Kang Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kang Chen has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Takasuke Irie
Microsonic Company Ltd., Tokyo, Japan
8 shared publicationsTakeshi Morita
Graduate School of Frontier Sciences, The University of Tokyo, Chiba, Japan
8 shared publications- Jianming Wen
College of Mathematical Medicine, Zhejiang Normal University, Jinhua, China
5 shared publications - Takashi Iijima
National Institute of Advanced Industrial Science and Technology
5 shared publications Jijie Ma
Institute of Precision Machinery and Smart Structure, College of Engineering, Zhejiang Normal University, Jinhua, P.R. China
4 shared publicationsJianming Wen
3 shared publications
Latest Publications
- Open Access
- 19 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (25) , eaed2114
Synchronous wearable ultrasound for early detection of coronary and carotid artery comorbidity
Coronary heart disease (CHD) and carotid artery disease (CAD) often co-occur. However, conventional diagnosis typically involves separate, site-by-site examinations after symptoms appear, leading to delayed intervention. In this work, we developed a wearable ultrasound system that enables synchronous monitoring of cardiac and carotid dynamics for comorbidity assessment. The system combines dual wearable ultrasound patches, a synchronous imaging strategy, artificial intelligence–based image processing algorithms, and human circuitry models to automatically extract and analyze key cardiac-carotid metrics, such as heart rate, pulse rate, cardiac volume, cardiac output, and carotid blood pressure. By evaluating the correlation of these metrics between modeling and measurements, we showed the feasibility of differentiating among healthy participants and patients with CAD, CHD, or CAD-CHD comorbidity. This integrated approach constitutes a promising framework for supporting the proactive assessment of coronary-carotid comorbidity.
- 19 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (25) , eaed2114
Open AccessSynchronous wearable ultrasound for early detection of coronary and carotid artery comorbidity
Coronary heart disease (CHD) and carotid artery disease (CAD) often co-occur. However, conventional diagnosis typically involves separate, site-by-site examinations after symptoms appear, leading to delayed intervention. In this work, we developed a wearable ultrasound system that enables synchronous monitoring of cardiac and carotid dynamics for comorbidity assessment. The system combines dual wearable ultrasound patches, a synchronous imaging strategy, artificial intelligence–based image processing algorithms, and human circuitry models to automatically extract and analyze key cardiac-carotid metrics, such as heart rate, pulse rate, cardiac volume, cardiac output, and carotid blood pressure. By evaluating the correlation of these metrics between modeling and measurements, we showed the feasibility of differentiating among healthy participants and patients with CAD, CHD, or CAD-CHD comorbidity. This integrated approach constitutes a promising framework for supporting the proactive assessment of coronary-carotid comorbidity.
- 3 February 2026
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 168
Curvature effects on wearable ultrasound image quality and generalized deep learning correction methods
- 3 February 2026
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 168
Curvature effects on wearable ultrasound image quality and generalized deep learning correction methods
- 12 June 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (12) , 12TR02
Current status and challenges of minimally invasive ultrasound thermal ablation technology
Image-guided minimally invasive ultrasound thermal ablation has been widely studied for disease treatment due to its unique advantages, such as large treatment volumes and conformal delivery of ablation energy. This review presents the state-of-the-art of this technology and highlights the challenges. Ultrasound applicator designs, common image guidance methods, and treatment sites are first summarized. The recent decade has shown that despite the continuous development of this technology, only limited clinical translations have succeeded. To push this technology forward, challenges regarding the advancement of applicators, precise and real-time imaging guidance methods, and the validation of the clinical effectiveness of potential treatment sites are described. Finally, future directions are discussed. It is envisioned that future development of artificial intelligence-powered applicators with conformal ablation ability and multi-modal image guidance will enable surgeons to perform precise, visible, customizable treatment.
- 12 June 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (12) , 12TR02
Current status and challenges of minimally invasive ultrasound thermal ablation technology
Image-guided minimally invasive ultrasound thermal ablation has been widely studied for disease treatment due to its unique advantages, such as large treatment volumes and conformal delivery of ablation energy. This review presents the state-of-the-art of this technology and highlights the challenges. Ultrasound applicator designs, common image guidance methods, and treatment sites are first summarized. The recent decade has shown that despite the continuous development of this technology, only limited clinical translations have succeeded. To push this technology forward, challenges regarding the advancement of applicators, precise and real-time imaging guidance methods, and the validation of the clinical effectiveness of potential treatment sites are described. Finally, future directions are discussed. It is envisioned that future development of artificial intelligence-powered applicators with conformal ablation ability and multi-modal image guidance will enable surgeons to perform precise, visible, customizable treatment.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2432-2441
Asymmetric-Backed Multi-Frequency Ultrasonic Transducer for Conformal Tumor Ablation
Objective: Minimally invasive ultrasound ablation transducers have been widely studied. However, conventional designs are limited by the single working frequency, restricting their conformal ablation ability (i.e., ablation size and shape controllability). Methods: New multi-frequency ultrasonic transducer design method is proposed based on the asymmetric backing layer, which divides the transducer into non-backing-layer region (i.e., front-piezoelectric region) and backing-layer region (i.e., front-piezoelectric-backing region) with multiple local thickness mode resonant frequencies. Ablation zone can be controlled by exciting the local resonance within or between the regions, and its control flexibility is further enhanced by driven under a frequency modulation signal. Experiments and calculations are combined for verifying the proposal. Results: The fabricated transducer with a Y-direction asymmetric backing layer shows five resonances, with two in each region and one resonance excited in both regions. Spatial ultrasound emission is demonstrated by acoustic measurements. Tissue ablation experiments verified spatial ablation zone control, and frequency modulation driving method enables the spatial transition of ablation zone from one region to the other, generating different ablation sizes and shapes. Finally, patient-specific simulations verified the effectiveness of conformal ablation. Conclusion: The proposed transducer enables flexible control of ablation zone. Significance: This study demonstrates a new method for conformal tumor ablation.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2432-2441
Asymmetric-Backed Multi-Frequency Ultrasonic Transducer for Conformal Tumor Ablation
Objective: Minimally invasive ultrasound ablation transducers have been widely studied. However, conventional designs are limited by the single working frequency, restricting their conformal ablation ability (i.e., ablation size and shape controllability). Methods: New multi-frequency ultrasonic transducer design method is proposed based on the asymmetric backing layer, which divides the transducer into non-backing-layer region (i.e., front-piezoelectric region) and backing-layer region (i.e., front-piezoelectric-backing region) with multiple local thickness mode resonant frequencies. Ablation zone can be controlled by exciting the local resonance within or between the regions, and its control flexibility is further enhanced by driven under a frequency modulation signal. Experiments and calculations are combined for verifying the proposal. Results: The fabricated transducer with a Y-direction asymmetric backing layer shows five resonances, with two in each region and one resonance excited in both regions. Spatial ultrasound emission is demonstrated by acoustic measurements. Tissue ablation experiments verified spatial ablation zone control, and frequency modulation driving method enables the spatial transition of ablation zone from one region to the other, generating different ablation sizes and shapes. Finally, patient-specific simulations verified the effectiveness of conformal ablation. Conclusion: The proposed transducer enables flexible control of ablation zone. Significance: This study demonstrates a new method for conformal tumor ablation.
- Open Access
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 113678-113689
Low-Loss Ultrasound Transmission Through Waveguide From Double Parabolic Reflectors (DPLUS) for Thermal Ablation
In this paper, to advance acoustic waveguide transducers towards practical thermal ablation applications, we studied DPLUS (double parabolic reflectors wave-guided ultrasonic transducer) with a 1-m long (0.6-mm radius) and low-loss fused quartz thin waveguide working at the optimal frequency of 2.2 MHz, and the thermal effects to the tissue under different ultrasound exposure time. The measured vibration attenuation coefficient of the fused quartz thin waveguide is ~0.0123 dB/MHz/cm, and such low-loss characteristic is one of the keys of the studied DPLUS for realizing thermal ablation. Under the transmitted axial vibration velocity amplitude v max at the thin waveguide tip of 1 m/s and the ultrasound exposure time of 1 s, 5 s, 10 s, 20 s, the measured temperature rises in the chicken breast tissue showed good agreements with the simulation results. Lesions were observed in the tissue under the exposure of 10 s, 20 s, and 30 s. The lesion size increases with the exposure time but the measured axial and lateral widths of the lesions were smaller than 2 mm. The presented results in this paper showed that for the first time thermal ablation was achieved by a long thin-waveguide DPLUS which becomes an important progress of DPLUS towards practical MIT applications.
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 113678-113689
Open AccessLow-Loss Ultrasound Transmission Through Waveguide From Double Parabolic Reflectors (DPLUS) for Thermal Ablation
In this paper, to advance acoustic waveguide transducers towards practical thermal ablation applications, we studied DPLUS (double parabolic reflectors wave-guided ultrasonic transducer) with a 1-m long (0.6-mm radius) and low-loss fused quartz thin waveguide working at the optimal frequency of 2.2 MHz, and the thermal effects to the tissue under different ultrasound exposure time. The measured vibration attenuation coefficient of the fused quartz thin waveguide is ~0.0123 dB/MHz/cm, and such low-loss characteristic is one of the keys of the studied DPLUS for realizing thermal ablation. Under the transmitted axial vibration velocity amplitude v max at the thin waveguide tip of 1 m/s and the ultrasound exposure time of 1 s, 5 s, 10 s, 20 s, the measured temperature rises in the chicken breast tissue showed good agreements with the simulation results. Lesions were observed in the tissue under the exposure of 10 s, 20 s, and 30 s. The lesion size increases with the exposure time but the measured axial and lateral widths of the lesions were smaller than 2 mm. The presented results in this paper showed that for the first time thermal ablation was achieved by a long thin-waveguide DPLUS which becomes an important progress of DPLUS towards practical MIT applications.
- 8 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 553-564
Optimization of the Thin Waveguide for Double-Parabolic-Reflectors Ultrasonic Transducers (DPLUS) for Thermal Ablation
Objective: Interstitial and intracavitary ultra- sound applicators had been developed and studied for minimally invasive treatments (MIT). However, the acoustic outputs are limited by the small-size PZT. We therefore studied the acoustic waveguide (AW) applicator which enables the use of a large-size PZT, and we aimed to advance AW applicators towards thermal ablation applications. Methods: Double parabolic reflectors wave-guided ultrasonic transducer (DPLUS) was introduced which has two parabolic reflectors for enhancing the acoustic output. Theoretical modeling was conducted for optimizing the DPLUS thin waveguide. Results: Modeling results showed that optimal ${\boldsymbol{a}}/{\boldsymbol{\Lambda}}$ (thin waveguide radius/wavelength) can be found and the optimal ${\boldsymbol{a}}$ depends on the excitable vibration amplitude in the thin waveguide. A local optimal ${\boldsymbol{a}}/{\boldsymbol{\Lambda}}$ = 0.2392 was considered the best choice, which results in the optimal frequency of 2.2 MHz at the radius ${\boldsymbol{a}}$ of 0.6 mm. To verify this optimal frequency, experiments under two working frequencies of 1.0282 MHz and 2.2579 MHz were conducted. Temperature rise curves in the chicken breast tissue showed good agreements between experiments and modeling results, which proved the effectiveness of the modeling. In addition, experiments showed an ablated area with a diameter of 1.03±0.12 mm under continuous excitation of 2.2579 MHz and 5 s. Con clusion: The developed DPLUS advanced the AW applicators towards thermal ablation applications. Significance: This study provides the evidence for recognizing AW applicators as a technique for thermal ablation.
- 8 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 553-564
Optimization of the Thin Waveguide for Double-Parabolic-Reflectors Ultrasonic Transducers (DPLUS) for Thermal Ablation
Objective: Interstitial and intracavitary ultra- sound applicators had been developed and studied for minimally invasive treatments (MIT). However, the acoustic outputs are limited by the small-size PZT. We therefore studied the acoustic waveguide (AW) applicator which enables the use of a large-size PZT, and we aimed to advance AW applicators towards thermal ablation applications. Methods: Double parabolic reflectors wave-guided ultrasonic transducer (DPLUS) was introduced which has two parabolic reflectors for enhancing the acoustic output. Theoretical modeling was conducted for optimizing the DPLUS thin waveguide. Results: Modeling results showed that optimal ${\boldsymbol{a}}/{\boldsymbol{\Lambda}}$ (thin waveguide radius/wavelength) can be found and the optimal ${\boldsymbol{a}}$ depends on the excitable vibration amplitude in the thin waveguide. A local optimal ${\boldsymbol{a}}/{\boldsymbol{\Lambda}}$ = 0.2392 was considered the best choice, which results in the optimal frequency of 2.2 MHz at the radius ${\boldsymbol{a}}$ of 0.6 mm. To verify this optimal frequency, experiments under two working frequencies of 1.0282 MHz and 2.2579 MHz were conducted. Temperature rise curves in the chicken breast tissue showed good agreements between experiments and modeling results, which proved the effectiveness of the modeling. In addition, experiments showed an ablated area with a diameter of 1.03±0.12 mm under continuous excitation of 2.2579 MHz and 5 s. Con clusion: The developed DPLUS advanced the AW applicators towards thermal ablation applications. Significance: This study provides the evidence for recognizing AW applicators as a technique for thermal ablation.
- Open Access
- 3 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 26117-26126
Hard-Type Piezoelectric Materials Based Double-Parabolic-Reflectors Ultrasonic Transducer (DPLUS) for High-Power Ultrasound
To achieve wide-frequency (20 kHz-2 MHz) high-power output (10 MPa) of Double Parabolic refLectors wave-guided Ultrasonic tranSducers (DPLUS), this paper investigated the DPLUS with hard-type PZTs. Under resonant excitation of the DPLUS waveguide, around 30 harmonic longitudinal modes from the thin waveguide (1 mm in diameter and 40 mm long) can be excited between 20 kHz to 2 MHz. From 20 kHz to 0.4 MHz, the maximum peak vibration velocity was 7.5 m/s; from 1 MHz to 2 MHz, the maximum peak vibration velocity of hard-type PZT DPLUS (7 m/s) was 3.5 times of soft-type piezoelectric materials DPLUS (2 m/s). Acoustic evaluation revealed large acoustic pressure at a wide frequency range: 0.46 MPa (at 31 kHz), 10 MPa (at 590 kHz), 7.7 MPa (at 1.154 MHz), and 7.2 MPa (at 1.322 MHz). Results proved wide-frequency and high-power operation of DPLUS, which are significant for realizing various applications.
- 3 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 26117-26126
Open AccessHard-Type Piezoelectric Materials Based Double-Parabolic-Reflectors Ultrasonic Transducer (DPLUS) for High-Power Ultrasound
To achieve wide-frequency (20 kHz-2 MHz) high-power output (10 MPa) of Double Parabolic refLectors wave-guided Ultrasonic tranSducers (DPLUS), this paper investigated the DPLUS with hard-type PZTs. Under resonant excitation of the DPLUS waveguide, around 30 harmonic longitudinal modes from the thin waveguide (1 mm in diameter and 40 mm long) can be excited between 20 kHz to 2 MHz. From 20 kHz to 0.4 MHz, the maximum peak vibration velocity was 7.5 m/s; from 1 MHz to 2 MHz, the maximum peak vibration velocity of hard-type PZT DPLUS (7 m/s) was 3.5 times of soft-type piezoelectric materials DPLUS (2 m/s). Acoustic evaluation revealed large acoustic pressure at a wide frequency range: 0.46 MPa (at 31 kHz), 10 MPa (at 590 kHz), 7.7 MPa (at 1.154 MHz), and 7.2 MPa (at 1.322 MHz). Results proved wide-frequency and high-power operation of DPLUS, which are significant for realizing various applications.
- 1 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 181-186
High-Power Ultrasonic Transducer for Effective Hemolysis
To realize compact and portable hemolysis devices, an ultrasonic transducer with a blood channel is proposed in this study. Ultrasound waves are focused by a parabolic reflector to generate high sound pressure inside the channel for hemolysis. The hemolysis performance of the transducer is evaluated using simulations and experiments. Experiments are performed with various voltages and flow rates to verify the feasibility of hemolysis. The hemolysis rate is more than 93% at an applied voltage of 80 Vp-p, a flow rate of 0.25 mL/min, and a driving frequency of 1.28 MHz.
- 1 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 181-186
High-Power Ultrasonic Transducer for Effective Hemolysis
To realize compact and portable hemolysis devices, an ultrasonic transducer with a blood channel is proposed in this study. Ultrasound waves are focused by a parabolic reflector to generate high sound pressure inside the channel for hemolysis. The hemolysis performance of the transducer is evaluated using simulations and experiments. Experiments are performed with various voltages and flow rates to verify the feasibility of hemolysis. The hemolysis rate is more than 93% at an applied voltage of 80 Vp-p, a flow rate of 0.25 mL/min, and a driving frequency of 1.28 MHz.
- 15 September 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 60 (10) , 106504
Selection criteria of piezoelectric materials for double-parabolic-reflectors ultrasonic transducers (DPLUS) for high-power ultrasound
To suit double parabolic reflectors wave-guided ultrasonic transducer (DPLUS) for high-power ultrasound applications, we investigated the selection criteria of piezoelectric materials for DPLUS. Four piezoelectric materials were prepared: two lead–zirconate–titanate (PZT) types and two lead-free types. For non-resonant excitation of the DPLUS waveguide, the piezoelectric constant e and the thickness of piezoelectric materials are two important evaluation indexes. PZT 5H was found as the best candidate. For resonant excitation of the DPLUS waveguide, two situations should be distinguished. For low-frequency modes excitation, the discussed modes matching issue is essential. For high-frequency modes excitation, high-power properties of the piezoelectric material are important for improving the vibration output of DPLUS; LFP 0202 was found as the best candidate. Low-frequency modes can achieve 8 m s −1 of maximum peak vibration velocity, but high-frequency modes were smaller than 2 m s −1 . Results are important to design the DPLUS for various high-power ultrasound applications.
- 15 September 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 60 (10) , 106504
Selection criteria of piezoelectric materials for double-parabolic-reflectors ultrasonic transducers (DPLUS) for high-power ultrasound
To suit double parabolic reflectors wave-guided ultrasonic transducer (DPLUS) for high-power ultrasound applications, we investigated the selection criteria of piezoelectric materials for DPLUS. Four piezoelectric materials were prepared: two lead–zirconate–titanate (PZT) types and two lead-free types. For non-resonant excitation of the DPLUS waveguide, the piezoelectric constant e and the thickness of piezoelectric materials are two important evaluation indexes. PZT 5H was found as the best candidate. For resonant excitation of the DPLUS waveguide, two situations should be distinguished. For low-frequency modes excitation, the discussed modes matching issue is essential. For high-frequency modes excitation, high-power properties of the piezoelectric material are important for improving the vibration output of DPLUS; LFP 0202 was found as the best candidate. Low-frequency modes can achieve 8 m s −1 of maximum peak vibration velocity, but high-frequency modes were smaller than 2 m s −1 . Results are important to design the DPLUS for various high-power ultrasound applications.
- 4 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (10) , 2965-2973
Double-Parabolic-Reflectors Ultrasonic Transducer With Flexible Waveguide for Minimally Invasive Treatment
Objective: To treat tissues that are difficult to access, ultrasound based minimally invasive treatment (MIT) is promising. However, high-power ultrasound delivery through waveguides had been difficult which can increase treatment duration. It is our effort to design the waveguide that can transmit powerful ultrasound. Methods: The waveguide with two parabolic reflectors was proposed by us to produce high-energy-density plane wave. Use of flexible and long thin waveguide was demonstrated here. Results: Double Parabolic refLectors wave-guided high-power Ultrasonic tranSducer (DPLUS) including a φ1 mm ×1 m Nitinol thin waveguide was fabricated. It was shown that high-power ultrasound between 1 to 2 MHz can be propagated through the thin waveguide. Low-loss waveguide material was confirmed to be important to enhance output. As ultrasound is transmitted into working medium, energy mainly flows from the side surface. Temperature of target soft tissue was demonstrated to drastically increase by 10 degree in 30 seconds. Conclusion: The developed DPLUS makes high-power ultrasound transmission in long and flexible thin waveguide possible. Significance: The concept of DPLUS for delivering high-power ultrasound is powerful in the field of Ultrasonics.
- 4 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (10) , 2965-2973
Double-Parabolic-Reflectors Ultrasonic Transducer With Flexible Waveguide for Minimally Invasive Treatment
Objective: To treat tissues that are difficult to access, ultrasound based minimally invasive treatment (MIT) is promising. However, high-power ultrasound delivery through waveguides had been difficult which can increase treatment duration. It is our effort to design the waveguide that can transmit powerful ultrasound. Methods: The waveguide with two parabolic reflectors was proposed by us to produce high-energy-density plane wave. Use of flexible and long thin waveguide was demonstrated here. Results: Double Parabolic refLectors wave-guided high-power Ultrasonic tranSducer (DPLUS) including a φ1 mm ×1 m Nitinol thin waveguide was fabricated. It was shown that high-power ultrasound between 1 to 2 MHz can be propagated through the thin waveguide. Low-loss waveguide material was confirmed to be important to enhance output. As ultrasound is transmitted into working medium, energy mainly flows from the side surface. Temperature of target soft tissue was demonstrated to drastically increase by 10 degree in 30 seconds. Conclusion: The developed DPLUS makes high-power ultrasound transmission in long and flexible thin waveguide possible. Significance: The concept of DPLUS for delivering high-power ultrasound is powerful in the field of Ultrasonics.