Alexa N. Buck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexa N. Buck has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Jan Wilbert Hendrik Schnupp
Gerald Choa Neuroscience Institute, Chinese University of Hong Kong, Hong Kong S.A.R
7 shared publications - Nicole Rosskothen-Kuhl
Neurobiological Research Laboratory, Section for Experimental and Clinical Otology Department of Otorhinolaryngology Faculty of Medicine Medical Center – University of Freiburg Freiburg Germany
7 shared publications - Sarah Buchholz
Faculty of Biology University of Freiburg Freiburg Germany
3 shared publications Henrike Budig
Neurobiological Research Laboratory, Section for Experimental and Clinical Otology, Department of Otorhinolaryngology, Medical Center–University of Freiburg, Faculty of Medicine
1 shared publicationHenrike K Budig
Medical Center -University of Freiburg, Faculty of Medicine, University of Freiburg, Germany
1 shared publication- Kongyan Li
Department of Electrical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
When the First Pulse Fades: 75% Reduction in Precedence Effect in Cochlear Implanted Rats
It is widely known that users of cochlear implants (CIs) often show deficits in binaural hearing. In particular, interaural time difference (ITD) discrimination tends to be substantially worse in CI users. However, only very few studies have investigated how CI stimulation affects the “precedence effect” (PE), and how this might be affected by abnormal hearing experience during development. We performed behavioral experiments to measure temporal weighting functions (TWFs) to quantify the PE in three different cohorts of rats: normally hearing (NH) acoustically stimulated, neonatally deafened (ND) CI-stimulated, and adult deafened (AD) CI-stimulated animals. Lateralization responses were recorded to bursts of eight stimulus pulses in which the ITD of each pulse varied independently, and probit analysis revealed the perceptual weight of each pulse. The NH and ND-CI cohorts were tested at 50, 300, and 900 pps; the AD-CI animals were tested only at 300 pps. The NH animals show a pronounced “onset dominance” at higher pulse rates, that is, the weighting of the first pulse was much larger than for subsequent pulses, exactly as one would expect given previous studies on human listeners. In contrast, the TWFs for the ND-CI and AD-CI animals were much flatter, with a reduction of onset dominance by ∼75%, especially for higher pulse rates. Since neither of our CI cohorts had any experience of reverberation in their electric hearing, we interpret these results to indicate that the PE may require domain-specific experience to develop.
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Open AccessWhen the First Pulse Fades: 75% Reduction in Precedence Effect in Cochlear Implanted Rats
It is widely known that users of cochlear implants (CIs) often show deficits in binaural hearing. In particular, interaural time difference (ITD) discrimination tends to be substantially worse in CI users. However, only very few studies have investigated how CI stimulation affects the “precedence effect” (PE), and how this might be affected by abnormal hearing experience during development. We performed behavioral experiments to measure temporal weighting functions (TWFs) to quantify the PE in three different cohorts of rats: normally hearing (NH) acoustically stimulated, neonatally deafened (ND) CI-stimulated, and adult deafened (AD) CI-stimulated animals. Lateralization responses were recorded to bursts of eight stimulus pulses in which the ITD of each pulse varied independently, and probit analysis revealed the perceptual weight of each pulse. The NH and ND-CI cohorts were tested at 50, 300, and 900 pps; the AD-CI animals were tested only at 300 pps. The NH animals show a pronounced “onset dominance” at higher pulse rates, that is, the weighting of the first pulse was much larger than for subsequent pulses, exactly as one would expect given previous studies on human listeners. In contrast, the TWFs for the ND-CI and AD-CI animals were much flatter, with a reduction of onset dominance by ∼75%, especially for higher pulse rates. Since neither of our CI cohorts had any experience of reverberation in their electric hearing, we interpret these results to indicate that the PE may require domain-specific experience to develop.
- Open Access
- 17 April 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 122 (16)
Pulse timing dominates binaural hearing with cochlear implants
Although cochlear implants (CIs) provide valuable auditory information to more than one million profoundly deaf patients, these devices remain inadequate in conveying fine timing cues. Early deaf patients in particular struggle to use interaural time differences (ITDs) for spatial hearing and auditory scene analysis. Why CI patients experience these limitations remains controversial. One possible explanation, which we investigate here, is that the stimulation by clinical CIs is inappropriate, as it encodes temporal features of sounds only in the envelope of electrical pulse trains, not the pulse timing. We have recently demonstrated that early deaf, adult implanted rats fitted with bilateral CIs that deliver carefully timed pulses routinely develop sensitivity to very small ITDs. Here we show that, while the early deafened mammalian auditory pathway can innately easily resolve pulse timing ITDs as small as 80 µs, it is many times less sensitive to the ITDs of pulse train envelopes. Our results indicate that the stimulation strategies in current clinical use do not present ITD cues in a manner that the inexperienced auditory pathway is highly sensitive to. This may deprive early deaf CI patients of the opportunity to hone their submillisecond temporal processing skills as they learn to hear through their prosthetic devices.
- 17 April 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 122 (16)
Open AccessPulse timing dominates binaural hearing with cochlear implants
Although cochlear implants (CIs) provide valuable auditory information to more than one million profoundly deaf patients, these devices remain inadequate in conveying fine timing cues. Early deaf patients in particular struggle to use interaural time differences (ITDs) for spatial hearing and auditory scene analysis. Why CI patients experience these limitations remains controversial. One possible explanation, which we investigate here, is that the stimulation by clinical CIs is inappropriate, as it encodes temporal features of sounds only in the envelope of electrical pulse trains, not the pulse timing. We have recently demonstrated that early deaf, adult implanted rats fitted with bilateral CIs that deliver carefully timed pulses routinely develop sensitivity to very small ITDs. Here we show that, while the early deafened mammalian auditory pathway can innately easily resolve pulse timing ITDs as small as 80 µs, it is many times less sensitive to the ITDs of pulse train envelopes. Our results indicate that the stimulation strategies in current clinical use do not present ITD cues in a manner that the inexperienced auditory pathway is highly sensitive to. This may deprive early deaf CI patients of the opportunity to hone their submillisecond temporal processing skills as they learn to hear through their prosthetic devices.
- Open Access
Is Inappropriate Pulse Timing Responsible for Poor Binaural Hearing with Cochlear Implants?
Cochlear implants (CIs) have restored enough of a sense of hearing to around one million severely hearing impaired patients to enable speech understanding in quiet. However, several aspects of hearing with CIs remain very poor. This includes a severely limited ability of CI patients to make use of interaural time difference (ITD) cues for spatial hearing and noise reduction. A major cause for this poor ITD sensitivity could be that current clinical devices fail to deliver ITD information in a manner that is accessible to the auditory pathway. CI processors measure the envelopes of incoming sounds and then stimulate the auditory nerve with electrical pulse trains which are amplitude modulated to reflect incoming sound envelopes. The timing of the pulses generated by the devices is largely or entirely independent of the incoming sounds. Consequently, bilateral CIs (biCIs) provide veridical envelope (ENV) ITDs but largely or entirely replace the “fine structure” ITDs that naturally occur in sounds with completely arbitrary electrical pulse timing (PT) ITDs. To assess the extent to which this matters, we devised experiments that measured the sensitivity of deafened rats to precisely and independently controlled PT and ENV ITDs for a variety of different CI pulse rates and envelope shapes. We observed that PT ITDs completely dominate ITD perception, while the sensitivity to ENV ITDs was almost negligible in comparison. This strongly suggests that the confusing yet powerful PT ITDs that contemporary clinical devices deliver to biCI patients may be a major cause of poor binaural hearing outcomes with biCIs. Significance Statement: CIs deliver spectro-temporal envelopes, including speech formants, to severely deaf patients, but they do little to cater to the brain’s ability to process temporal sound features with sub-millisecond precision. CIs “sample” sound envelope signals rapidly and accurately, and thus provide information which should make it possible in principle for CI listeners to detect envelope ITDs in a similar way to normal listeners. However, here we demonstrate through behavioral experiments on CI implanted rats trained to detect sub-millisecond ITDs that pulse timing ITDs completely dominate binaural hearing. This provides the strongest confirmation to date that the arbitrary pulse timing widely used in current clinical CIs is a critical obstacle to good binaural hearing through prosthetic devices.
Open AccessIs Inappropriate Pulse Timing Responsible for Poor Binaural Hearing with Cochlear Implants?
Cochlear implants (CIs) have restored enough of a sense of hearing to around one million severely hearing impaired patients to enable speech understanding in quiet. However, several aspects of hearing with CIs remain very poor. This includes a severely limited ability of CI patients to make use of interaural time difference (ITD) cues for spatial hearing and noise reduction. A major cause for this poor ITD sensitivity could be that current clinical devices fail to deliver ITD information in a manner that is accessible to the auditory pathway. CI processors measure the envelopes of incoming sounds and then stimulate the auditory nerve with electrical pulse trains which are amplitude modulated to reflect incoming sound envelopes. The timing of the pulses generated by the devices is largely or entirely independent of the incoming sounds. Consequently, bilateral CIs (biCIs) provide veridical envelope (ENV) ITDs but largely or entirely replace the “fine structure” ITDs that naturally occur in sounds with completely arbitrary electrical pulse timing (PT) ITDs. To assess the extent to which this matters, we devised experiments that measured the sensitivity of deafened rats to precisely and independently controlled PT and ENV ITDs for a variety of different CI pulse rates and envelope shapes. We observed that PT ITDs completely dominate ITD perception, while the sensitivity to ENV ITDs was almost negligible in comparison. This strongly suggests that the confusing yet powerful PT ITDs that contemporary clinical devices deliver to biCI patients may be a major cause of poor binaural hearing outcomes with biCIs. Significance Statement: CIs deliver spectro-temporal envelopes, including speech formants, to severely deaf patients, but they do little to cater to the brain’s ability to process temporal sound features with sub-millisecond precision. CIs “sample” sound envelope signals rapidly and accurately, and thus provide information which should make it possible in principle for CI listeners to detect envelope ITDs in a similar way to normal listeners. However, here we demonstrate through behavioral experiments on CI implanted rats trained to detect sub-millisecond ITDs that pulse timing ITDs completely dominate binaural hearing. This provides the strongest confirmation to date that the arbitrary pulse timing widely used in current clinical CIs is a critical obstacle to good binaural hearing through prosthetic devices.
- Open Access
Interaural time difference sensitivity under binaural cochlear implant stimulation persists at high pulse rates up to 900 pps
Background: Spatial hearing remains one of the major challenges for bilateral cochlear implant (biCI) users, and early deaf patients in particular are often completely insensitive to interaural time differences (ITDs) delivered through biCIs. One popular hypothesis is that this may be due to a lack of early binaural experience. However, we have recently shown that neonatally deafened rats fitted with biCIs in adulthood quickly learn to discriminate ITDs as well as their normal hearing litter mates, and perform an order of magnitude better than human biCI users. Methods: Our unique behaving biCI rat model allows us to investigate other possible limiting factors of prosthetic binaural hearing, such as the effect of stimulus pulse rate and envelope shape. Previous work has indicated that ITD sensitivity may decline substantially at the high pulse rates often used in clinical practice. We therefore measured behavioral ITD thresholds in neonatally deafened, adult implanted biCI rats to pulse trains of 50, 300, 900 and 1800 pulses per second (pps), with either rectangular or Hanning window envelopes. Results: Our rats exhibited very high sensitivity to ITDs at pulse rates up to 900 pps for both envelope shapes, similar to those in common clinical use. However, ITD sensitivity declined to near zero at 1800 pps, for both Hanning and rectangular windowed pulse trains. Conclusions: Current clinical cochlear implant (CI) processors are often set to pulse rates ≥900 pps, but ITD sensitivity in human CI listeners has been reported to decline sharply above ∼300 pps. Our results suggest that the relatively poor ITD sensitivity seen at >300 pps in human CI users may not reflect the hard upper limit of biCI ITD performance in the mammalian auditory pathway. Perhaps with training or better CI strategies good binaural hearing may be achievable at pulse rates high enough to allow good sampling of speech envelopes while delivering usable ITDs.
Open AccessInteraural time difference sensitivity under binaural cochlear implant stimulation persists at high pulse rates up to 900 pps
Background: Spatial hearing remains one of the major challenges for bilateral cochlear implant (biCI) users, and early deaf patients in particular are often completely insensitive to interaural time differences (ITDs) delivered through biCIs. One popular hypothesis is that this may be due to a lack of early binaural experience. However, we have recently shown that neonatally deafened rats fitted with biCIs in adulthood quickly learn to discriminate ITDs as well as their normal hearing litter mates, and perform an order of magnitude better than human biCI users. Methods: Our unique behaving biCI rat model allows us to investigate other possible limiting factors of prosthetic binaural hearing, such as the effect of stimulus pulse rate and envelope shape. Previous work has indicated that ITD sensitivity may decline substantially at the high pulse rates often used in clinical practice. We therefore measured behavioral ITD thresholds in neonatally deafened, adult implanted biCI rats to pulse trains of 50, 300, 900 and 1800 pulses per second (pps), with either rectangular or Hanning window envelopes. Results: Our rats exhibited very high sensitivity to ITDs at pulse rates up to 900 pps for both envelope shapes, similar to those in common clinical use. However, ITD sensitivity declined to near zero at 1800 pps, for both Hanning and rectangular windowed pulse trains. Conclusions: Current clinical cochlear implant (CI) processors are often set to pulse rates ≥900 pps, but ITD sensitivity in human CI listeners has been reported to decline sharply above ∼300 pps. Our results suggest that the relatively poor ITD sensitivity seen at >300 pps in human CI users may not reflect the hard upper limit of biCI ITD performance in the mammalian auditory pathway. Perhaps with training or better CI strategies good binaural hearing may be achievable at pulse rates high enough to allow good sampling of speech envelopes while delivering usable ITDs.
- 1 September 2021
- Published by Elsevier in Hearing Research
- Vol. 408, 108305
Sensitivity to interaural time differences in the inferior colliculus of cochlear implanted rats with or without hearing experience
- 1 September 2021
- Published by Elsevier in Hearing Research
- Vol. 408, 108305
Sensitivity to interaural time differences in the inferior colliculus of cochlear implanted rats with or without hearing experience
- Open Access
- 11 January 2021
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 10
Microsecond interaural time difference discrimination restored by cochlear implants after neonatal deafness
Spatial hearing in cochlear implant (CI) patients remains a major challenge, with many early deaf users reported to have no measurable sensitivity to interaural time differences (ITDs). Deprivation of binaural experience during an early critical period is often hypothesized to be the cause of this shortcoming. However, we show that neonatally deafened (ND) rats provided with precisely synchronized CI stimulation in adulthood can be trained to lateralize ITDs with essentially normal behavioral thresholds near 50 μs. Furthermore, comparable ND rats show high physiological sensitivity to ITDs immediately after binaural implantation in adulthood. Our result that ND-CI rats achieved very good behavioral ITD thresholds, while prelingually deaf human CI patients often fail to develop a useful sensitivity to ITD raises urgent questions concerning the possibility that shortcomings in technology or treatment, rather than missing input during early development, may be behind the usually poor binaural outcomes for current CI patients.
- 11 January 2021
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 10
Open AccessMicrosecond interaural time difference discrimination restored by cochlear implants after neonatal deafness
Spatial hearing in cochlear implant (CI) patients remains a major challenge, with many early deaf users reported to have no measurable sensitivity to interaural time differences (ITDs). Deprivation of binaural experience during an early critical period is often hypothesized to be the cause of this shortcoming. However, we show that neonatally deafened (ND) rats provided with precisely synchronized CI stimulation in adulthood can be trained to lateralize ITDs with essentially normal behavioral thresholds near 50 μs. Furthermore, comparable ND rats show high physiological sensitivity to ITDs immediately after binaural implantation in adulthood. Our result that ND-CI rats achieved very good behavioral ITD thresholds, while prelingually deaf human CI patients often fail to develop a useful sensitivity to ITD raises urgent questions concerning the possibility that shortcomings in technology or treatment, rather than missing input during early development, may be behind the usually poor binaural outcomes for current CI patients.
- Open Access
Microsecond Interaural Time Difference Discrimination Restored by Cochlear Implants After Neonatal Deafness
Cochlear implants (CIs) can restore a high degree of functional hearing in deaf patients however spatial hearing remains poor, with many early deaf CI users reported to have no measurable sensitivity to interaural time differences (ITDs) at all. Deprivation of binaural experience during an early critical period is often blamed for this shortcoming. However, we show that neonatally deafened rats provided with precisely synchronized CI stimulation in adulthood can be trained to localize ITDs with essentially normal behavioral thresholds near 50 μs. Furthermore, neonatally deaf rats show high physiological sensitivity to ITDs immediately after binaural implantation in adulthood. The fact that our neonatally deaf CI rats achieved very good behavioral ITD thresholds while prelingually deaf human CI patients usually fail to develop a useful sensitivity to ITD raises urgent questions about whether shortcomings in technology or treatment may be behind the usually poor binaural outcomes for current binaural CI patients.
Open AccessMicrosecond Interaural Time Difference Discrimination Restored by Cochlear Implants After Neonatal Deafness
Cochlear implants (CIs) can restore a high degree of functional hearing in deaf patients however spatial hearing remains poor, with many early deaf CI users reported to have no measurable sensitivity to interaural time differences (ITDs) at all. Deprivation of binaural experience during an early critical period is often blamed for this shortcoming. However, we show that neonatally deafened rats provided with precisely synchronized CI stimulation in adulthood can be trained to localize ITDs with essentially normal behavioral thresholds near 50 μs. Furthermore, neonatally deaf rats show high physiological sensitivity to ITDs immediately after binaural implantation in adulthood. The fact that our neonatally deaf CI rats achieved very good behavioral ITD thresholds while prelingually deaf human CI patients usually fail to develop a useful sensitivity to ITD raises urgent questions about whether shortcomings in technology or treatment may be behind the usually poor binaural outcomes for current binaural CI patients.