronounced gamma-induced scintillation signal with prompt full width-at-half-maximum values of 4.27 ns for thin GaN and 3.60 ns for bulk GaN. Rise times were modeled at 90 ps for thin GaN and 662 ps for bulk GaN, confirming rapid response characteristics. Neutron energy-dependent scintillation was observed, and efficiency per millimeter of material was quantified. Broadband photoluminescence observation revealed emission peaks, which are associated with defect states within the crystal structure. Unlike conventional scintillator materials, GaN offers the unique advantage of integration into semiconductor-based circuits, making it highly suitable for radiation-hard diagnostics in fusion power, nuclear reactors, aerospace, and biomedical applications. These findings demonstrate the viability of GaN as a next-generation integrated scintillation material, paving the way for multi-modal, multi-mode-readout diagnostic platforms in high-radiation environments.
- 24 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (10) , 2309-2314
Micro-Columnar CsBr:Eu Storage Phosphor for High-Efficiency High Energy Photon Radiography Panels
Eu-doped CsBr films (CsBr:Eu) exhibit excellent sensitivity for X-rays and are superior storage phosphors for high energy (MeV) photon radiography applications when coupled with thick copper or tungsten substrates. We report on the growth of micro-columnar CsBr:Eu films on copper substrates for megavolt (MV) X-ray imaging application. Our films exhibit dense uniformly distributed micro-columns with an average diameter of ~ 10 μm and a sharp, needle-like top. The advantage of this micro-columnar structured film is that the light can be channeled through the narrow columns to improve both light transmission and spatial resolution. We also determined the optimal Eu concentration in CsBr for the best storage phosphor performance. Growth of uniformly thick, micro-columnar structured films up to 2 mm was achieved on 2"×2" metallic substrates, which were then characterized by optically-stimulated luminescence coupled with X-ray excitation. Furthermore, 5 mm thick film growth demonstrates the potential to scale up to even thicker films.
- 24 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (10) , 2309-2314
Micro-Columnar CsBr:Eu Storage Phosphor for High-Efficiency High Energy Photon Radiography Panels
Eu-doped CsBr films (CsBr:Eu) exhibit excellent sensitivity for X-rays and are superior storage phosphors for high energy (MeV) photon radiography applications when coupled with thick copper or tungsten substrates. We report on the growth of micro-columnar CsBr:Eu films on copper substrates for megavolt (MV) X-ray imaging application. Our films exhibit dense uniformly distributed micro-columns with an average diameter of ~ 10 μm and a sharp, needle-like top. The advantage of this micro-columnar structured film is that the light can be channeled through the narrow columns to improve both light transmission and spatial resolution. We also determined the optimal Eu concentration in CsBr for the best storage phosphor performance. Growth of uniformly thick, micro-columnar structured films up to 2 mm was achieved on 2"×2" metallic substrates, which were then characterized by optically-stimulated luminescence coupled with X-ray excitation. Furthermore, 5 mm thick film growth demonstrates the potential to scale up to even thicker films.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Gallium oxide (Ga2O3) energy dependent scintillation response to fast neutrons and flash gamma-rays
Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga2O3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. A pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ∼4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga2O3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Gallium oxide (Ga2O3) energy dependent scintillation response to fast neutrons and flash gamma-rays
Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga2O3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. A pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ∼4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga2O3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.
- 2 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (8) , 1929-1933
High-Resolution Thermal Neutron Imaging With ¹⁰Boron/CsI:Tl Scintillator Screen
High resolution neutron imaging is difficult, due to the low-light output of neutron scintillators, and the spread of light within common neutron-sensitive scintillators as well as the spread of intermediate particles occurring during the detection process. To address this issue, we have developed a high-resolution scintillator for neutron imaging by combining enriched 10B with the well-known CsI:Tl scintillator films. CsI:Tl has excellent properties for X-ray imaging applications, due to a high light yield of 60,000 photons/MeV, and high spatial resolution, which derives from its microcolumnar structure, which channels scintillation light to the photodetector. To enable CsI:Tl to detect neutrons, 10B (96% enriched) was deposited by electron-beam directly onto the CsI:Tl film, making a layered scintillator structure in which the alphas produced by the neutron interaction with 10B are detected in the CsI:Tl. The 10B layer was approximately 3 μm thick, while the thickness of the CsI:Tl film was 11 μm. These novel layered scintillators were integrated into the high-resolution neutron imaging detector (‘PSI Neutron Microscope’) at the POLDI beamline at the Paul Scherer Institute (PSI). With our 10B/CsI:Tl scintillator we were able to achieve a spatial resolution down to 9 μm. To demonstrate the effectiveness of the layered scintillator, we present results obtained by thermal neutron imaging as well as high-resolution neutron computed tomography. Finally, we believe there is considerable scope for future optimization of the performance of this system.
- 2 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (8) , 1929-1933
High-Resolution Thermal Neutron Imaging With ¹⁰Boron/CsI:Tl Scintillator Screen
High resolution neutron imaging is difficult, due to the low-light output of neutron scintillators, and the spread of light within common neutron-sensitive scintillators as well as the spread of intermediate particles occurring during the detection process. To address this issue, we have developed a high-resolution scintillator for neutron imaging by combining enriched 10B with the well-known CsI:Tl scintillator films. CsI:Tl has excellent properties for X-ray imaging applications, due to a high light yield of 60,000 photons/MeV, and high spatial resolution, which derives from its microcolumnar structure, which channels scintillation light to the photodetector. To enable CsI:Tl to detect neutrons, 10B (96% enriched) was deposited by electron-beam directly onto the CsI:Tl film, making a layered scintillator structure in which the alphas produced by the neutron interaction with 10B are detected in the CsI:Tl. The 10B layer was approximately 3 μm thick, while the thickness of the CsI:Tl film was 11 μm. These novel layered scintillators were integrated into the high-resolution neutron imaging detector (‘PSI Neutron Microscope’) at the POLDI beamline at the Paul Scherer Institute (PSI). With our 10B/CsI:Tl scintillator we were able to achieve a spatial resolution down to 9 μm. To demonstrate the effectiveness of the layered scintillator, we present results obtained by thermal neutron imaging as well as high-resolution neutron computed tomography. Finally, we believe there is considerable scope for future optimization of the performance of this system.
- 26 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (6) , 1032-1034
Tl₂ZrCl₆ and Tl₂HfCl₆ Intrinsic Scintillators for Gamma Rays and Fast Neutron Detection
Thallium zirconium chloride (Tl2ZrCl6) and its hafnium analog (Tl2HfCl6) are intrinsic scintillators that have been recently reported, primarily for gamma ray detection and spectroscopy. These crystals are especially useful for dual-mode detection, gammas exploiting the high effective Z of the materials and fast neutrons using the (n,p) and (n,α) reactions with chlorine. The Zeff (70.7) and high photoelectric conversion efficiency of the zirconium variant without any activator makes it particularly attractive in this regard. We report here on the growth of undoped Tl2ZrCl6 and Tl2HfCl6 crystals using vertical Bridgman technique. The X-ray emission spectrum shows a broad band in the range of 400-600 nm with a peak around 470 nm for both crystals. The light yields of these crystals were measured under irradiation by a 137Cs gamma source (662 keV) and compared with that from commercial Tl-doped NaI crystal. Normalized for the quantum efficiency of the PMT at the relevant emission wavelengths, the respective light yields of Tl2ZrCl6 and Tl2HfCl6 are estimated to be 40,000 and 18,000 photons/MeV with corresponding energy resolution of 5% and 9%. We have for the first time demonstrated the neutron detection capability of these materials showing excellent pulse shape discrimination (PSD) with figure of merit on the order of 2.4. PSD measurement of Tl2ZrCl6 using 241AmBe source demonstrate well separated gamma, recoiled proton, and alpha particle bands.
- 26 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (6) , 1032-1034
Tl₂ZrCl₆ and Tl₂HfCl₆ Intrinsic Scintillators for Gamma Rays and Fast Neutron Detection
Thallium zirconium chloride (Tl2ZrCl6) and its hafnium analog (Tl2HfCl6) are intrinsic scintillators that have been recently reported, primarily for gamma ray detection and spectroscopy. These crystals are especially useful for dual-mode detection, gammas exploiting the high effective Z of the materials and fast neutrons using the (n,p) and (n,α) reactions with chlorine. The Zeff (70.7) and high photoelectric conversion efficiency of the zirconium variant without any activator makes it particularly attractive in this regard. We report here on the growth of undoped Tl2ZrCl6 and Tl2HfCl6 crystals using vertical Bridgman technique. The X-ray emission spectrum shows a broad band in the range of 400-600 nm with a peak around 470 nm for both crystals. The light yields of these crystals were measured under irradiation by a 137Cs gamma source (662 keV) and compared with that from commercial Tl-doped NaI crystal. Normalized for the quantum efficiency of the PMT at the relevant emission wavelengths, the respective light yields of Tl2ZrCl6 and Tl2HfCl6 are estimated to be 40,000 and 18,000 photons/MeV with corresponding energy resolution of 5% and 9%. We have for the first time demonstrated the neutron detection capability of these materials showing excellent pulse shape discrimination (PSD) with figure of merit on the order of 2.4. PSD measurement of Tl2ZrCl6 using 241AmBe source demonstrate well separated gamma, recoiled proton, and alpha particle bands.
- 2 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (6) , 969-973
Advances in High-Resolution Ultrafast LuI3:Ce Scintillators for Fast Timing Applications
Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV), and used in high frame rate applications. Here, we describe advances in the development of thin film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in single crystalline form, these scintillators are bright, producing 115,000 photons/MeV [1]. However, to achieve high spatial resolution, these scintillators are grown in thin film form with a microcolumnar structure, controllable to column diameters of <1 to 30 μm. Thus, a much thicker scintillator layer (10 μm to 3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 μm or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Additionally, we report on timing measurements obtained using a PMT and oscilloscope at RMD Inc. Using the TR-XEOL we determined the decay constants of LuI3 as a function of Ce-doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications where ultrahigh frame rates are important using synchrotron X-rays. This paper will discuss fabrication, characterization, and potential applications for this novel scintillator.
- 2 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (6) , 969-973
Advances in High-Resolution Ultrafast LuI3:Ce Scintillators for Fast Timing Applications
Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV), and used in high frame rate applications. Here, we describe advances in the development of thin film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in single crystalline form, these scintillators are bright, producing 115,000 photons/MeV [1]. However, to achieve high spatial resolution, these scintillators are grown in thin film form with a microcolumnar structure, controllable to column diameters of <1 to 30 μm. Thus, a much thicker scintillator layer (10 μm to 3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 μm or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Additionally, we report on timing measurements obtained using a PMT and oscilloscope at RMD Inc. Using the TR-XEOL we determined the decay constants of LuI3 as a function of Ce-doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications where ultrahigh frame rates are important using synchrotron X-rays. This paper will discuss fabrication, characterization, and potential applications for this novel scintillator.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 11312, 38
Pixelated columnar CsI:Tl scintillator for high resolution radiography and cone-beam CT
Microcolumnar CsI:Tl scintillator screens have been the gold standard in X-ray imaging for many years due to their high density, high atomic number, and scintillation efficiency. The structured screens provide an improvement in performance by channeling the light to the detector, improving detection efficiency and spatial resolution. We have taken this concept a step further by laser-machining the CsI:Tl scintillator to provide pixels that match the detector pixels. This allows for still thicker CsI:Tl layers up to 700 μm pixelated with pitch of 100 μm to match CMOS flat panel pixels, thus improving X-ray absorption and resolution. We are investigating the applications of CMOS detectors with pixelated scintillators for imaging of bone microarchitecture on diagnostic Cone Beam CT (CBCT) systems to provide improved quantitative metrics for diagnosis of osteoporosis and osteoarthritis. The scintillator design includes reflective coatings applied to the laser-cut grooves to improve optical isolation between pixels. Such coatings are created by atomic layer deposition (ALD), a unique approach, which permits formation of reflectors over inter-pixel grooves with aspect ratios as high as 140:1. Here we present initial results quantifying performance gains in CMOS detector resolution and their impact on the quality of bone microstructure segmentation. We demonstrate 77% gain in spatial resolution at 2 lp/mm and extension of the limiting resolution from 3 lp/mm to 4.5 lp/mm for the CMOS detector with a pixelated screen compared to a commercial sensor. In a bench-top CBCT study emulating diagnostic systems for orthopedic applications (extremity CBCT), we achieved >0.75 correlations in metrics of trabecular microarchitecture between pixelated CsI:Tl based CBCT and gold-standard micro-CT. The pixelated scintillator is expected to have significant impact for many other applications including mammography and digital radiography, where resolution and dose efficiency (DQE) of the detector are of critical importance.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 11312, 38
Pixelated columnar CsI:Tl scintillator for high resolution radiography and cone-beam CT
Microcolumnar CsI:Tl scintillator screens have been the gold standard in X-ray imaging for many years due to their high density, high atomic number, and scintillation efficiency. The structured screens provide an improvement in performance by channeling the light to the detector, improving detection efficiency and spatial resolution. We have taken this concept a step further by laser-machining the CsI:Tl scintillator to provide pixels that match the detector pixels. This allows for still thicker CsI:Tl layers up to 700 μm pixelated with pitch of 100 μm to match CMOS flat panel pixels, thus improving X-ray absorption and resolution. We are investigating the applications of CMOS detectors with pixelated scintillators for imaging of bone microarchitecture on diagnostic Cone Beam CT (CBCT) systems to provide improved quantitative metrics for diagnosis of osteoporosis and osteoarthritis. The scintillator design includes reflective coatings applied to the laser-cut grooves to improve optical isolation between pixels. Such coatings are created by atomic layer deposition (ALD), a unique approach, which permits formation of reflectors over inter-pixel grooves with aspect ratios as high as 140:1. Here we present initial results quantifying performance gains in CMOS detector resolution and their impact on the quality of bone microstructure segmentation. We demonstrate 77% gain in spatial resolution at 2 lp/mm and extension of the limiting resolution from 3 lp/mm to 4.5 lp/mm for the CMOS detector with a pixelated screen compared to a commercial sensor. In a bench-top CBCT study emulating diagnostic systems for orthopedic applications (extremity CBCT), we achieved >0.75 correlations in metrics of trabecular microarchitecture between pixelated CsI:Tl based CBCT and gold-standard micro-CT. The pixelated scintillator is expected to have significant impact for many other applications including mammography and digital radiography, where resolution and dose efficiency (DQE) of the detector are of critical importance.
- Open Access
- 5 January 2020
- Published by Materials Research Forum, LLC in Materials Research Proceedings
- Vol. 15
High-resolution Detector for Neutron Diffraction and Quantification of Subsurface Residual Stress
- 5 January 2020
- Published by Materials Research Forum, LLC in Materials Research Proceedings
- Vol. 15
Open AccessHigh-resolution Detector for Neutron Diffraction and Quantification of Subsurface Residual Stress