Junho Bang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junho Bang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Barun Basnet
Dept. of IT Applied System Engineering, Jeonbuk National University, Republic of Korea
4 shared publications - Mohammad Hadi Nazari
Department of IT Applied Engineering, Jeonbuk National University, Jeonju 54896, Republic of Korea
2 shared publications Chong-Deuk Lee
Chonbuk National University
1 shared publication- Deun-Chan Kim
Department of IT Applied System Engineering, Jeonbuk National University, Jeonju 54896, Republic of Korea
1 shared publication - Hyun Sung Lim
Department of Future Technology Research, Electrical Safety Institute, Wanju, 55365, Korea
1 shared publication Hyunjun Chun
Dept. of IT Applied System Engineering, Jeonbuk National University, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Wind Resource Assessment Using Measured and ERA5 Data for Wind Turbine Performance Evaluation at a Coastal Site in South Korea
This study evaluates the wind energy potential and coastal wind turbine suitability at a coastal site in South Korea using two-year measured wind data and ERA5 reanalysis data. Wind characteristics, Weibull parameters, wind power density, and turbine energy performance were analyzed using Windographer. ERA5 showed similar seasonal and directional patterns to the measured data, supporting its use for wind resource comparison and validation over the available measurement period. Among four candidate turbines, the Vestas V112-3.0 MW achieved the highest Net AEP, while the GE 1.7-100 showed the highest NCF. Finally, the CRITIC–TOPSIS method was applied using five technical and energy criteria, identifying the Vestas V112-3.0 MW as the highest-ranked under the selected technical–energy criteria with a closeness coefficient of 0.5547.
Open AccessWind Resource Assessment Using Measured and ERA5 Data for Wind Turbine Performance Evaluation at a Coastal Site in South Korea
This study evaluates the wind energy potential and coastal wind turbine suitability at a coastal site in South Korea using two-year measured wind data and ERA5 reanalysis data. Wind characteristics, Weibull parameters, wind power density, and turbine energy performance were analyzed using Windographer. ERA5 showed similar seasonal and directional patterns to the measured data, supporting its use for wind resource comparison and validation over the available measurement period. Among four candidate turbines, the Vestas V112-3.0 MW achieved the highest Net AEP, while the GE 1.7-100 showed the highest NCF. Finally, the CRITIC–TOPSIS method was applied using five technical and energy criteria, identifying the Vestas V112-3.0 MW as the highest-ranked under the selected technical–energy criteria with a closeness coefficient of 0.5547.
- 12 October 2026
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 21 (7) , 5433-5446
Source-Side Uncertainty Assessment and Multi-Scale Wind Power Forecasting from an Anonymized Multi-Turbine Wind-Farm SCADA Dataset with High Abnormality Rates for High-Density Load Integration
- 12 October 2026
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 21 (7) , 5433-5446
Source-Side Uncertainty Assessment and Multi-Scale Wind Power Forecasting from an Anonymized Multi-Turbine Wind-Farm SCADA Dataset with High Abnormality Rates for High-Density Load Integration
- Open Access
A Terrain-Structured Dual-Pareto Framework for Saemangeum Wind-Farm Re-Planning Under Measured Wind, Wake-Loss, and Cost-Chain Constraints
Wind-farm re-planning must reconcile wind resources, wake interactions, cable routing, foundation and installation requirements, grid access, land/water-use cost, and operation and maintenance. This study develops a terrain-structured dual-Pareto framework for the Saemangeum complex coastal site on the southwest coast of the Republic of Korea, along the inner side of its 33.9 km seawall. Stage I aggregates planning-scale points into 12 regional engineering nodes and screens them using five objectives; Stage II evaluates 43,722 layouts with 12–22 turbines inside the retained envelope. The complete 2018 wind record provides the sole full-year search and economic-evaluation basis. Under the common planning model, the selected 20-turbine, 132 MW scenario is estimated to deliver 288.7 GWh with an estimated LCOE of 184.2 USD/MWh. Relative to the 99.2 MW public proxy baseline, installed capacity rises by 33.1%, total modeled energy by 43.4%, and modeled energy per MW by about 7.8%; these are aggregate modernization-and-re-planning differences, not algorithm-only effects. In the matched eight-seed, same-technology comparison, the methods show economically comparable screening LCOE and no systematic AEP or wake-loss advantage. The dual-layer search nevertheless shortens collection cable and lowers the common terrain-adjusted CAPEX proxy in all eight seeds. The fixed layouts are also evaluated over the independently held January–July 2019 record without annualization: the main layout is estimated to deliver 159.0 GWh over 5088 valid hours, with a partial-period capacity factor of 23.7%. This held-out-period assessment does not establish annual or long-term climatic robustness.
Open AccessA Terrain-Structured Dual-Pareto Framework for Saemangeum Wind-Farm Re-Planning Under Measured Wind, Wake-Loss, and Cost-Chain Constraints
Wind-farm re-planning must reconcile wind resources, wake interactions, cable routing, foundation and installation requirements, grid access, land/water-use cost, and operation and maintenance. This study develops a terrain-structured dual-Pareto framework for the Saemangeum complex coastal site on the southwest coast of the Republic of Korea, along the inner side of its 33.9 km seawall. Stage I aggregates planning-scale points into 12 regional engineering nodes and screens them using five objectives; Stage II evaluates 43,722 layouts with 12–22 turbines inside the retained envelope. The complete 2018 wind record provides the sole full-year search and economic-evaluation basis. Under the common planning model, the selected 20-turbine, 132 MW scenario is estimated to deliver 288.7 GWh with an estimated LCOE of 184.2 USD/MWh. Relative to the 99.2 MW public proxy baseline, installed capacity rises by 33.1%, total modeled energy by 43.4%, and modeled energy per MW by about 7.8%; these are aggregate modernization-and-re-planning differences, not algorithm-only effects. In the matched eight-seed, same-technology comparison, the methods show economically comparable screening LCOE and no systematic AEP or wake-loss advantage. The dual-layer search nevertheless shortens collection cable and lowers the common terrain-adjusted CAPEX proxy in all eight seeds. The fixed layouts are also evaluated over the independently held January–July 2019 record without annualization: the main layout is estimated to deliver 159.0 GWh over 5088 valid hours, with a partial-period capacity factor of 23.7%. This held-out-period assessment does not establish annual or long-term climatic robustness.
- Open Access
Android-Based Real-Time Classification of Electric Fire Short-Circuit Traces Using Lightweight Deep Learning Model
This paper presents a lightweight deep learning framework for classifying electric fire short-circuit traces to enhance safety and fault diagnosis in electrical energy systems. Accurate differentiation between primary (PSCT) and secondary short-circuit traces (SSCT) is essential for identifying failure origins, yet conventional manual inspection is time-consuming and subjective. To address these limitations, we systematically evaluate three lightweight convolutional neural network (CNN) architectures MobileNetV2, MobileNetV3, and EfficientNet using transfer learning on a domain-specific image dataset. The models are assessed based on accuracy, loss, precision, recall, and F1-score. Experimental results show that EfficientNet achieves the highest classification accuracy, while MobileNetV3 demonstrates the lowest validation loss and superior generalization stability. Based on a performance–efficiency trade-off analysis, MobileNetV3 is deployed on an Android platform using TensorFlow Lite, enabling real-time, offline, and on-device inference. To the best of our knowledge, this is among the first studies to integrate lightweight CNN-based short-circuit trace classification with real-time mobile deployment for on-site energy system fault analysis. By bridging the gap between deep learning and field deployment, the proposed mobile system ensures low-latency execution and provides a rapid, reliable, and portable solution for improving operational safety in electrical fire investigations.
Open AccessAndroid-Based Real-Time Classification of Electric Fire Short-Circuit Traces Using Lightweight Deep Learning Model
This paper presents a lightweight deep learning framework for classifying electric fire short-circuit traces to enhance safety and fault diagnosis in electrical energy systems. Accurate differentiation between primary (PSCT) and secondary short-circuit traces (SSCT) is essential for identifying failure origins, yet conventional manual inspection is time-consuming and subjective. To address these limitations, we systematically evaluate three lightweight convolutional neural network (CNN) architectures MobileNetV2, MobileNetV3, and EfficientNet using transfer learning on a domain-specific image dataset. The models are assessed based on accuracy, loss, precision, recall, and F1-score. Experimental results show that EfficientNet achieves the highest classification accuracy, while MobileNetV3 demonstrates the lowest validation loss and superior generalization stability. Based on a performance–efficiency trade-off analysis, MobileNetV3 is deployed on an Android platform using TensorFlow Lite, enabling real-time, offline, and on-device inference. To the best of our knowledge, this is among the first studies to integrate lightweight CNN-based short-circuit trace classification with real-time mobile deployment for on-site energy system fault analysis. By bridging the gap between deep learning and field deployment, the proposed mobile system ensures low-latency execution and provides a rapid, reliable, and portable solution for improving operational safety in electrical fire investigations.
- Open Access
- 26 May 2026
- Published by MDPI AG in Preprints.org
Android-Based Real-Time Classification of Electric Fire Short-Circuit Traces Using Lightweight Deep Learning Model
This paper presents a lightweight deep learning framework for classifying electric fire short-circuit traces to enhance safety and fault diagnosis in electrical energy systems. Accurate differentiation between primary (PSCT) and secondary short-circuit traces (SSCT) is essential for identifying failure origins, yet conventional manual inspection is time-consuming and subjective. To address these limitations, we systematically evaluate three lightweight convolutional neural network (CNN) architectures MobileNetV2, MobileNetV3, and EfficientNet using transfer learning on a domain-specific image dataset. The models are assessed based on accuracy, loss, precision, recall, and F1-score. Experimental results show that EfficientNet achieves the highest classification accuracy, while MobileNetV3 demonstrates the lowest validation loss and superior generalization stability. Based on a performance-efficiency trade-off analysis, MobileNetV3 is deployed on an Android platform using TensorFlow Lite, enabling real-time, offline, and on-device inference. To the best of our knowledge, this is among the first studies to integrate lightweight CNN-based short-circuit trace classification with real-time mobile deployment for on-site energy system fault analysis. By bridging the gap between deep learning and field deployment, the proposed mobile system ensures low-latency execution and provides a rapid, reliable, and portable solution for improving operational safety in electrical fire investigations.
- 26 May 2026
- Published by MDPI AG in Preprints.org
Open AccessAndroid-Based Real-Time Classification of Electric Fire Short-Circuit Traces Using Lightweight Deep Learning Model
This paper presents a lightweight deep learning framework for classifying electric fire short-circuit traces to enhance safety and fault diagnosis in electrical energy systems. Accurate differentiation between primary (PSCT) and secondary short-circuit traces (SSCT) is essential for identifying failure origins, yet conventional manual inspection is time-consuming and subjective. To address these limitations, we systematically evaluate three lightweight convolutional neural network (CNN) architectures MobileNetV2, MobileNetV3, and EfficientNet using transfer learning on a domain-specific image dataset. The models are assessed based on accuracy, loss, precision, recall, and F1-score. Experimental results show that EfficientNet achieves the highest classification accuracy, while MobileNetV3 demonstrates the lowest validation loss and superior generalization stability. Based on a performance-efficiency trade-off analysis, MobileNetV3 is deployed on an Android platform using TensorFlow Lite, enabling real-time, offline, and on-device inference. To the best of our knowledge, this is among the first studies to integrate lightweight CNN-based short-circuit trace classification with real-time mobile deployment for on-site energy system fault analysis. By bridging the gap between deep learning and field deployment, the proposed mobile system ensures low-latency execution and provides a rapid, reliable, and portable solution for improving operational safety in electrical fire investigations.
- Open Access
Reinforcement Learning-Based Optimization of Environmental Control Systems in Battery Energy Storage Rooms
This study proposes a reinforcement learning (RL)-based optimization framework for the environmental control system of battery rooms in Energy Storage Systems (ESS). Conventional rule-based air-conditioning strategies are unable to adapt to real-time temperature and humidity fluctuations, often leading to excessive energy consumption or insufficient thermal protection. To overcome these limitations, both value-based (DQN, Double DQN, Dueling DQN) and policy-based (Policy Gradient, PPO, TRPO) RL algorithms are implemented and systematically compared. The algorithms are trained and evaluated using one year of real ESS operational data and corresponding meteorological data sampled at 15-min intervals. Performance is assessed in terms of convergence speed, learning stability, and cooling-energy consumption. The experimental results show that the DQN algorithm reduces time-averaged cooling power consumption by 46.5% compared to conventional rule-based control, while maintaining temperature, humidity, and dew-point constraint violation rates below 1% throughout the testing period. Among the policy-based methods, the Policy Gradient algorithm demonstrates competitive energy-saving performance but requires longer training time and exhibits higher reward variance. These findings confirm that RL-based control can effectively adapt to dynamic environmental conditions, thereby improving both energy efficiency and operational safety in ESS battery rooms. The proposed framework offers a practical and scalable solution for intelligent thermal management in ESS facilities.
Open AccessReinforcement Learning-Based Optimization of Environmental Control Systems in Battery Energy Storage Rooms
This study proposes a reinforcement learning (RL)-based optimization framework for the environmental control system of battery rooms in Energy Storage Systems (ESS). Conventional rule-based air-conditioning strategies are unable to adapt to real-time temperature and humidity fluctuations, often leading to excessive energy consumption or insufficient thermal protection. To overcome these limitations, both value-based (DQN, Double DQN, Dueling DQN) and policy-based (Policy Gradient, PPO, TRPO) RL algorithms are implemented and systematically compared. The algorithms are trained and evaluated using one year of real ESS operational data and corresponding meteorological data sampled at 15-min intervals. Performance is assessed in terms of convergence speed, learning stability, and cooling-energy consumption. The experimental results show that the DQN algorithm reduces time-averaged cooling power consumption by 46.5% compared to conventional rule-based control, while maintaining temperature, humidity, and dew-point constraint violation rates below 1% throughout the testing period. Among the policy-based methods, the Policy Gradient algorithm demonstrates competitive energy-saving performance but requires longer training time and exhibits higher reward variance. These findings confirm that RL-based control can effectively adapt to dynamic environmental conditions, thereby improving both energy efficiency and operational safety in ESS battery rooms. The proposed framework offers a practical and scalable solution for intelligent thermal management in ESS facilities.
- 6 April 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (6) , 4329-4339
Classification of Short Circuit Marks in Electric Fire Case with Transfer Learning and Fine-Tuning the Convolutional Neural Network Models
- 6 April 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (6) , 4329-4339
Classification of Short Circuit Marks in Electric Fire Case with Transfer Learning and Fine-Tuning the Convolutional Neural Network Models
- 20 April 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 17 (6) , 3593-3599
Statistical Analysis of Ignition Time and Energy of the TFR-CV Cable Ignition Experiments Using 100 W DC Arc
- 20 April 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 17 (6) , 3593-3599
Statistical Analysis of Ignition Time and Energy of the TFR-CV Cable Ignition Experiments Using 100 W DC Arc
- Open Access
- 9 June 2020
- Published by Wiley in Journal of Sensors
- Vol. 2020, 1-11
An Intelligent Fault Detection Model for Fault Detection in Photovoltaic Systems
Effective fault diagnosis in a PV system requires understanding the behavior of the current/voltage (I/V) parameters in different environmental conditions. Especially during the winter season, I/V characters of certain faulty states in a PV system closely resemble that of a normal state. Therefore, a normal fault detection model can falsely predict a well-operating PV system as a faulty state and vice versa. In this paper, an intelligent fault diagnosis model is proposed for the fault detection and classification in PV systems. For the experimental verification, various fault state and normal state datasets are collected during the winter season under wide environmental conditions. The collected datasets are normalized and preprocessed using several data-mining techniques and then fed into a probabilistic neural network (PNN). The PNN model will be trained with the historical data to predict and classify faults when new data is fetched in it. The trained model showed better performance in prediction accuracy when compared with other classification methods in machine learning.
- 9 June 2020
- Published by Wiley in Journal of Sensors
- Vol. 2020, 1-11
Open AccessAn Intelligent Fault Detection Model for Fault Detection in Photovoltaic Systems
Effective fault diagnosis in a PV system requires understanding the behavior of the current/voltage (I/V) parameters in different environmental conditions. Especially during the winter season, I/V characters of certain faulty states in a PV system closely resemble that of a normal state. Therefore, a normal fault detection model can falsely predict a well-operating PV system as a faulty state and vice versa. In this paper, an intelligent fault diagnosis model is proposed for the fault detection and classification in PV systems. For the experimental verification, various fault state and normal state datasets are collected during the winter season under wide environmental conditions. The collected datasets are normalized and preprocessed using several data-mining techniques and then fed into a probabilistic neural network (PNN). The PNN model will be trained with the historical data to predict and classify faults when new data is fetched in it. The trained model showed better performance in prediction accuracy when compared with other classification methods in machine learning.
- Open Access
- 16 December 2018
- Published by Wiley in Journal of Sensors
- Vol. 2018, 1
Corrigendum to “The State-of-the-Art of Knowledge-Intensive Agriculture: A Review on Applied Sensing Systems and Data Analytics”
- 16 December 2018
- Published by Wiley in Journal of Sensors
- Vol. 2018, 1
Open AccessCorrigendum to “The State-of-the-Art of Knowledge-Intensive Agriculture: A Review on Applied Sensing Systems and Data Analytics”