Eliska Sedlackova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eliska Sedlackova has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Lukas Richtera
Department of Chemistry and Biochemistry, Mendel University in Brno, Zemědělská 1, 613 00 Brno, Czech Republic
10 shared publications - Vojtech Adam
Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University in Brno, Zemedelska 1, Brno CZ-613 00, Czech Republic
5 shared publications - Zuzana Bytesnikova
Department of Chemistry and Biochemistry, Mendel University in Brno, Brno, Czech Republic
3 shared publications - Amir M. Ashrafi
Department of Chemistry and Biochemistry, Mendel University in Brno, CZ-613 00 Brno, Czech Republic
2 shared publications - Pedro Estrela
Department of Electronic and Electrical Engineering, University of Bath, Bath, BA2 7AY, United Kingdom; Centre for Bioengineering & Biomedical Technologies (CBio), University of Bath, Bath, BA2 7AY, United Kingdom
2 shared publications Vojtech Adam
2 shared publications
Latest Publications
- Open Access
Label-Free DNA Biosensor Using Modified Reduced Graphene Oxide Platform as a DNA Methylation Assay
This work reports the use of modified reduced graphene oxide (rGO) as a platform for a label-free DNA-based electrochemical biosensor as a possible diagnostic tool for a DNA methylation assay. The biosensor sensitivity was enhanced by variously modified rGO. The rGO decorated with three nanoparticles (NPs)—gold (AuNPs), silver (AgNPs), and copper (CuNPs)—was implemented to increase the electrode surface area. Subsequently, the thiolated DNA probe (single-stranded DNA, ssDNA−1) was hybridized with the target DNA sequence (ssDNA-2). After the hybridization, the double-stranded DNA (dsDNA) was methylated by M.SssI methyltransferase (MTase) and then digested via a HpaII endonuclease specific site sequence of CpG (5′-CCGG-3′) islands. For monitoring the MTase activity, differential pulse voltammetry (DPV) was used, whereas the best results were obtained by rGO-AuNPs. This assay is rapid, cost-effective, sensitive, selective, highly specific, and displays a low limit of detection (LOD) of 0.06 U·mL−1. Lastly, this study was enriched with the real serum sample, where a 0.19 U·mL−1 LOD was achieved. Moreover, the developed biosensor offers excellent potential in future applications in clinical diagnostics, as this approach can be used in the design of other biosensors.
Open AccessLabel-Free DNA Biosensor Using Modified Reduced Graphene Oxide Platform as a DNA Methylation Assay
This work reports the use of modified reduced graphene oxide (rGO) as a platform for a label-free DNA-based electrochemical biosensor as a possible diagnostic tool for a DNA methylation assay. The biosensor sensitivity was enhanced by variously modified rGO. The rGO decorated with three nanoparticles (NPs)—gold (AuNPs), silver (AgNPs), and copper (CuNPs)—was implemented to increase the electrode surface area. Subsequently, the thiolated DNA probe (single-stranded DNA, ssDNA−1) was hybridized with the target DNA sequence (ssDNA-2). After the hybridization, the double-stranded DNA (dsDNA) was methylated by M.SssI methyltransferase (MTase) and then digested via a HpaII endonuclease specific site sequence of CpG (5′-CCGG-3′) islands. For monitoring the MTase activity, differential pulse voltammetry (DPV) was used, whereas the best results were obtained by rGO-AuNPs. This assay is rapid, cost-effective, sensitive, selective, highly specific, and displays a low limit of detection (LOD) of 0.06 U·mL−1. Lastly, this study was enriched with the real serum sample, where a 0.19 U·mL−1 LOD was achieved. Moreover, the developed biosensor offers excellent potential in future applications in clinical diagnostics, as this approach can be used in the design of other biosensors.
- Open Access
- 13 April 2020
- Published by MDPI AG in Biosensors
- Vol. 10 (4) , 36
Integrated Electrochemical Biosensors for Detection of Waterborne Pathogens in Low-Resource Settings
More than 783 million people worldwide are currently without access to clean and safe water. Approximately 1 in 5 cases of mortality due to waterborne diseases involve children, and over 1.5 million cases of waterborne disease occur every year. In the developing world, this makes waterborne diseases the second highest cause of mortality. Such cases of waterborne disease are thought to be caused by poor sanitation, water infrastructure, public knowledge, and lack of suitable water monitoring systems. Conventional laboratory-based techniques are inadequate for effective on-site water quality monitoring purposes. This is due to their need for excessive equipment, operational complexity, lack of affordability, and long sample collection to data analysis times. In this review, we discuss the conventional techniques used in modern-day water quality testing. We discuss the future challenges of water quality testing in the developing world and how conventional techniques fall short of these challenges. Finally, we discuss the development of electrochemical biosensors and current research on the integration of these devices with microfluidic components to develop truly integrated, portable, simple to use and cost-effective devices for use by local environmental agencies, NGOs, and local communities in low-resource settings.
- 13 April 2020
- Published by MDPI AG in Biosensors
- Vol. 10 (4) , 36
Open AccessIntegrated Electrochemical Biosensors for Detection of Waterborne Pathogens in Low-Resource Settings
More than 783 million people worldwide are currently without access to clean and safe water. Approximately 1 in 5 cases of mortality due to waterborne diseases involve children, and over 1.5 million cases of waterborne disease occur every year. In the developing world, this makes waterborne diseases the second highest cause of mortality. Such cases of waterborne disease are thought to be caused by poor sanitation, water infrastructure, public knowledge, and lack of suitable water monitoring systems. Conventional laboratory-based techniques are inadequate for effective on-site water quality monitoring purposes. This is due to their need for excessive equipment, operational complexity, lack of affordability, and long sample collection to data analysis times. In this review, we discuss the conventional techniques used in modern-day water quality testing. We discuss the future challenges of water quality testing in the developing world and how conventional techniques fall short of these challenges. Finally, we discuss the development of electrochemical biosensors and current research on the integration of these devices with microfluidic components to develop truly integrated, portable, simple to use and cost-effective devices for use by local environmental agencies, NGOs, and local communities in low-resource settings.
- Open Access
- 1 January 2020
- Published by TANGER Ltd.
- Vol. 2020, 282-287
Nanoparticle-based World – ORIGIN OF LIFE THEORY
- 1 January 2020
- Published by TANGER Ltd.
- Vol. 2020, 282-287
Open AccessNanoparticle-based World – ORIGIN OF LIFE THEORY
- 1 January 2020
- Published by TANGER Ltd.
- Vol. 2019, 385-390
HIGHLY SELECTIVE AND SENSITIVE ELECTROCHEMICAL BIOSENSOR BASED ON ELECTROCHEMICALLY REDUCED GRAPHENE OXIDE FOR DETECTION OF MIRNA AS A CANCER BIOMARKER
- 1 January 2020
- Published by TANGER Ltd.
- Vol. 2019, 385-390
HIGHLY SELECTIVE AND SENSITIVE ELECTROCHEMICAL BIOSENSOR BASED ON ELECTROCHEMICALLY REDUCED GRAPHENE OXIDE FOR DETECTION OF MIRNA AS A CANCER BIOMARKER
- 1 January 2020
- Published by TANGER Ltd.
- Vol. 2019, 402-405
GOLD NANOPARTICLES MODIFIED SCREEN PRINTED CARBON ELECTRODE AS A TOOL FOR DETECTION OF TP53
- 1 January 2020
- Published by TANGER Ltd.
- Vol. 2019, 402-405
GOLD NANOPARTICLES MODIFIED SCREEN PRINTED CARBON ELECTRODE AS A TOOL FOR DETECTION OF TP53
- Open Access
- 8 July 2019
- Published by MDPI AG in Proceedings
- Vol. 15 (1) , 13
Effect of Graphene Oxide Modification on a DNA Biosensor Developed for the Detection of Methylated DNA Associated with Cancer
Methylated DNA is a covalent post-translational modification, which plays a crucial role in pathological and physiological processes including several diseases, such as cardiovascular disease, diabetes or cancer. Despite that, methylated DNA presents a new generation of biomarkers, which brings a promising alternative for using in point-care diagnostic. Regarding this fact, DNA based electrochemical sensors enable fast, reliable, low-cost, time-consuming and efficient detection. The application of these biosensors as possible alternatives for the determination of methylated DNA is recently growing. Therefore, a biosensor for the determination of methylated DNA was fabricated. This study was aimed to develop an efficient biosensor, with an amplified electrochemical signal which is suited for the detection of the low-level concentration of methylated DNA. The bare gold electrode was first covered with the graphene oxide modified with gold, silver and copper nanoparticles. These composites have a strong affinity to DNA probe and their effect on the sensitivity and selectivity of the biosensor was investigated. The developed biosensor shows promising analytical characteristics with a wide detection linear range. The electrochemical impedance spectroscopy (EIS) was used to detect the hybridization of the DNA probe with methylated DNA target.
- 8 July 2019
- Published by MDPI AG in Proceedings
- Vol. 15 (1) , 13
Open AccessEffect of Graphene Oxide Modification on a DNA Biosensor Developed for the Detection of Methylated DNA Associated with Cancer
Methylated DNA is a covalent post-translational modification, which plays a crucial role in pathological and physiological processes including several diseases, such as cardiovascular disease, diabetes or cancer. Despite that, methylated DNA presents a new generation of biomarkers, which brings a promising alternative for using in point-care diagnostic. Regarding this fact, DNA based electrochemical sensors enable fast, reliable, low-cost, time-consuming and efficient detection. The application of these biosensors as possible alternatives for the determination of methylated DNA is recently growing. Therefore, a biosensor for the determination of methylated DNA was fabricated. This study was aimed to develop an efficient biosensor, with an amplified electrochemical signal which is suited for the detection of the low-level concentration of methylated DNA. The bare gold electrode was first covered with the graphene oxide modified with gold, silver and copper nanoparticles. These composites have a strong affinity to DNA probe and their effect on the sensitivity and selectivity of the biosensor was investigated. The developed biosensor shows promising analytical characteristics with a wide detection linear range. The electrochemical impedance spectroscopy (EIS) was used to detect the hybridization of the DNA probe with methylated DNA target.
- Open Access
Application of the Enzymatic Electrochemical Biosensors for Monitoring Non-Competitive Inhibition of Enzyme Activity by Heavy Metals
The inhibition effect of the selected heavy metals (Ag+, Cd2+, Cu2+, and Hg2+) on glucose oxidase (GOx) enzyme from Aspergillus niger (EC 1.1.3.4.) was studied using a new amperometric biosensor with an electrochemical transducer based on a glassy carbon electrode (GCE) covered with a thin layer of multi-wall carbon nanotubes (MWCNTs) incorporated with ruthenium(IV) oxide as a redox mediator. Direct adsorption of multi-wall carbon nanotubes (MWCNTs) and subsequent covering with Nafion® layer was used for immobilization of Gox. The analytical figures of merit of the developed glucose (Glc) biosensor are sufficient for determination of Glc in body fluids in clinical analysis. From all tested heavy metals, mercury(II) has the highest inhibition effect. However, it is necessary to remember that cadmium and silver ions also significantly inhibit the catalytic activity of Gox. Therefore, the development of Gox biosensors for selective indirect determination of each heavy metal still represents a challenge in the field of bioelectroanalysis. It can be concluded that amperometric biosensors, differing in the utilized enzyme, could find their application in the toxicity studies of various poisons.
Open AccessApplication of the Enzymatic Electrochemical Biosensors for Monitoring Non-Competitive Inhibition of Enzyme Activity by Heavy Metals
The inhibition effect of the selected heavy metals (Ag+, Cd2+, Cu2+, and Hg2+) on glucose oxidase (GOx) enzyme from Aspergillus niger (EC 1.1.3.4.) was studied using a new amperometric biosensor with an electrochemical transducer based on a glassy carbon electrode (GCE) covered with a thin layer of multi-wall carbon nanotubes (MWCNTs) incorporated with ruthenium(IV) oxide as a redox mediator. Direct adsorption of multi-wall carbon nanotubes (MWCNTs) and subsequent covering with Nafion® layer was used for immobilization of Gox. The analytical figures of merit of the developed glucose (Glc) biosensor are sufficient for determination of Glc in body fluids in clinical analysis. From all tested heavy metals, mercury(II) has the highest inhibition effect. However, it is necessary to remember that cadmium and silver ions also significantly inhibit the catalytic activity of Gox. Therefore, the development of Gox biosensors for selective indirect determination of each heavy metal still represents a challenge in the field of bioelectroanalysis. It can be concluded that amperometric biosensors, differing in the utilized enzyme, could find their application in the toxicity studies of various poisons.
- 11 December 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (16) , B824-B834
Review—Electrochemical Sensors and Biosensors for Determination of Mercury Ions
Due to its toxicity, mercury determination is of great importance in human health and pollution monitoring. The mercury compounds can be released into our environment in several ways. Therefore, so many analytical procedures have been developed for detection of mercury. In this review, the analytical methods used for determination of mercury ions have been reported highlighting the electrochemical methods and in particular electrochemical biosensors. The electrochemical biosensors for determination of mercury were categorized into three groups including DNA-based, enzyme-based and whole-cell based biosensors and the mechanisms of the function of each group were described. The advantages and challenges of each class of biosensors are discussed in this review.
- 11 December 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (16) , B824-B834
Review—Electrochemical Sensors and Biosensors for Determination of Mercury Ions
Due to its toxicity, mercury determination is of great importance in human health and pollution monitoring. The mercury compounds can be released into our environment in several ways. Therefore, so many analytical procedures have been developed for detection of mercury. In this review, the analytical methods used for determination of mercury ions have been reported highlighting the electrochemical methods and in particular electrochemical biosensors. The electrochemical biosensors for determination of mercury were categorized into three groups including DNA-based, enzyme-based and whole-cell based biosensors and the mechanisms of the function of each group were described. The advantages and challenges of each class of biosensors are discussed in this review.
- 11 May 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (24) , 2917-2923
Determination of chromium( vi ) by anodic stripping voltammetry using a silver-plated glassy carbon electrode
In this work, differential pulse anodic stripping voltammetry (DP-ASV) for the determination of trace amounts of hexavalent chromium (Cr(VI)) at a silver plated glassy carbon electrode (Ag plated-GCE) is described in detail. A Ag film was prepared by in situ plating of silver on the glassy carbon electrode surface. Several solution conditions and instrumental parameters influencing the electroanalytical response of the Ag plated-GCE were examined and optimized for the determination of Cr(VI). Under the optimized conditions, the calibration curve obtained in CH3COOH/NH3 (aq) medium at pH 5.9 was linear over the wide concentration range of 0.35–40 μM Cr(VI). The present method shows a low limit of detection of 0.10 μM. After evaluation of effects from possible interferences, the proposed method was successfully applied for the quantification of Cr(VI) in real water samples, with satisfactory recovery (97–105%). This method is useful for the determination of chromium in drinking water and achieves sensitivity capable of detecting the limits set by the World Health Organization (WHO).
- 11 May 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (24) , 2917-2923
Determination of chromium( vi ) by anodic stripping voltammetry using a silver-plated glassy carbon electrode
In this work, differential pulse anodic stripping voltammetry (DP-ASV) for the determination of trace amounts of hexavalent chromium (Cr(VI)) at a silver plated glassy carbon electrode (Ag plated-GCE) is described in detail. A Ag film was prepared by in situ plating of silver on the glassy carbon electrode surface. Several solution conditions and instrumental parameters influencing the electroanalytical response of the Ag plated-GCE were examined and optimized for the determination of Cr(VI). Under the optimized conditions, the calibration curve obtained in CH3COOH/NH3 (aq) medium at pH 5.9 was linear over the wide concentration range of 0.35–40 μM Cr(VI). The present method shows a low limit of detection of 0.10 μM. After evaluation of effects from possible interferences, the proposed method was successfully applied for the quantification of Cr(VI) in real water samples, with satisfactory recovery (97–105%). This method is useful for the determination of chromium in drinking water and achieves sensitivity capable of detecting the limits set by the World Health Organization (WHO).