RKRoman Kozłowski

Roman Kozłowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Roman Kozłowski has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nowy energooszczędny magazyn Archiwum Narodowego w Krakowie

    by Roman Kozłowski

    Energy saving is in the vital economic interest of institutions preserving cultural heritage resources. Sustainability requirements emphasizing the reduction of carbon emissions also play an important role. In 2020, the storage segment at the new seat of the National Archives in Krakow was put into operation, combining energy efficiency with high-quality collection care. The facility has eight floors and will ultimately accommodate 70,000 linear meters of records. It is a separate structure with no permanent workspace, and the largely passive stabilization of the optimal microclimate for the collections has been ensured by well-thought-out construction solutions: good thermal insulation and high tightness of the building shell, and use of porous building materials with good water vapour exchange capacity on architectural surfaces. The conducted measurements showed that the temperature inside the storage followed the annual cycle of temperature changes outside reaching its lowest value in February 2021, between 11 and 14oC, depending on the floor. For most parts of the year – from October to June – relative humidity remained spontaneously at an optimal level of around 50% with minor short-term fluctuations. During the summer season, the air is dehumidified by energy-efficient dehumidification equipment. Dry conditions and low temperatures for most of the year reduce the rate of chemical degradation of archival objects.

  • Open Access

    Nowa siedziba Archiwum Narodowego w Krakowie. Założenia funkcjonalne i użytkowe oraz koncepcja magazynu zbiorów archiwalnych z pasywną regulacją klimatu

    by Barbara Berska, Łukasz Bratasz, Roman Kozłowski, Leszek Krzemień

    Budynek archiwum państwowego to miejsce służące przede wszystkim długoterminowej ochronie materiałów archiwalnych. Musi także spełniać wymagania stawiane przyjaznej instytucji publicznej, związane z obsługą i zaspokajaniem różnorodnych potrzeb użytkowników w zakresie działalności prowadzonej przez archiwa. Pełnione przez archiwa funkcje determinują, już na etapie opracowywania koncepcji, a następnie dokumentacji projektowej, kwestie konstrukcji, wyposażenia oraz zastosowanych instalacji i technologii. Szczególne znaczenie w przypadku archiwum państwowego mają pomieszczenia magazynowe, służące przechowywaniu materiałów archiwalnych. W wypadku nowej siedziby Archiwum Narodowego w Krakowie, dla ośmiokondygnacyjnego segmentu magazynowego opracowano koncepcję z pasywną regulacją klimatu. Jest on wyodrębnioną strukturą, w której nie ma stałych stanowisk pracy, a pasywną stabilizację mikroklimatu zapewniono w znacznym stopniu przez przemyślane rozwiązania budowlane: dobrą izolację termiczną, wysoką szczelność przegród zewnętrznych oraz wykonanie powierzchni architektonicznych z porowatych materiałów o dobrej zdolność do wymiany pary wodnej. Temperatura we wnętrzu magazynu podąża za rocznym cyklem zmian temperatury na zewnątrz, a wilgotność względna utrzymuje się samoistnie na optymalnym poziomie około 50% przez znaczną część roku. W porze ciepłej powietrze jest osuszane. Suche warunki i niska w porze zimnej temperatura ograniczają szybkość degradacji materiałów archiwalnych. New building of the National Archives in Krakow. Functional and operational assumptions and the concept of archival holdings storage with passive climate control A state archive building is a place that serves primarily the long-term preservation of archival materials. It must also meet the requirements of a friendly public institution, which include serving and satisfying various user needs in the field of archival activity. The archives’ functions determine the construction, equipment, installation and technology considerations at the very conceptual stage and later in the design documentation. In case of a state archive, storage facilities used for the storage of archival materials are of particular importance. In case of the new building of the National Archives in Kraków, a concept involving passive climate control has been developed for the eight-storey storage segment. The storage segment is a separate structure, with no permanent workstations. The largely passive stabilization of the microclimate was ensured by well-thought-out construction solutions: good thermal insulation, high-performance external partitions and installation of architectural surfaces made of porous materials with good water vapor exchange capacity. Temperature inside the storage facility follows the annual cycle of external emperaturę changes, and relative humidity remains spontaneously at the optimum level of approximately 50% throughout much of the year. During the warm season, the air is dehumidified. Dry conditions and low temperatures in the cold season reduce the rate of degradation of archival materials.


  • Open Access

    HERIe: A Web-Based Decision-Supporting Tool for Assessing Risk of Physical Damage Using Various Failure Criteria

    by Arkadiusz Kupczak, Mariusz JęDrychowski, Marcin Strojecki, Leszek Krzemień, Łukasz Bratasz, Michał Łukomski, Roman Kozłowski

    HERIe is a web-based decision-supporting software tool to facilitate the management of collection environments by precise assessment of climate-induced risk of physical damage to vulnerable objects. The software translates the relative humidity and temperature data recorded in the environment of the analysed object into a strain history experienced by it, and estimates the risk of physical damage using selected failure criteria. As all information is pre-calculated for the user, no engagement in complex and time-consuming numerical simulations is required. HERIe is available for testing at herie.mnk.pl. Detailed information on the methodologies used by the software is available at the above website which also contains tutorial climates. The current work aims at refining HERIe by selecting the damage criteria not only from laboratory studies but also from direct monitoring damage accumulation in objects, especially using the acoustic emission method. The software has been expanded to include moisture-induced response of parchment to support managing environments in libraries and archives.


  • Particle Penetration, Emission and Deposition in the Diocesan Museum in Udine, Italy to Assess Soiling of Giambattista Tiepolo’s Wall Paintings

    by Chiara Bertolin, Marcin Strojecki, Roman Kozłowski

    The soiling of valuable surfaces indoors depends on particle size, concentration and chemical composition, air and surface temperature, air velocity and surface roughness. A growing body of researc...


  • Open Access

    Moisture sorption and diffusion in historical cellulose-based materials

    by Arkadiusz Kupczak, Łukasz Bratasz, Joanna Kryściak-Czerwenka, Roman Kozłowski


  • Impact of paper and wooden collections on humidity stability and energy consumption in museums and libraries

    by Arkadiusz Kupczak, Agnieszka Sadłowska-Sałęga, Leszek Krzemień, Joanna Sobczyk, Jan Radoń, Roman Kozłowski


  • The effect of ventilation on soiling by particles of outdoor and indoor origin in historical churches

    by Agata Mleczkowska, Marcin Strojecki, Łukasz Bratasz, Roman Kozłowski


  • Open Access

    Mechanism of craquelure pattern formation on panel paintings

    by Leszek Krzemień, Michał Łukomski, Łukasz Bratasz, Roman Kozłowski, Marion F. Mecklenburg

    The drying shrinkage accumulation from exposure of freshly prepared gesso layers to relative humidity (RH) cycles was determined to elucidate the mechanism of craquelure pattern formation on panel paintings. The progresive drying shrinkage of the gesso is observed only under the cycles going to high RH levels which bring about transitions from brittle to ductile state of the material. The first incidence of fracture on the gesso layers occurred after a limited number of cycles ranging between a few and 100 for a range of layer thickness between 0.5 and 1 mm. The craquelure patterns stabilised also after a limited number of cycles (30 for the 1-mm thick layer). Upon increase in the gesso layer thickness, the strength of the layer is reduced and the spacing of shrinkage fractures increases. The study demonstrated that craquelure patterns, mimicking historical ones, can be realistically produced in laboratory conditions. Such studies would provide useful information for preparing specimens simulating historic panel paintings and would inform the current efforts on automatic, computer-aided classifications of crack formations on paintings.


  • Particle penetration and deposition inside historical churches

    by Agata Mleczkowska, Marcin Strojecki, Łukasz Bratasz, Roman Kozłowski


  • Risk of Climate‐Induced Damage in Historic Textiles

    by Ł. Bratasz, M. Łukomski, A. Klisińska‐Kopacz, W. Zawadzki, K. Dzierżęga, M. Bartosik, J. Sobczyk, F. J. Lennard, R. Kozłowski

    Eleven wool and silk historic textiles and two modern artist's canvases were examined to determine their water vapour adsorption, moisture dimensional response and tensile behaviour. All the textiles showed a similar general pattern of moisture response. A rise in ambient relative humidity (RH) from dry conditions produced expansion of a textile until a certain critical RH level after which a contraction occurred to a greater or lesser degree depending on the yarn crimp and the weave geometry. The largest expansion recorded between the dry state and 80% RH was 1.2 and 0.9% for wool and silk textiles, respectively. The largest shrinkage of 0.8% at high RH range was experienced by a modern linen canvas. Two potential damage mechanisms related to the moisture response of the textiles—stress building as a result of shrinkage of the textile restrained in its dimensional response and the fretting fatigue when yarns move with friction one against another—were found insignificant in typical textile display environments unless the textiles are severely degraded or excessively strained in their mounting.