Huilu Bao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Huilu Bao has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jianming Wen
College of Mathematical Medicine, Zhejiang Normal University, Jinhua, China
4 shared publications - Jinglei Ping
Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
4 shared publications - Xiao Fan
Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
4 shared publications - Xiaoyu Zhang
Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst 1 , Amherst, Massachusetts 01003
3 shared publications - Jianping Li
The Institute of Precision Machinery and Smart Structure, College of Engineering, Zhejiang Normal University, Jinhua 321004, China
2 shared publications Jijie Ma
Institute of Precision Machinery and Smart Structure, College of Engineering, Zhejiang Normal University, Jinhua, P.R. China
2 shared publications
Latest Publications
- 27 August 2026
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 3 (10) , 663-679
Engineering two-dimensional electronic biosensors
- 27 August 2026
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 3 (10) , 663-679
Engineering two-dimensional electronic biosensors
- 26 November 2024
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 24 (49) , 15645-15651
Spatiotemporal Cell Control via High-Precision Electronic Regulation of Microenvironmental pH
Accurate regulation of extracellular pH is crucial for controlling cell behaviors and functions. However, typical methods, which primarily rely on replacing cell culture media or using ionic diffusion, are slow, nondirectional, and lack spatiotemporal resolution. Here, we develop a microfabricated device that regulates microenvironmental pH within specific localized zones with high precision (uncertainty <0.1 pH units) and temporal resolution. The device uses a synchronization strategy that coordinates two processes: pulsatile modulation of pH through microelectrolysis and ultrasensitive graphene-electronic pH sensing, which operates in antiphase to the modulation. Using this device, we show real-time control of the dynamic behaviors of microscale clusters of bacteria (motility) and cardiomyocytes (calcium signaling and necrotic injury) in response to precisely regulated extracellular pH variations. Our device addresses the limitations of typical pH-altering techniques and holds significant potential to advance cell biology, physiology, tissue engineering, and regenerative medicine.
- 26 November 2024
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 24 (49) , 15645-15651
Spatiotemporal Cell Control via High-Precision Electronic Regulation of Microenvironmental pH
Accurate regulation of extracellular pH is crucial for controlling cell behaviors and functions. However, typical methods, which primarily rely on replacing cell culture media or using ionic diffusion, are slow, nondirectional, and lack spatiotemporal resolution. Here, we develop a microfabricated device that regulates microenvironmental pH within specific localized zones with high precision (uncertainty <0.1 pH units) and temporal resolution. The device uses a synchronization strategy that coordinates two processes: pulsatile modulation of pH through microelectrolysis and ultrasensitive graphene-electronic pH sensing, which operates in antiphase to the modulation. Using this device, we show real-time control of the dynamic behaviors of microscale clusters of bacteria (motility) and cardiomyocytes (calcium signaling and necrotic injury) in response to precisely regulated extracellular pH variations. Our device addresses the limitations of typical pH-altering techniques and holds significant potential to advance cell biology, physiology, tissue engineering, and regenerative medicine.
- 14 October 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (16) , 164105
Neural network–enabled, all-electronic control of non-Newtonian fluid flow
Real-time, all-electronic control of non-Newtonian fluid flow through a microscale channel is crucial for various applications in manufacturing and healthcare. However, existing methods lack the sensitivity required for accurate measurement and the real-time responsiveness necessary for effective adjustment. Here, we demonstrate an all-electronic system that enables closed-loop, real-time, high-sensitivity control of various waveforms of non-Newtonian fluid flow (0.76 μl min−1) through a micro-sized outlet. Our approach combines a contactless, cuff-like flow sensor with a neural-network control program. This system offers a simple, miniaturized, versatile, yet high-performance solution for non-Newtonian fluid flow control, easily integrated into existing setups.
- 14 October 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (16) , 164105
Neural network–enabled, all-electronic control of non-Newtonian fluid flow
Real-time, all-electronic control of non-Newtonian fluid flow through a microscale channel is crucial for various applications in manufacturing and healthcare. However, existing methods lack the sensitivity required for accurate measurement and the real-time responsiveness necessary for effective adjustment. Here, we demonstrate an all-electronic system that enables closed-loop, real-time, high-sensitivity control of various waveforms of non-Newtonian fluid flow (0.76 μl min−1) through a micro-sized outlet. Our approach combines a contactless, cuff-like flow sensor with a neural-network control program. This system offers a simple, miniaturized, versatile, yet high-performance solution for non-Newtonian fluid flow control, easily integrated into existing setups.
- 4 March 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (10) , 103701
On-chip microscale isoelectric focusing enhances protein detection limit
Enhancing the detection limit in protein analysis is essential for a wide range of biomedical applications. In typical fluorescent protein assays, this limit is constrained by the detection capacity of the photon detector. Here, we develop an approach that significantly enhances the protein detection threshold by using microscale isoelectric focusing implemented directly at the detection site on a protein sensor chip. We demonstrate that by electrically generating a localized pH environment within a radius of ∼60 μm, protein molecules can be concentrated within this range and be detected at levels over four times lower than those achieved by measurements without on-chip isoelectric focusing. We find that this detection-limit enhancement results from a dual effect: the concentrating of the protein molecules and a reduction in the diffusion-induced fluctuation. Our approach offers a simple, yet highly effective ultra-low-power all-electronic solution for substantially improving protein analysis detection limits for diverse applications, including healthcare, clinical diagnostics, and therapeutics.
- 4 March 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (10) , 103701
On-chip microscale isoelectric focusing enhances protein detection limit
Enhancing the detection limit in protein analysis is essential for a wide range of biomedical applications. In typical fluorescent protein assays, this limit is constrained by the detection capacity of the photon detector. Here, we develop an approach that significantly enhances the protein detection threshold by using microscale isoelectric focusing implemented directly at the detection site on a protein sensor chip. We demonstrate that by electrically generating a localized pH environment within a radius of ∼60 μm, protein molecules can be concentrated within this range and be detected at levels over four times lower than those achieved by measurements without on-chip isoelectric focusing. We find that this detection-limit enhancement results from a dual effect: the concentrating of the protein molecules and a reduction in the diffusion-induced fluctuation. Our approach offers a simple, yet highly effective ultra-low-power all-electronic solution for substantially improving protein analysis detection limits for diverse applications, including healthcare, clinical diagnostics, and therapeutics.
- 24 January 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (4) , 044102
Electrical contactless microfluidic flow quantification
Precise sensing of microfluidic flow is essential to advancing lab-on-a-chip development and the downstream medical applications. Contactless microfluidic flow interrogation is noninvasive, nonperturbative, and fouling-free. However, known real non-contact flow sensing technologies are limited to quantifying bulk fluids. Here, we develop an electrical approach to contactless quantification of aqueous microfluidic flow. We found that the electric potential generated by the ubiquitous contact electrification of a microfluidic flow with fluidic channel walls is interrogatable by using a probe electrode at a distance over centimeters from the microfluidic flow, and the measured voltage response demonstrates linear relationship to the microfluidic flow rate with a resolution of sub-microliter per minute (in a 1-Hz bandwidth), providing an ideal, high-precision contactless flow transduction pathway. In addition to this primary finding, by using a monolayer-graphene coated probe electrode, in comparison with a typical bare probe electrode, an overall enhancement in flow-sensory resolution of 36.4% is attained.
- 24 January 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (4) , 044102
Electrical contactless microfluidic flow quantification
Precise sensing of microfluidic flow is essential to advancing lab-on-a-chip development and the downstream medical applications. Contactless microfluidic flow interrogation is noninvasive, nonperturbative, and fouling-free. However, known real non-contact flow sensing technologies are limited to quantifying bulk fluids. Here, we develop an electrical approach to contactless quantification of aqueous microfluidic flow. We found that the electric potential generated by the ubiquitous contact electrification of a microfluidic flow with fluidic channel walls is interrogatable by using a probe electrode at a distance over centimeters from the microfluidic flow, and the measured voltage response demonstrates linear relationship to the microfluidic flow rate with a resolution of sub-microliter per minute (in a 1-Hz bandwidth), providing an ideal, high-precision contactless flow transduction pathway. In addition to this primary finding, by using a monolayer-graphene coated probe electrode, in comparison with a typical bare probe electrode, an overall enhancement in flow-sensory resolution of 36.4% is attained.
- Open Access
Quantitative Evaluation of Burn Injuries Based on Electrical Impedance Spectroscopy of Blood with a Seven-Parameter Equivalent Circuit
A quantitative and rapid burn injury detection method has been proposed based on the electrical impedance spectroscopy (EIS) of blood with a seven-parameter equivalent circuit. The degree of burn injury is estimated from the electrical impedance characteristics of blood with different volume proportions of red blood cells (RBCs) and heated red blood cells (HRBCs). A quantitative relationship between the volume portion HHCT of HRBCs and the electrical impedance characteristics of blood has been demonstrated. A seven -parameter equivalent circuit is employed to quantify the relationship from the perspective of electricity. Additionally, the traditional Hanai equation has been modified to verify the experimental results. Results show that the imaginary part of impedance ZImt under the characteristic frequency (fc) has a linear relationship with HHCT which could be described by ZImt = −2.56HHCT − 2.01 with a correlation coefficient of 0.96. Moreover, the relationship between the plasma resistance Rp and HHCT is obtained as Rp = −7.2HHCT + 3.91 with a correlation coefficient of 0.96 from the seven -parameter equivalent circuit. This study shows the feasibility of EIS in the quantitative detection of burn injury by the quantitative parameters ZImt and Rp, which might be meaningful for the follow-up clinical treatment for burn injury.
Open AccessQuantitative Evaluation of Burn Injuries Based on Electrical Impedance Spectroscopy of Blood with a Seven-Parameter Equivalent Circuit
A quantitative and rapid burn injury detection method has been proposed based on the electrical impedance spectroscopy (EIS) of blood with a seven-parameter equivalent circuit. The degree of burn injury is estimated from the electrical impedance characteristics of blood with different volume proportions of red blood cells (RBCs) and heated red blood cells (HRBCs). A quantitative relationship between the volume portion HHCT of HRBCs and the electrical impedance characteristics of blood has been demonstrated. A seven -parameter equivalent circuit is employed to quantify the relationship from the perspective of electricity. Additionally, the traditional Hanai equation has been modified to verify the experimental results. Results show that the imaginary part of impedance ZImt under the characteristic frequency (fc) has a linear relationship with HHCT which could be described by ZImt = −2.56HHCT − 2.01 with a correlation coefficient of 0.96. Moreover, the relationship between the plasma resistance Rp and HHCT is obtained as Rp = −7.2HHCT + 3.91 with a correlation coefficient of 0.96 from the seven -parameter equivalent circuit. This study shows the feasibility of EIS in the quantitative detection of burn injury by the quantitative parameters ZImt and Rp, which might be meaningful for the follow-up clinical treatment for burn injury.
- 9 October 2019
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 28 (11) , 115020
A linear inertial piezoelectric actuator using a single bimorph vibrator
A linear inertial piezoelectric actuator using a single bimorph vibrator clamped by asymmetrical fixed beam structure is proposed in this paper to achieve extremely simple structure and high stability. It adopted one vibrator to produce the inertial impact force, which is beneficial to simplify the overall architecture. A dynamic model, based on the stiffness-damping vibration model and LuGre friction model, is established to predict the motion of the actuator by Matlab/Simulink. An experimental system is built to test its performance. Experimental results indicate that the stable minimum displacement is 1.9 μ m and the maximum repeat error rate reaches 1.1% under a square wave signal of 15 V, 2 Hz with no-load. When the load is 420 g, the minimum displacement is 0.6 μ m under 100 V and 2 Hz. Compared with similar actuators, the proposed actuator achieves much higher stable linear motion with a larger stroke and without drawback.
- 9 October 2019
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 28 (11) , 115020
A linear inertial piezoelectric actuator using a single bimorph vibrator
A linear inertial piezoelectric actuator using a single bimorph vibrator clamped by asymmetrical fixed beam structure is proposed in this paper to achieve extremely simple structure and high stability. It adopted one vibrator to produce the inertial impact force, which is beneficial to simplify the overall architecture. A dynamic model, based on the stiffness-damping vibration model and LuGre friction model, is established to predict the motion of the actuator by Matlab/Simulink. An experimental system is built to test its performance. Experimental results indicate that the stable minimum displacement is 1.9 μ m and the maximum repeat error rate reaches 1.1% under a square wave signal of 15 V, 2 Hz with no-load. When the load is 420 g, the minimum displacement is 0.6 μ m under 100 V and 2 Hz. Compared with similar actuators, the proposed actuator achieves much higher stable linear motion with a larger stroke and without drawback.
- 10 June 2019
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 30 (14) , 2099-2111
An inertial piezoelectric hybrid actuator with large angular velocity and high resolution
This article proposes an inertial piezoelectric actuator with hybrid design of asymmetrically clamping structures and a bias unit for the achievement of large angular velocity and high resolution. To investigate the influence of asymmetrical clamp and bias unit on the driving performance, two types of actuators were fabricated and tested. Combined effects from asymmetrical clamp and bias unit contribute to type A, while their subtractive effect is applied to type B. Using a scanning laser vibrometer, experiments were conducted to analyze the characteristics of the angular displacement and corresponding velocity. It is indicated that the measured first-order natural frequencies for above two types are 13.828 and 14.141 Hz, which agrees well with the simulation results of 16.666 and 17.379 Hz, respectively. Besides, compared with the actuators with simple asymmetrical clamping structure or bias unit, this hybrid actuator can obtain an angular velocity 6.87 rad/s at 80 V and 16 Hz and a resolution of 2.80 μrad under a square signal of 20 V and 1 Hz and an offset distance of −22 mm. As a result, the proposed actuators can achieve large angular velocity and high resolution, which is potentially applicable to quick positioning with high accuracy.
- 10 June 2019
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 30 (14) , 2099-2111
An inertial piezoelectric hybrid actuator with large angular velocity and high resolution
This article proposes an inertial piezoelectric actuator with hybrid design of asymmetrically clamping structures and a bias unit for the achievement of large angular velocity and high resolution. To investigate the influence of asymmetrical clamp and bias unit on the driving performance, two types of actuators were fabricated and tested. Combined effects from asymmetrical clamp and bias unit contribute to type A, while their subtractive effect is applied to type B. Using a scanning laser vibrometer, experiments were conducted to analyze the characteristics of the angular displacement and corresponding velocity. It is indicated that the measured first-order natural frequencies for above two types are 13.828 and 14.141 Hz, which agrees well with the simulation results of 16.666 and 17.379 Hz, respectively. Besides, compared with the actuators with simple asymmetrical clamping structure or bias unit, this hybrid actuator can obtain an angular velocity 6.87 rad/s at 80 V and 16 Hz and a resolution of 2.80 μrad under a square signal of 20 V and 1 Hz and an offset distance of −22 mm. As a result, the proposed actuators can achieve large angular velocity and high resolution, which is potentially applicable to quick positioning with high accuracy.
- 14 December 2018
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 28 (1) , 015030
Novel inertial piezoelectric actuator with high precision and stability based on a two fixed-end beam structure
A novel inertial piezoelectric actuator is proposed in this study to address the large vibration problem in piezoelectric actuators with a typical cantilever structure. Piezoelectric vibrators with a two fixed-end beam structure were designed as driving elements to improve the precision and stability of the proposed actuator. Simulation and experiments were performed to evaluate the vibration model of the vibrators. A series of experiments was conducted to evaluate the performance of the presented actuator with regard to its linearity, repeatability, and output stepping. Angular resolution can reach 0.453 μ rad at 36 V, 40 Hz, and 600 g load. Under the conditions of 40 V, 40 Hz, and 400 g load, repeatability reaches 0.0024 mrad with a maximum deviation of 0.007 mrad. Experimental results show that the designed actuator can achieve high precision and high stability under load conditions. This novel actuator has a reference value and significance in practical applications that require microdisplacement.
- 14 December 2018
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 28 (1) , 015030
Novel inertial piezoelectric actuator with high precision and stability based on a two fixed-end beam structure
A novel inertial piezoelectric actuator is proposed in this study to address the large vibration problem in piezoelectric actuators with a typical cantilever structure. Piezoelectric vibrators with a two fixed-end beam structure were designed as driving elements to improve the precision and stability of the proposed actuator. Simulation and experiments were performed to evaluate the vibration model of the vibrators. A series of experiments was conducted to evaluate the performance of the presented actuator with regard to its linearity, repeatability, and output stepping. Angular resolution can reach 0.453 μ rad at 36 V, 40 Hz, and 600 g load. Under the conditions of 40 V, 40 Hz, and 400 g load, repeatability reaches 0.0024 mrad with a maximum deviation of 0.007 mrad. Experimental results show that the designed actuator can achieve high precision and high stability under load conditions. This novel actuator has a reference value and significance in practical applications that require microdisplacement.