Nuno Lemos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nuno Lemos has a total of 583 co-authors. Here are the top co-authors by number of shared publications:
A. Pak
Lawrence Livermore National Laboratory 2 , Livermore, California 94550
11 shared publicationsF. Albert
Lawrence Livermore National Laboratory (LLNL)
8 shared publicationsP. Michel
Lawrence Livermore National Laboratory, Livermore, CA, United States of America
8 shared publications- Andreas J. Kemp
Lawrence Livermore National Laboratory , Livermore, California 94550
7 shared publications - Gerald Jackson Williams
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
7 shared publications - Hui Chen
Lawrence Livermore National Laboratory
7 shared publications
Latest Publications
- 1 August 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (8)
Modeling stimulated Brillouin backscatter from the inner laser cones during indirect-drive inertial confinement fusion experiments at the National Ignition Facility
We report progress modeling stimulated Brillouin scatter (SBS) at the National Ignition Facility (NIF). For indirect-drive, ignition-relevant hohlraum experiments, backward SBS light is a long-standing concern due to its potential for damaging laser optics as well as affecting the symmetry of the x-ray field that drives capsule implosions. To model SBS, we use maps of underdense plasma conditions, i.e., temperatures, densities, materials, charge states, and flows, from hydrodynamics simulations of the hohlraum to run backscatter simulations with the code pF3D [Berger et al., Phys. Plasmas 26, 012709 (2019)]; the latter calculates propagation of incident- and backscattered light of a NIF quad in the paraxial approximation. For the inner cone quads, in designs that utilize significant wavelength detuning, i.e., those that use cross-beam energy transfer to control implosion symmetry, this approach typically has overestimated both the peak power and the duration of SBS measured in experiments. In this work, we discuss how multi-species hydrodynamics simulations can lead to better agreement with experiments through changes to the simulated plasma conditions and the resulting SBS growth rates. Specifically, we discuss SBS reflectivity in the 23° and 30° inner cone quads, compare simulated spectra to FABS measured ones, and discuss how the time history of the backscattered light is related to the absorption/refraction of the incoming light off density features in the hohlraum plasma.
- 1 August 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (8)
Modeling stimulated Brillouin backscatter from the inner laser cones during indirect-drive inertial confinement fusion experiments at the National Ignition Facility
We report progress modeling stimulated Brillouin scatter (SBS) at the National Ignition Facility (NIF). For indirect-drive, ignition-relevant hohlraum experiments, backward SBS light is a long-standing concern due to its potential for damaging laser optics as well as affecting the symmetry of the x-ray field that drives capsule implosions. To model SBS, we use maps of underdense plasma conditions, i.e., temperatures, densities, materials, charge states, and flows, from hydrodynamics simulations of the hohlraum to run backscatter simulations with the code pF3D [Berger et al., Phys. Plasmas 26, 012709 (2019)]; the latter calculates propagation of incident- and backscattered light of a NIF quad in the paraxial approximation. For the inner cone quads, in designs that utilize significant wavelength detuning, i.e., those that use cross-beam energy transfer to control implosion symmetry, this approach typically has overestimated both the peak power and the duration of SBS measured in experiments. In this work, we discuss how multi-species hydrodynamics simulations can lead to better agreement with experiments through changes to the simulated plasma conditions and the resulting SBS growth rates. Specifically, we discuss SBS reflectivity in the 23° and 30° inner cone quads, compare simulated spectra to FABS measured ones, and discuss how the time history of the backscattered light is related to the absorption/refraction of the incoming light off density features in the hohlraum plasma.
- 1 July 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (7)
Tomography of an inertial confinement fusion fuel capsule using betatron x-rays from a laser wakefield accelerator
Ultrafast x-ray pulses from laser–plasma interactions have the potential to diagnose inertial confinement fusion and other high energy density environments with high spatial and temporal resolution. We discuss a new application for laser wakefield acceleration betatron x-rays: computed tomography (CT) of inertial confinement fusion fuel capsules. Here, we use betatron x-rays of source size 1.8±1.5 μm and a broadband spectrum with a critical energy of 19±4 keV, subject to on-shot fluctuations. Absorption radiographs of a capsule were taken from 360 angles in 1° increments and reconstructed into a CT image volume.
- 1 July 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (7)
Tomography of an inertial confinement fusion fuel capsule using betatron x-rays from a laser wakefield accelerator
Ultrafast x-ray pulses from laser–plasma interactions have the potential to diagnose inertial confinement fusion and other high energy density environments with high spatial and temporal resolution. We discuss a new application for laser wakefield acceleration betatron x-rays: computed tomography (CT) of inertial confinement fusion fuel capsules. Here, we use betatron x-rays of source size 1.8±1.5 μm and a broadband spectrum with a critical energy of 19±4 keV, subject to on-shot fluctuations. Absorption radiographs of a capsule were taken from 360 angles in 1° increments and reconstructed into a CT image volume.
- 1 June 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (6)
Laser polarization effects on crossed-beam energy transfer in inertial confinement fusion
Crossed-beam energy transfer (CBET) is a consequential process in inertial confinement fusion (ICF) experiments. CBET depends on the polarization state of the interacting lasers and can, in turn, alter their polarization. We derive analytical expressions for two-beam CBET with linearly and circularly polarized light, and present simulations of CBET that include polarization effects for ICF conditions relevant to experiments on the National Ignition Facility. The results show that CBET mixes the polarization of the beams as they propagate through the target and leads to azimuthal power imbalances between beams within a given cone (i.e., at the same polar angle in the target chamber). These variations are shown to correlate with variations in measured backscatter between beams of a same quadruplet. Using circularly polarized, instead of linearly polarized, light produces similar overall levels of CBET within a cone of beams but tends to reduce the azimuthal variations. This is expected to slightly improve irradiation symmetry and reduce the risk of backscatter from stimulated Brillouin scattering. Circular polarization may therefore be beneficial for the next generation of laser fusion drivers.
- 1 June 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (6)
Laser polarization effects on crossed-beam energy transfer in inertial confinement fusion
Crossed-beam energy transfer (CBET) is a consequential process in inertial confinement fusion (ICF) experiments. CBET depends on the polarization state of the interacting lasers and can, in turn, alter their polarization. We derive analytical expressions for two-beam CBET with linearly and circularly polarized light, and present simulations of CBET that include polarization effects for ICF conditions relevant to experiments on the National Ignition Facility. The results show that CBET mixes the polarization of the beams as they propagate through the target and leads to azimuthal power imbalances between beams within a given cone (i.e., at the same polar angle in the target chamber). These variations are shown to correlate with variations in measured backscatter between beams of a same quadruplet. Using circularly polarized, instead of linearly polarized, light produces similar overall levels of CBET within a cone of beams but tends to reduce the azimuthal variations. This is expected to slightly improve irradiation symmetry and reduce the risk of backscatter from stimulated Brillouin scattering. Circular polarization may therefore be beneficial for the next generation of laser fusion drivers.
- Open Access
- 1 May 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (5)
Key metrics of progress in the NIF ignition implosions and future challenges on the path to higher yields
Successful demonstration of an implosion that meets the physics metrics for ignition on the National Ignition Facility (NIF) in August 2021 and demonstration of target energy gain G > 1 in December 2022 represented the culmination of more than a decade of research on the NIF. An in-depth analysis of the key ignition metrics achieved on the NIF over the past decade shows sustained progress toward identifying and mitigating degradation effects. Ignition implosions on the NIF have progressed from early experiments whose compressed fuel conditions were degraded by a factor of 10–20 below the ignition threshold with yields of only 1%–2% of the laser energy, to current experiments that significantly exceed the ignition threshold and in the best experiments achieve yields greater than twice the laser energy. It is very likely that NIF can get more than 20 MJ of yield and possibly 50–70 MJ yields when fully optimized at an ultraviolet laser energy of 2.6 MJ following the completion of the NIF Extended Yield Capability Project. Achieving these higher yields will also require improvements to capsules at larger size and possibly with alternate materials, as well as an improved understanding of hohlraum and capsule physics. Now that NIF has achieved ignition, the design of a Next Generation High Energy Density Facility that could achieve the National Nuclear Security Administration long-term goal of substantially higher yields than the NIF can proceed with a more confident physics base. We evaluate these opportunities including possible applications for inertial fusion energy and likely challenges to achieving this level of performance over the next decade.
- 1 May 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (5)
Open AccessKey metrics of progress in the NIF ignition implosions and future challenges on the path to higher yields
Successful demonstration of an implosion that meets the physics metrics for ignition on the National Ignition Facility (NIF) in August 2021 and demonstration of target energy gain G > 1 in December 2022 represented the culmination of more than a decade of research on the NIF. An in-depth analysis of the key ignition metrics achieved on the NIF over the past decade shows sustained progress toward identifying and mitigating degradation effects. Ignition implosions on the NIF have progressed from early experiments whose compressed fuel conditions were degraded by a factor of 10–20 below the ignition threshold with yields of only 1%–2% of the laser energy, to current experiments that significantly exceed the ignition threshold and in the best experiments achieve yields greater than twice the laser energy. It is very likely that NIF can get more than 20 MJ of yield and possibly 50–70 MJ yields when fully optimized at an ultraviolet laser energy of 2.6 MJ following the completion of the NIF Extended Yield Capability Project. Achieving these higher yields will also require improvements to capsules at larger size and possibly with alternate materials, as well as an improved understanding of hohlraum and capsule physics. Now that NIF has achieved ignition, the design of a Next Generation High Energy Density Facility that could achieve the National Nuclear Security Administration long-term goal of substantially higher yields than the NIF can proceed with a more confident physics base. We evaluate these opportunities including possible applications for inertial fusion energy and likely challenges to achieving this level of performance over the next decade.
- Open Access
- 27 February 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (3) , 035004
Diagnostic x-ray source using electrons produced by a 100 J-class picosecond laser *
Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f /#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.
- 27 February 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (3) , 035004
Open AccessDiagnostic x-ray source using electrons produced by a 100 J-class picosecond laser *
Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f /#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.
- Open Access
- 2 September 2025
- Published by American Physical Society (APS) in Physical Review X
- Vol. 15 (3)
Single-Shot Reconstruction of Electron Beam Longitudinal Phase Space in a Laser Wakefield Accelerator
We report on a single-shot longitudinal phase-space reconstruction diagnostic for electron beams in a laser wakefield accelerator via the experimental observation of distinct periodic modulations in the angularly resolved spectra. Such modulated angular spectra arise as a result of the direct interaction between the ultrarelativistic electron beam and the laser driver in the presence of the wakefield. A constrained theoretical model for the coupled oscillator, assisted by a genetic algorithm, can recreate the experimental electron spectra and, thus, fully reconstructs the longitudinal phase-space distribution of the electron beam with a temporal resolution of approximately 1.3 fs. In particular, it reveals the slice energy spread of the electron beam, which is important to measure for applications such as x-ray free electron lasers. In our experiment, the root-mean-square energy spread retrieved is bounded at 9.9 MeV, corresponding to a 0.9%–3.0% relative spread, despite the overall GeV energy beam having approximately 100% relative energy spread.
- 2 September 2025
- Published by American Physical Society (APS) in Physical Review X
- Vol. 15 (3)
Open AccessSingle-Shot Reconstruction of Electron Beam Longitudinal Phase Space in a Laser Wakefield Accelerator
We report on a single-shot longitudinal phase-space reconstruction diagnostic for electron beams in a laser wakefield accelerator via the experimental observation of distinct periodic modulations in the angularly resolved spectra. Such modulated angular spectra arise as a result of the direct interaction between the ultrarelativistic electron beam and the laser driver in the presence of the wakefield. A constrained theoretical model for the coupled oscillator, assisted by a genetic algorithm, can recreate the experimental electron spectra and, thus, fully reconstructs the longitudinal phase-space distribution of the electron beam with a temporal resolution of approximately 1.3 fs. In particular, it reveals the slice energy spread of the electron beam, which is important to measure for applications such as x-ray free electron lasers. In our experiment, the root-mean-square energy spread retrieved is bounded at 9.9 MeV, corresponding to a 0.9%–3.0% relative spread, despite the overall GeV energy beam having approximately 100% relative energy spread.
- Open Access
Multi-messenger dynamic imaging of laser-driven shocks in water using a plasma wakefield accelerator
Understanding dense matter hydrodynamics is critical for predicting plasma behavior in environments relevant to laser-driven inertial confinement fusion. Traditional diagnostic sources face limitations in brightness, spatiotemporal resolution, and inability to detect relevant electromagnetic fields. In this work, we present a dual-probe, multi-messenger laser wakefield accelerator platform combining ultrafast X-rays and relativistic electron beams at 1 Hz, to interrogate a free-flowing water target in vacuum, heated by an intense 200 ps laser pulse. This scheme enables high-repetition-rate tracking of the interaction evolution using both particle types. Betatron X-rays reveal a cylindrically symmetric shock compression morphology assisted by low-density vapor, resembling foam-layer-assisted fusion targets. The synchronized electron beam detects time-evolving electromagnetic fields, uncovering charge separation and ion species differentiation during plasma expansion - phenomena not captured by photons or hydrodynamic simulations. We show that combining both probes provides complementary insights spanning kinetic to hydrodynamic regimes, highlighting the need for hybrid physics models to accurately predict fusion-relevant plasma behavior
Open AccessMulti-messenger dynamic imaging of laser-driven shocks in water using a plasma wakefield accelerator
Understanding dense matter hydrodynamics is critical for predicting plasma behavior in environments relevant to laser-driven inertial confinement fusion. Traditional diagnostic sources face limitations in brightness, spatiotemporal resolution, and inability to detect relevant electromagnetic fields. In this work, we present a dual-probe, multi-messenger laser wakefield accelerator platform combining ultrafast X-rays and relativistic electron beams at 1 Hz, to interrogate a free-flowing water target in vacuum, heated by an intense 200 ps laser pulse. This scheme enables high-repetition-rate tracking of the interaction evolution using both particle types. Betatron X-rays reveal a cylindrically symmetric shock compression morphology assisted by low-density vapor, resembling foam-layer-assisted fusion targets. The synchronized electron beam detects time-evolving electromagnetic fields, uncovering charge separation and ion species differentiation during plasma expansion - phenomena not captured by photons or hydrodynamic simulations. We show that combining both probes provides complementary insights spanning kinetic to hydrodynamic regimes, highlighting the need for hybrid physics models to accurately predict fusion-relevant plasma behavior
- Open Access
- 1 July 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (7)
Increased electron, positron, and x-ray production from high intensity laser interactions using micro-wire targets
We report increases in energetic electrons, positrons, and x-rays emitted from high-intensity laser interactions (1018−20 W/cm2) with structured silicon micro-wires on the surface of a 1 mm gold converter target using a 10 ps laser pulse. A total of four different wire configurations are tested, where the gaps (7–28 μm) between the wires and the thicknesses (3–6 μm) of the wires are varied, while the height remains constant (∼ 25 μm). We observe the largest enhancement in electrons, positrons, and x-rays with the sparsest wire configurations. The electron temperature (T e≈ 6 MeV) remains consistent across all shots, regardless of whether wires or planar targets are used. This suggests that the observed enhancement is due to increased laser light absorption by the accelerated electrons over a long scale length. Two-dimensional particle-in-cell simulations confirm that absorption is significantly enhanced with the wire target. Additionally, specific simulations examining laser pointing on different parts of the wire structure reveal that, while the final electron spectrum remains largely insensitive, the angular distribution is highly sensitive to these variations.
- 1 July 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (7)
Open AccessIncreased electron, positron, and x-ray production from high intensity laser interactions using micro-wire targets
We report increases in energetic electrons, positrons, and x-rays emitted from high-intensity laser interactions (1018−20 W/cm2) with structured silicon micro-wires on the surface of a 1 mm gold converter target using a 10 ps laser pulse. A total of four different wire configurations are tested, where the gaps (7–28 μm) between the wires and the thicknesses (3–6 μm) of the wires are varied, while the height remains constant (∼ 25 μm). We observe the largest enhancement in electrons, positrons, and x-rays with the sparsest wire configurations. The electron temperature (T e≈ 6 MeV) remains consistent across all shots, regardless of whether wires or planar targets are used. This suggests that the observed enhancement is due to increased laser light absorption by the accelerated electrons over a long scale length. Two-dimensional particle-in-cell simulations confirm that absorption is significantly enhanced with the wire target. Additionally, specific simulations examining laser pointing on different parts of the wire structure reveal that, while the final electron spectrum remains largely insensitive, the angular distribution is highly sensitive to these variations.
- Open Access
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Laser-driven flash x-ray radiography of a shocked metallic foil
Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.
- 1 May 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (5)
Open AccessLaser-driven flash x-ray radiography of a shocked metallic foil
Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.
- Open Access
- 1 May 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (5)
Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign
This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.
- 1 May 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (5)
Open AccessResolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign
This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.