Ki Yong An
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ki Yong An has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Young Woo Chung
Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
6 shared publications - Woojin Shin
Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
4 shared publications - Hyun Ju Lee
Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
2 shared publications Jae-Woong Seo
Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
2 shared publications- Jiyeon Park
Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
2 shared publications - Ki Hyun Kwon
Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, Korea
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by XMLink in Journal of the Korean Orthopaedic Association
- Vol. 61 (3) , 241-248
Influence of Leg and Trunk Muscle Mass on FRAX-Predicted Fracture Risk and Frailty after Osteoporotic Vertebral Fracture: A DXA-Based Study
An KY, et al. J Korean Orthop Assoc. 2026 Sep;61(3):241-248. https://doi.org/10.4055/jkoa.2026.61.3.241
- 1 January 2026
- Published by XMLink in Journal of the Korean Orthopaedic Association
- Vol. 61 (3) , 241-248
Open AccessInfluence of Leg and Trunk Muscle Mass on FRAX-Predicted Fracture Risk and Frailty after Osteoporotic Vertebral Fracture: A DXA-Based Study
An KY, et al. J Korean Orthop Assoc. 2026 Sep;61(3):241-248. https://doi.org/10.4055/jkoa.2026.61.3.241
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (1) , 148-156
Does the Proximal Humerus Nail with 2 Distal Screws Provide Sufficient Rotational Stability?
An KY, et al. Clin Orthop Surg. 2025 Feb;17(1):148-156. https://doi.org/10.4055/cios23150
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (1) , 148-156
Open AccessDoes the Proximal Humerus Nail with 2 Distal Screws Provide Sufficient Rotational Stability?
An KY, et al. Clin Orthop Surg. 2025 Feb;17(1):148-156. https://doi.org/10.4055/cios23150
- Open Access
- 1 December 2023
- Published by Korean Society for Surgery of the Hand in Archives of Hand and Microsurgery
- Vol. 28 (4) , 267-274
The usefulness of bioabsorbable magnesium implants in addition to metal plates in the treatment of complex distal radius fractures
Purpose: The aim of this study was to determine whether normal plating yields comparable outcomes to plating using additional bioabsorbable screws or wires for complex distal radial fractures.Methods: Among 80 patients with complex distal radius fractures treated between January 2018 and March 2021, 45 were studied retrospectively and divided into two groups as follows: group A (n=23) received a plate, and group B (n=22) received a plate with a bioresorbable screw or wire. Radiological studies evaluated the period of bone union, radial length, inclination, and resorption of the bioresorbable screws or wires after surgery. The Disabilities of the Arm, Shoulder, and Hand (DASH) score was examined for clinical evaluation, and complications were compared between the two groups.Results: The two groups showed similar distributions in sex, age, injury mechanism, diabetes mellitus, smoking, and mean follow-up period; however, there were no statistically significant differences in the period of bone union and maintenance of reduction (radial length, inclination, and volar tilt). The DASH score averaged 14.8 and 13.2 points in groups A and B, respectively, showing no significant difference in complications (nonunion, malunion, infection, and arthritis).Conclusion: Regardless of the use of additional bioresorbable screws or wires, reduction in distal radius fractures in both groups yielded good results. Plating with additional bioresorbable screws or wires may be a suitable fixation method to compensate for the shortcomings of metal implants in complex distal radius fractures.
- 1 December 2023
- Published by Korean Society for Surgery of the Hand in Archives of Hand and Microsurgery
- Vol. 28 (4) , 267-274
Open AccessThe usefulness of bioabsorbable magnesium implants in addition to metal plates in the treatment of complex distal radius fractures
Purpose: The aim of this study was to determine whether normal plating yields comparable outcomes to plating using additional bioabsorbable screws or wires for complex distal radial fractures.Methods: Among 80 patients with complex distal radius fractures treated between January 2018 and March 2021, 45 were studied retrospectively and divided into two groups as follows: group A (n=23) received a plate, and group B (n=22) received a plate with a bioresorbable screw or wire. Radiological studies evaluated the period of bone union, radial length, inclination, and resorption of the bioresorbable screws or wires after surgery. The Disabilities of the Arm, Shoulder, and Hand (DASH) score was examined for clinical evaluation, and complications were compared between the two groups.Results: The two groups showed similar distributions in sex, age, injury mechanism, diabetes mellitus, smoking, and mean follow-up period; however, there were no statistically significant differences in the period of bone union and maintenance of reduction (radial length, inclination, and volar tilt). The DASH score averaged 14.8 and 13.2 points in groups A and B, respectively, showing no significant difference in complications (nonunion, malunion, infection, and arthritis).Conclusion: Regardless of the use of additional bioresorbable screws or wires, reduction in distal radius fractures in both groups yielded good results. Plating with additional bioresorbable screws or wires may be a suitable fixation method to compensate for the shortcomings of metal implants in complex distal radius fractures.
- Open Access
- 1 January 2023
- Published by XMLink in Journal of the Korean Orthopaedic Association
- Vol. 58 (1) , 62-66
Delayed Pneumothorax after Thoracic Paravertebral Block
심대무, et al. J Korean Orthop Assoc. 2023 Feb;58(1):62-66. https://doi.org/10.4055/jkoa.2023.58.1.62
- 1 January 2023
- Published by XMLink in Journal of the Korean Orthopaedic Association
- Vol. 58 (1) , 62-66
Open AccessDelayed Pneumothorax after Thoracic Paravertebral Block
심대무, et al. J Korean Orthop Assoc. 2023 Feb;58(1):62-66. https://doi.org/10.4055/jkoa.2023.58.1.62
- Open Access
- 1 January 2022
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 57 (6) , 482-489
Is the Insertion of a Drain Tube and Irrigation as Effective as Arthroscopic Synovectomy in Treating Septic Arthritis of the Knee?
권기현, et al. J Korean Orthop Assoc. 2022 Dec;57(6):482-489. https://doi.org/10.4055/jkoa.2022.57.6.482
- 1 January 2022
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 57 (6) , 482-489
Open AccessIs the Insertion of a Drain Tube and Irrigation as Effective as Arthroscopic Synovectomy in Treating Septic Arthritis of the Knee?
권기현, et al. J Korean Orthop Assoc. 2022 Dec;57(6):482-489. https://doi.org/10.4055/jkoa.2022.57.6.482
- Open Access
- 1 January 2022
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 57 (4) , 275-283
Nerve Block for Upper Extremity Surgery
- 1 January 2022
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 57 (4) , 275-283
Open AccessNerve Block for Upper Extremity Surgery
- Open Access
- 1 January 2021
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 56 (2) , 142-149
Efficacy of Tranexamic Acid during Primary Total Knee Arthroplasty: Comparative Study between Intravenous Use and Topical Use
- 1 January 2021
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 56 (2) , 142-149
Open AccessEfficacy of Tranexamic Acid during Primary Total Knee Arthroplasty: Comparative Study between Intravenous Use and Topical Use
- Open Access
- 1 December 2020
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 23 (4) , 205-209
Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture
Simple clavicle shaft fracture typically achieves satisfactory union after treatment and does not result in complication with conservative treatment. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet Bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet Bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.
- 1 December 2020
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 23 (4) , 205-209
Open AccessAdditional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture
Simple clavicle shaft fracture typically achieves satisfactory union after treatment and does not result in complication with conservative treatment. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet Bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet Bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.
- Open Access
- 1 December 2020
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 23 (4) , 197-200
Treatment of instability with scapular notching and glenoid component loosing by partial mixed different implant revision
In general, reverse shoulder arthroplasty revision is performed using the same implant for both the humerus and glenoid components. However, the authors of the present case used different implants from what was used previously for treating instability with scapular notching and glenoid aseptic loosening and report the case.
- 1 December 2020
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 23 (4) , 197-200
Open AccessTreatment of instability with scapular notching and glenoid component loosing by partial mixed different implant revision
In general, reverse shoulder arthroplasty revision is performed using the same implant for both the humerus and glenoid components. However, the authors of the present case used different implants from what was used previously for treating instability with scapular notching and glenoid aseptic loosening and report the case.
- Open Access
- 1 June 2020
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 23 (2) , 100-104
Reverse shoulder arthroplasty with os acromiale
Function and strength of the deltoid muscle are important in reverse shoulder arthroplasty (RSA). Moreover, location and shape of the acromion, clavicle, and scapular spine, which are origins of the deltoid muscle, are also important. The frequency of os acromiale is 5% to 15%; however, it is rare in the Asian population, affecting approximately 0.7% of Koreans. RSA has rarely been reported in patients with os acromiale. We present a case series of two patients with cuff tear and arthropathy combined with os acromiale who underwent RSA. From 2016 to 2018, two patients with os acromiale who presented with pain and limited range of motion (ROM) underwent RSA with cuff tear arthropathy using the subscapularis-sparing deltopectoral approach. Their ROM, visual analog scale (VAS), and satisfaction were evaluated before and after surgery. In both patients, VAS decreased, ROM increased, and postoperative satisfaction increased. There were no specific complications due to os acromiale. The VAS, ROM, and satisfaction of patients improved after surgery compared with values before surgery. Thus, os acromiale is not a contraindication for RSA. However, careful attention must be given during surgery to ensure optimal repair and recovery.
- 1 June 2020
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 23 (2) , 100-104
Open AccessReverse shoulder arthroplasty with os acromiale
Function and strength of the deltoid muscle are important in reverse shoulder arthroplasty (RSA). Moreover, location and shape of the acromion, clavicle, and scapular spine, which are origins of the deltoid muscle, are also important. The frequency of os acromiale is 5% to 15%; however, it is rare in the Asian population, affecting approximately 0.7% of Koreans. RSA has rarely been reported in patients with os acromiale. We present a case series of two patients with cuff tear and arthropathy combined with os acromiale who underwent RSA. From 2016 to 2018, two patients with os acromiale who presented with pain and limited range of motion (ROM) underwent RSA with cuff tear arthropathy using the subscapularis-sparing deltopectoral approach. Their ROM, visual analog scale (VAS), and satisfaction were evaluated before and after surgery. In both patients, VAS decreased, ROM increased, and postoperative satisfaction increased. There were no specific complications due to os acromiale. The VAS, ROM, and satisfaction of patients improved after surgery compared with values before surgery. Thus, os acromiale is not a contraindication for RSA. However, careful attention must be given during surgery to ensure optimal repair and recovery.