Dongwei Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dongwei Chen has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Wenbin Du
State Key Laboratory of Microbial Resources, Institute of Microbiology Chinese Academy of Sciences Beijing China
9 shared publications - Shuang-Jiang Liu
State Key Laboratory of Microbial Diversity and Innovative Utilization, Institute of Microbiology, Chinese Academy of Sciences, Beijing, P. R. China
4 shared publications Mengyue Nie
State Key Laboratory of Microbial Resources, Institute of Microbiology Chinese Academy of Sciences Beijing China
3 shared publicationsYing Lan
State Key Laboratory of Microbial Resources, Institute of Microbiology Chinese Academy of Sciences Beijing China
3 shared publicationsYun Zhang
CAS Key Laboratory of Microbial Physiological and Metabolic Engineering at Institute of Microbiology, Chinese Academy of Sciences, Beijing, People's Republic of China
3 shared publicationsYuxin Qiao
State Key Laboratory of Microbial Diversity and Innovative Utilization, Institute of Microbiology, Chinese Academy of Sciences, Beijing, China
3 shared publications
Latest Publications
- Open Access
- 3 November 2025
- Published by Springer Nature in BMC Medicine
- Vol. 23 (1) , 1-14
Ultrahigh-throughput screening of heterogeneous vancomycin-intermediate Staphylococcus aureus based on fluorescence-activated droplet sorting
Heterogeneous vancomycin-intermediate Staphylococcus aureus (hVISA) is associated with suboptimal glycopeptide treatment outcomes. However, conventional antimicrobial susceptibility testing fails to distinguish hVISA from vancomycin-susceptible Staphylococcus aureus (VSSA), potentially delaying effective therapy. The gold standard population analysis profiling with area under the curve (PAP-AUC) method is labor-intensive and time-consuming, necessitating rapid detection alternatives. This study introduces a microfluidic platform based on fluorescence-activated droplet sorting (FADS) for the rapid detection and isolation of hVISA. Through systematic optimization of key parameters such as droplet generation conditions, bacterial suspension concentration, fluorescence probe selection, fluorescence duration, and vancomycin screening concentration, we established a rapid hVISA screening system. The efficacy of this system was evaluated using the hVISA standard strain Mu3, followed by validation with 15 clinical hVISA isolates. Genomic analysis further elucidated the genetic basis of drug resistance in hVISA strains. We developed a high-throughput detection platform for hVISA by integrating a microfluidic system with FADS. Based on a Poisson distribution theoretical model, the bacterial suspension concentration was optimized to 106 CFU/mL, achieving a single-bacterium droplet encapsulation rate of approximately 30%. The selected fluorescent probe exhibited detectable fluorescence signals as early as 6 h post-cultivation, with stability maintained for at least 1 week. Drug concentration validation demonstrated that 4 μg/mL vancomycin effectively inhibited susceptible bacteria without interfering with fluorescence detection. This platform successfully isolated resistant subpopulations from the hVISA reference strain Mu3 within 12 h, and its efficacy was further validated using 15 clinical hVISA isolates. This study innovatively integrated a microfluidic detection platform and FADS to achieve rapid detection of hVISA. This technology reduced the detection time to just 12 h and significantly improved the enrichment efficiency of drug-resistant bacterial populations.
- 3 November 2025
- Published by Springer Nature in BMC Medicine
- Vol. 23 (1) , 1-14
Open AccessUltrahigh-throughput screening of heterogeneous vancomycin-intermediate Staphylococcus aureus based on fluorescence-activated droplet sorting
Heterogeneous vancomycin-intermediate Staphylococcus aureus (hVISA) is associated with suboptimal glycopeptide treatment outcomes. However, conventional antimicrobial susceptibility testing fails to distinguish hVISA from vancomycin-susceptible Staphylococcus aureus (VSSA), potentially delaying effective therapy. The gold standard population analysis profiling with area under the curve (PAP-AUC) method is labor-intensive and time-consuming, necessitating rapid detection alternatives. This study introduces a microfluidic platform based on fluorescence-activated droplet sorting (FADS) for the rapid detection and isolation of hVISA. Through systematic optimization of key parameters such as droplet generation conditions, bacterial suspension concentration, fluorescence probe selection, fluorescence duration, and vancomycin screening concentration, we established a rapid hVISA screening system. The efficacy of this system was evaluated using the hVISA standard strain Mu3, followed by validation with 15 clinical hVISA isolates. Genomic analysis further elucidated the genetic basis of drug resistance in hVISA strains. We developed a high-throughput detection platform for hVISA by integrating a microfluidic system with FADS. Based on a Poisson distribution theoretical model, the bacterial suspension concentration was optimized to 106 CFU/mL, achieving a single-bacterium droplet encapsulation rate of approximately 30%. The selected fluorescent probe exhibited detectable fluorescence signals as early as 6 h post-cultivation, with stability maintained for at least 1 week. Drug concentration validation demonstrated that 4 μg/mL vancomycin effectively inhibited susceptible bacteria without interfering with fluorescence detection. This platform successfully isolated resistant subpopulations from the hVISA reference strain Mu3 within 12 h, and its efficacy was further validated using 15 clinical hVISA isolates. This study innovatively integrated a microfluidic detection platform and FADS to achieve rapid detection of hVISA. This technology reduced the detection time to just 12 h and significantly improved the enrichment efficiency of drug-resistant bacterial populations.
- Open Access
Whole lifecycle observation of single‐spore germinated Streptomyces using a nanogap‐stabilized microfluidic chip
Streptomyces is a model bacterium to study multicellular differentiation and the major reservoir for antibiotics discovery. However, the cellular‐level lifecycle of Streptomyces has not been well studied due to its complexity and lack of research tools that can mimic their natural conditions. In this study, we developed a simple microfluidic chip for the cultivation and observation of the entire lifecycle of Streptomyces development from the single‐cell perspective. The chip consists of channels for loading samples and supplying nutrients, microwell arrays for the seeding and growth of single spores, and air chambers beside the microwells that facilitate the development of aerial hyphae and spores. A unique feature of this chip is that each microwell is surrounded by a 1.5 µm nanogap connected to an air chamber, which provides a stabilized water–air interface. We used this chip to observe the lifecycle development of Streptomyces coelicolor and Streptomyces griseus germinated from single spores, which revealed differentiation of aerial hyphae with progeny spores at micron‐scale water–air interfaces and air chambers. Finally, we demonstrated the applicability of this chip in phenotypic assays by showing that the microbial hormone A‐Factor is involved in the regulatory pathways of aerial hyphae and spore formation. The microfluidic chip could become a robust tool for studying multicellular differentiation, single‐spore heterogeneity, and secondary metabolism of single‐spore germinated Streptomyces.
Open AccessWhole lifecycle observation of single‐spore germinated Streptomyces using a nanogap‐stabilized microfluidic chip
Streptomyces is a model bacterium to study multicellular differentiation and the major reservoir for antibiotics discovery. However, the cellular‐level lifecycle of Streptomyces has not been well studied due to its complexity and lack of research tools that can mimic their natural conditions. In this study, we developed a simple microfluidic chip for the cultivation and observation of the entire lifecycle of Streptomyces development from the single‐cell perspective. The chip consists of channels for loading samples and supplying nutrients, microwell arrays for the seeding and growth of single spores, and air chambers beside the microwells that facilitate the development of aerial hyphae and spores. A unique feature of this chip is that each microwell is surrounded by a 1.5 µm nanogap connected to an air chamber, which provides a stabilized water–air interface. We used this chip to observe the lifecycle development of Streptomyces coelicolor and Streptomyces griseus germinated from single spores, which revealed differentiation of aerial hyphae with progeny spores at micron‐scale water–air interfaces and air chambers. Finally, we demonstrated the applicability of this chip in phenotypic assays by showing that the microbial hormone A‐Factor is involved in the regulatory pathways of aerial hyphae and spore formation. The microfluidic chip could become a robust tool for studying multicellular differentiation, single‐spore heterogeneity, and secondary metabolism of single‐spore germinated Streptomyces.
- 21 September 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (39) , 13112-13117
Tunable and Contamination-Free Injection with Microfluidics by Stepinjection
Droplet microfluidics with picoinjection provides significant advantages to multistep reactions and screenings. The T-junction design for picoinjection is convenient in adding picoliter reagents into passing droplets to initiate reactions. However, conventional picoinjectors face difficulties in eliminating cross-contamination between droplets, preventing them from widespread use in sensitive biological and molecular assays. Here, we introduce stepinjection, which uses a T-junction with a stepped channel design to elevate the diffusional buffer zone into the main channel and consequently increases the pressure difference between droplets and the inlet of the injection channel. To demonstrate the stepinjector’s ability to perform contamination-sensitive enzymatic assays, we inject casein fluorescein isothiocyanate (FITC-casein) into a mixture of savinase and savinase-free (labeled with a red fluorescent dye) droplets. We observe no cross-contamination using stepinjection but find a severe cross-talk using an optimal picoinjection design. We envision that the simple, tunable, and reliable stepinjector can be easily integrated in various droplet processing devices, and facilitate various biomedical and biochemical applications including multiplex digital PCR, single-cell sequencing, and enzymatic screening.
- 21 September 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (39) , 13112-13117
Tunable and Contamination-Free Injection with Microfluidics by Stepinjection
Droplet microfluidics with picoinjection provides significant advantages to multistep reactions and screenings. The T-junction design for picoinjection is convenient in adding picoliter reagents into passing droplets to initiate reactions. However, conventional picoinjectors face difficulties in eliminating cross-contamination between droplets, preventing them from widespread use in sensitive biological and molecular assays. Here, we introduce stepinjection, which uses a T-junction with a stepped channel design to elevate the diffusional buffer zone into the main channel and consequently increases the pressure difference between droplets and the inlet of the injection channel. To demonstrate the stepinjector’s ability to perform contamination-sensitive enzymatic assays, we inject casein fluorescein isothiocyanate (FITC-casein) into a mixture of savinase and savinase-free (labeled with a red fluorescent dye) droplets. We observe no cross-contamination using stepinjection but find a severe cross-talk using an optimal picoinjection design. We envision that the simple, tunable, and reliable stepinjector can be easily integrated in various droplet processing devices, and facilitate various biomedical and biochemical applications including multiplex digital PCR, single-cell sequencing, and enzymatic screening.
- Open Access
EpicPCR-Directed Cultivation of a Candidatus Saccharibacteria Symbiont Reveals a Type IV Pili-dependent Epibiotic Lifestyle
Candidate phyla radiations (CPR), accounting for a major microbial supergroup with remarkably small genomes and reduced sizes, are widely distributed yet mostly uncultured. Limited culture and its obligate reliance upon other bacteria hindered investigation of their lifestyles. In this work we isolated a CPR bacterium, TM7i, with its host Leucobacter aridocollis J1, by combination of Emulsion, Paired Isolation and Concatenation PCR (epicPCR) detection and filtrate co-culture. Genomic profiling of TM7 genomes and microscopic investigation of TM7i-J1 symbiosis suggest the conservation of type IV pili and a pili-dependent lifestyle of TM7. Further, we observed twitching motility of TM7i mediated by pili and its role played in the interaction with its host. Our results shed a light on the lifestyle about this enigmatic bacterial radiation, which may also be adopted by other CPR organisms. The epicPCR-directed isolation method underlines high efficiency of CPR bacteria isolation and thus may be used in other symbiotic or epibiotic microorganisms.
Open AccessEpicPCR-Directed Cultivation of a Candidatus Saccharibacteria Symbiont Reveals a Type IV Pili-dependent Epibiotic Lifestyle
Candidate phyla radiations (CPR), accounting for a major microbial supergroup with remarkably small genomes and reduced sizes, are widely distributed yet mostly uncultured. Limited culture and its obligate reliance upon other bacteria hindered investigation of their lifestyles. In this work we isolated a CPR bacterium, TM7i, with its host Leucobacter aridocollis J1, by combination of Emulsion, Paired Isolation and Concatenation PCR (epicPCR) detection and filtrate co-culture. Genomic profiling of TM7 genomes and microscopic investigation of TM7i-J1 symbiosis suggest the conservation of type IV pili and a pili-dependent lifestyle of TM7. Further, we observed twitching motility of TM7i mediated by pili and its role played in the interaction with its host. Our results shed a light on the lifestyle about this enigmatic bacterial radiation, which may also be adopted by other CPR organisms. The epicPCR-directed isolation method underlines high efficiency of CPR bacteria isolation and thus may be used in other symbiotic or epibiotic microorganisms.
- Open Access
Microfluidic Streptomyces Cultivation for Whole Lifecycle Characterization and Phenotypic Assays Enabled by Nanogap-stabilized Air-Water Interface
Streptomyces is a model filamentous prokaryote to study multicellular differentiation and a rich reservoir for antibiotics discovery. In their natural conditions, Streptomyces grows at the interface of porous soil, air, and water. The morphological development of Streptomyces is traditionally performed on agar plates and mostly studied at the population levels. However, the detailed lifecycle of Streptomyces has not been well studied due to its complexity and lack of research tools which can mimic their natural conditions in the soil. Here, we developed a simple assembled microfluidic device for cultivation and the entire lifecycle observation of Streptomyces development from single-cell level. The microfluidic device composed of a microchannel for loading samples and supplying nutrients, microwell arrays for seeding and growth of single spores, and air-filled chambers aside of the microwells that facilitate growth of aerial hyphae and spores. A unique feature of this device is that each microwell is surrounded by a 1.5 µm gap connected to an air-filled chamber which provide stabilized water-air interface. We used this device to observe the development of single Streptomyces spores and found that unlike those in bulk liquid culture, Streptomyces can differentiate at water-air interfaces in microscale liquid culture. Finally, we demonstrated that phenotypic A-Factor assay can be performed at defined time point of its lifecycle. This microfluidic device could become a robust tool for studying Streptomyces multi-cellular differentiation and interaction at single cell level. IMPORTANCE: We describe a microfluidic device that mimics the natural porous environment for the growth and development of Streptomyces , the model system for bacterial multicellularity. The microfluidic device is used for cultivation and the entire lifecycle observation of Streptomyces development from single-cell level, including growth of aerial filaments. The aerial hyphae development of Streptomyces at the water-air interface was observed at real time in the microfluidic device. The early growth, opportunistic transformation (in the gap), and merging of aerial hyphae of Streptomyces in the microfluidic device were observed for the first time. It will play an important role in finding single-cell heterogeneity to study secondary metabolites related to the complex lifecycle of Streptomyces .
Open AccessMicrofluidic Streptomyces Cultivation for Whole Lifecycle Characterization and Phenotypic Assays Enabled by Nanogap-stabilized Air-Water Interface
Streptomyces is a model filamentous prokaryote to study multicellular differentiation and a rich reservoir for antibiotics discovery. In their natural conditions, Streptomyces grows at the interface of porous soil, air, and water. The morphological development of Streptomyces is traditionally performed on agar plates and mostly studied at the population levels. However, the detailed lifecycle of Streptomyces has not been well studied due to its complexity and lack of research tools which can mimic their natural conditions in the soil. Here, we developed a simple assembled microfluidic device for cultivation and the entire lifecycle observation of Streptomyces development from single-cell level. The microfluidic device composed of a microchannel for loading samples and supplying nutrients, microwell arrays for seeding and growth of single spores, and air-filled chambers aside of the microwells that facilitate growth of aerial hyphae and spores. A unique feature of this device is that each microwell is surrounded by a 1.5 µm gap connected to an air-filled chamber which provide stabilized water-air interface. We used this device to observe the development of single Streptomyces spores and found that unlike those in bulk liquid culture, Streptomyces can differentiate at water-air interfaces in microscale liquid culture. Finally, we demonstrated that phenotypic A-Factor assay can be performed at defined time point of its lifecycle. This microfluidic device could become a robust tool for studying Streptomyces multi-cellular differentiation and interaction at single cell level. IMPORTANCE: We describe a microfluidic device that mimics the natural porous environment for the growth and development of Streptomyces , the model system for bacterial multicellularity. The microfluidic device is used for cultivation and the entire lifecycle observation of Streptomyces development from single-cell level, including growth of aerial filaments. The aerial hyphae development of Streptomyces at the water-air interface was observed at real time in the microfluidic device. The early growth, opportunistic transformation (in the gap), and merging of aerial hyphae of Streptomyces in the microfluidic device were observed for the first time. It will play an important role in finding single-cell heterogeneity to study secondary metabolites related to the complex lifecycle of Streptomyces .
- Open Access
Fluorescence-Activated Droplet Sorting of Polyethylene Terephthalate-degrading Enzymes
Enzymes that can decompose synthetic plastics such as polyethylene terephthalate (PET) are urgently needed. However, a bottleneck remains due to a lack of techniques for detecting and sorting environmental microorganisms with vast diversity and abundance. Here, we developed a fluorescence-activated droplet sorting (FADS) pipeline for high-throughput screening of PET-degrading microorganisms or enzymes (PETases). The pipeline comprises three steps: generation and incubation of droplets encapsulating single cells, picoinjection of fluorescein dibenzoate (FDBz) as the fluorogenic probe, and screening of droplets to obtain PET-degrading cells. We characterized critical factors associated with this method, including specificity and sensitivity for discriminating PETase from other enzymes. We then optimized its performance and compatibility with environmental samples. The system was used to screen a wastewater sample from a PET textile mill. We successfully obtained PET-degrading species from nine different genera. Moreover, two putative PETases from isolates Kineococcus endophyticus Un-5 and Staphylococcus epidermidis Un-C2-8 were genetically derived, heterologously expressed, and preliminarily validated for PET-degrading activities. We speculate that the FADS pipeline can be widely adopted to discover new PET-degrading microorganisms and enzymes in various environments and may be utilized in the directed evolution of PETases using synthetic biology.
Open AccessFluorescence-Activated Droplet Sorting of Polyethylene Terephthalate-degrading Enzymes
Enzymes that can decompose synthetic plastics such as polyethylene terephthalate (PET) are urgently needed. However, a bottleneck remains due to a lack of techniques for detecting and sorting environmental microorganisms with vast diversity and abundance. Here, we developed a fluorescence-activated droplet sorting (FADS) pipeline for high-throughput screening of PET-degrading microorganisms or enzymes (PETases). The pipeline comprises three steps: generation and incubation of droplets encapsulating single cells, picoinjection of fluorescein dibenzoate (FDBz) as the fluorogenic probe, and screening of droplets to obtain PET-degrading cells. We characterized critical factors associated with this method, including specificity and sensitivity for discriminating PETase from other enzymes. We then optimized its performance and compatibility with environmental samples. The system was used to screen a wastewater sample from a PET textile mill. We successfully obtained PET-degrading species from nine different genera. Moreover, two putative PETases from isolates Kineococcus endophyticus Un-5 and Staphylococcus epidermidis Un-C2-8 were genetically derived, heterologously expressed, and preliminarily validated for PET-degrading activities. We speculate that the FADS pipeline can be widely adopted to discover new PET-degrading microorganisms and enzymes in various environments and may be utilized in the directed evolution of PETases using synthetic biology.
- 1 March 2019
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 366, 512-519
Chemotactic screening of imidazolinone-degrading bacteria by microfluidic SlipChip
- 1 March 2019
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 366, 512-519
Chemotactic screening of imidazolinone-degrading bacteria by microfluidic SlipChip
- Open Access
- 13 June 2018
- Published by Wiley in Microbiologyopen
- Vol. 8 (3) , e00654
Harnessing microfluidic streak plate technique to investigate the gut microbiome of Reticulitermes chinensis
The termite gut microbiome is a model system to investigate microbial interactions and their associations with host. For decades, extensive research with molecular tools and conventional cultivation method has been carried out to define the microbial diversity in termite gut. Yet, many bacterial groups of the termite gut microbiome have not been successfully cultivated in laboratory. In this study, we adapted the recently developed microfluidic streak plate (MSP) technique for cultivation of termite gut microbial communities at both aerobic and anaerobic conditions. We found that 99 operational taxonomic units (OTUs) were cultivable by MSP approach and 18 OTUs were documented first time for termite gut microbiota. Further analysis of the bacterial diversities derived by culture‐dependent MSP approach and culture‐independent 16S rRNA gene typing revealed that both methods have bias in recovery of gut microbiota. In total 396 strains were isolated with MSP technique, and potential new taxa at species and/or genus levels were obtained that were phylogenetically related to Burkholderia , Micrococcus , and Dysgonomonas . Results from this study indicate that MSP technique is applicable for cultivating previously unknown and new microbial groups of termite gut microbiota.
- 13 June 2018
- Published by Wiley in Microbiologyopen
- Vol. 8 (3) , e00654
Open AccessHarnessing microfluidic streak plate technique to investigate the gut microbiome of Reticulitermes chinensis
The termite gut microbiome is a model system to investigate microbial interactions and their associations with host. For decades, extensive research with molecular tools and conventional cultivation method has been carried out to define the microbial diversity in termite gut. Yet, many bacterial groups of the termite gut microbiome have not been successfully cultivated in laboratory. In this study, we adapted the recently developed microfluidic streak plate (MSP) technique for cultivation of termite gut microbial communities at both aerobic and anaerobic conditions. We found that 99 operational taxonomic units (OTUs) were cultivable by MSP approach and 18 OTUs were documented first time for termite gut microbiota. Further analysis of the bacterial diversities derived by culture‐dependent MSP approach and culture‐independent 16S rRNA gene typing revealed that both methods have bias in recovery of gut microbiota. In total 396 strains were isolated with MSP technique, and potential new taxa at species and/or genus levels were obtained that were phylogenetically related to Burkholderia , Micrococcus , and Dysgonomonas . Results from this study indicate that MSP technique is applicable for cultivating previously unknown and new microbial groups of termite gut microbiota.
Dynamic Sessile‐Droplet Habitats for Controllable Cultivation of Bacterial Biofilm
Bacterial biofilms play essential roles in biogeochemical cycling, degradation of environmental pollutants, infection diseases, and maintenance of host health. The lack of quantitative methods for growing and characterizing biofilms remains a major challenge in understanding biofilm development. In this study, a dynamic sessile‐droplet habitat is introduced, a simple method which cultivates biofilms on micropatterns with diameters of tens to hundreds of micrometers in a microfluidic channel. Nanoliter plugs are utilized, spaced by immiscible carrier oil to initiate and support the growth of an array of biofilms, anchored on and spatially confined to the micropatterns arranged on the bottom surface of the microchannel, while planktonic or dispersal cells are flushed away by shear force of aqueous plugs. The performance of the aforementioned method of cultivating biofilms is demonstrated by Pseudomonas aeruginosa PAO1 and its derived mutants, and quantitative antimicrobial susceptibility testing of PAO1 biofilms. This method could significantly eliminate corner effects, avoid microchannel clogging, and constrain the growth of biofilms for long‐term observations. The controllable sessile droplet‐based biofilm cultivation presented in this study should shed light on more quantitative and long‐term studies of biofilms, and open new avenues for investigation of biofilm attachment, growth, expansion, and eradication.
Dynamic Sessile‐Droplet Habitats for Controllable Cultivation of Bacterial Biofilm
Bacterial biofilms play essential roles in biogeochemical cycling, degradation of environmental pollutants, infection diseases, and maintenance of host health. The lack of quantitative methods for growing and characterizing biofilms remains a major challenge in understanding biofilm development. In this study, a dynamic sessile‐droplet habitat is introduced, a simple method which cultivates biofilms on micropatterns with diameters of tens to hundreds of micrometers in a microfluidic channel. Nanoliter plugs are utilized, spaced by immiscible carrier oil to initiate and support the growth of an array of biofilms, anchored on and spatially confined to the micropatterns arranged on the bottom surface of the microchannel, while planktonic or dispersal cells are flushed away by shear force of aqueous plugs. The performance of the aforementioned method of cultivating biofilms is demonstrated by Pseudomonas aeruginosa PAO1 and its derived mutants, and quantitative antimicrobial susceptibility testing of PAO1 biofilms. This method could significantly eliminate corner effects, avoid microchannel clogging, and constrain the growth of biofilms for long‐term observations. The controllable sessile droplet‐based biofilm cultivation presented in this study should shed light on more quantitative and long‐term studies of biofilms, and open new avenues for investigation of biofilm attachment, growth, expansion, and eradication.
- Open Access
- 14 April 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 24192
Automated Chemotactic Sorting and Single-cell Cultivation of Microbes using Droplet Microfluidics
We report a microfluidic device for automated sorting and cultivation of chemotactic microbes from pure cultures or mixtures. The device consists of two parts: in the first part, a concentration gradient of the chemoeffector was built across the channel for inducing chemotaxis of motile cells; in the second part, chemotactic cells from the sample were separated and mixed with culture media to form nanoliter droplets for encapsulation, cultivation, enumeration and recovery of single cells. Chemotactic responses were assessed by imaging and statistical analysis of droplets based on Poisson distribution. An automated procedure was developed for rapid enumeration of droplets with cell growth, following with scale-up cultivation on agar plates. The performance of the device was evaluated by the chemotaxis assays of Escherichia coli (E. coli) RP437 and E. coli RP1616. Moreover, enrichment and isolation of non-labelled Comamonas testosteroni CNB-1 from its 1:10 mixture with E. coli RP437 was demonstrated. The enrichment factor reached 36.7 for CNB-1, based on its distinctive chemotaxis toward 4-hydroxybenzoic acid. We believe that this device can be widely used in chemotaxis studies without necessarily relying on fluorescent labelling and isolation of functional microbial species from various environments.
- 14 April 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 24192
Open AccessAutomated Chemotactic Sorting and Single-cell Cultivation of Microbes using Droplet Microfluidics
We report a microfluidic device for automated sorting and cultivation of chemotactic microbes from pure cultures or mixtures. The device consists of two parts: in the first part, a concentration gradient of the chemoeffector was built across the channel for inducing chemotaxis of motile cells; in the second part, chemotactic cells from the sample were separated and mixed with culture media to form nanoliter droplets for encapsulation, cultivation, enumeration and recovery of single cells. Chemotactic responses were assessed by imaging and statistical analysis of droplets based on Poisson distribution. An automated procedure was developed for rapid enumeration of droplets with cell growth, following with scale-up cultivation on agar plates. The performance of the device was evaluated by the chemotaxis assays of Escherichia coli (E. coli) RP437 and E. coli RP1616. Moreover, enrichment and isolation of non-labelled Comamonas testosteroni CNB-1 from its 1:10 mixture with E. coli RP437 was demonstrated. The enrichment factor reached 36.7 for CNB-1, based on its distinctive chemotaxis toward 4-hydroxybenzoic acid. We believe that this device can be widely used in chemotaxis studies without necessarily relying on fluorescent labelling and isolation of functional microbial species from various environments.