Cunling Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cunling Yan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Le Chang
Department of Clinical Laboratory, Peking University First Hospital, Beijing, China
3 shared publicationsZhiyan Li
Department of Clinical Laboratory, Peking University First Hospital, Beijing, China
3 shared publicationsHongying Wang
Department of Respiratory and Critical Care Medicine, The Affiliated Nanhua Hospital, Hengyang Medical School, University of South China, Hengyang City, China
2 shared publications- Jian Hu
The First Affiliated hospital of Xi’an Jiaotong University Department of clinical laboratory Xi’an, 710061
1 shared publication K X Sun
Department of Clinical Laboratory, Peking University First Hospital, Beijing 100034, China
1 shared publication- Li Ma
Department of Clinical Laboratory and Liver Diseases, The Second Hospital of Nanjing, Affiliated to Medical School of Southeast University, Nanjing, 210000, China
1 shared publication
Latest Publications
- 30 July 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (22) , 5001-5017
Development of commutable stabilizing control materials to improve external quality assessment of hemoglobin A1c assay
Conformational and colloidal stabilities are responsible for the stability of hemoglobin. However, most hemoglobin A1c (HbA1c) control materials (e.g., reference materials, calibrators, and quality control materials) are unstable and noncommutable. This may be closely related to the breakdown of the balance between the conformational and colloidal stabilities of hemoglobin. Therefore, we developed a new combined formulation buffer to address the causes of conformational and colloidal instabilities and to maintain hemoglobin or HbA1c stability. For the commutability of HbA1c control materials, we purified hemoglobin to remove plasma proteins, phospholipids, and fats. On the basis of the above design, we prepared two medical concentrations of HbA1c control materials for the external quality assessment (EQA) program and then determined the certified values via the reference measurement method. Stability, homogeneity, value transfer, and commutability were evaluated. Moreover, the control material was distributed to 56 laboratories to assess proficiency testing. The HbA1c control materials showed good homogeneity and stability and reliable value transfer, and were commutable for routine clinical analyzers. In the EQA program, only one analyzer exceeded the acceptable bias range (± 6.0%), and the mean interlaboratory CVs of the three analyzers exceeded the acceptable range (3.0%), which can be used to assess true values to improve proficiency testing in the EQA program. Therefore, newly developed control materials can be used to standardize the determination of HbA1c. Graphical Abstract
- 30 July 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (22) , 5001-5017
Development of commutable stabilizing control materials to improve external quality assessment of hemoglobin A1c assay
Conformational and colloidal stabilities are responsible for the stability of hemoglobin. However, most hemoglobin A1c (HbA1c) control materials (e.g., reference materials, calibrators, and quality control materials) are unstable and noncommutable. This may be closely related to the breakdown of the balance between the conformational and colloidal stabilities of hemoglobin. Therefore, we developed a new combined formulation buffer to address the causes of conformational and colloidal instabilities and to maintain hemoglobin or HbA1c stability. For the commutability of HbA1c control materials, we purified hemoglobin to remove plasma proteins, phospholipids, and fats. On the basis of the above design, we prepared two medical concentrations of HbA1c control materials for the external quality assessment (EQA) program and then determined the certified values via the reference measurement method. Stability, homogeneity, value transfer, and commutability were evaluated. Moreover, the control material was distributed to 56 laboratories to assess proficiency testing. The HbA1c control materials showed good homogeneity and stability and reliable value transfer, and were commutable for routine clinical analyzers. In the EQA program, only one analyzer exceeded the acceptable bias range (± 6.0%), and the mean interlaboratory CVs of the three analyzers exceeded the acceptable range (3.0%), which can be used to assess true values to improve proficiency testing in the EQA program. Therefore, newly developed control materials can be used to standardize the determination of HbA1c. Graphical Abstract
- 28 March 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (14) , 3033-3045
Development of microprefilter for chromatography column in HbA1c assays
The complexity of blood and its matrix in high-performance liquid chromatography (HPLC) glycated hemoglobin (HbA1c) assays is closely related to column performance. However, the available prefilters with a single structure or surface membrane materials are not ideal for column protection, and coupled with the complexity of blood samples, leads to rapid degradation of column performance. Therefore, we have developed a new microprefilter with a three-stage filtration design and depth filter material to protect the column. All filter materials used in the preparation of microprefilters were characterized, screened, and optimized, and then manufactured on the basis of optimized filter materials, which are depth filter material microprefilters. Based on the material and structural design, microprefilters were capable of filtering particulate matter from test samples on a step-by-step basis to avoid the plugging effect that occurs when all sizes of substances are gathered together. Moreover, all newly developed microprefilters can be tested more times, up to 600 times. Microprefilters with small-pore-size final filtration membranes of polyethersulfone, hydrophilic polytetrafluoroethylene, and mixed cellulose showed excellent column protection in terms of column efficiency, HbA1c retention time, number of column tests, and column backpressure, and prolonged column lifetime by as much as 20–30% compared with microprefilters with large-pore-size final membranes. Our study provides valuable depth filter material microprefilters with multistage filtration for chromatography columns, and showed excellent column protection and prolonged column lifetime. Meanwhile, microprefilters can be tested more times. The newly developed microprefilters with a small-pore-size final membrane are the optimal choice for column protection of the HbA1c assay.
- 28 March 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (14) , 3033-3045
Development of microprefilter for chromatography column in HbA1c assays
The complexity of blood and its matrix in high-performance liquid chromatography (HPLC) glycated hemoglobin (HbA1c) assays is closely related to column performance. However, the available prefilters with a single structure or surface membrane materials are not ideal for column protection, and coupled with the complexity of blood samples, leads to rapid degradation of column performance. Therefore, we have developed a new microprefilter with a three-stage filtration design and depth filter material to protect the column. All filter materials used in the preparation of microprefilters were characterized, screened, and optimized, and then manufactured on the basis of optimized filter materials, which are depth filter material microprefilters. Based on the material and structural design, microprefilters were capable of filtering particulate matter from test samples on a step-by-step basis to avoid the plugging effect that occurs when all sizes of substances are gathered together. Moreover, all newly developed microprefilters can be tested more times, up to 600 times. Microprefilters with small-pore-size final filtration membranes of polyethersulfone, hydrophilic polytetrafluoroethylene, and mixed cellulose showed excellent column protection in terms of column efficiency, HbA1c retention time, number of column tests, and column backpressure, and prolonged column lifetime by as much as 20–30% compared with microprefilters with large-pore-size final membranes. Our study provides valuable depth filter material microprefilters with multistage filtration for chromatography columns, and showed excellent column protection and prolonged column lifetime. Meanwhile, microprefilters can be tested more times. The newly developed microprefilters with a small-pore-size final membrane are the optimal choice for column protection of the HbA1c assay.
- 1 January 2024
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 70 (04/2024) , 670-680
Performance Evaluation of Newly-Developed Tumor Markers Assay Kit Based on Flow Fluorescence Assay
Background: The purpose of this study is to evaluate the performance of recently developed tumor marker clinical kits in China, with the aim of encouraging local medical technology innovation and thus narrowing the research and development gap with foreign kits. Methods: The newly established reagent kits were analyzed on the TESMI F3999-Luminex200 flow lattice instrument to verify precision, sensitivity (blank limit), linearity, anti-interference ability, carry-over contamination rate, hook effect, and reference interval verification. Additionally, the newly established reagent kits were compared to other commercially available detection kits (reference reagent kits) to analyze the correlation between the two types of kits. Results: The intra-assay and inter-assay precision had coefficients of variations (CVs) less than 3.50% and 6.91%, respectively. The tumor marker blank limits were lower than the manufacturer's statement. The newly established reagent kits demonstrated excellent linearity (r > 0.99). Rheumatoid factor, triglycerides, bilirubin, and hemoglobin did not have significant interference with the determination of tumor markers. The carry-over contamination rates were all much lower than 3%. At extremely high concentrations of AFP (277,335 ng/mL and 1,031,424 ng/mL), the measured tumor marker values were higher than the upper limit of the linear range and no hook effect occurred. The reference interval was suitable for use in clinical laboratory settings. Correlation analysis indicated a satisfactory relevance and consistency between the newly developed reagent kits and reference reagent kits, with correlation coefficients of r > 0.967 among 654 patients and healthy individuals. Conclusions: The newly developed reagent kits for tumor markers performed well in all evaluated parameters, having the potential for clinical promotion and application.
- 1 January 2024
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 70 (04/2024) , 670-680
Performance Evaluation of Newly-Developed Tumor Markers Assay Kit Based on Flow Fluorescence Assay
Background: The purpose of this study is to evaluate the performance of recently developed tumor marker clinical kits in China, with the aim of encouraging local medical technology innovation and thus narrowing the research and development gap with foreign kits. Methods: The newly established reagent kits were analyzed on the TESMI F3999-Luminex200 flow lattice instrument to verify precision, sensitivity (blank limit), linearity, anti-interference ability, carry-over contamination rate, hook effect, and reference interval verification. Additionally, the newly established reagent kits were compared to other commercially available detection kits (reference reagent kits) to analyze the correlation between the two types of kits. Results: The intra-assay and inter-assay precision had coefficients of variations (CVs) less than 3.50% and 6.91%, respectively. The tumor marker blank limits were lower than the manufacturer's statement. The newly established reagent kits demonstrated excellent linearity (r > 0.99). Rheumatoid factor, triglycerides, bilirubin, and hemoglobin did not have significant interference with the determination of tumor markers. The carry-over contamination rates were all much lower than 3%. At extremely high concentrations of AFP (277,335 ng/mL and 1,031,424 ng/mL), the measured tumor marker values were higher than the upper limit of the linear range and no hook effect occurred. The reference interval was suitable for use in clinical laboratory settings. Correlation analysis indicated a satisfactory relevance and consistency between the newly developed reagent kits and reference reagent kits, with correlation coefficients of r > 0.967 among 654 patients and healthy individuals. Conclusions: The newly developed reagent kits for tumor markers performed well in all evaluated parameters, having the potential for clinical promotion and application.
- 18 April 2020
- Vol. 52 (2) , 234-239
前列腺特异性抗原同源异构体2及其衍生指标在预测前列腺癌病理分级中的价值
探讨血清前列腺特异性抗原同源异构体2(isoform [-2] proprostate-specific antigen,p2PSA)及经计算得到的%p2PSA和前列腺健康指数(prostate health index,PHI)等指标预测前列腺癌(prostate cancer, PCa)病理分级的价值. 回顾性入组了322例来自北京大学第一医院在2015年8月至2018年5月期间就诊的PCa患者,其中143例为进行经直肠超声引导的前列腺穿刺活检证实的PCa患者,179例为进行PCa根治术的患者.采用全自动免疫分析仪DxI800检测患者的术前预留血清中前列腺特异性抗原(total prostate-specific antigen,tPSA),游离前列腺抗原(free prostate antigen,fPSA),fPSA/tPSA比值(f/t),p2PSA水平,并计算得到%p2PSA 和PHI,以术后病理结果确定Gleason评分,采用受试者工作曲线(receiver operating characteristic curve,ROC)比较p2PSA,%p2PSA及PHI与传统指标tPSA,fPSA和f/t预测高级别前列腺癌(Gleason评分≥7)的价值. Gleason评分≥7患者的p2PSA,%p2PSA和 PHI的中位数水平均高于Gleason评分<7患者(p2PSA: 30.22 ng/L vs. 18.33 ng/L; %p2PSA: 2.50 vs. 1.27; PHI: 91.81 vs. 35.44; P值均<0.01).%p2PSA和PHI预测高级别PCa的曲线下面积(area under curve,AUC)为0.770和0.760,高于传统指标tPSA,fPSA和f/t(AUC分别为0.648,0.536和 0.693).进行前列腺穿刺术证实为PCa的患者中,PHI和%p2PSA预测高级别PCa的价值(AUC分别为0.801和0.808)明显高于tPSA,fPSA和f/t(AUC分别为0.729,0.655和0.665).进行PCa根治术后的患者中,PHI 和%p2PSA预测高级别PCa的价值(AUC分别为 0.798和0.744)也有高于其他传统指标tPSA,fPSA和f/t (AUC分别为0.625, 0.507和0.697)的趋势. 与传统指标tPSA,fPSA和f/t相比,p2PSA的衍生指标%p2PSA和PHI对于高级别PCa具有更高的预测价值,可以帮助临床评估PCa治疗方案,为患者及时制定更合适的诊疗策略.
- 18 April 2020
- Vol. 52 (2) , 234-239
前列腺特异性抗原同源异构体2及其衍生指标在预测前列腺癌病理分级中的价值
探讨血清前列腺特异性抗原同源异构体2(isoform [-2] proprostate-specific antigen,p2PSA)及经计算得到的%p2PSA和前列腺健康指数(prostate health index,PHI)等指标预测前列腺癌(prostate cancer, PCa)病理分级的价值. 回顾性入组了322例来自北京大学第一医院在2015年8月至2018年5月期间就诊的PCa患者,其中143例为进行经直肠超声引导的前列腺穿刺活检证实的PCa患者,179例为进行PCa根治术的患者.采用全自动免疫分析仪DxI800检测患者的术前预留血清中前列腺特异性抗原(total prostate-specific antigen,tPSA),游离前列腺抗原(free prostate antigen,fPSA),fPSA/tPSA比值(f/t),p2PSA水平,并计算得到%p2PSA 和PHI,以术后病理结果确定Gleason评分,采用受试者工作曲线(receiver operating characteristic curve,ROC)比较p2PSA,%p2PSA及PHI与传统指标tPSA,fPSA和f/t预测高级别前列腺癌(Gleason评分≥7)的价值. Gleason评分≥7患者的p2PSA,%p2PSA和 PHI的中位数水平均高于Gleason评分<7患者(p2PSA: 30.22 ng/L vs. 18.33 ng/L; %p2PSA: 2.50 vs. 1.27; PHI: 91.81 vs. 35.44; P值均<0.01).%p2PSA和PHI预测高级别PCa的曲线下面积(area under curve,AUC)为0.770和0.760,高于传统指标tPSA,fPSA和f/t(AUC分别为0.648,0.536和 0.693).进行前列腺穿刺术证实为PCa的患者中,PHI和%p2PSA预测高级别PCa的价值(AUC分别为0.801和0.808)明显高于tPSA,fPSA和f/t(AUC分别为0.729,0.655和0.665).进行PCa根治术后的患者中,PHI 和%p2PSA预测高级别PCa的价值(AUC分别为 0.798和0.744)也有高于其他传统指标tPSA,fPSA和f/t (AUC分别为0.625, 0.507和0.697)的趋势. 与传统指标tPSA,fPSA和f/t相比,p2PSA的衍生指标%p2PSA和PHI对于高级别PCa具有更高的预测价值,可以帮助临床评估PCa治疗方案,为患者及时制定更合适的诊疗策略.
- Open Access
- 13 December 2018
- Published by Springer Nature in BMC Gastroenterology
- Vol. 18 (1) , 1-7
Diagnostic value of alpha-fetoprotein combined with neutrophil-to-lymphocyte ratio for hepatocellular carcinoma
To investigate the diagnostic performance of alpha-fetoprotein (AFP) and neutrophil-to-lymphocyte ratio (NLR) as well as their combinations with other markers. Serum aspartate aminotransferase (AST), alanine aminotransferase (ALT), AFP and levels as well as the numbers of neutrophils and lymphocytes of all enrolled patients were collected. The NLR was calculated by dividing the number of neutrophils by the number of lymphocytes. Receiver operating characteristic (ROC) curve analysis was conducted to determine the ability of each marker and combination of markers to distinguish HCC and liver disease patients. In total, 545 patients were included in this study. The area under the ROC curve (AUC) values for AFP, ALT, AST, and NLR were 0.775 (0.738–0.810), 0.504 (0.461–0.547), 0.660 (0.618–0.699), and 0.738 (0.699–0.774) with optimal cut-off values of 24.6 ng/mL, 111 IU/mL, 27 IU/mL, and 2.979, respectively. Of the four biomarkers, AFP and NLR showed comparable specificity (0.881 and 0.858) and sensitivity (0.561 and 0.539). The combination of AFP and NLR showed the highest AUC (0.769) with a significantly higher sensitivity (0.767) and a lower specificity (0.773) compared to AFP or NLR alone, and it had the highest sum of sensitivity and specificity (1.54) among all combinations. In patients with AFP < 20 ng/mL, the NLR showed the highest AUC and combination with other markers did not improve the diagnostic accuracy. Our data indicate that the combination of AFP and NLR offers better diagnostic performance than either marker alone for differentiating HCC from liver disease, which may benefit clinical screening.
- 13 December 2018
- Published by Springer Nature in BMC Gastroenterology
- Vol. 18 (1) , 1-7
Open AccessDiagnostic value of alpha-fetoprotein combined with neutrophil-to-lymphocyte ratio for hepatocellular carcinoma
To investigate the diagnostic performance of alpha-fetoprotein (AFP) and neutrophil-to-lymphocyte ratio (NLR) as well as their combinations with other markers. Serum aspartate aminotransferase (AST), alanine aminotransferase (ALT), AFP and levels as well as the numbers of neutrophils and lymphocytes of all enrolled patients were collected. The NLR was calculated by dividing the number of neutrophils by the number of lymphocytes. Receiver operating characteristic (ROC) curve analysis was conducted to determine the ability of each marker and combination of markers to distinguish HCC and liver disease patients. In total, 545 patients were included in this study. The area under the ROC curve (AUC) values for AFP, ALT, AST, and NLR were 0.775 (0.738–0.810), 0.504 (0.461–0.547), 0.660 (0.618–0.699), and 0.738 (0.699–0.774) with optimal cut-off values of 24.6 ng/mL, 111 IU/mL, 27 IU/mL, and 2.979, respectively. Of the four biomarkers, AFP and NLR showed comparable specificity (0.881 and 0.858) and sensitivity (0.561 and 0.539). The combination of AFP and NLR showed the highest AUC (0.769) with a significantly higher sensitivity (0.767) and a lower specificity (0.773) compared to AFP or NLR alone, and it had the highest sum of sensitivity and specificity (1.54) among all combinations. In patients with AFP < 20 ng/mL, the NLR showed the highest AUC and combination with other markers did not improve the diagnostic accuracy. Our data indicate that the combination of AFP and NLR offers better diagnostic performance than either marker alone for differentiating HCC from liver disease, which may benefit clinical screening.