VFViolaine Foltz

Violaine Foltz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Violaine Foltz has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Psychometric Validation of the LBP-BSTv2 for Assessing Maladaptive Beliefs in Patients With Non-Specific Low Back Pain

    by Christophe Demoulin, Thibault Desjardins, Irène Salamun, Michael Norberg, Violaine Foltz, Florian Bailly, Laurent Pitance, Jean-François Kaux, Romain Artico

    Objective: To assess maladaptive beliefs about low back pain (LBP), valid and reliable measurement tools are required. Although some tools exist to assess them, the Low Back Pain-related Beliefs Screening Tool (LBP-BST) was developed in order to explore all different categories of misbeliefs in individuals chronic low back pain (CLBP). This study aimed to evaluate the main psychometric properties of both the short and long versions of the revised LBPBSTv2.Methods: A total of 108 patients with CLBP completed the LBP-BSTv2 to assess its potential floor/ceiling effects, internal consistency, and construct validity. The latter was evaluated by comparing scores with the Back Beliefs Questionnaire (BBQ). Test-retest reliability was assessed in 47 of the participants one week later.Results: No floor or ceiling effects were observed. The short and long versions of the LBPBSTv2 showed strong construct validity, with significant correlations with BBQ scores. Internal consistency was acceptable to good (Cronbach’s alpha: 0.77–0.84), and test-retest reliability was high (intraclass correlation coefficient: 0.76–0.81).Conclusion: The LBP-BSTv2 is a valid and reliable tool for assessing maladaptive beliefs in patients with CLBP. Its integration into clinical practice could help healthcare professionals identify and address unhelpful beliefs that may hinder rehabilitation. Further research is needed to confirm its usefulness in tracking changes over time and guiding individualized interventions and to study other psychometric properties such as responsiveness.

  • Development and Validation of an OMERACT MRI Whole-Body Score for Inflammation in Peripheral Joints and Entheses in Inflammatory Arthritis (MRI-WIPE)

    by Simon Krabbe, Iris Eshed, Frédérique Gandjbakhch, Susanne J. Pedersen, Paul Bird, Ashish J. Mathew, Robert G. Lambert, Walter P. Maksymowych, Daniel Glinatsi, Maria S. Stoenoiu, et al.

    Objective.: To develop a whole-body magnetic resonance imaging (MRI) scoring system for peripheral arthritis and enthesitis.Methods.: After consensus on definitions/locations of MRI pathologies, 4 multireader exercises were performed. Eighty-three joints were scored 0–3 separately for synovitis and osteitis, and 33 entheses 0–3 separately for soft tissue inflammation and osteitis.Results.: In the last exercise, reliability was moderate-good for musculoskeletal radiologists and rheumatologists with previously demonstrated good scoring proficiency. Median pairwise single-measure/average-measure ICC were 0.67/0.80 for status scores and 0.69/0.82 for change scores; κ ranged 0.35–0.77.Conclusion.: Whole-body MRI scoring of peripheral arthritis and enthesitis is reliable, which encourages further testing and refinement in clinical trials.


  • The OMERACT MRI in Enthesitis Initiative: Definitions of Key Pathologies, Suggested MRI Sequences, and a Novel Heel Enthesitis Scoring System

    by Ashish J. Mathew, Simon Krabbe, Iris Eshed, Frédérique Gandjbakhch, Paul Bird, Susanne J. Pedersen, Maria S. Stoenoiu, Violaine Foltz, Daniel Glinatsi, Robert G. Lambert, et al.

    Objective.: To develop and validate an enthesitis magnetic resonance imaging (MRI) scoring system for spondyloarthritis/psoriatic arthritis, using the heel as model.Methods.: Consensus definitions of key pathologies and 3 heel enthesitis multireader scoring exercises were done, separated by discussion, training, and calibration.Results.: Definitions for bone and soft tissue pathologies were agreed. In the final exercise, median pairwise single-measures intraclass correlation coefficients (ICC; patient-level) for entheseal inflammation status/change scores were 0.83/0.82 for all readers. For radiologists and selected rheumatologists, ICC were 0.91/0.84 and quadratic-weighted κ (lesion-level) 0.57–0.91/0.45–0.81.Conclusion.: The proposed definitions and Heel Enthesitis Scoring System (HEMRIS) are reliable among trained readers and promising for clinical trials.


  • Longitudinal Reliability of the OMERACT Thumb Base Osteoarthritis Magnetic Resonance Imaging Scoring System (TOMS)

    by Féline P.B. Kroon, Sjoerd van Beest, Frédérique Gandjbakhch, Charles G. Peterfy, Su Chen, Philip G. Conaghan, Iris Eshed, Violaine Foltz, Harry K. Genant, Ida K. Haugen, et al.

    Objective.: To assess the longitudinal reliability of the Outcome Measures in Rheumatology (OMERACT) Thumb base Osteoarthritis Magnetic resonance imaging (MRI) Scoring system (TOMS). Methods.: Paired MRI of patients with hand osteoarthritis were scored in 2 exercises (6-mo and 2-yr followup) for synovitis, subchondral bone defects (SBD), osteophytes, cartilage assessment, bone marrow lesions (BML), and subluxation. Interreader reliability of delta scores was assessed. Results.: Little change occurred. Average-measure intraclass correlation coefficients were good-excellent (≥ 0.71), except synovitis (0.55–0.83) and carpometacarpal-1 osteophytes/cartilage assessment (0.47/0.39). Percentage exact/close agreement was 52–92%/68–100%, except BML in 2 years (28%/64–76%). Smallest detectable change was below the scoring increment, except in SBD and BML. Conclusion.: TOMS longitudinal reliability was moderate-good. Limited change hampered assessment.


  • Open Access

    Développement et validation d’un questionnaire identifiant différentes stratégies comportementales chez les patients lombalgiques chroniques

    by Florian Bailly, Violaine Foltz, Sylvie Rozenberg, Michael Norberg, Joëlle Glemarec, Sophie Pouplin, Béatrice Banneville, Christophe Demoulin, Véronique Gaud-Listrat, Bruno Fautrel, et al.

  • Open Access

    Physical Activity Assessment Using an Activity Tracker in Patients with Rheumatoid Arthritis and Axial Spondyloarthritis: Prospective Observational Study

    by Charlotte Jacquemin, Hervé Servy, Anna Molto, Jérémie Sellam, Violaine Foltz, Frédérique Gandjbakhch, Christophe Hudry, Stéphane Mitrovic, Bruno Fautrel, Laure Gossec

    Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.


  • Open Access

    Physical Activity Assessment Using an Activity Tracker in Patients with Rheumatoid Arthritis and Axial Spondyloarthritis: Prospective Observational Study (Preprint)

    by Charlotte Jacquemin, Hervé Servy, Anna Molto, Jérémie Sellam, Violaine Foltz, Frédérique Gandjbakhch, Christophe Hudry, Stéphane Mitrovic, Bruno Fautrel, Laure Gossec

    BACKGROUND Physical activity can be tracked using mobile devices and is recommended in rheumatoid arthritis (RA) and axial spondyloarthritis (axSpA) management. The World Health Organization (WHO) recommends at least 150 min per week of moderate to vigorous physical activity (MVPA). OBJECTIVE The objectives of this study were to assess and compare physical activity and its patterns in patients with RA and axSpA using an activity tracker and to assess the feasibility of mobile devices in this population. METHODS This multicentric prospective observational study (ActConnect) included patients who had definite RA or axSpA, and a smartphone. Physical activity was assessed over 3 months using a mobile activity tracker, recording the number of steps per minute. The number of patients reaching the WHO recommendations was calculated. RA and axSpA were compared, using linear mixed models, for number of steps, proportion of morning steps, duration of total activity, and MVPA. Physical activity trajectories were identified using the K-means method, and factors related to the low activity trajectory were explored by logistic regression. Acceptability was assessed by the mean number of days the tracker was worn over the 3 months (ie, adherence), the percentage of wearing time, and by an acceptability questionnaire. RESULTS A total of 157 patients (83 RA and 74 axSpA) were analyzed; 36.3% (57/157) patients were males, and their mean age was 46 (standard deviation [SD] 12) years and mean disease duration was 11 (SD 9) years. RA and axSpA patients had similar physical activity levels of 16 (SD 11) and 15 (SD 12) min per day of MVPA (P=.80), respectively. Only 27.4% (43/157) patients reached the recommendations with a mean MVPA of 106 (SD 77) min per week. The following three trajectories were identified with constant activity: low (54.1% [85/157] of patients), moderate (42.7% [67/157] of patients), and high (3.2% [5/157] of patients) levels of MVPA. A higher body mass index was significantly related to less physical activity (odds ratio 1.12, 95% CI 1.11-1.14). The activity trackers were worn during a mean of 79 (SD 17) days over the 90 days follow-up. Overall, patients considered the use of the tracker very acceptable, with a mean score of 8 out 10. CONCLUSIONS Patients with RA and axSpA performed insufficient physical activity with similar levels in both groups, despite the differences between the 2 diseases. Activity trackers allow longitudinal assessment of physical activity in these patients. The good adherence to this study and the good acceptability of wearing activity trackers confirmed the feasibility of the use of a mobile activity tracker in patients with rheumatic diseases.