Katharine Virginia Greco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Katharine Virginia Greco has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Fikile Richard Brushett
Massachusetts Institute of Technology
10 shared publications - Antoni Forner-Cuenca
Eindhoven University of Technology
7 shared publications Fikile R. Brushett
Massachusetts Institute of Technology
5 shared publicationsJeffrey A Kowalski
Joint Center for Energy Storage Research
3 shared publications- Maxime van der Heijden
Eindhoven University of Technology
3 shared publications Pierre Boillat
Electrochemistry Laboratory, Paul Scherrer Institut
3 shared publications
Latest Publications
- Open Access
- 5 September 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-16
Quantifying concentration distributions in redox flow batteries with neutron radiography
The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.
- 5 September 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-16
Open AccessQuantifying concentration distributions in redox flow batteries with neutron radiography
The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.
- 7 July 2022
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2022-01 (48) , 2014
Neutron Radiography As a Powerful Method to Visualize Reactive Flows in Redox Flow Batteries
Spatial and temporal gradients in reactant concentration, influenced by local microstructure and surface properties, govern the performance and durability of various advanced electrochemical systems. The cell and stack performance is typically assessed using traditional electrochemical diagnostics (e.g. polarization curves, electrochemical impedance spectroscopy) and the influence of materials is macroscopically evaluated based on empirical comparison of novel materials with the current state-of-the-art. While this is a valid approach to identify promising candidates, valuable information is lost due to the difficulty of identifying performance-limiting factors. Operando imaging of electrochemical systems, in tandem with complementary electrochemical diagnostics, has been instrumental in the development of advanced polymer electrolyte fuel cells1,2 and, more recently, lithium-ion batteries3,4. Over the past few years, several groups have developed novel imaging and spectroscopic techniques for operando characterization of redox flow batteries, which is the focus of this work. Wong et al. employed fluorescence microscopy and particle velocimetry to image concentration and velocity distributions near the electrode-flow field interface5. Tanaka et al. visualized flow distribution in redox flow batteries with infrared thermography6. Zhao et al. employed in-situ nuclear magnetic resonance to track reaction mechanisms occurring within the electrolyte7. Finally, several groups recently employed X-ray tomographic microscopy to visualize gas pockets within the liquid electrolyte imbibed porous electrode8–10. While these methods have provided important insights, an approach that enables quantitative mapping of species concentrations, in a non-invasive fashion and within an operating cell, has remained elusive. In this presentation, I will discuss our recent efforts to develop neutron radiography as an operando characterization method for non-aqueous redox flow batteries. We leverage the high attenuation of organic materials (i.e., high hydrogen content) in solution and, combined with isotopic labelling, we perform subtractive neutron imaging to quantify the concentration of active species and supporting electrolytes. To demonstrate the potential of this diagnostic tool, we characterize active species concentration distribution within a redox flow cell in a single electrolyte configuration with a non-aqueous electrolyte containing a TEMPO/TEMPO+ redox couple and study the influence of electrode microstructure, membrane type (e.g. porous or dense), and flow field design. To resolve the concentration profiles across the different layers, we employ the in-plane imaging configuration11 and correlate these concentration profiles to cell performance via polarization measurements under different operating conditions. In the final part of the talk, I will discuss our latest experimental campaign in which we investigated the use of energy-selective neutron radiography to deconvolute concentrations of active species and supporting electrodes during operation. References 1 P. Boillat, E. H. Lehmann, P. Trtik and M. Cochet, Curr. Opin. Electrochem., , DOI:https://doi.org/10.1016/j.coelec.2017.07.012. 2 J. Eller, T. Rosén, F. Marone, M. Stampanoni, A. Wokaun and F. N. Büchi, J. Electrochem. Soc., 2011, 158, B963. 3 B. Michalak, H. Sommer, D. Mannes, A. Kaestner, T. Brezesinski and J. Janek, Sci. Rep., 2015, 5, 15627. 4 D. P. Finegan, M. Scheel, J. B. Robinson, B. Tjaden, I. Hunt, T. J. Mason, J. Millichamp, M. Di Michiel, G. J. Offer, G. Hinds, D. J. L. Brett and P. R. Shearing, Nat. Commun., 2015, 6, 6924. 5 A. A. Wong, M. J. Aziz and S. Rubinstein, ECS Trans. , 2017, 77, 153–161. 6 H. Tanaka, Y. Miyafuji, J. Fukushima, T. Tayama, T. Sugita, M. Takezawa and T. Muta, J. Energy Storage, 2018, 19, 67–72. 7 E. W. Zhao, T. Liu, E. Jónsson, J. Lee, I. Temprano, R. B. Jethwa, A. Wang, H. Smith, J. Carretero-González, Q. Song and C. P. Grey, Nature, 2020, 579, 224–228. 8 R. Jervis, L. D. Brown, T. P. Neville, J. Millichamp, D. P. Finegan, T. M. M. Heenan, D. J. L. Brett and P. R. Shearing, J. Phys. D. Appl. Phys., , DOI:10.1088/0022-3727/49/43/434002. 9 F. Tariq, J. Rubio-Garcia, V. Yufit, A. Bertei, B. K. Chakrabarti, A. Kucernak and N. Brandon, Sustain. Energy Fuels, 2018, 2, 2068–2080. 10 K. Köble, L. Eifert, N. Bevilacqua, K. F. Fahy, A. Bazylak and R. Zeis, J. Power Sources, , DOI:10.1016/j.jpowsour.2021.229660. 11 P. Boillat, D. Kramer, B. C. Seyfang, G. Frei, E. Lehmann, G. G. Scherer, A. Wokaun, Y. Ichikawa, Y. Tasaki and K. Shinohara, Electrochem. commun., 2008, 10, 546–550.
- 7 July 2022
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2022-01 (48) , 2014
Neutron Radiography As a Powerful Method to Visualize Reactive Flows in Redox Flow Batteries
Spatial and temporal gradients in reactant concentration, influenced by local microstructure and surface properties, govern the performance and durability of various advanced electrochemical systems. The cell and stack performance is typically assessed using traditional electrochemical diagnostics (e.g. polarization curves, electrochemical impedance spectroscopy) and the influence of materials is macroscopically evaluated based on empirical comparison of novel materials with the current state-of-the-art. While this is a valid approach to identify promising candidates, valuable information is lost due to the difficulty of identifying performance-limiting factors. Operando imaging of electrochemical systems, in tandem with complementary electrochemical diagnostics, has been instrumental in the development of advanced polymer electrolyte fuel cells1,2 and, more recently, lithium-ion batteries3,4. Over the past few years, several groups have developed novel imaging and spectroscopic techniques for operando characterization of redox flow batteries, which is the focus of this work. Wong et al. employed fluorescence microscopy and particle velocimetry to image concentration and velocity distributions near the electrode-flow field interface5. Tanaka et al. visualized flow distribution in redox flow batteries with infrared thermography6. Zhao et al. employed in-situ nuclear magnetic resonance to track reaction mechanisms occurring within the electrolyte7. Finally, several groups recently employed X-ray tomographic microscopy to visualize gas pockets within the liquid electrolyte imbibed porous electrode8–10. While these methods have provided important insights, an approach that enables quantitative mapping of species concentrations, in a non-invasive fashion and within an operating cell, has remained elusive. In this presentation, I will discuss our recent efforts to develop neutron radiography as an operando characterization method for non-aqueous redox flow batteries. We leverage the high attenuation of organic materials (i.e., high hydrogen content) in solution and, combined with isotopic labelling, we perform subtractive neutron imaging to quantify the concentration of active species and supporting electrolytes. To demonstrate the potential of this diagnostic tool, we characterize active species concentration distribution within a redox flow cell in a single electrolyte configuration with a non-aqueous electrolyte containing a TEMPO/TEMPO+ redox couple and study the influence of electrode microstructure, membrane type (e.g. porous or dense), and flow field design. To resolve the concentration profiles across the different layers, we employ the in-plane imaging configuration11 and correlate these concentration profiles to cell performance via polarization measurements under different operating conditions. In the final part of the talk, I will discuss our latest experimental campaign in which we investigated the use of energy-selective neutron radiography to deconvolute concentrations of active species and supporting electrodes during operation. References 1 P. Boillat, E. H. Lehmann, P. Trtik and M. Cochet, Curr. Opin. Electrochem., , DOI:https://doi.org/10.1016/j.coelec.2017.07.012. 2 J. Eller, T. Rosén, F. Marone, M. Stampanoni, A. Wokaun and F. N. Büchi, J. Electrochem. Soc., 2011, 158, B963. 3 B. Michalak, H. Sommer, D. Mannes, A. Kaestner, T. Brezesinski and J. Janek, Sci. Rep., 2015, 5, 15627. 4 D. P. Finegan, M. Scheel, J. B. Robinson, B. Tjaden, I. Hunt, T. J. Mason, J. Millichamp, M. Di Michiel, G. J. Offer, G. Hinds, D. J. L. Brett and P. R. Shearing, Nat. Commun., 2015, 6, 6924. 5 A. A. Wong, M. J. Aziz and S. Rubinstein, ECS Trans. , 2017, 77, 153–161. 6 H. Tanaka, Y. Miyafuji, J. Fukushima, T. Tayama, T. Sugita, M. Takezawa and T. Muta, J. Energy Storage, 2018, 19, 67–72. 7 E. W. Zhao, T. Liu, E. Jónsson, J. Lee, I. Temprano, R. B. Jethwa, A. Wang, H. Smith, J. Carretero-González, Q. Song and C. P. Grey, Nature, 2020, 579, 224–228. 8 R. Jervis, L. D. Brown, T. P. Neville, J. Millichamp, D. P. Finegan, T. M. M. Heenan, D. J. L. Brett and P. R. Shearing, J. Phys. D. Appl. Phys., , DOI:10.1088/0022-3727/49/43/434002. 9 F. Tariq, J. Rubio-Garcia, V. Yufit, A. Bertei, B. K. Chakrabarti, A. Kucernak and N. Brandon, Sustain. Energy Fuels, 2018, 2, 2068–2080. 10 K. Köble, L. Eifert, N. Bevilacqua, K. F. Fahy, A. Bazylak and R. Zeis, J. Power Sources, , DOI:10.1016/j.jpowsour.2021.229660. 11 P. Boillat, D. Kramer, B. C. Seyfang, G. Frei, E. Lehmann, G. G. Scherer, A. Wokaun, Y. Ichikawa, Y. Tasaki and K. Shinohara, Electrochem. commun., 2008, 10, 546–550.
- Open Access
- 14 June 2022
- Published by Wiley in Energy Technology
- Vol. 10 (8)
A Comparative Study of Compressive Effects on the Morphology and Performance of Carbon Paper and Cloth Electrodes in Redox Flow Batteries
Compressing porous carbon electrodes is a common approach to improve flow battery performance, but the resulting impact on electrode structure, fluid dynamics, and cell performance is not well understood. Herein, microtomographic imaging, load cell testing, and flow cell diagnostics are employed to characterize how compression‐induced changes impact pressure drop, polarization, and mass‐transfer scaling. Five different compressions are tested, spanning ranges typically used in literature, for AvCarb 1071 cloth (0%, 9%, 20%, 25%, 32%) and Freudenberg H23 paper (0%, 8%, 12%, 17%, 22%). It is found that the two electrode structures have distinct responses to compression, resulting in differing optimal conditions identified for each material; specifically, the Freudenberg H23 exhibits lower combined ohmic, charge‐transfer, and mass‐transport values at 8% compression, resulting in improved electrochemical performance across all compressive values, as compared to the optimal AvCarb 1071 compression (20%). Overall, Freudenberg H23 exhibits a greater sensitivity to compression with peak electrochemical activity correlating with increased permeability, whereas AvCarb 1071 is insensitive to compressive loads but produces lower electrochemical performance. Herein, the trade‐offs of mechanical robustness on fluid‐dynamic and electrochemical performance between the two electrodes are demonstrated by the aforementioned findings, suggesting each could be used for specific operating environments.
- 14 June 2022
- Published by Wiley in Energy Technology
- Vol. 10 (8)
Open AccessA Comparative Study of Compressive Effects on the Morphology and Performance of Carbon Paper and Cloth Electrodes in Redox Flow Batteries
Compressing porous carbon electrodes is a common approach to improve flow battery performance, but the resulting impact on electrode structure, fluid dynamics, and cell performance is not well understood. Herein, microtomographic imaging, load cell testing, and flow cell diagnostics are employed to characterize how compression‐induced changes impact pressure drop, polarization, and mass‐transfer scaling. Five different compressions are tested, spanning ranges typically used in literature, for AvCarb 1071 cloth (0%, 9%, 20%, 25%, 32%) and Freudenberg H23 paper (0%, 8%, 12%, 17%, 22%). It is found that the two electrode structures have distinct responses to compression, resulting in differing optimal conditions identified for each material; specifically, the Freudenberg H23 exhibits lower combined ohmic, charge‐transfer, and mass‐transport values at 8% compression, resulting in improved electrochemical performance across all compressive values, as compared to the optimal AvCarb 1071 compression (20%). Overall, Freudenberg H23 exhibits a greater sensitivity to compression with peak electrochemical activity correlating with increased permeability, whereas AvCarb 1071 is insensitive to compressive loads but produces lower electrochemical performance. Herein, the trade‐offs of mechanical robustness on fluid‐dynamic and electrochemical performance between the two electrodes are demonstrated by the aforementioned findings, suggesting each could be used for specific operating environments.
- 1 December 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (12) , 123503
Methods—A Potential–Dependent Thiele Modulus to Quantify the Effectiveness of Porous Electrocatalysts
Electrochemical reactors often employ high surface area electrocatalysts to accelerate volumetric reaction rates and increase productivity. While electrocatalysts can alleviate kinetic overpotentials, diffusional resistances at the pore-scale often prevent full catalyst utilization. The effect of intraparticle diffusion on the overall reaction rate can be quantified through an effectiveness factor expression governed by the Thiele modulus parameter. This analytical approach is integral to the development of catalytic structures for thermochemical processes and has previously been extended to electrochemical processes by accounting for the relationship between reaction kinetics and electrode overpotential. In this paper, we illustrate the method by deriving the expression for the potential-dependent Thiele modulus and using it to quantify the effectiveness factor for porous electrocatalytic structures. Specifically, we demonstrate the application of this mathematical framework to spherical microparticles as a function of applied overpotential across catalyst properties and reactant characteristics. The relative effects of kinetics and mass transport are related to overall reaction rates, revealing markedly lower catalyst utilization at increasing overpotential. Subsequently, we generalize the analysis to different catalyst shapes and provide guidance on the design of porous catalytic materials for use in electrochemical reactors.
- 1 December 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (12) , 123503
Methods—A Potential–Dependent Thiele Modulus to Quantify the Effectiveness of Porous Electrocatalysts
Electrochemical reactors often employ high surface area electrocatalysts to accelerate volumetric reaction rates and increase productivity. While electrocatalysts can alleviate kinetic overpotentials, diffusional resistances at the pore-scale often prevent full catalyst utilization. The effect of intraparticle diffusion on the overall reaction rate can be quantified through an effectiveness factor expression governed by the Thiele modulus parameter. This analytical approach is integral to the development of catalytic structures for thermochemical processes and has previously been extended to electrochemical processes by accounting for the relationship between reaction kinetics and electrode overpotential. In this paper, we illustrate the method by deriving the expression for the potential-dependent Thiele modulus and using it to quantify the effectiveness factor for porous electrocatalytic structures. Specifically, we demonstrate the application of this mathematical framework to spherical microparticles as a function of applied overpotential across catalyst properties and reactant characteristics. The relative effects of kinetics and mass transport are related to overall reaction rates, revealing markedly lower catalyst utilization at increasing overpotential. Subsequently, we generalize the analysis to different catalyst shapes and provide guidance on the design of porous catalytic materials for use in electrochemical reactors.
- 17 November 2021
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 4 (12) , 13516-13527
Limited Accessibility to Surface Area Generated by Thermal Pretreatment of Electrodes Reduces Its Impact on Redox Flow Battery Performance
- 17 November 2021
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 4 (12) , 13516-13527
Limited Accessibility to Surface Area Generated by Thermal Pretreatment of Electrodes Reduces Its Impact on Redox Flow Battery Performance
- 24 May 2021
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 4 (6) , 5443-5451
Comparison of Separators vs Membranes in Nonaqueous Redox Flow Battery Electrolytes Containing Small Molecule Active Materials
- 24 May 2021
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 4 (6) , 5443-5451
Comparison of Separators vs Membranes in Nonaqueous Redox Flow Battery Electrolytes Containing Small Molecule Active Materials
- Open Access
- 6 January 2021
- Published by American Chemical Society (ACS) in ChemRxiv
A Comparison of Separators vs. Membranes in Nonaqueous Redox Flow Battery Electrolytes Containing Small Molecule Active Materials
The lack of suitable membranes for nonaqueous electrolytes limits cell capacity and cycle lifetime in organic redox flow cells. Using soluble, stable materials, we sought to compare the best performance that could be achieved with commercially available microporous separators and ion-selective membranes. We use organic species with proven stability to avoid deconvoluting capacity fade due to crossover and/or cell imbalance from materials degradation. We found a trade-off between lifetime and coulombic efficiency: non-selective separators achieve more stable performance but suffer from low coulombic efficiencies, while ion-selective membranes achieve high coulombic efficiencies but experience capacity loss over time. When electrolytes are pre-mixed prior to cycling, coulombic efficiency remains high, but capacity is lost due to cell imbalance, which can be recovered by electrolyte rebalancing. The results of this study highlight the potential for gains in nonaqueous cell performance that may be enabled by suitable membranes.
- 6 January 2021
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA Comparison of Separators vs. Membranes in Nonaqueous Redox Flow Battery Electrolytes Containing Small Molecule Active Materials
The lack of suitable membranes for nonaqueous electrolytes limits cell capacity and cycle lifetime in organic redox flow cells. Using soluble, stable materials, we sought to compare the best performance that could be achieved with commercially available microporous separators and ion-selective membranes. We use organic species with proven stability to avoid deconvoluting capacity fade due to crossover and/or cell imbalance from materials degradation. We found a trade-off between lifetime and coulombic efficiency: non-selective separators achieve more stable performance but suffer from low coulombic efficiencies, while ion-selective membranes achieve high coulombic efficiencies but experience capacity loss over time. When electrolytes are pre-mixed prior to cycling, coulombic efficiency remains high, but capacity is lost due to cell imbalance, which can be recovered by electrolyte rebalancing. The results of this study highlight the potential for gains in nonaqueous cell performance that may be enabled by suitable membranes.
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (60) , 3034
Accessible Surface Area in Porous Carbon Electrodes and Its Impact on Redox Flow Battery Performance
Carbon-fiber electrodes exhibit many desirable material properties including conductivity, porosity, and chemical stability, and, accordingly, are employed in a range of electrochemical technologies.1 Such electrodes are particularly important in redox flow battery (RFB) systems, as they serve multiple critical functions including providing surface area for electrochemical reactions, distributing liquid electrolytes, and conducting electrons and heat. While commercially available materials possess suitable permeability and conductivity, the performance of pristine substrates is limited, thus oxidative treatment prior to use is common practice.2,3 Partial oxidation of the electrode surface has been shown to add a range of oxygen functional groups, which improve hydrophilicity and, in some cases, catalyze redox reactions, as well as to increase available surface area for the electrochemical reactions.4,5 Both effects are posited to improve electrode performance but their relative importance and effectiveness remains unclear.6 Here, we critically assess the nature of the surface area generated by thermal pretreatment in air and its role on RFB electrode performance. Using binder-free Freundenberg H23 as a model substrate, we systematically vary pretreatment time and temperature to create different surface morphologies and develop structure-function relations. First, we use Brauner Emmanuel Teller gas adsorption (e.g., N2, Kr, Ar/CO2) and mercury porosimetry to estimate physical surface area and pore size distribution. In parallel, we use voltammetry and impedance spectroscopy to determine electrochemically active surface area with different electrolyte compositions. In general, we find that only a fraction of the physical surface area is accessible for electrochemical redox reactions due, in large part, to the nanoscopic dimensions of the added surface area. Second, we develop a simple mathematical model to assess the effectiveness of the available surface area of carbon fibers for Faradaic reactions. We find that, under typical RFB operating conditions, external mass transfer limitations govern performance, limiting the utilization of recessed areas generated during pretreatment. Ultimately, these results highlight the potential limits of performance improvement strategies based on increasing surface area of fibrous substrates and motivate new approaches for electrode development. Acknowledgements The authors acknowledge the financial support of the Joint Center for Energy Storage Research, an Energy Innovation Hub funded by the United States Department of Energy. K.V.G acknowledges additional funding from the National Science Foundation Graduate Research Fellowship. The authors acknowledge the Center for Nanoscale Systems and the NSF’s National Nanotechnology Infrastructure Network (NNIN) for the use of Nanoscale Analysis facility for electrode property characterization. References M. H. Chakrabarti et al., Journal of Power Sources, 253, 150–166 (2014). T. J. Rabbow, M. Trampert, P. Pokorny, P. Binder, and A. H. Whitehead, Electrochimica Acta, 173, 17–23 (2015). N. Pour et al., The Journal of Physical Chemistry C, 119, 5311–5318 (2015). B. Sun and M. Skyllas-Kazacos, Electrochim. Acta, 37, 8 (1992). T. J. Rabbow and A. H. Whitehead, Carbon, 111, 782–788 (2017). K. V. Greco, A. Forner-Cuenca, A. Mularczyk, J. Eller, and F. R. Brushett, ACS Applied Materials & Interfaces, 10, 44430–44442 (2018).
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (60) , 3034
Accessible Surface Area in Porous Carbon Electrodes and Its Impact on Redox Flow Battery Performance
Carbon-fiber electrodes exhibit many desirable material properties including conductivity, porosity, and chemical stability, and, accordingly, are employed in a range of electrochemical technologies.1 Such electrodes are particularly important in redox flow battery (RFB) systems, as they serve multiple critical functions including providing surface area for electrochemical reactions, distributing liquid electrolytes, and conducting electrons and heat. While commercially available materials possess suitable permeability and conductivity, the performance of pristine substrates is limited, thus oxidative treatment prior to use is common practice.2,3 Partial oxidation of the electrode surface has been shown to add a range of oxygen functional groups, which improve hydrophilicity and, in some cases, catalyze redox reactions, as well as to increase available surface area for the electrochemical reactions.4,5 Both effects are posited to improve electrode performance but their relative importance and effectiveness remains unclear.6 Here, we critically assess the nature of the surface area generated by thermal pretreatment in air and its role on RFB electrode performance. Using binder-free Freundenberg H23 as a model substrate, we systematically vary pretreatment time and temperature to create different surface morphologies and develop structure-function relations. First, we use Brauner Emmanuel Teller gas adsorption (e.g., N2, Kr, Ar/CO2) and mercury porosimetry to estimate physical surface area and pore size distribution. In parallel, we use voltammetry and impedance spectroscopy to determine electrochemically active surface area with different electrolyte compositions. In general, we find that only a fraction of the physical surface area is accessible for electrochemical redox reactions due, in large part, to the nanoscopic dimensions of the added surface area. Second, we develop a simple mathematical model to assess the effectiveness of the available surface area of carbon fibers for Faradaic reactions. We find that, under typical RFB operating conditions, external mass transfer limitations govern performance, limiting the utilization of recessed areas generated during pretreatment. Ultimately, these results highlight the potential limits of performance improvement strategies based on increasing surface area of fibrous substrates and motivate new approaches for electrode development. Acknowledgements The authors acknowledge the financial support of the Joint Center for Energy Storage Research, an Energy Innovation Hub funded by the United States Department of Energy. K.V.G acknowledges additional funding from the National Science Foundation Graduate Research Fellowship. The authors acknowledge the Center for Nanoscale Systems and the NSF’s National Nanotechnology Infrastructure Network (NNIN) for the use of Nanoscale Analysis facility for electrode property characterization. References M. H. Chakrabarti et al., Journal of Power Sources, 253, 150–166 (2014). T. J. Rabbow, M. Trampert, P. Pokorny, P. Binder, and A. H. Whitehead, Electrochimica Acta, 173, 17–23 (2015). N. Pour et al., The Journal of Physical Chemistry C, 119, 5311–5318 (2015). B. Sun and M. Skyllas-Kazacos, Electrochim. Acta, 37, 8 (1992). T. J. Rabbow and A. H. Whitehead, Carbon, 111, 782–788 (2017). K. V. Greco, A. Forner-Cuenca, A. Mularczyk, J. Eller, and F. R. Brushett, ACS Applied Materials & Interfaces, 10, 44430–44442 (2018).
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (41) , 2674
Small-Scale, Low-Cost Flow Cell Platform for Rapid Characterization of Redox Flow Battery Materials
Economic considerations are a primary driver to the adoption of redox flow battery (RFB) technology for grid storage.1 Minimizing area-specific resistance of flow cells is critical to enabling efficient operation at high power, motivating research into redox electrolytes and cell designs.2,3 The ability to effectively test small quantities of materials is essential, as early prototypes will likely require down-selection and refinement to meet desired performance. Further, identifying the causes of device failure can be challenging as they may be related to either materials degradation (e.g., instability, insolubility, incompatibility) or shortcomings in cell design (e.g., crossover, membrane degradation, high resistance). While established methods exist for quantifying electrochemical and transport properties under well-defined conditions and in isolation, translating this knowledge to laboratory-scale flow cells (and beyond) is nontrivial as experimental conditions are complex and results are often convoluted by other processes within the system. To this end, decoupling molecular discovery and engineering science is key: demonstrations of new active materials and design improvements require dedicated toolkits and testing protocols that enable robust comparative evaluations.4 Thus, the development of broadly accessible research platforms, both hardware and software, may help advance scientific understanding and, ultimately, quicken technology growth. Here, we describe efforts to develop a small-scale (2.55 cm2), low-cost flow cell for screening of RFB component materials. Modeled on and validated against state-of-the-art vanadium RFB designs, the small volumes and chemical resistance of the prototype enables evaluation of a wide range of chemistries with minimal materials requirements (e.g., active materials, membranes). In this presentation, we will discuss the key features of this platform, highlight its utility via representative materials design campaigns, and propose future applications of potential scientific and technological value. Ultimately, the aim of this flow cell is to accelerate progress by enabling rapid turnaround (i.e., fail fast) and easing entry into the field of a diverse set of researchers with key subdomain expertise. In this spirit, detailed flow cell designs, bills of material, standard operating procedures, and validation sets are made freely available to the research community to enable internal assessment and potential adoption. References A. Z. Weber et al., J. Appl. Electrochem., 41, 1137–1164 (2011). M. Skyllas-Kazacos, M. H. Chakrabarti, S. A. Hajimolana, F. S. Mjalli, and M. Saleem, J. Electrochem. Soc., 158, R55 (2011). L. Su, J. A. Kowalski, K. J. Carroll, and F. R. Brushett, in Rechargeable Batteries, Green Energy and Technology. Z. Zhang and S. S. Zhang, Editors, p. 673–712, Springer International Publishing, Cham (2015) http://link.springer.com/10.1007/978-3-319-15458-9_24. J. D. Milshtein et al., Energy Environ. Sci., 9, 3531–3543 (2016).
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (41) , 2674
Small-Scale, Low-Cost Flow Cell Platform for Rapid Characterization of Redox Flow Battery Materials
Economic considerations are a primary driver to the adoption of redox flow battery (RFB) technology for grid storage.1 Minimizing area-specific resistance of flow cells is critical to enabling efficient operation at high power, motivating research into redox electrolytes and cell designs.2,3 The ability to effectively test small quantities of materials is essential, as early prototypes will likely require down-selection and refinement to meet desired performance. Further, identifying the causes of device failure can be challenging as they may be related to either materials degradation (e.g., instability, insolubility, incompatibility) or shortcomings in cell design (e.g., crossover, membrane degradation, high resistance). While established methods exist for quantifying electrochemical and transport properties under well-defined conditions and in isolation, translating this knowledge to laboratory-scale flow cells (and beyond) is nontrivial as experimental conditions are complex and results are often convoluted by other processes within the system. To this end, decoupling molecular discovery and engineering science is key: demonstrations of new active materials and design improvements require dedicated toolkits and testing protocols that enable robust comparative evaluations.4 Thus, the development of broadly accessible research platforms, both hardware and software, may help advance scientific understanding and, ultimately, quicken technology growth. Here, we describe efforts to develop a small-scale (2.55 cm2), low-cost flow cell for screening of RFB component materials. Modeled on and validated against state-of-the-art vanadium RFB designs, the small volumes and chemical resistance of the prototype enables evaluation of a wide range of chemistries with minimal materials requirements (e.g., active materials, membranes). In this presentation, we will discuss the key features of this platform, highlight its utility via representative materials design campaigns, and propose future applications of potential scientific and technological value. Ultimately, the aim of this flow cell is to accelerate progress by enabling rapid turnaround (i.e., fail fast) and easing entry into the field of a diverse set of researchers with key subdomain expertise. In this spirit, detailed flow cell designs, bills of material, standard operating procedures, and validation sets are made freely available to the research community to enable internal assessment and potential adoption. References A. Z. Weber et al., J. Appl. Electrochem., 41, 1137–1164 (2011). M. Skyllas-Kazacos, M. H. Chakrabarti, S. A. Hajimolana, F. S. Mjalli, and M. Saleem, J. Electrochem. Soc., 158, R55 (2011). L. Su, J. A. Kowalski, K. J. Carroll, and F. R. Brushett, in Rechargeable Batteries, Green Energy and Technology. Z. Zhang and S. S. Zhang, Editors, p. 673–712, Springer International Publishing, Cham (2015) http://link.springer.com/10.1007/978-3-319-15458-9_24. J. D. Milshtein et al., Energy Environ. Sci., 9, 3531–3543 (2016).
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (60) , 3032
Combining Electrochemical, Fluid Dynamic, and Imaging Analyses to Understand the Effect of Electrode Microstructure and Electrolyte on Redox Flow Batteries
Understanding the interplay between electrode microstructure and cell performance of electrochemical devices is important both for modelling and experimental design. Redox Flow Batteries (RFBs) are an electrochemical energy storage technology with potential for grid-scale energy storage applications, although costs need to be further reduced to be competitive. One pathway to lowering the costs involves increasing the power density of each cell, such that fewer cells are required. This can be achieved in a variety of ways, including by improving the design of the electrode microstructures. The aim of this work is to better understand the relationship between electrode microstructure and RFB performance and, ultimately, to make inferences about electrode utility. The performances of a variety of commercially available carbon electrodes are examined via a series of commonly used microstructural and electrochemical analyses (Figure a-c). [1] We present a comprehensive study of pore-scale mass-transport processes occurring in each of the electrodes and rationalize their effect on the overall cell performance. A matrix of electrochemical tests were carried out in a flow-through RFB cell using incremental flow rates (Figure b-c) and two non-aqueous TEMPO electrolytes with distinct viscosity and diffusivity properties. Scanning electron microscopy (SEM) was used to image the electrodes and large 3 mm samples of each were scanned using X-ray computed tomography (Figure a). A customized segmentation technique was subsequently developed that resamples the image data to ensure the fiber dimensions agree with SEM images, improving the validity of the various extracted metrics. From these images, calculations and electrochemical tests, several microstructural parameters were extracted and a pore network model was used to calculate the permeabilities of the electrodes. A 1D model was developed across half the symmetric membrane electrode assembly and, using the parameters extracted from XCT, fit to galvanostatic polarization measurements to obtain the mass transfer coefficients at each unique operating condition – these were found to be in the range of and m s-1. Transport processes and distributions through the cell are analysed and correlations between dimensionless Reynolds and Sherwood numbers are subsequently discussed, as demonstrated in previous work. [2, 3] Given a ‘good performance’ is associated with a system being able to reach a high current with a low overpotential, the following findings were made. Firstly, while volume-specific surface area, porosity and tortuosity are useful descriptors for evaluating porous media, they are not good indicators of performance in these systems. Instead the permeability and, by extension, the ease with which convective transport can occur is found to be directly correlated with performance in this system. It is asserted that systems using solvents with higher viscosity have a reduced performance due, in part, due to regions in the electrode being starved of new electrolyte. Consistently, across all electrodes and in each electrolyte a better performance is observed when a higher flow rate is used. This effect is, in part, attributed to the reduction in size of the boundary layer at the electrode surface. Finally, in agreement with previous works, [1, 4] the carbon cloths tested in this work are shown to have higher mass-transfer coefficients and permeabilities than the carbon papers and we conclude that the best performing electrode is the thicker carbon cloth, which has the lowest resistance to convective flow, highest permeability, and highest mass-transfer coefficients in both solvents. [1]: A. Forner-Cuenca, E. E. Penn, A. M. Oliveira and F. R. Brushett, Exploring the Role of Electrode Microstructure on the Performance of Non-Aqueous Redox Flow Batteries. J. Electrochem. Soc., 166, 2230-2241 (2019). [2]: Y. A. Gandomi, D. S. Aaron, T. A. Zawodzinski and M. M. Mench, In Situ Potential Distribution Measurement and Validated Model for All-Vanadium Redox Flow Battery. J. Electrochem. Soc., 163, A5188-A5201 (2016). [3]: K. M. Tenny, A. Forner-Cuenca, Y.-M. Chiang and F. R. Brushett, Comparing Physical and Electrochemical Properties of Different Weave Patterns for Carbon Cloth Electrodes in Redox Flow Batteries. J. Electrochem. En. Conv. Stor., 17, 041108 (2020). [4]: M. A. Sadeghi, M. Aganou, M. D. R. Kok, M. Aghighi, G. Merle, J. Barralet and J. Gostick, Exploring the Impact of Electrode Microstructure on Redox Flow Battery Performance Using a Multiphysics Pore Network Model. J. Electrochem. Soc., 166, A2121-A2130 (2019). Figure 1
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (60) , 3032
Combining Electrochemical, Fluid Dynamic, and Imaging Analyses to Understand the Effect of Electrode Microstructure and Electrolyte on Redox Flow Batteries
Understanding the interplay between electrode microstructure and cell performance of electrochemical devices is important both for modelling and experimental design. Redox Flow Batteries (RFBs) are an electrochemical energy storage technology with potential for grid-scale energy storage applications, although costs need to be further reduced to be competitive. One pathway to lowering the costs involves increasing the power density of each cell, such that fewer cells are required. This can be achieved in a variety of ways, including by improving the design of the electrode microstructures. The aim of this work is to better understand the relationship between electrode microstructure and RFB performance and, ultimately, to make inferences about electrode utility. The performances of a variety of commercially available carbon electrodes are examined via a series of commonly used microstructural and electrochemical analyses (Figure a-c). [1] We present a comprehensive study of pore-scale mass-transport processes occurring in each of the electrodes and rationalize their effect on the overall cell performance. A matrix of electrochemical tests were carried out in a flow-through RFB cell using incremental flow rates (Figure b-c) and two non-aqueous TEMPO electrolytes with distinct viscosity and diffusivity properties. Scanning electron microscopy (SEM) was used to image the electrodes and large 3 mm samples of each were scanned using X-ray computed tomography (Figure a). A customized segmentation technique was subsequently developed that resamples the image data to ensure the fiber dimensions agree with SEM images, improving the validity of the various extracted metrics. From these images, calculations and electrochemical tests, several microstructural parameters were extracted and a pore network model was used to calculate the permeabilities of the electrodes. A 1D model was developed across half the symmetric membrane electrode assembly and, using the parameters extracted from XCT, fit to galvanostatic polarization measurements to obtain the mass transfer coefficients at each unique operating condition – these were found to be in the range of and m s-1. Transport processes and distributions through the cell are analysed and correlations between dimensionless Reynolds and Sherwood numbers are subsequently discussed, as demonstrated in previous work. [2, 3] Given a ‘good performance’ is associated with a system being able to reach a high current with a low overpotential, the following findings were made. Firstly, while volume-specific surface area, porosity and tortuosity are useful descriptors for evaluating porous media, they are not good indicators of performance in these systems. Instead the permeability and, by extension, the ease with which convective transport can occur is found to be directly correlated with performance in this system. It is asserted that systems using solvents with higher viscosity have a reduced performance due, in part, due to regions in the electrode being starved of new electrolyte. Consistently, across all electrodes and in each electrolyte a better performance is observed when a higher flow rate is used. This effect is, in part, attributed to the reduction in size of the boundary layer at the electrode surface. Finally, in agreement with previous works, [1, 4] the carbon cloths tested in this work are shown to have higher mass-transfer coefficients and permeabilities than the carbon papers and we conclude that the best performing electrode is the thicker carbon cloth, which has the lowest resistance to convective flow, highest permeability, and highest mass-transfer coefficients in both solvents. [1]: A. Forner-Cuenca, E. E. Penn, A. M. Oliveira and F. R. Brushett, Exploring the Role of Electrode Microstructure on the Performance of Non-Aqueous Redox Flow Batteries. J. Electrochem. Soc., 166, 2230-2241 (2019). [2]: Y. A. Gandomi, D. S. Aaron, T. A. Zawodzinski and M. M. Mench, In Situ Potential Distribution Measurement and Validated Model for All-Vanadium Redox Flow Battery. J. Electrochem. Soc., 163, A5188-A5201 (2016). [3]: K. M. Tenny, A. Forner-Cuenca, Y.-M. Chiang and F. R. Brushett, Comparing Physical and Electrochemical Properties of Different Weave Patterns for Carbon Cloth Electrodes in Redox Flow Batteries. J. Electrochem. En. Conv. Stor., 17, 041108 (2020). [4]: M. A. Sadeghi, M. Aganou, M. D. R. Kok, M. Aghighi, G. Merle, J. Barralet and J. Gostick, Exploring the Impact of Electrode Microstructure on Redox Flow Battery Performance Using a Multiphysics Pore Network Model. J. Electrochem. Soc., 166, A2121-A2130 (2019). Figure 1