ASAbhishek Sachan

Abhishek Sachan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abhishek Sachan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Proof-of-Concept of Pressure-Ulcer-Associated VOC Biomarkers’ Detection Using a Nanocomposite-Based Quantum Resistive Vapour Sensor Array

    by Manh Trung Tran, Abhishek Sachan, Mickaël Castro, Jean-François Feller

    Pressure ulcers (PUs), commonly referred to as bedsores, are a major health problem for which early detection remains challenging. Volatile organic compounds (VOCs) released from pressure-affected skin have been proposed as potential biomarkers, providing a complementary approach to conventional visual and pressure-based monitoring. In this study, a cross-reactive electronic nose (e-nose) comprising nine quantum resistive vapour sensors (vQRSs) was evaluated for the detection of three VOCs previously associated with pressure-ulcer-related skin emissions: benzyl alcohol, pentadecane and 1-tetradecene. The vQRS transducers consisted of carbon nanotube (CNT) networks functionalized with different polymer matrices, namely poly (vinylpyrrolidone), poly (vinyl acetate), poly (lactic acid), poly (ethylene glycol), poly (caprolactone), poly (methyl methacrylate), poly (styrene-co-acrylonitrile), polystyrene and sulfonated poly (ether ether ketone). The individual sensors were first evaluated using benzyl alcohol and water vapour at concentrations ranging from approximately 100 ppb to 1 ppm. A measurable response was obtained at 100 ppb, with signal-to-noise ratios exceeding five for six vQRSs. Water vapour modified the response amplitude and apparent sensitivity to benzyl alcohol, highlighting the importance of humidity effects under skin-relevant conditions. The sensor array was subsequently exposed to synthetic mixtures containing the selected biomarkers in a complex VOC background with controlled water vapour content. Principal component analysis (PCA) of the sensor responses enabled discrimination between the different biomarker-containing mixtures, their concentrations, and the background mixture. Combining the maximum response amplitude with the integrated response area further improved separation in the PCA score space compared with amplitude alone. PCA was used as an exploratory visualization tool; no supervised classification or cross-validation was performed, and the data were obtained from synthetic mixtures and a single background donor. These results demonstrate the feasibility of using a cross-reactive CNT/polymer vQRS array to detect pressure-ulcer-associated VOC signatures under controlled laboratory conditions. The study illustrates the possible recognition of synthetic blends of three candidate VOCs added to a healthy-skin background (one donor, four skin sites). Further studies using real skin emissions from individuals will target the discrimination between healthy and patients with pressure ulcers to assess the robustness and clinical diagnostic value of the approach.

  • Open Access

    Analysis of Olfactive Prints from Artificial Lung Cancer Volatolome with Nanocomposite-Based vQRS Arrays for Healthcare

    by Abhishek Sachan, Mickaël Castro, Jean-François Feller

    Exhaled breath analysis is emerging as one of the most promising non-invasive strategies for the early detection of life-threatening diseases, especially lung cancer, where rapid and reliable diagnosis remains a major clinical challenge. In this study, we designed and optimized an electronic nose (e-nose) platform composed of quantum resistive vapor sensors (vQRSs) engineered by polymer-carbon nanotube nanocomposites via spray layer-by-layer assembly. Each sensor was tailored through specific polymer functionalization to tune selectivity and enhance sensitivity toward volatile organic compounds (VOCs) of medical relevance. The sensor array, combined with linear discriminant analysis (LDA), demonstrated the ability to accurately discriminate between cancer-related biomarkers in synthetic blends, even when present at trace concentrations within complex volatile backgrounds. Beyond artificial mixtures, the system successfully distinguished real exhaled breath samples collected under challenging conditions, including before and after smoking and alcohol consumption. These results not only validate the robustness and reproducibility of the vQRS-based array but also highlight its potential as a versatile diagnostic tool. Overall, this work underscores the relevance of nanocomposite chemo-resistive arrays for breathomics and paves the way for their integration into future portable e-nose devices dedicated to telemedicine, continuous monitoring, and early-stage disease diagnosis.


  • Open Access

    Emerging Strategies Based on Sensors for Chronic Wound Monitoring and Management

    by Manh-Trung Tran, Abhishek Kumar, Abhishek Sachan, Mickaël Castro, Willy Allegre, Jean-François Feller

    Pressure ulcers (PUs) are a serious global health challenge, affecting a large section of the population and putting immense pressure on healthcare systems. Sensor-based diagnostic tools and monitoring systems have emerged as a potential non-invasive solution to reduce the occurrence of new cases of PUs and promise a significant reduction in treatment expenditure and time. In this endeavour, the present manuscript reviews the advancements made in the last decade in the development and commercial adoption of different sensor systems for PU-associated chronic wound management. Different types of smart sensor systems have been developed in which pressure, chemical, and optical sensors have witnessed a lot of interest and significant advancement among research communities and industries alike. These sensors utilize a host of nanomaterial-based sensing materials, flexible support, diverse transducing modes, and different device designs to achieve high sensitivity and selectivity for skin pressure, temperature, humidity, and biomarkers released from the wound. Some of these sensor’s array-based electronic skin (e-skin) has reached the stage of commercialization and is being used in commercial products, such as smart bandages, shoes, watches, and mattress among others. Nonetheless, further innovations are necessary in the direction of associating multiple types of sensor arrays, particularly pressure and chemical sensor-based e-skins in a microsystem for performing real-time assessment of all the critical wound parameters.


  • Open Access

    Influence of Water Molecules on the Detection of Volatile Organic Compounds (VOC) Cancer Biomarkers by Nanocomposite Quantum Resistive Vapor Sensors vQRS

    by Abhishek Sachan, Mickaël Castro, Veena Choudhary, Jean-Francois Feller

    The anticipated diagnosis of various fatal diseases from the analysis of volatile organic compounds (VOC) biomarkers of the volatolome is the object of very dynamic research. Nanocomposite-based quantum resistive vapor sensors (vQRS) exhibit strong advantages in the detection of biomarkers, as they can operate at room temperature with low consumption and sub ppm (part per million) sensitivity. However, to meet this application they need to detect some ppm or less amounts of biomarkers in patients’ breath, skin, or urine in complex blends of numerous VOC, most of the time hindered by a huge amount of water molecules. Therefore, it is crucial to analyze the effects of moisture on the chemo-resistive sensing behavior of carbon nanotubes based vQRS. We show that in the presence of water molecules, the sensors cannot detect the right amount of VOC molecules present in their environment. These perturbations of the detection mechanism are found to depend on the chemical interactions between water and other VOC molecules, but also on their competitive absorption on sensors receptive sites, located at the nanojunctions of the conductive architecture. This complex phenomenon studied with down to 12.5 ppm of acetone, ethanol, butanone, toluene, and cyclohexane mixed with 100 ppm of water was worth to investigate in the prospect of future developments of devices analysing real breath samples in which water can reach a concentration of 6%.