IRIsaias Ramirez-Vazquez

Isaias Ramirez-Vazquez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Isaias Ramirez-Vazquez has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Alberto Brito-Luisillo

    Researcher, Transmision y Distribucion, Instituto Nacional de Electricidad y Energias Limpias, Cuernavaca, Morelos, México

    1 shared publication
  • Alberto Hernandez-Valdez

    Researcher, Transmision y Distribucion, Instituto Nacional de Electricidad y Energias Limpias, Cuernavaca, Morelos, México

    1 shared publication
  • C. Manzanares-Diaz

    Comision Federal de Electricidad, 62755, Mexico

    1 shared publication
  • David Ponce-Noyola

    Researcher, Transmision y Distribucion, Instituto Nacional de Electricidad y Energias Limpias, Cuernavaca, Morelos, México

    1 shared publication
  • E. Gaona-Estrada

    Instituto Nacional de Electricidad y Energias Limpias (INEEL), 62490, Mexico

    1 shared publication
  • G.M. Tena

    Instituto de Investigaciones Electricas (IIE), Cuernavaca, Mexico

    1 shared publication

Latest Publications

  • Open Access

    Graphene nano particles to improve lightning dissipation on transmission lines

    by I. Ramirez-Vazquez, J. E. Salgado-Talavera, E. Gaona-Estrada, S. M. Rowland, C. Manzanares-Diaz

    Lightning is the primary cause of outages for many high voltage transmission lines. One approach to reduce the frequency of these outages is the improvement of the grounding system using chemical ground enhancers to better disperse transient or fault currents into the soil. In this paper, the objective is to use graphene nano particles to improve the performance of commercial ground enhancers by exploration of 15 different commercial graphene nano particles used to reformulate 19 commercial ground enhancers and one natural ground enhancer. Incorporation of nano graphene particles is by high shear mixing method. The results show reduction in two of the commercial ground enhancers’ resistivity values by a factor of 60. Moreover, lightning impulse tests show that the use of graphene reduce deterioration of the ground enhancer, which can occur after high current events, thereby prolonging its efficacy. Due to the superior electrical conductivity and chemical stability of the graphene, the reformulated ground enhancers improve short-term performance in managing lightning current impulses, and provide a solution, which is likely to perform better over long periods. However, the compatibility of the constituent parts of the formulation is critical to long-term performance.

  • Replacing steel members with composite members on transmission towers

    by Julio C. Vergara-Vazquez, Isaias Ramirez-Vazquez, Alberto Hernandez-Valdez, Ramiro Hernandez-Corona, Alberto Brito-Luisillo, David Ponce-Noyola

    Illegal removal of redundant elements in transmission towers leads to the collapse of transmission structures under moderate winds. Hence, the removal of structural elements in transmission structures promotes economic losses for power utilities. A possible solution that can reduce extraction of steel members, and decrease power outages, is the replacement of steel redundant members with composite material elements and their connection methods. Hence, evaluation of composite redundant members as structural elements is carried out by the finite-element method to analyse the performance in a 400 kV transmission tower. The performance of the composite and steel elements is analysed by tensile and compressive strength and percentage of use under load conditions in a transmission tower. A different connection method is considered and tested to verify the structural adhesive effectiveness according to the loads determined in simulations. The connection of composite redundant members was implemented in 400 kV transmission towers.


  • Experiences on pollution level measurement in Mexico

    by Gerardo Montoya-Tena, Ramiro Hernández-Corona, Isaías Ramírez-Vázquez


  • Analysis of the Mexican lightning activity monitored by NASA satellites

    by Isaias Ramirez-Vazquez, Ramiro Hernandez-Corona, Gerardo Montoya T, Carlos Romualdo-Torres


  • Nonstandard method for accelerated ageing tests of nonceramic insulators

    by I.R. Vazquez, G.M. Tena, R.H. Corona

    A methodology for testing accelerated ageing of nonceramic insulators (NCI) is presented based mainly on polluting the insulators with several substances, such as kaolin, lime, fertilizer and natural field pollutants. The polluted insulators are evaluated inside a salt fog chamber by applying cycles of salt fog, clean fog, drying and constant voltage. During the tests, clear evidence of tracking, erosion, chalking and puncture was observed on the insulators. Flashover takes place on the early damaged insulators in a relatively short time with respect to the test time of 5000 h recommended by IEC 61109. Based on the results obtained it is necessary to modify the standard continuous 5000 h salt fog test to evaluate the long-term performance of NCI. The new test must consider low salinity, clean fog and drying periods and an initial pollution coating. Under these conditions, the leakage current magnitude is smaller and consequently much more discharge activity occurs over the polluted insulator surface leading to surface deterioration, since hydrophobicity recovery of the insulator surface is allowed during the drying period. Measurements show that the leakage current peak values were in a range from 50 to 120 mA.