LTLaura Tüshaus

Laura Tüshaus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Laura Tüshaus has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Wound Image Quality From a Mobile Health Tool for Home-Based Chronic Wound Management With Real-Time Quality Feedback: Randomized Feasibility Study

    by Jia Zhang, Carina Mihai, Laura Tüshaus, Gaetano Scebba, Oliver Distler, Walter Karlen

    Background: Travel to clinics for chronic wound management is burdensome to patients. Remote assessment and management of wounds using mobile and telehealth approaches can reduce this burden and improve patient outcomes. An essential step in wound documentation is the capture of wound images, but poor image quality can have a negative influence on the reliability of the assessment. To date, no study has investigated the quality of remotely acquired wound images and whether these are suitable for wound self-management and telemedical interpretation of wound status. Objective: Our goal was to develop a mobile health (mHealth) tool for the remote self-assessment of digital ulcers (DUs) in patients with systemic sclerosis (SSc). We aimed to define and validate objective measures for assessing the image quality, evaluate whether an automated feedback feature based on real-time assessment of image quality improves the overall quality of acquired wound images, and evaluate the feasibility of deploying the mHealth tool for home-based chronic wound self-monitoring by patients with SSc. Methods: We developed an mHealth tool composed of a wound imaging and management app, a custom color reference sticker, and a smartphone holder. We introduced 2 objective image quality parameters based on the sharpness and presence of the color checker to assess the quality of the image during acquisition and enable a quality feedback mechanism in an advanced version of the app. We randomly assigned patients with SSc and DU to the 2 device groups (basic and feedback) to self-document their DU at home over 8 weeks. The color checker detection ratio (CCDR) and color checker sharpness (CCS) were compared between the 2 groups. We evaluated the feasibility of the mHealth tool by analyzing the usability feedback from questionnaires, user behavior and timings, and the overall quality of the wound images. Results: A total of 21 patients were enrolled, of which 15 patients were included in the image quality analysis. The average CCDR was 0.96 (191/199) in the feedback group and 0.86 (158/183) in the basic group. The feedback group showed significantly higher (P<.001) CCS compared to the basic group. The usability questionnaire results showed that the majority of patients were satisfied with the tool, but could benefit from disease-specific adaptations. The median assessment duration was <50 seconds in all patients, indicating the mHealth tool was efficient to use and could be integrated into the daily routine of patients. Conclusions: We developed an mHealth tool that enables patients with SSc to acquire good-quality DU images and demonstrated that it is feasible to deploy such an app in this patient group. The feedback mechanism improved the overall image quality. The introduced technical solutions consist of a further step towards reliable and trustworthy digital health for home-based self-management of wounds.


  • Open Access

    Wound Image Quality From a Mobile Health Tool for Home-Based Chronic Wound Management With Real-Time Quality Feedback: Randomized Feasibility Study (Preprint)

    by Jia Zhang, Carina Mihai, Laura Tüshaus, Gaetano Scebba, Oliver Distler, Walter Karlen

    BACKGROUND Travel to clinics for chronic wound management is burdensome to patients. Remote assessment and management of wounds using mobile and telehealth approaches can reduce this burden and improve patient outcomes. An essential step in wound documentation is the capture of wound images, but poor image quality can have a negative influence on the reliability of the assessment. To date, no study has investigated the quality of remotely acquired wound images and whether these are suitable for wound self-management and telemedical interpretation of wound status. OBJECTIVE Our goal was to develop a mobile health (mHealth) tool for the remote self-assessment of digital ulcers (DUs) in patients with systemic sclerosis (SSc). We aimed to define and validate objective measures for assessing the image quality, evaluate whether an automated feedback feature based on real-time assessment of image quality improves the overall quality of acquired wound images, and evaluate the feasibility of deploying the mHealth tool for home-based chronic wound self-monitoring by patients with SSc. METHODS We developed an mHealth tool composed of a wound imaging and management app, a custom color reference sticker, and a smartphone holder. We introduced 2 objective image quality parameters based on the sharpness and presence of the color checker to assess the quality of the image during acquisition and enable a quality feedback mechanism in an advanced version of the app. We randomly assigned patients with SSc and DU to the 2 device groups (basic and feedback) to self-document their DU at home over 8 weeks. The color checker detection ratio (CCDR) and color checker sharpness (CCS) were compared between the 2 groups. We evaluated the feasibility of the mHealth tool by analyzing the usability feedback from questionnaires, user behavior and timings, and the overall quality of the wound images. RESULTS A total of 21 patients were enrolled, of which 15 patients were included in the image quality analysis. The average CCDR was 0.96 (191/199) in the feedback group and 0.86 (158/183) in the basic group. The feedback group showed significantly higher (P<.001) CCS compared to the basic group. The usability questionnaire results showed that the majority of patients were satisfied with the tool, but could benefit from disease-specific adaptations. The median assessment duration was <50 seconds in all patients, indicating the mHealth tool was efficient to use and could be integrated into the daily routine of patients. CONCLUSIONS We developed an mHealth tool that enables patients with SSc to acquire good-quality DU images and demonstrated that it is feasible to deploy such an app in this patient group. The feedback mechanism improved the overall image quality. The introduced technical solutions consist of a further step towards reliable and trustworthy digital health for home-based self-management of wounds.

  • Physiologically driven, altitude-adaptive model for the interpretation of pediatric oxygen saturation at altitudes above 2,000 m a.s.l.

    by Laura Tüshaus, Monica Moreo, Jia Zhang, Stella Maria Hartinger, Daniel Mäusezahl, Walter Karlen

    Measuring peripheral oxygen saturation ([ ]) with pulse oximeters at the point of care is widely established. However, since [ ] is dependent on ambient atmospheric pressure, the distribution of [ ] values in populations living above 2000 m a.s.l. is largely unknown. Here, we propose and evaluate a computer model to predict [ ] values for pediatric permanent residents living between 0 and 4,000 m a.s.l. Based on a sensitivity analysis of oxygen transport parameters, we created an altitude-adaptive [ ] model that takes physiological adaptation of permanent residents into account. From this model, we derived an altitude-adaptive abnormal [ ] threshold using patient parameters from literature. We compared the obtained model and threshold against a previously proposed threshold derived statistically from data and two empirical data sets independently recorded from Peruvian children living at altitudes up to 4,100 m a.s.l. Our model followed the trends of empirical data, with the empirical data having a narrower healthy [ ] range below 2,000 m a.s.l. but the medians never differed more than 2.3% across all altitudes. Our threshold estimated abnormal [ ] in only 17 out of 5,981 (0.3%) healthy recordings, whereas the statistical threshold returned 95 (1.6%) recordings outside the healthy range. The strength of our parametrized model is that it is rooted in physiology-derived equations and enables customization. Furthermore, as it provides a reference [ ], it could assist practitioners in interpreting [ ] values for diagnosis, prognosis, and oxygen administration at higher altitudes. NEW & NOTEWORTHY Our model describes the altitude-dependent decrease of [ ] in healthy pediatric residents based on physiological equations and can be adapted based on measureable clinical parameters. The proposed altitude-specific abnormal [ ] threshold might be more appropriate than rigid guidelines for administering oxygen that currently are only available for patients at sea level. We see this as a starting point to discuss and adapt oxygen administration guidelines.


  • Open Access

    Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis

    by Jia Zhang, Laura Tüshaus, Néstor Nuño Martínez, Monica Moreo, Hector Verastegui, Stella M Hartinger, Daniel Mäusezahl, Walter Karlen

    Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.


  • Open Access

    Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis (Preprint)

    by Jia Zhang, Laura Tüshaus, Néstor Nuño Martínez, Monica Moreo, Hector Verastegui, Stella M Hartinger, Daniel Mäusezahl, Walter Karlen

    BACKGROUND Mobile health (mHealth) technologies have the potential to bring health care closer to people with otherwise limited access to adequate health care. However, physiological monitoring using mobile medical sensors is not yet widely used as adding biomedical sensors to mHealth projects inherently introduces new challenges. Thus far, no methodology exists to systematically evaluate these implementation challenges and identify the related risks. OBJECTIVE This study aimed to facilitate the implementation of mHealth initiatives with mobile physiological sensing in constrained health systems by developing a methodology to systematically evaluate potential challenges and implementation risks. METHODS We performed a quantitative analysis of physiological data obtained from a randomized household intervention trial that implemented sensor-based mHealth tools (pulse oximetry combined with a respiratory rate assessment app) to monitor health outcomes of 317 children (aged 6-36 months) that were visited weekly by 1 of 9 field workers in a rural Peruvian setting. The analysis focused on data integrity such as data completeness and signal quality. In addition, we performed a qualitative analysis of pretrial usability and semistructured posttrial interviews with a subset of app users (7 field workers and 7 health care center staff members) focusing on data integrity and reasons for loss thereof. Common themes were identified using a content analysis approach. Risk factors of each theme were detailed and then generalized and expanded into a checklist by reviewing 8 mHealth projects from the literature. An expert panel evaluated the checklist during 2 iterations until agreement between the 5 experts was achieved. RESULTS Pulse oximetry signals were recorded in 78.36% (12,098/15,439) of subject visits where tablets were used. Signal quality decreased for 1 and increased for 7 field workers over time (1 excluded). Usability issues were addressed and the workflow was improved. Users considered the app easy and logical to use. In the qualitative analysis, we constructed a thematic map with the causes of low data integrity. We sorted them into 5 main challenge categories: environment, technology, user skills, user motivation, and subject engagement. The obtained categories were translated into detailed risk factors and presented in the form of an actionable checklist to evaluate possible implementation risks. By visually inspecting the checklist, open issues and sources for potential risks can be easily identified. CONCLUSIONS We developed a data integrity–based methodology to assess the potential challenges and risks of sensor-based mHealth projects. Aiming at improving data integrity, implementers can focus on the evaluation of environment, technology, user skills, user motivation, and subject engagement challenges. We provide a checklist to assist mHealth implementers with a structured evaluation protocol when planning and preparing projects.

  • Open Access

    Physiologically driven, altitude-adaptive model for the interpretation of pediatric oxygen saturation at altitudes above 2000 m a.s.l

    by Laura Tüshaus, Monica Moreo, Jia Zhang, Stella Maria Hartinger, Daniel Mäusezahl, Walter Karlen

    Measuring peripheral oxygen saturation (SpO 2 ) with pulse oximeters at the point of care is widely established. However, since SpO 2 is dependent on ambient atmospheric pressure, the distribution of SpO 2 values in populations living above 2000 m a.s.l. is largely unknown. Here, we propose and evaluate a computer model to predict SpO 2 values for pediatric permanent residents living between 0 and 4000 m a.s.l. Based on a sensitivity analysis of oxygen transport parameters, we created an altitude-adaptive SpO 2 model that takes physiological adaptation of permanent residents into account. From this model, we derived an altitude-adaptive abnormal SpO 2 threshold using patient parameters from literature. We compared the obtained model and threshold against a previously proposed threshold derived statistically from data and two empirical datasets independently recorded from Peruvian children living at altitudes up to 4100 m a.s.l. Our model followed the trends of empirical data, with the empirical data having a narrower healthy SpO 2 range below 2000 m a.s.l., but the medians did never differ more than 2.29% across all altitudes. Our threshold estimated abnormal SpO 2 in only 17 out of 5981 (0.3%) healthy recordings, whereas the statistical threshold returned 95 (1.6%) recordings outside the healthy range. The strength of our parametrised model is that it is rooted in physiology-derived equations and enables customisation. Furthermore, as it provides a reference SpO 2 , it could assist practitioners in interpreting SpO 2 values for diagnosis, prognosis, and oxygen administration at higher altitudes. New & Noteworthy: Our model describes the altitude-dependent decrease of SpO 2 in healthy pediatric residents based on physiological equations and can be adapted based on measureable clinical parameters. The proposed altitude-specific abnormal SpO 2 threshold might be more appropriate than rigid guidelines for administering oxygen that currently are only available for sea level patients. We see this as a starting point to discuss and adapt oxygen administration guidelines.


  • Open Access

    In human non-REM sleep, more slow-wave activity leads to less blood flow in the prefrontal cortex

    by Laura Tüshaus, Ximena Omlin, Ruth O’gorman Tuura, Andrea Federspiel, Roger Luechinger, Philipp Staempfli, Thomas Koenig, Peter Achermann

    Cerebral blood flow (CBF) is related to integrated neuronal activity of the brain whereas EEG provides a more direct measurement of transient neuronal activity. Therefore, we addressed what happens in the brain during sleep, combining CBF and EEG recordings. The dynamic relationship of CBF with slow-wave activity (SWA; EEG sleep intensity marker) corroborated vigilance state specific (i.e., wake, non-rapid eye movement (NREM) sleep stages N1-N3, wake after sleep) differences of CBF e.g. in the posterior cingulate, basal ganglia, and thalamus, indicating their role in sleep-wake regulation and/or sleep processes. These newly observed dynamic correlations of CBF with SWA – namely a temporal relationship during continuous NREM sleep in individuals – additionally implicate an impact of sleep intensity on the brain’s metabolism. Furthermore, we propose that some of the aforementioned brain areas that also have been shown to be affected in disorders of consciousness might therefore contribute to the emergence of consciousness.


  • Resisting Sleep Pressure: Impact on Resting State Functional Network Connectivity

    by Laura Tüshaus, Joshua Henk Balsters, Anthony Schläpfer, Daniel Brandeis, Ruth O’gOrman Tuura, Peter Achermann

    In today’s 24/7 society, sleep restriction is a common phenomenon which leads to increased levels of sleep pressure in daily life. However, the magnitude and extent of impairment of brain functioning due to increased sleep pressure is still not completely understood. Resting state network (RSN) analyses have become increasingly popular because they allow us to investigate brain activity patterns in the absence of a specific task and to identify changes under different levels of vigilance (e.g. due to increased sleep pressure). RSNs are commonly derived from BOLD fMRI signals but studies progressively also employ cerebral blood flow (CBF) signals. To investigate the impact of sleep pressure on RSNs, we examined RSNs of participants under high (19 h awake) and normal (10 h awake) sleep pressure with three imaging modalities (arterial spin labeling, BOLD, pseudo BOLD) while providing confirmation of vigilance states in most conditions. We demonstrated that CBF and pseudo BOLD signals (measured with arterial spin labeling) are suited to derive independent component analysis based RSNs. The spatial map differences of these RSNs were rather small, suggesting a strong biological substrate underlying these networks. Interestingly, increased sleep pressure, namely longer time awake, specifically changed the functional network connectivity (FNC) between RSNs. In summary, all FNCs of the default mode network with any other network or component showed increasing effects as a function of increased ‘time awake’. All other FNCs became more anti-correlated with increased ‘time awake’. The sensorimotor networks were the only ones who showed a within network change of FNC, namely decreased connectivity as function of ‘time awake’. These specific changes of FNC could reflect both compensatory mechanisms aiming to fight sleep as well as a first reduction of consciousness while becoming drowsy. We think that the specific changes observed in functional network connectivity could imply an impairment of information transfer between the affected RSNs.


  • Open Access

    The Multidimensional Aspects of Sleep Spindles and Their Relationship to Word-Pair Memory Consolidation

    by Caroline Lustenberger, Flavia Wehrle, Laura Tüshaus, Peter Achermann, Reto Huber

    Study Objectives:. Several studies proposed a link between sleep spindles and sleep dependent memory consolidation in declarative learning tasks. In ad


  • Inter‐individual and intra‐individual variation of the effects of pulsed RF EMF exposure on the human sleep EEG

    by Caroline Lustenberger, Manuel Murbach, Laura Tüshaus, Flavia Wehrle, Niels Kuster, Peter Achermann, Reto Huber

    Pulse‐modulated radiofrequency electromagnetic fields (RF EMF) can alter brain activity during sleep; increases of electroencephalographic (EEG) power in the sleep spindle (13.75–15.25 Hz) and delta‐theta (1.25–9 Hz) frequency range have been reported. These field effects show striking inter‐individual differences. However, it is still unknown whether individual subjects react in a similar way when repeatedly exposed. Thus, our study aimed to investigate inter‐individual variation and intra‐individual stability of field effects. To do so, we exposed 20 young male subjects twice for 30 min prior to sleep to the same amplitude modulated 900 MHz (2 Hz pulse, 20 Hz Gaussian low‐pass filter and a ratio of peak‐to‐average of 4) RF EMF (spatial peak absorption of 2 W/kg averaged over 10 g) 2 weeks apart. The topographical analysis of EEG power during all‐night non‐rapid eye movement sleep revealed: (1) exposure‐related increases in delta‐theta frequency range in several fronto‐central electrodes; and (2) no differences in spindle frequency range. We did not observe reproducible within‐subject RF EMF effects on sleep spindle and delta‐theta activity in the sleep EEG and it remains unclear whether a biological trait of how the subjects' brains react to RF EMF exists. Bioelectromagnetics. 36:169–177, 2015.