Harold S. Barnard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Harold S. Barnard has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
D.Y. Parkinson
Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley CA, USA
2 shared publicationsN.M. Larson
Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley CA, USA
2 shared publicationsY. Gao
GE Global Research, Niskayuna NY, USA
2 shared publicationsA.A Macdowell
Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley CA, USA
1 shared publicationA.A. MacDowell
Advanced Light Source, Lawrence Berkeley Laboratory, Berkeley CA, USA
1 shared publicationB. Blank
Pulse Ray Inc. Beaver Dams, NY, USA
1 shared publication
Latest Publications
- 1 January 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (1) , 238-243
A new mini-triaxial cell for combined high-pressure and high-temperature in situ synchrotron X-ray microtomography experiments up to 400°C and 24 MPa
A new experimental triaxial cell for in situ synchrotron X-ray micro-computed tomography aimed at imaging small samples of (6 mm × 19 mm) at high temperatures (up to 400°C) and pressures (up to 24 MPa confining) is presented. The system has flow-through capabilities, independent axial and radial pressure control, and has been developed and tested at the 8.3.2. beamline at the Advanced Light Source. The characteristics of this new experimental rig are described, along with the challenges, mainly concerning the combination of X-ray transparency with vessel strength at high temperature, and solutions found during the development stage. An experiment involving oil shale pyrolysis under subsurface conditions, highlighting the importance of a device able to operate in this pressure and temperature range, is also introduced. The availability of this cell enables an unprecedented range of experiments in the Earth Sciences, with a special focus on subsurface geothermal processes.
- 1 January 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (1) , 238-243
A new mini-triaxial cell for combined high-pressure and high-temperature in situ synchrotron X-ray microtomography experiments up to 400°C and 24 MPa
A new experimental triaxial cell for in situ synchrotron X-ray micro-computed tomography aimed at imaging small samples of (6 mm × 19 mm) at high temperatures (up to 400°C) and pressures (up to 24 MPa confining) is presented. The system has flow-through capabilities, independent axial and radial pressure control, and has been developed and tested at the 8.3.2. beamline at the Advanced Light Source. The characteristics of this new experimental rig are described, along with the challenges, mainly concerning the combination of X-ray transparency with vessel strength at high temperature, and solutions found during the development stage. An experiment involving oil shale pyrolysis under subsurface conditions, highlighting the importance of a device able to operate in this pressure and temperature range, is also introduced. The availability of this cell enables an unprecedented range of experiments in the Earth Sciences, with a special focus on subsurface geothermal processes.
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 444-445
Synchrotron X-ray Micro Tomography at the Advanced Light Source: In-Situ Sample Environments for Advanced Aerospace Materials
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 444-445
Synchrotron X-ray Micro Tomography at the Advanced Light Source: In-Situ Sample Environments for Advanced Aerospace Materials
- Open Access
- 14 June 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 849 (1) , 012043
Synchrotron X-ray micro-tomography at the Advanced Light Source: Developments in high-temperature in-situ mechanical testing
At the Advanced Light Source (ALS), Beamline 8.3.2 performs hard X-ray micro-tomography under conditions of high temperature, pressure, mechanical loading, and other realistic conditions using environmental test cells. With scan times of 10s–100s of seconds, the microstructural evolution of materials can be directly observed over multiple time steps spanning prescribed changes in the sample environment. This capability enables in-situ quasi-static mechanical testing of materials. We present an overview of our in-situ mechanical testing capabilities and recent hardware developments that enable flexural testing at high temperature and in combination with acoustic emission analysis.
- 14 June 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 849 (1) , 012043
Open AccessSynchrotron X-ray micro-tomography at the Advanced Light Source: Developments in high-temperature in-situ mechanical testing
At the Advanced Light Source (ALS), Beamline 8.3.2 performs hard X-ray micro-tomography under conditions of high temperature, pressure, mechanical loading, and other realistic conditions using environmental test cells. With scan times of 10s–100s of seconds, the microstructural evolution of materials can be directly observed over multiple time steps spanning prescribed changes in the sample environment. This capability enables in-situ quasi-static mechanical testing of materials. We present an overview of our in-situ mechanical testing capabilities and recent hardware developments that enable flexural testing at high temperature and in combination with acoustic emission analysis.