KWKelvin Ho-Nam Wan

Kelvin Ho-Nam Wan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kelvin Ho-Nam Wan has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Coronavirus Disease 2019 Pandemic and Infodemic: Separating the Signal From the Noise

    by Kelvin H. MBChB Wan, Nishant Vijay Radke, Raymond L. M. Mbbs Wong, Jost B. Jonas

  • Wavefront aberrometry repeatability and agreement—A comparison between Pentacam AXL Wave, iTrace and OPD‐Scan III

    by Kelvin H. Wan, Xu Lin Liao, Marco Yu, Rachel W. Y. Tsui, Vanissa W. S. Chow, Kelvin K. L. Chong, Tommy C. Y. Chan

    Introduction: To compare intrasession agreement and repeatability of wavefront aberration measurements from three different aberrometers obtained using Hartmann–Shack, ray tracing and automated retinoscopy methods, as well as their interdevice agreement. Methods: Three consecutive measurements were obtained using the Pentacam AXL Wave, the iTrace and the OPD‐Scan III in 47 eyes of 47 patients. Wavefront refractions, root mean square of total aberrations (RMS total), RMS of higher‐order aberrations (HOA) and second‐, third‐ and fourth‐order HOAs were exported for 4‐mm pupils. Wavefront refractions were converted into vector components: M, J 0 and J 45 . Intrasession agreement and repeatability were evaluated using intraclass correlation coefficients (ICCs) and repeatability coefficients (RCs); interdevice agreement was assessed using the Bland–Altman method. Results: The intrasession agreement and repeatability of RMS HOA were comparable between the three devices; both the Pentacam AXL Wave and the OPD‐Scan III had better intrasession agreement and repeatability for the RMS total than the iTrace ( p ≤ 0.02). Intrasession repeatability for the majority of second‐ and third‐order aberrations was better on the Pentacam AXL Wave than on the iTrace ( p ≤ 0.01) and OPD‐Scan III ( p ≤ 0.04), although their agreement and repeatability in spherical aberration were comparable ( p ≥ 0.24). Significant systematic differences and proportional bias were detected for almost all refraction power vectors and Zernike coefficients among the three devices. Conclusions: In this study, all three devices provided good‐to‐excellent agreement for aberration measurements. Most of the individual Zernike's components were not exchangeable between different aberrometers. Their relative intrasession performance in agreement and repeatability varied significantly across different ocular aberration parameters.


  • Open Access

    Impact of Digital Technology on Eye Diseases During COVID-19

    by Kelvin H. MBChB Wan, Jost B. Jonas


  • Bilateral synchronous conjunctival myxoma and review of the literature

    by Timothy P.H. Lin, Kelvin H. Wan, Wah Cheuk, Enne Leung, Hunter K.L. Yuen, Dennis S.C. Lam

    Purpose: The purpose of this study was to report the clinicopathological features and management of the first case of bilateral synchronous conjunctival myxoma. Methods: This study was a case report and literature review. Results: A 66-year-old Chinese male with past ocular history of uncomplicated bilateral phacoemulsification and intraocular lens (IOLs) 3 years ago prior to presentation presented with bilateral red and swollen conjunctiva for over a year. On examination his corrected distance visual acuity (CDVA) was 25/20 in the right eye 20/20 in the left eye. Slit lamp examination revealed swollen temporal conjunctiva bilaterally which appeared as painless, well-circumscribed, salmon-pink, fleshy patches. The lesion in the right eye was subsequently excised, followed by excision of the lesion in the left eye at 3-week interval. Microscopically, histopathological examination of both excised specimens revealed hypocellular conjunctival mucosa covered by non-dysplastic epithelium, with presence of myxoid degeneration in the subepithelial stroma and immunostaining findings consistent with conjunctival myxoma. At his latest follow-up at 24 months, there were no recurrences of the conjunctival masses and the CDVA was the same as preoperatively.


  • Open Access

    Accelerated corneal collagen cross-linking in progressive keratoconus: Five-year results and predictors of visual and topographic outcomes

    by Tommy C Y Chan, Rachel W Y Tsui, Vanissa W S Chow, Jasmine K M Lam, Victoria W Y Wong, Kelvin H Wan

    Purpose: To analyze the 5-year results of accelerated corneal collagen crosslinking (CXL) for progressive keratoconus and identify preoperative characteristics predictive of visual and topographic outcomes. Methods: A prospective interventional case series. Nineteen eyes of 19 patients receiving accelerated CXL with settings of 18 mW/cm2 for 5 min were included. Clinical and topographic parameters were assessed. Linear regression and logistic regression were used to compare the R2 and odds ratio (OR), respectively, between baseline characteristics and postoperative outcomes. Results: Corrected distance visual acuity (CDVA) remained stable from 0.28 ± 0.21 to 0.25 ± 0.18 logMAR (P = 0.486). The mean cylindrical refraction was stable (P = 0.119). The maximal keratometry (Kmax) decreased from 61.99 ± 10.37 to 59.25 ± 7.75 D (P < 0.001), flattening in the flattest and steepest meridians and mean keratometry were also observed (P ≤ 0.040). The mean anterior elevation at the apex reduced from 21.42 ± 16.69 to 18.53 ± 12.74 mm (P = 0.013) and changes in posterior elevation were non-significant (P = 0.629). Preoperative Kmax best predicted the postoperative change in Kmax (R2 = 0.55, P < 0.001) compared to the other baseline characteristics (P ≤ 0.028), whereas preoperative CDVA was the only significant predictor of postoperative change in CDVA (R2 = 0.41, P = 0.003). Accelerated CXL is less likely to fail in eyes with a steeper preoperative Kmax (OR = 0.74, P = 0.040) or greater posterior elevation at the apex (OR = 0.91, P = 0.042). Conclusion: Kmax significantly decreased following accelerated CXL. Eyes with worse preoperative CDVA and higher Kmax were more likely to have an improvement in visual acuity and corneal flattening.


  • Combined accelerated collagen crosslinking and sub-Bowman’s keratomileusis in high myopic eyes: a comparison between total ultraviolet energy dose

    by Kelvin H Wan, Tommy Cy Chan, Peter Sk Kwok, Alex Lk Ng

    To compare the safety, efficacy, and predictability outcomes of combined sub-Bowman’s keratomileusis (thin flap laser in situ keratomileusis [LASIK]) and accelerated crosslinking (CXL) using two di...


  • Outcomes and prognostic factors of cataract surgery in cytomegalovirus-related anterior uveitis

    by Kelvin H. MBChB Wan, Ke Mbbs Liu, Nai Man Mbbs Lam, Vanissa W.S. Mbbs Chow

    Purpose: To evaluate the outcomes of cataract surgery in patients with cytomegalovirus (CMV) anterior uveitis and factors associated with final visual outcome. Setting: Hong Kong Eye Hospital, Hong Kong. Design: Retrospective case series. Methods: History, clinical characteristics, corrected distance visual acuity (CDVA), medications, and complications of CMV anterior uveitic eyes that underwent cataract surgery between 2010 and 2020 were reviewed. Results: This study included 26 eyes of 26 patients undergoing phacoemulsification. The median duration of disease was 4.8 years, and the median quiescent period preoperatively was 2.3 years. None required pupil manipulation or had significant intraoperative complications. The median CDVA improved from 20/100 (interquartile range [IQR] 20/200 to 20/50) preoperatively to 20/30 (IQR 20/40 to 20/25) at 1 year and 20/35 (IQR 20/50 to 20/30) at the last follow-up at a median of 4.9 years postoperatively (P < .001). CDVA improved in 19 eyes (73.1%) and was ≥20/40 in 18 eyes (69.2%). In the multivariate regression model, preoperative use of topical 0.15% ganciclovir (β = 0.33, 95% CI 0.17 to 0.48, P < .001) and adjunctive intraoperative intracameral dexamethasone 0.4 mg (β = 0.19, 95% CI 0.01 to 0.36, P = .043) were associated with a better final CDVA. Loss of CDVA and poor postoperative CDVA visual acuity were mostly attributed to uveitic glaucoma, but preoperative glaucoma or the number of antiglaucoma medications did not affect final CDVA. Conclusions: Cataract surgery in eyes with CMV anterior uveitis was safe and CDVA significantly improved and remained sustained postoperatively. Topical ganciclovir 0.15% preoperatively and intracameral corticosteroid intraoperatively seem to maximize the final visual outcome.


  • Ocular surface disturbance in patients after acute COVID‐19

    by Kelvin H. Wan, Grace C. Y. Lui, Ken C. F. Poon, Susanna S. S. Ng, Alvin L. Young, David S. C. Hui, Clement C. Y. Tham, Paul K. S. Chan, Chi Pui Pang, Kelvin K. L. Chong

    Background: We investigated the ocular surface disturbances in COVID‐19 patients discharged from the hospital.Methods: One hundred and seventy‐nine eyes of 109 healthy participants and 456 eyes of 228 post‐COVID‐19 patients received comprehensive eye examinations; the latter were interviewed with questionnaires on ocular symptoms before and after COVID‐19 diagnosis. Associations of ocular surface manifestations with virological and ophthalmic parameters were evaluated by multivariable mixed linear or logistic regression models.Results: Mean interval between COVID‐19 diagnosis and ophthalmic evaluation was 52.23 ± 16.12 days. The severity of meibomian gland dysfunction (MGD) based on clinical staging was higher in post‐COVID‐19 than healthy eyes (1.14 ± 0.67 vs. 0.92 ± 0.68, p = 0.002) and so was ocular surface staining score (0.60 ± 0.69 vs. 0.49 ± 0.68, p = 0.044). Patients requiring supplementary oxygen during hospitalisation had shorter tear break‐up time (β −1.63, 95% CI ‐2.61 to −0.65). Cycle threshold (Ct) value from upper respiratory samples (inversely correlated with viral load) at diagnosis had an OR = 0.91 (95% CI 0.84–0.98) with new ocular surface symptoms 4 weeks after diagnosis. The presence of ocular surface symptoms 1 week prior to COVID‐19 diagnosis showed an OR of 20.89 (95% CI 6.35–68.66) of persistent or new ocular symptoms 4 weeks afterward.Conclusions: MGD and ocular surface staining are more common and severe in post‐COVID‐19 patients. Patients with higher viral loads have greater risks of ocular surface symptoms. Patients requiring supplementary oxygen are more likely to show tear film instability. Ocular surface evaluation should be considered 1–3 months following hospital discharge for any COVID‐19 patient.


  • Toric intraocular lenses for astigmatism correction after keratoplasty in phakic and pseudophakic eyes

    by Kelvin H. MBChB Wan, John S.M. Chang, Vishal Md Jhanji

    Residual astigmatism and anisometropia significantly affect patients' vision and quality of life even in clear grafts after corneal transplant. This study reviewed and summarized the role of toric intraocular lenses (IOLs) in phakic and pseudophakic eyes after penetrating keratoplasty (PKP) and deep anterior lamellar keratoplasty in correcting residual astigmatism. 342 eyes from 20 studies with iris-clipped toric IOL, ciliary sulcus toric implantable collamer lens, piggyback sulcus toric IOL, or posterior chamber toric IOL implantations for phakic, pseudophakic, or eyes undergoing cataract surgery after keratoplasty were included. Visual, refractive, and predictability outcomes were encouraging. Secondary realignment rate and complications were low. Endothelial cell loss secondary to phakic toric IOLs might be a concern over the long-term, particularly in iris-clipped IOLs in PKP eyes. Toric IOLs represent a viable option in the treatment of residual astigmatism in postkeratoplasty eyes, resulting in improved visual acuity and reduced anisometropia.