Quan Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Quan Jiang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Yuan Zhang
Department of Ultrasound, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
5 shared publicationsShu-Hao Deng
Department of Ultrasound, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
4 shared publicationsJun Shan
Department of Ultrasound, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
3 shared publicationsYi-Cheng Zhu
Department of Ultrasound, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
3 shared publicationsDao-Ming Zu
Department of Pediatrics, Pudong New Area People’s Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
2 shared publicationsLi Zhou
Department of Ultrasound, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 23 December 2024
- Published by SAGE Publications in Clinical Hemorheology and Microcirculation
- Vol. 88 (4) , 443-454
Clinical applications of superb microvascular imaging and virtual touch imaging quantification in pediatric mesenteric lymphadenitis diagnosis: A promising pathway to enhanced precision
BACKGROUND: Mesenteric lymphadenitis (ML) demonstrates a distinctive inclination for the pediatric and adolescent demographic and the diagnosis of ML in young children poses a substantial challenge. OBJECTIVE: This prospective study aimed to assess the diagnostic efficacy of Superb Microvascular Imaging (SMI) and Virtual Touch Tissue Imaging quantification (VTIQ) in distinguishing pediatric mesenteric lymphadentitis. METHODS: We examined 82 mesentric lymph node (MLN) in pediatric patients with mesenteric lymphadentitis and 50 MLN in a healthy group. SMI was utilized to evaluate vascularity within the MLN, while MLN stiffness, quantified as shear wave velocity (SWV) in meters per second (m/s), was assessed using VTIQ. We compared the diagnostic performance of greyscale Ultrasound, US combined with SMI, US combined with VTIQ, and US combined with both SMI and VTIQ. RESULTS: SMI revealed a significant distinction between mesenteric lymphadentitis and normal MLN ( p < 0.001). MLN affected by mesenteric lymphadentis exhibited increased vascularity (marked vascularity: 13/82, 15.85%) compared to normal MLN (marked vascularity: 1/50, 2.00%). Statistically significant differences were observed in SWV values beween mesenteric lymphadentitis and normal MLN (all p-values <0.001). The mean and minimum SWV values for MLN with mesenteric lymphadentitis were 1.66±0.77 m/s and 1.51±0.53 m/s, respectively. Control group SWV values were approximately three times higher than those in the mesenteric lymphadenitis group. The highest area under the curve values were achieved with the combination of all three modalities (0.837, 95% confidence interval: 0.763– 0.896), followed by US + VTIQ (0.795, 0.716– 0.860), US + SMI (0.753, 0.670– 0.824) and US alone (0.642, 0.554– 0.724). CONCLUSION: SMI and VTIQ offer a promising noninvasive adjunct to grayscale ultrasound for identifying mesenteric lymphadentitis in pediatric patients.
- 23 December 2024
- Published by SAGE Publications in Clinical Hemorheology and Microcirculation
- Vol. 88 (4) , 443-454
Open AccessClinical applications of superb microvascular imaging and virtual touch imaging quantification in pediatric mesenteric lymphadenitis diagnosis: A promising pathway to enhanced precision
BACKGROUND: Mesenteric lymphadenitis (ML) demonstrates a distinctive inclination for the pediatric and adolescent demographic and the diagnosis of ML in young children poses a substantial challenge. OBJECTIVE: This prospective study aimed to assess the diagnostic efficacy of Superb Microvascular Imaging (SMI) and Virtual Touch Tissue Imaging quantification (VTIQ) in distinguishing pediatric mesenteric lymphadentitis. METHODS: We examined 82 mesentric lymph node (MLN) in pediatric patients with mesenteric lymphadentitis and 50 MLN in a healthy group. SMI was utilized to evaluate vascularity within the MLN, while MLN stiffness, quantified as shear wave velocity (SWV) in meters per second (m/s), was assessed using VTIQ. We compared the diagnostic performance of greyscale Ultrasound, US combined with SMI, US combined with VTIQ, and US combined with both SMI and VTIQ. RESULTS: SMI revealed a significant distinction between mesenteric lymphadentitis and normal MLN ( p < 0.001). MLN affected by mesenteric lymphadentis exhibited increased vascularity (marked vascularity: 13/82, 15.85%) compared to normal MLN (marked vascularity: 1/50, 2.00%). Statistically significant differences were observed in SWV values beween mesenteric lymphadentitis and normal MLN (all p-values <0.001). The mean and minimum SWV values for MLN with mesenteric lymphadentitis were 1.66±0.77 m/s and 1.51±0.53 m/s, respectively. Control group SWV values were approximately three times higher than those in the mesenteric lymphadenitis group. The highest area under the curve values were achieved with the combination of all three modalities (0.837, 95% confidence interval: 0.763– 0.896), followed by US + VTIQ (0.795, 0.716– 0.860), US + SMI (0.753, 0.670– 0.824) and US alone (0.642, 0.554– 0.724). CONCLUSION: SMI and VTIQ offer a promising noninvasive adjunct to grayscale ultrasound for identifying mesenteric lymphadentitis in pediatric patients.
- Open Access
- 23 April 2024
- Published by Spandidos Publications in Experimental and Therapeutic Medicine
- Vol. 27 (6) , 1-8
Value of conventional ultrasound and shear‑wave elastography in the assessment of mesenteric lymphadenitis in a paediatric population
The present retrospective study was designed to explore the value of conventional ultrasound (US) and Virtual Touch Tissue Imaging and Quantification (VTIQ) in the assessment of mesenteric lymphadenitis (ML) in a paediatric population. A total of 103 patients with ML and 60 healthy paediatric patients were examined. VTIQ was performed to assess mesenteric lymph node (MLN) stiffness via shear‑wave velocity (SWV). Univariate and multivariate logistic regression analyses were conducted to reveal independent variables for the identification of ML. The diagnostic performance of US, and US combined with VTIQ, were compared. All the quantitative VTIQ parameters (including the SWVMean, SWVMax and SWVMin) were significantly greater for MLNs in the control group than for MLNs in the ML group (all PMean (OR=0.106; P<0.001). According to the receiver operating characteristic analysis, the area under the curve (AUC) for US combined with VTIQ was 0.890 (95% CI: 0.831‑0.949) with a greater sensitivity of 91.26% and a greater specificity of 86.67% than that for US alone (AUC: 0.798; 95% CI: 0.724‑0.872; sensitivity: 79.61%; specificity: 80.00%). A significant negative correlation between increased VTIQ parameters and ML was observed. Utilizing VTIQ to assess MLN stiffness offers a non‑invasive, convenient, reliable and reproducible approach for identifying mesenteric lymphadenopathy.
- 23 April 2024
- Published by Spandidos Publications in Experimental and Therapeutic Medicine
- Vol. 27 (6) , 1-8
Open AccessValue of conventional ultrasound and shear‑wave elastography in the assessment of mesenteric lymphadenitis in a paediatric population
The present retrospective study was designed to explore the value of conventional ultrasound (US) and Virtual Touch Tissue Imaging and Quantification (VTIQ) in the assessment of mesenteric lymphadenitis (ML) in a paediatric population. A total of 103 patients with ML and 60 healthy paediatric patients were examined. VTIQ was performed to assess mesenteric lymph node (MLN) stiffness via shear‑wave velocity (SWV). Univariate and multivariate logistic regression analyses were conducted to reveal independent variables for the identification of ML. The diagnostic performance of US, and US combined with VTIQ, were compared. All the quantitative VTIQ parameters (including the SWVMean, SWVMax and SWVMin) were significantly greater for MLNs in the control group than for MLNs in the ML group (all PMean (OR=0.106; P<0.001). According to the receiver operating characteristic analysis, the area under the curve (AUC) for US combined with VTIQ was 0.890 (95% CI: 0.831‑0.949) with a greater sensitivity of 91.26% and a greater specificity of 86.67% than that for US alone (AUC: 0.798; 95% CI: 0.724‑0.872; sensitivity: 79.61%; specificity: 80.00%). A significant negative correlation between increased VTIQ parameters and ML was observed. Utilizing VTIQ to assess MLN stiffness offers a non‑invasive, convenient, reliable and reproducible approach for identifying mesenteric lymphadenopathy.
- Open Access
- 11 July 2019
- Published by Spandidos Publications in Oncology Letters
- Vol. 18 (3) , 3202-3210
A comparative study on superb microvascular imaging and conventional ultrasonography in differentiating BI‑RADS 4 breast lesions
This prospective study aimed to explore the diagnostic value of superb microvascular imaging (SMI) in differentiating Breast Imaging Reporting and Data System (BI‑RADS) 4 breast lesions compared with conventional ultrasonography (US). A total of 111 patients with 116 breast lesions underwent grayscale ultrasound (US), colour Doppler flow imaging (CDFI) and SMI breast imaging between February 2016 and May 2018. CDFI and SMI were performed to evaluate vascular quantity, morphology, and distribution characteristics. The detection of malignancy was compared between grayscale US alone, US + CDFI and US + SMI in terms of the BI‑RADS stratification system. SMI was observed to be significantly more accurate in distinguishing malignant breast lesions (86.67%) compared with CDFI (80.00%) (P<0.001). Among malignant lesions, SMI detected 80.00% of those that contained ≥4 vessels, while CDFI only detected 56.67%. Penetrating and branching vessels were identified by SMI in 53.33% of malignant breast lesions and by CDFI in 10.00%. There was no significant difference in vascular distribution by SMI (P=0.094) and by CDFI (P=0.087). US + SMI was associated with higher sensitivity, specificity, and accuracy rates (86.67, 83.72 and 84.48%, respectively) compared with US + CDFI (80.00, 72.09 and 74.14%, respectively). The area under the curve values from receiver operating characteristic analysis of US + SMI, US + CDFI and US alone were 0.852 [95% confidence interval (CI): 0.768‑0.936)] 0.760 (95% CI: 0.660‑0.860), 0.698 (95% CI: 0.589‑0.807), respectively (P<0.001). SMI yielded more detailed vascular information associated with malignant breast masses when compared with conventional US. Therefore, as an adjunct to grayscale, SMI exhibited a markedly improved diagnostic capability in distinguishing malignant and benign breast lesions, particularly those of BI‑RADS category 4.
- 11 July 2019
- Published by Spandidos Publications in Oncology Letters
- Vol. 18 (3) , 3202-3210
Open AccessA comparative study on superb microvascular imaging and conventional ultrasonography in differentiating BI‑RADS 4 breast lesions
This prospective study aimed to explore the diagnostic value of superb microvascular imaging (SMI) in differentiating Breast Imaging Reporting and Data System (BI‑RADS) 4 breast lesions compared with conventional ultrasonography (US). A total of 111 patients with 116 breast lesions underwent grayscale ultrasound (US), colour Doppler flow imaging (CDFI) and SMI breast imaging between February 2016 and May 2018. CDFI and SMI were performed to evaluate vascular quantity, morphology, and distribution characteristics. The detection of malignancy was compared between grayscale US alone, US + CDFI and US + SMI in terms of the BI‑RADS stratification system. SMI was observed to be significantly more accurate in distinguishing malignant breast lesions (86.67%) compared with CDFI (80.00%) (P<0.001). Among malignant lesions, SMI detected 80.00% of those that contained ≥4 vessels, while CDFI only detected 56.67%. Penetrating and branching vessels were identified by SMI in 53.33% of malignant breast lesions and by CDFI in 10.00%. There was no significant difference in vascular distribution by SMI (P=0.094) and by CDFI (P=0.087). US + SMI was associated with higher sensitivity, specificity, and accuracy rates (86.67, 83.72 and 84.48%, respectively) compared with US + CDFI (80.00, 72.09 and 74.14%, respectively). The area under the curve values from receiver operating characteristic analysis of US + SMI, US + CDFI and US alone were 0.852 [95% confidence interval (CI): 0.768‑0.936)] 0.760 (95% CI: 0.660‑0.860), 0.698 (95% CI: 0.589‑0.807), respectively (P<0.001). SMI yielded more detailed vascular information associated with malignant breast masses when compared with conventional US. Therefore, as an adjunct to grayscale, SMI exhibited a markedly improved diagnostic capability in distinguishing malignant and benign breast lesions, particularly those of BI‑RADS category 4.
- 1 March 2019
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 28 (3) , 830-837
Evaluating the Efficacy of Atorvastatin on Patients with Carotid Plaque by an Innovative Ultrasonography
- 1 March 2019
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 28 (3) , 830-837
Evaluating the Efficacy of Atorvastatin on Patients with Carotid Plaque by an Innovative Ultrasonography
- 26 August 2018
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 24, 5935-5942
Diagnostic Performance of Superb Microvascular Imaging (SMI) Combined with Shear-Wave Elastography in Evaluating Breast Lesions
BACKGROUND:This study explored the diagnostic value of a combined modality of Superb Microvascular Imaging (SMI) and shear-wave elastography in differentiating malignant and benign breast lesions. MATERIAL AND METHODS:A total of 121 patients with 123...
- 26 August 2018
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 24, 5935-5942
Diagnostic Performance of Superb Microvascular Imaging (SMI) Combined with Shear-Wave Elastography in Evaluating Breast Lesions
BACKGROUND:This study explored the diagnostic value of a combined modality of Superb Microvascular Imaging (SMI) and shear-wave elastography in differentiating malignant and benign breast lesions. MATERIAL AND METHODS:A total of 121 patients with 123...