Jie Fu
Research Subjects
Jie Fu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alexander M. Reyzelman
California School of Podiatric Medicine Samuel Merritt University San Francisco, CA United States
4 shared publications - Henk Jan Scholten
Siren Care Inc, San Francisco, CA, United States
4 shared publications - Ran Ma
Siren Care Inc, San Francisco, CA, United States
4 shared publications - Caileigh Smith
Samuel Merritt University, San Francisco, CA, United States
2 shared publications - Chia-Ding Shih
USC Keck School of Medicine: University of Southern California Keck School of Medicine
2 shared publications - E Yu
Siren Care (Shanghai) Information Technology Co Ltd, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 29 January 2024
- Published by JMIR Publications Inc. in JMIR Diabetes
- Vol. 9 (1) , e46096
Effectiveness of a Continuous Remote Temperature Monitoring Program to Reduce Foot Ulcers and Amputations: Multicenter Postmarket Registry Study
Background: Neuropathic foot ulcers are the leading cause of nontraumatic foot amputations, particularly among patients with diabetes. Traditional methods of monitoring and managing these patients are periodic in-person clinic visits, which are passive and may be insufficient for preventing neuropathic foot ulcers and amputations. Continuous remote temperature monitoring has the potential to capture the critical period before the foot ulcers develop and to improve outcomes by providing real-time data and early interventions. For the first time, the effectiveness of such a strategy to prevent neuropathic foot ulcers and related complications among high-risk patients in a real-world commercial setting is reported. Objective: This study aims to evaluate the effectiveness of a real-world continuous remote temperature monitoring program in preventing neuropathic foot ulcers and amputations in patients with diabetes. Methods: In this retrospective analysis of a real-world continuous remote temperature monitoring program, 115 high-risk patients identified by clinical providers from 15 geographically diverse private podiatry offices were analyzed. Patients received continuous remote monitoring socks as part of the program. The enrollment was based on medical necessity as decided by their managing physician. We evaluated data from up to 2 years before enrollment and up to 3 years during the program. The primary outcome was the rate of wound development. Secondary outcomes included amputation rate, the severity of the foot ulcers, and the number of visits to an outpatient podiatry clinic after enrolling in the program. Results: We observed significantly lower rates of foot ulceration (relative risk reduction [RRR] 0.68; 95% CI 0.52-0.79; number needed to treat [NNT] 5.0; P<.001), less moderate to severe ulcers (RRR 0.86; 95% CI 0.70-0.93; NNT 16.2; P<.001), less amputations (RRR 0.83; 95% CI 0.39-0.95; NNT 41.7; P=.006), and less hospitalizations (RRR 0.63; 95% CI 0.33-0.80; NNT 5.7; P<.002). We found a decrease in outpatient podiatry office visits during the program (RRR 0.31; 95% CI 0.24-0.37; NNT 0.46; P<.001). Conclusions: Our findings suggested that a real-world continuous remote temperature monitoring program was an effective strategy to prevent foot ulcer development and nontraumatic foot amputation among high-risk patients.
- 29 January 2024
- Published by JMIR Publications Inc. in JMIR Diabetes
- Vol. 9 (1) , e46096
Open AccessEffectiveness of a Continuous Remote Temperature Monitoring Program to Reduce Foot Ulcers and Amputations: Multicenter Postmarket Registry Study
Background: Neuropathic foot ulcers are the leading cause of nontraumatic foot amputations, particularly among patients with diabetes. Traditional methods of monitoring and managing these patients are periodic in-person clinic visits, which are passive and may be insufficient for preventing neuropathic foot ulcers and amputations. Continuous remote temperature monitoring has the potential to capture the critical period before the foot ulcers develop and to improve outcomes by providing real-time data and early interventions. For the first time, the effectiveness of such a strategy to prevent neuropathic foot ulcers and related complications among high-risk patients in a real-world commercial setting is reported. Objective: This study aims to evaluate the effectiveness of a real-world continuous remote temperature monitoring program in preventing neuropathic foot ulcers and amputations in patients with diabetes. Methods: In this retrospective analysis of a real-world continuous remote temperature monitoring program, 115 high-risk patients identified by clinical providers from 15 geographically diverse private podiatry offices were analyzed. Patients received continuous remote monitoring socks as part of the program. The enrollment was based on medical necessity as decided by their managing physician. We evaluated data from up to 2 years before enrollment and up to 3 years during the program. The primary outcome was the rate of wound development. Secondary outcomes included amputation rate, the severity of the foot ulcers, and the number of visits to an outpatient podiatry clinic after enrolling in the program. Results: We observed significantly lower rates of foot ulceration (relative risk reduction [RRR] 0.68; 95% CI 0.52-0.79; number needed to treat [NNT] 5.0; P<.001), less moderate to severe ulcers (RRR 0.86; 95% CI 0.70-0.93; NNT 16.2; P<.001), less amputations (RRR 0.83; 95% CI 0.39-0.95; NNT 41.7; P=.006), and less hospitalizations (RRR 0.63; 95% CI 0.33-0.80; NNT 5.7; P<.002). We found a decrease in outpatient podiatry office visits during the program (RRR 0.31; 95% CI 0.24-0.37; NNT 0.46; P<.001). Conclusions: Our findings suggested that a real-world continuous remote temperature monitoring program was an effective strategy to prevent foot ulcer development and nontraumatic foot amputation among high-risk patients.
- Open Access
- 30 January 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Effectiveness of a Continuous Remote Temperature Monitoring Program to Reduce Foot Ulcers and Amputations: Multicenter Postmarket Registry Study (Preprint)
BACKGROUND Neuropathic foot ulcers are the leading cause of nontraumatic foot amputations, particularly among patients with diabetes. Traditional methods of monitoring and managing these patients are periodic in-person clinic visits, which are passive and may be insufficient for preventing neuropathic foot ulcers and amputations. Continuous remote temperature monitoring has the potential to capture the critical period before the foot ulcers develop and to improve outcomes by providing real-time data and early interventions. For the first time, the effectiveness of such a strategy to prevent neuropathic foot ulcers and related complications among high-risk patients in a real-world commercial setting is reported. OBJECTIVE This study aims to evaluate the effectiveness of a real-world continuous remote temperature monitoring program in preventing neuropathic foot ulcers and amputations in patients with diabetes. METHODS In this retrospective analysis of a real-world continuous remote temperature monitoring program, 115 high-risk patients identified by clinical providers from 15 geographically diverse private podiatry offices were analyzed. Patients received continuous remote monitoring socks as part of the program. The enrollment was based on medical necessity as decided by their managing physician. We evaluated data from up to 2 years before enrollment and up to 3 years during the program. The primary outcome was the rate of wound development. Secondary outcomes included amputation rate, the severity of the foot ulcers, and the number of visits to an outpatient podiatry clinic after enrolling in the program. RESULTS We observed significantly lower rates of foot ulceration (relative risk reduction [RRR] 0.68; 95% CI 0.52-0.79; number needed to treat [NNT] 5.0; P<.001), less moderate to severe ulcers (RRR 0.86; 95% CI 0.70-0.93; NNT 16.2; P<.001), less amputations (RRR 0.83; 95% CI 0.39-0.95; NNT 41.7; P=.006), and less hospitalizations (RRR 0.63; 95% CI 0.33-0.80; NNT 5.7; P<.002). We found a decrease in outpatient podiatry office visits during the program (RRR 0.31; 95% CI 0.24-0.37; NNT 0.46; P<.001). CONCLUSIONS Our findings suggested that a real-world continuous remote temperature monitoring program was an effective strategy to prevent foot ulcer development and nontraumatic foot amputation among high-risk patients.
- 30 January 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEffectiveness of a Continuous Remote Temperature Monitoring Program to Reduce Foot Ulcers and Amputations: Multicenter Postmarket Registry Study (Preprint)
BACKGROUND Neuropathic foot ulcers are the leading cause of nontraumatic foot amputations, particularly among patients with diabetes. Traditional methods of monitoring and managing these patients are periodic in-person clinic visits, which are passive and may be insufficient for preventing neuropathic foot ulcers and amputations. Continuous remote temperature monitoring has the potential to capture the critical period before the foot ulcers develop and to improve outcomes by providing real-time data and early interventions. For the first time, the effectiveness of such a strategy to prevent neuropathic foot ulcers and related complications among high-risk patients in a real-world commercial setting is reported. OBJECTIVE This study aims to evaluate the effectiveness of a real-world continuous remote temperature monitoring program in preventing neuropathic foot ulcers and amputations in patients with diabetes. METHODS In this retrospective analysis of a real-world continuous remote temperature monitoring program, 115 high-risk patients identified by clinical providers from 15 geographically diverse private podiatry offices were analyzed. Patients received continuous remote monitoring socks as part of the program. The enrollment was based on medical necessity as decided by their managing physician. We evaluated data from up to 2 years before enrollment and up to 3 years during the program. The primary outcome was the rate of wound development. Secondary outcomes included amputation rate, the severity of the foot ulcers, and the number of visits to an outpatient podiatry clinic after enrolling in the program. RESULTS We observed significantly lower rates of foot ulceration (relative risk reduction [RRR] 0.68; 95% CI 0.52-0.79; number needed to treat [NNT] 5.0; P<.001), less moderate to severe ulcers (RRR 0.86; 95% CI 0.70-0.93; NNT 16.2; P<.001), less amputations (RRR 0.83; 95% CI 0.39-0.95; NNT 41.7; P=.006), and less hospitalizations (RRR 0.63; 95% CI 0.33-0.80; NNT 5.7; P<.002). We found a decrease in outpatient podiatry office visits during the program (RRR 0.31; 95% CI 0.24-0.37; NNT 0.46; P<.001). CONCLUSIONS Our findings suggested that a real-world continuous remote temperature monitoring program was an effective strategy to prevent foot ulcer development and nontraumatic foot amputation among high-risk patients.
- Open Access
- 17 December 2018
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 20 (12) , e12460
Continuous Temperature-Monitoring Socks for Home Use in Patients With Diabetes: Observational Study
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Over 30 million people in the United States (over 9%) have been diagnosed with diabetes. About 25% of people with diabetes will experience a foot ulcer (DFU) in their lifetime. Unresolved DFUs may lead to sepsis and are the leading case of lower limb amputations. DFU rates can be reduced by screening patients with diabetes to enable risk-based interventions. Skin temperature assessment has been shown to reduce the risk of foot ulceration. While several tools have been developed to measure plantar temperatures, they measure temperature once a day or are designed for clinic use only. In this report, wireless sensor-embedded socks designed for daily wear are introduced, which perform continuous temperature monitoring of the feet of persons with diabetes in the home environment. Combined with a mobile app, this wearable device informs the wearer about temperature increases in one foot relative to the other, to facilitate early detection of ulcers and timely intervention. Objective: A pilot study was conducted to assess the accuracy of sensors used in daily wear socks, obtain user feedback on how comfortable sensor-embedded socks were for home use, and examine whether observed temperatures correlated with clinical observations. Methods: Temperature accuracy of sensors was assessed both prior to incorporation in the socks, as well as in the completed design. The measured temperatures were compared to the reference standard, a high precision thermostatic water bath in the range 20℃ to 40℃. Thirty-five (35) patients with diabetic peripheral neuropathy, 18 years and older, were enrolled in a single-site study conducted under an IRB-approved protocol to evaluate the usability of the sensor embedded socks and to correlate the observed temperatures with clinical findings. Results: The temperatures measured by the standalone sensors were within 0.2℃ of the reference standard. In the sensor-embedded socks, across multiple measurements for each of the six sensors, a high agreement (R2 = 1) between temperatures measured and the reference standard was observed. Patients reported that the socks were easy to use and comfortable, ranking them at a median score of 9 or 10 for comfort and ease of use on a 10-point scale. Cases are presented showing that the temperature differences observed between the feet was consistent with clinical observations. Conclusions: We report the first use of wireless continuous temperature monitoring for daily wear and home use in patients with diabetes and neuropathy. The wearers found the socks to be no different from standard socks. The temperature studies conducted show that the sensors used in the socks are reliable and accurate at detecting temperature, and the findings matched clinical observations. Continuous temperature monitoring is a promising approach as an early warning system for foot ulcers, Charcot foot, and re-ulceration.
- 17 December 2018
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 20 (12) , e12460
Open AccessContinuous Temperature-Monitoring Socks for Home Use in Patients With Diabetes: Observational Study
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Over 30 million people in the United States (over 9%) have been diagnosed with diabetes. About 25% of people with diabetes will experience a foot ulcer (DFU) in their lifetime. Unresolved DFUs may lead to sepsis and are the leading case of lower limb amputations. DFU rates can be reduced by screening patients with diabetes to enable risk-based interventions. Skin temperature assessment has been shown to reduce the risk of foot ulceration. While several tools have been developed to measure plantar temperatures, they measure temperature once a day or are designed for clinic use only. In this report, wireless sensor-embedded socks designed for daily wear are introduced, which perform continuous temperature monitoring of the feet of persons with diabetes in the home environment. Combined with a mobile app, this wearable device informs the wearer about temperature increases in one foot relative to the other, to facilitate early detection of ulcers and timely intervention. Objective: A pilot study was conducted to assess the accuracy of sensors used in daily wear socks, obtain user feedback on how comfortable sensor-embedded socks were for home use, and examine whether observed temperatures correlated with clinical observations. Methods: Temperature accuracy of sensors was assessed both prior to incorporation in the socks, as well as in the completed design. The measured temperatures were compared to the reference standard, a high precision thermostatic water bath in the range 20℃ to 40℃. Thirty-five (35) patients with diabetic peripheral neuropathy, 18 years and older, were enrolled in a single-site study conducted under an IRB-approved protocol to evaluate the usability of the sensor embedded socks and to correlate the observed temperatures with clinical findings. Results: The temperatures measured by the standalone sensors were within 0.2℃ of the reference standard. In the sensor-embedded socks, across multiple measurements for each of the six sensors, a high agreement (R2 = 1) between temperatures measured and the reference standard was observed. Patients reported that the socks were easy to use and comfortable, ranking them at a median score of 9 or 10 for comfort and ease of use on a 10-point scale. Cases are presented showing that the temperature differences observed between the feet was consistent with clinical observations. Conclusions: We report the first use of wireless continuous temperature monitoring for daily wear and home use in patients with diabetes and neuropathy. The wearers found the socks to be no different from standard socks. The temperature studies conducted show that the sensors used in the socks are reliable and accurate at detecting temperature, and the findings matched clinical observations. Continuous temperature monitoring is a promising approach as an early warning system for foot ulcers, Charcot foot, and re-ulceration.
- Open Access
- 9 October 2018
- Published by JMIR Publications Inc. in JMIR Preprints
Continuous Temperature-Monitoring Socks for Home Use in Patients With Diabetes: Observational Study (Preprint)
BACKGROUND Over 30 million people in the United States (over 9%) have been diagnosed with diabetes. About 25% of people with diabetes will experience a diabetic foot ulcer (DFU) in their lifetime. Unresolved DFUs may lead to sepsis and are the leading cause of lower-limb amputations. DFU rates can be reduced by screening patients with diabetes to enable risk-based interventions. Skin temperature assessment has been shown to reduce the risk of foot ulceration. While several tools have been developed to measure plantar temperatures, they only measure temperature once a day or are designed for clinic use only. In this report, wireless sensor-embedded socks designed for daily wear are introduced, which perform continuous temperature monitoring of the feet of persons with diabetes in the home environment. Combined with a mobile app, this wearable device informs the wearer about temperature increases in one foot relative to the other, to facilitate early detection of ulcers and timely intervention. OBJECTIVE A pilot study was conducted to assess the accuracy of sensors used in daily wear socks, obtain user feedback on how comfortable sensor-embedded socks were for home use, and examine whether observed temperatures correlated with clinical observations. METHODS Temperature accuracy of sensors was assessed both prior to incorporation in the socks, as well as in the completed design. The measured temperatures were compared to the reference standard, a high-precision thermostatic water bath in the range 20°C-40°C. A total of 35 patients, 18 years of age and older, with diabetic peripheral neuropathy were enrolled in a single-site study conducted under an Institutional Review Board–approved protocol. This study evaluated the usability of the sensor-embedded socks and correlated the observed temperatures with clinical findings. RESULTS The temperatures measured by the stand-alone sensors were within 0.2°C of the reference standard. In the sensor-embedded socks, across multiple measurements for each of the six sensors, a high agreement (R2=1) between temperatures measured and the reference standard was observed. Patients reported that the socks were easy to use and comfortable, ranking them at a median score of 9 or 10 for comfort and ease of use on a 10-point scale. Case studies are presented showing that the temperature differences observed between the feet were consistent with clinical observations. CONCLUSIONS We report the first use of wireless continuous temperature monitoring for daily wear and home use in patients with diabetes and neuropathy. The wearers found the socks to be no different from standard socks. The temperature studies conducted show that the sensors used in the socks are reliable and accurate at detecting temperature and the findings matched clinical observations. Continuous temperature monitoring is a promising approach as an early warning system for foot ulcers, Charcot foot, and reulceration.
- 9 October 2018
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessContinuous Temperature-Monitoring Socks for Home Use in Patients With Diabetes: Observational Study (Preprint)
BACKGROUND Over 30 million people in the United States (over 9%) have been diagnosed with diabetes. About 25% of people with diabetes will experience a diabetic foot ulcer (DFU) in their lifetime. Unresolved DFUs may lead to sepsis and are the leading cause of lower-limb amputations. DFU rates can be reduced by screening patients with diabetes to enable risk-based interventions. Skin temperature assessment has been shown to reduce the risk of foot ulceration. While several tools have been developed to measure plantar temperatures, they only measure temperature once a day or are designed for clinic use only. In this report, wireless sensor-embedded socks designed for daily wear are introduced, which perform continuous temperature monitoring of the feet of persons with diabetes in the home environment. Combined with a mobile app, this wearable device informs the wearer about temperature increases in one foot relative to the other, to facilitate early detection of ulcers and timely intervention. OBJECTIVE A pilot study was conducted to assess the accuracy of sensors used in daily wear socks, obtain user feedback on how comfortable sensor-embedded socks were for home use, and examine whether observed temperatures correlated with clinical observations. METHODS Temperature accuracy of sensors was assessed both prior to incorporation in the socks, as well as in the completed design. The measured temperatures were compared to the reference standard, a high-precision thermostatic water bath in the range 20°C-40°C. A total of 35 patients, 18 years of age and older, with diabetic peripheral neuropathy were enrolled in a single-site study conducted under an Institutional Review Board–approved protocol. This study evaluated the usability of the sensor-embedded socks and correlated the observed temperatures with clinical findings. RESULTS The temperatures measured by the stand-alone sensors were within 0.2°C of the reference standard. In the sensor-embedded socks, across multiple measurements for each of the six sensors, a high agreement (R2=1) between temperatures measured and the reference standard was observed. Patients reported that the socks were easy to use and comfortable, ranking them at a median score of 9 or 10 for comfort and ease of use on a 10-point scale. Case studies are presented showing that the temperature differences observed between the feet were consistent with clinical observations. CONCLUSIONS We report the first use of wireless continuous temperature monitoring for daily wear and home use in patients with diabetes and neuropathy. The wearers found the socks to be no different from standard socks. The temperature studies conducted show that the sensors used in the socks are reliable and accurate at detecting temperature and the findings matched clinical observations. Continuous temperature monitoring is a promising approach as an early warning system for foot ulcers, Charcot foot, and reulceration.