KMKatsuhiko Mitsuzaki

Katsuhiko Mitsuzaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Katsuhiko Mitsuzaki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Gen Iinuma

    Department of Radiology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, Japan

    1 shared publication
  • Hideto Tomimatsu

    Department of Radiology, Gifu University School of Medicine, 1-1 Yanagito, Gifu, Gifu, Japan

    1 shared publication
  • Masatoshi Takahashi

    Division of Psychosomatic Medicine, Department of Neurology, University of Occupational and Environment Health, Kitakyushu, Japan

    1 shared publication
  • Mototaka Miyake

    Department of Radiology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, Japan

    1 shared publication
  • T Namimoto

    University Hospital

    1 shared publication
  • Tsuyoshi Morimoto

    Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa, Japan

    1 shared publication

Latest Publications

  • Computed tomographic colonography with a reduced dose of laxative using a novel barium sulfate contrast agent in Japan

    by Katsuhiko Mitsuzaki, Gen Iinuma, Tsuyoshi Morimoto, Mototaka Miyake, Hideto Tomimatsu

    To test the tagging efficacy, patient acceptability, and accuracy of computed tomographic colonography (CTC) with a reduced dose of laxative using a novel barium sulfate (BaSO4) contrast agent.


  • MR imaging of the liver: comparison between single-shot echo-planar and half-Fourier rapid acquisition with relaxation enhancement sequences.

    by Y Yamashita, Y Tang, T Namimoto, K Mitsuzaki, M Takahashi

    To evaluate single-shot T2-weighted magnetic resonance sequences and their role in clinical practice in patients with hepatic lesions. Prospective comparison of echo-planar and half-Fourier rapid acquisition with relaxation enhancement (RARE) imaging was performed in 80 patients with focal hepatic lesions. Spin-echo (SE) single-shot echo-planar (echo times, 47 and 80 msec) and half-Fourier RARE (echo time, 59 msec) images were compared with turbo SE (repetition time msec/echo time msec = 3,200-7,600/90) images. Quantitative, qualitative, and receiver operating characteristic (ROC) analyses were performed. For liver, signal-to-noise ratios on half-Fourier RARE images were significantly higher than those on echo-planar images (P < .01). For cystic lesions, contrast on half-Fourier RARE and echo-planar images was slightly higher than that on turbo SE images. For solid lesions, contrast on echo-planar images was better than that on half-Fourier RARE or turbo SE images. Artifacts including ghosting, bowel motion, susceptibility difference, and chemical shift were negligible on half-Fourier RARE images in all patients, whereas susceptibility difference and chemical shift of various degrees were seen on all echo-planar images. On the basis of ROC analyses, tumor detection rates were significantly higher with half-Fourier RARE and turbo SE images than with echo-planar images (P < .01). Echo-planar images provide sufficient contrast to allow detection of both solid and cystic masses, but severe artifacts preclude routine use. Half-Fourier RARE images are free from artifacts (chemical shift and susceptibility) and diagnostic performance with them is similar to that with turbo SE images.