Xiaogang Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaogang Wu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Daobin Zhang
Wuhan University
2 shared publications- Hui Zhang
Department of Environmental Science and Engineering, Wuhan University, Wuhan, China
2 shared publications Bo Peng
School of Urban Construction, Yangtze University, Jingzhou, Hubei, 434103, China
1 shared publication- Gang Han
School of Urban Construction, Yangtze University, Jingzhou 434023, China
1 shared publication Hui Zhang
Professor, Dept. of Environmental Engineering, Wuhan Univ., P.O. Box C319 Luoyu Rd. 129#, Wuhan 430079, China
1 shared publicationJia Ai
A Department of Environmental Engineering, Hubei Biomass-Resource Chemistry and Environmental Biotechnology Key Laboratory, Wuhan University , Wuhan , People's Republic of China
1 shared publication
Latest Publications
- Open Access
Combining Ultraviolet Photolysis with In-Situ Electrochemical Oxidation for Degrading Sulfonamides in Wastewater
Ultraviolet photolysis (UVC, 254 nm) was coupled with an electrochemical oxidation process to degrade three kinds of veterinary sulfonamide (sulfamethazine [SMZ] tablets, sulfamonomethoxine [SMM] tablets, and compound sulfamethoxazole [SMX] tablets). The treatment was applied using a flat ceramic microfiltration membrane to study the effects of photocatalysts. The effectiveness of degradation of the three sulfonamides was evaluated under different conditions. Dissolved oxygen was provided via aeration, but this resulted in a large decrease in the degradation effectiveness due to the inhibition of free chlorine electrogeneration. The photocatalysts had no promotional effect on sulfonamide removal from wastewater due to reduced UV penetration. Because of the different distribution coefficients of sulfonamides, UV irradiation had different effects on different sulfonamide species. For SMZ and SMM, anionic species exhibited a higher degradation rate, whereas for SMX, degradation was most effective for neutral species. In addition, the free chlorine yield increased as the pH increased. Free chlorine conversion reactions occurred under UV irradiation, with the reactions possibly restrained by sulfonamides. Reactive chlorine species promoted SMM degradation. Compared to UV irradiation or electrochemical oxidation alone, the UV/in-situ electrochemical oxidation process was more effective and is suitable for treating real wastewater under various environmental pH levels.
Open AccessCombining Ultraviolet Photolysis with In-Situ Electrochemical Oxidation for Degrading Sulfonamides in Wastewater
Ultraviolet photolysis (UVC, 254 nm) was coupled with an electrochemical oxidation process to degrade three kinds of veterinary sulfonamide (sulfamethazine [SMZ] tablets, sulfamonomethoxine [SMM] tablets, and compound sulfamethoxazole [SMX] tablets). The treatment was applied using a flat ceramic microfiltration membrane to study the effects of photocatalysts. The effectiveness of degradation of the three sulfonamides was evaluated under different conditions. Dissolved oxygen was provided via aeration, but this resulted in a large decrease in the degradation effectiveness due to the inhibition of free chlorine electrogeneration. The photocatalysts had no promotional effect on sulfonamide removal from wastewater due to reduced UV penetration. Because of the different distribution coefficients of sulfonamides, UV irradiation had different effects on different sulfonamide species. For SMZ and SMM, anionic species exhibited a higher degradation rate, whereas for SMX, degradation was most effective for neutral species. In addition, the free chlorine yield increased as the pH increased. Free chlorine conversion reactions occurred under UV irradiation, with the reactions possibly restrained by sulfonamides. Reactive chlorine species promoted SMM degradation. Compared to UV irradiation or electrochemical oxidation alone, the UV/in-situ electrochemical oxidation process was more effective and is suitable for treating real wastewater under various environmental pH levels.
- 1 December 2021
- Published by American Scientific Publishers in Science of Advanced Materials
- Vol. 13 (12) , 2450-2459
Simultaneous Degradation of p-Nitrophenol and Recovery of Copper from Wastewater in Electrochemical Reactor Under High Salinity
Ti/RuO2–IrO2 electrode was used in this study as an anode, while titanium plate (Ti) was used as a cathode for electrochemical oxidation process, to explore the influences of related parameters on degradation of p-nitrophenol (PNP) and removal of Cu2+ from mixed simulated wastewater. Using a single chamber reactor, we tested the influence of various factors on the PNP degradation and Cu2+ elimination. The factors that were tested are as follow; the type of electrolyte, density of the current, various values of pH and different concentrations of Cu2+. Furthermore, a dual-chamber diaphragm reactor compartmentalized by cationic membrane was utilized to explore the removal mechanism of PNP and Cu2+. Results showed that, treatment of PNP-Cu2+ simulated wastewater, with NaCl as electrolyte, had a better effect compared with Na2SO4, which had characteristics such as shorter reaction time and higher degradation efficiency for PNP. Removal of Cu2+ had no obvious advantage over Na2SO4. The degradation of PNP and removal of Cu2+ were improved with increased current density when the rang was increased from 10 to 40 mA/cm2. Cu2+ concentration when increased initially promoted the degradation of PNP. At the same time, Cu2+ acted as electron acceptor at the cathode that slowed down the consumption of H+ through reduced combination of H+ with electrons. The degradation rate of PNP decreased with increased initial pH, but the Cu2+ was opposite. In this experiment, the degradation of PNP was positively correlated with indirect oxidation of active chlorine, and the Cu2+ was removed by cathodic electrodeposition.
- 1 December 2021
- Published by American Scientific Publishers in Science of Advanced Materials
- Vol. 13 (12) , 2450-2459
Simultaneous Degradation of p-Nitrophenol and Recovery of Copper from Wastewater in Electrochemical Reactor Under High Salinity
Ti/RuO2–IrO2 electrode was used in this study as an anode, while titanium plate (Ti) was used as a cathode for electrochemical oxidation process, to explore the influences of related parameters on degradation of p-nitrophenol (PNP) and removal of Cu2+ from mixed simulated wastewater. Using a single chamber reactor, we tested the influence of various factors on the PNP degradation and Cu2+ elimination. The factors that were tested are as follow; the type of electrolyte, density of the current, various values of pH and different concentrations of Cu2+. Furthermore, a dual-chamber diaphragm reactor compartmentalized by cationic membrane was utilized to explore the removal mechanism of PNP and Cu2+. Results showed that, treatment of PNP-Cu2+ simulated wastewater, with NaCl as electrolyte, had a better effect compared with Na2SO4, which had characteristics such as shorter reaction time and higher degradation efficiency for PNP. Removal of Cu2+ had no obvious advantage over Na2SO4. The degradation of PNP and removal of Cu2+ were improved with increased current density when the rang was increased from 10 to 40 mA/cm2. Cu2+ concentration when increased initially promoted the degradation of PNP. At the same time, Cu2+ acted as electron acceptor at the cathode that slowed down the consumption of H+ through reduced combination of H+ with electrons. The degradation rate of PNP decreased with increased initial pH, but the Cu2+ was opposite. In this experiment, the degradation of PNP was positively correlated with indirect oxidation of active chlorine, and the Cu2+ was removed by cathodic electrodeposition.
- 17 December 2018
- Published by Springer Nature in Chemical Papers
- Vol. 73 (5) , 1145-1152
A Ti/IrO2–RuO2–TiO2 anode in the Fered-Fenton process: preparation and performance in the removal of chemical oxygen demand from biochemically treated leachate
- 17 December 2018
- Published by Springer Nature in Chemical Papers
- Vol. 73 (5) , 1145-1152
A Ti/IrO2–RuO2–TiO2 anode in the Fered-Fenton process: preparation and performance in the removal of chemical oxygen demand from biochemically treated leachate
- 16 September 2017
- Published by Taylor & Francis in Environmental Technology
- Vol. 40 (17) , 2225-2231
Treatment of landfill leachate with combined biological and chemical processes: changes in the dissolved organic matter and functional groups
Leachates contain complicated and hazardous substances that need multiple treatment processes to meet the discharge standards. Few studies have considered the changes in different fractions, based on their molecular weight (MW), of dissolved organic matter, during the different treatment processes. In this study, we investigated the application of a biological method, using sequencing batch reactors, and a chemical method, using the electro-Fenton oxidation process, in combination. The combined treatment, and the electro-Fenton process alone, was applied to a landfill leachate. Samples taken at various points during the treatment processes were fractionated according to their MW using ultra-membranes; this divided the samples into their less biodegradable constituents (0.45 μm: >10 kDa MW), their bio-refractory constituents (10–1 kDa MW) and their biodegradable constituents (<1 kDa MW). The dominant contributors to the chemical oxygen demand (COD) in the raw leachate comprised the biodegradable constituents (79% of total COD). The COD was reduced to 33.6% and 18.5% of its original levels, by the electro-Fenton process alone and the combined treatment, respectively. Based on the absorption intensities in the Fourier transform infrared (FTIR) spectra, the functional groups in the raw leachate were reduced by the biological treatment, but changed by the electro-Fenton process.
- 16 September 2017
- Published by Taylor & Francis in Environmental Technology
- Vol. 40 (17) , 2225-2231
Treatment of landfill leachate with combined biological and chemical processes: changes in the dissolved organic matter and functional groups
Leachates contain complicated and hazardous substances that need multiple treatment processes to meet the discharge standards. Few studies have considered the changes in different fractions, based on their molecular weight (MW), of dissolved organic matter, during the different treatment processes. In this study, we investigated the application of a biological method, using sequencing batch reactors, and a chemical method, using the electro-Fenton oxidation process, in combination. The combined treatment, and the electro-Fenton process alone, was applied to a landfill leachate. Samples taken at various points during the treatment processes were fractionated according to their MW using ultra-membranes; this divided the samples into their less biodegradable constituents (0.45 μm: >10 kDa MW), their bio-refractory constituents (10–1 kDa MW) and their biodegradable constituents (<1 kDa MW). The dominant contributors to the chemical oxygen demand (COD) in the raw leachate comprised the biodegradable constituents (79% of total COD). The COD was reduced to 33.6% and 18.5% of its original levels, by the electro-Fenton process alone and the combined treatment, respectively. Based on the absorption intensities in the Fourier transform infrared (FTIR) spectra, the functional groups in the raw leachate were reduced by the biological treatment, but changed by the electro-Fenton process.
- 1 March 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 138 (3) , 278-285
Statistical Experiment Design Approach for the Treatment of Landfill Leachate by Photoelectro-Fenton Process
The influence of different variables in the photoelectro-Fenton process for the treatment of landfill leachate was investigated using an experimental design methodology. The variables considered in this study include ferrous ion dosage, hydrogen peroxide concentration, and current density. Response factors were color removal and chemical-oxygen demand (COD) removal efficiency after a 90-min reaction. The response surface methodology models were derived based on the results of color removal and COD removal, and the response surface plots were developed accordingly. The organic components before and after application of the photoelectro-Fenton process were investigated by gas chromatography-mass spectroscopy.
- 1 March 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 138 (3) , 278-285
Statistical Experiment Design Approach for the Treatment of Landfill Leachate by Photoelectro-Fenton Process
The influence of different variables in the photoelectro-Fenton process for the treatment of landfill leachate was investigated using an experimental design methodology. The variables considered in this study include ferrous ion dosage, hydrogen peroxide concentration, and current density. Response factors were color removal and chemical-oxygen demand (COD) removal efficiency after a 90-min reaction. The response surface methodology models were derived based on the results of color removal and COD removal, and the response surface plots were developed accordingly. The organic components before and after application of the photoelectro-Fenton process were investigated by gas chromatography-mass spectroscopy.