Jong-Hwan Jang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jong-Hwan Jang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Dukyong Yoon
Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Korea
8 shared publications - Tae Young Kim
Medical AI Research Center, Samsung Medical Center, Seoul, Republic of Korea
5 shared publications - Joon-Myoung Kwon
Medical AI Inc Seoul
4 shared publications - Yong-Yeon Jo
Digital Healthcare Institute, Sejong Medical Research Institute, Bucheon 14754, Republic of Korea
4 shared publications - Changho Han
Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Republic of Korea
3 shared publications - Hak Seung Lee
Digital Healthcare Institute, Sejong Medical Research Institute, Bucheon, Republic of Korea; Medical AI Co, Ltd, Seoul, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 6 May 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Training Trajectories Reveal Cross-Modality Generalization Gaps in 12-Lead–Trained AI-ECG Deployed on Smartwatch Recordings (Preprint)
UNSTRUCTURED AI-ECG models trained on 12-lead–derived Lead I demonstrated comparable endpoint discrimination on smartwatch-derived Lead I but substantially divergent training trajectories, revealing cross-modality generalization gaps not detected by endpoint metrics alone.
- 6 May 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessTraining Trajectories Reveal Cross-Modality Generalization Gaps in 12-Lead–Trained AI-ECG Deployed on Smartwatch Recordings (Preprint)
UNSTRUCTURED AI-ECG models trained on 12-lead–derived Lead I demonstrated comparable endpoint discrimination on smartwatch-derived Lead I but substantially divergent training trajectories, revealing cross-modality generalization gaps not detected by endpoint metrics alone.
- Open Access
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Signal Processing
- Vol. 7, 185-194
VCP: Visible Context Propagation for Electrocardiogram Recovery
Electrocardiograms (ECGs) remain widely archived as paper ECG charts. In the 12-lead paper ECG chart layout, each lead shows only 2.5-second visible segments. Therefore, digitized charts are incomplete, leaving most of the 10-second recording invisible and misaligned with the digital standard required by ECG-AI models. Previous work has attempted to recover these invisible segments but has shown markedly lower performance than visible segments. We propose the Visible Context Propagation (VCP) architecture, an extension of ECGrecover, which leverages the quasi-periodic structure of ECGs and employs cross-attention to propagate contextual information from visible to invisible segments. Our model consistently outperformed ECGrecover, the strongest baseline, reducing RMSE by $32.4\%$ overall, including $12.0\%$ on invisible segments. Beyond recovery accuracy, evaluations on ECG applications demonstrated that recovered ECGs achieved performance comparable to raw ECGs in both diagnostic classification and ECG feature measurement. These results highlight the effectiveness of explicitly modeling the propagation of visible-to-invisible context and establish VCP as a robust solution for recovering incomplete paper-based ECGs, enabling reliable surrogates for clinical and analytical use.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Signal Processing
- Vol. 7, 185-194
Open AccessVCP: Visible Context Propagation for Electrocardiogram Recovery
Electrocardiograms (ECGs) remain widely archived as paper ECG charts. In the 12-lead paper ECG chart layout, each lead shows only 2.5-second visible segments. Therefore, digitized charts are incomplete, leaving most of the 10-second recording invisible and misaligned with the digital standard required by ECG-AI models. Previous work has attempted to recover these invisible segments but has shown markedly lower performance than visible segments. We propose the Visible Context Propagation (VCP) architecture, an extension of ECGrecover, which leverages the quasi-periodic structure of ECGs and employs cross-attention to propagate contextual information from visible to invisible segments. Our model consistently outperformed ECGrecover, the strongest baseline, reducing RMSE by $32.4\%$ overall, including $12.0\%$ on invisible segments. Beyond recovery accuracy, evaluations on ECG applications demonstrated that recovered ECGs achieved performance comparable to raw ECGs in both diagnostic classification and ECG feature measurement. These results highlight the effectiveness of explicitly modeling the propagation of visible-to-invisible context and establish VCP as a robust solution for recovering incomplete paper-based ECGs, enabling reliable surrogates for clinical and analytical use.
- Open Access
- 22 July 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (15) , 1837
Transparent and Robust Artificial Intelligence-Driven Electrocardiogram Model for Left Ventricular Systolic Dysfunction
Background/Objectives: Heart failure (HF) is a growing global health burden, yet early detection remains challenging due to the limitations of traditional diagnostic tools such as electrocardiograms (ECGs). Recent advances in deep learning offer new opportunities to identify left ventricular systolic dysfunction (LVSD), a key indicator of HF, from ECG data. This study validates AiTiALVSD, our previously developed artificial intelligence (AI)-enabled ECG Software as a Medical Device, for its accuracy, transparency, and robustness in detecting LVSD. Methods: This retrospective single-center cohort study involved patients suspected of LVSD. The AiTiALVSD model, based on a deep learning algorithm, was evaluated against echocardiographic ejection fraction values. To enhance model transparency, the study employed Testing with Concept Activation Vectors (TCAV), clustering analysis, and robustness testing against ECG noise and lead reversals. Results: The study involved 688 participants and found AiTiALVSD to have a high diagnostic performance, with an AUROC of 0.919. There was a significant correlation between AiTiALVSD scores and left ventricular ejection fraction values, confirming the model’s predictive accuracy. TCAV analysis showed the model’s alignment with medical knowledge, establishing its clinical plausibility. Despite its robustness to ECG artifacts, there was a noted decrease in specificity in the presence of ECG noise. Conclusions: AiTiALVSD’s high diagnostic accuracy, transparency, and resilience to common ECG discrepancies underscore its potential for early LVSD detection in clinical settings. This study highlights the importance of transparency and robustness in AI-ECG, setting a new benchmark in cardiac care.
- 22 July 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (15) , 1837
Open AccessTransparent and Robust Artificial Intelligence-Driven Electrocardiogram Model for Left Ventricular Systolic Dysfunction
Background/Objectives: Heart failure (HF) is a growing global health burden, yet early detection remains challenging due to the limitations of traditional diagnostic tools such as electrocardiograms (ECGs). Recent advances in deep learning offer new opportunities to identify left ventricular systolic dysfunction (LVSD), a key indicator of HF, from ECG data. This study validates AiTiALVSD, our previously developed artificial intelligence (AI)-enabled ECG Software as a Medical Device, for its accuracy, transparency, and robustness in detecting LVSD. Methods: This retrospective single-center cohort study involved patients suspected of LVSD. The AiTiALVSD model, based on a deep learning algorithm, was evaluated against echocardiographic ejection fraction values. To enhance model transparency, the study employed Testing with Concept Activation Vectors (TCAV), clustering analysis, and robustness testing against ECG noise and lead reversals. Results: The study involved 688 participants and found AiTiALVSD to have a high diagnostic performance, with an AUROC of 0.919. There was a significant correlation between AiTiALVSD scores and left ventricular ejection fraction values, confirming the model’s predictive accuracy. TCAV analysis showed the model’s alignment with medical knowledge, establishing its clinical plausibility. Despite its robustness to ECG artifacts, there was a noted decrease in specificity in the presence of ECG noise. Conclusions: AiTiALVSD’s high diagnostic accuracy, transparency, and resilience to common ECG discrepancies underscore its potential for early LVSD detection in clinical settings. This study highlights the importance of transparency and robustness in AI-ECG, setting a new benchmark in cardiac care.
- Open Access
- 1 January 2023
- Published by XMLink in Korean Circulation Journal
- Vol. 53 (11) , 758-771
Identifying Atrial Fibrillation With Sinus Rhythm Electrocardiogram in Embolic Stroke of Undetermined Source: A Validation Study With Insertable Cardiac Monitors
Jeon KH, et al. Korean Circ J. 2023 Aug;53:e63. https://doi.org/10.4070/kcj.2023.0009
- 1 January 2023
- Published by XMLink in Korean Circulation Journal
- Vol. 53 (11) , 758-771
Open AccessIdentifying Atrial Fibrillation With Sinus Rhythm Electrocardiogram in Embolic Stroke of Undetermined Source: A Validation Study With Insertable Cardiac Monitors
Jeon KH, et al. Korean Circ J. 2023 Aug;53:e63. https://doi.org/10.4070/kcj.2023.0009
- Open Access
Towards Synthesizing Twelve-Lead Electrocardiograms from Two Asynchronous Leads
The electrocardiogram (ECG) records electrical signals in a non-invasive way to observe the condition of the heart, typically looking at the heart from 12 different directions. Several types of the cardiac disease are diagnosed by using 12-lead ECGs Recently, various wearable devices have enabled immediate access to the ECG without the use of wieldy equipment. However, they only provide ECGs with a couple of leads. This results in an inaccurate diagnosis of cardiac disease due to lacking of required leads. We propose a deep generative model for ECG synthesis from two asynchronous leads to ten leads. It first represents a heart condition referring to two leads, and then generates ten leads based on the represented heart condition. Both the rhythm and amplitude of leads generated resemble those of the original ones, while the technique removes noise and the baseline wander appearing in the original leads. As a data augmentation method, our model improves the classification performance of models compared with models using ECGs with only one or two leads.
Open AccessTowards Synthesizing Twelve-Lead Electrocardiograms from Two Asynchronous Leads
The electrocardiogram (ECG) records electrical signals in a non-invasive way to observe the condition of the heart, typically looking at the heart from 12 different directions. Several types of the cardiac disease are diagnosed by using 12-lead ECGs Recently, various wearable devices have enabled immediate access to the ECG without the use of wieldy equipment. However, they only provide ECGs with a couple of leads. This results in an inaccurate diagnosis of cardiac disease due to lacking of required leads. We propose a deep generative model for ECG synthesis from two asynchronous leads to ten leads. It first represents a heart condition referring to two leads, and then generates ten leads based on the represented heart condition. Both the rhythm and amplitude of leads generated resemble those of the original ones, while the technique removes noise and the baseline wander appearing in the original leads. As a data augmentation method, our model improves the classification performance of models compared with models using ECGs with only one or two leads.
- Open Access
- 10 September 2021
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 23 (9) , e31129
Automated Detection of Acute Myocardial Infarction Using Asynchronous Electrocardiogram Signals—Preview of Implementing Artificial Intelligence With Multichannel Electrocardiographs Obtained From Smartwatches: Retrospective Study
Background: When using a smartwatch to obtain electrocardiogram (ECG) signals from multiple leads, the device has to be placed on different parts of the body sequentially. The ECG signals measured from different leads are asynchronous. Artificial intelligence (AI) models for asynchronous ECG signals have barely been explored. Objective: We aimed to develop an AI model for detecting acute myocardial infarction using asynchronous ECGs and compare its performance with that of the automatic ECG interpretations provided by a commercial ECG analysis software. We sought to evaluate the feasibility of implementing multiple lead–based AI-enabled ECG algorithms on smartwatches. Moreover, we aimed to determine the optimal number of leads for sufficient diagnostic power. Methods: We extracted ECGs recorded within 24 hours from each visit to the emergency room of Ajou University Medical Center between June 1994 and January 2018 from patients aged 20 years or older. The ECGs were labeled on the basis of whether a diagnostic code corresponding to acute myocardial infarction was entered. We derived asynchronous ECG lead sets from standard 12-lead ECG reports and simulated a situation similar to the sequential recording of ECG leads via smartwatches. We constructed an AI model based on residual networks and self-attention mechanisms by randomly masking each lead channel during the training phase and then testing the model using various targeting lead sets with the remaining lead channels masked. Results: The performance of lead sets with 3 or more leads compared favorably with that of the automatic ECG interpretations provided by a commercial ECG analysis software, with 8.1%-13.9% gain in sensitivity when the specificity was matched. Our results indicate that multiple lead-based AI-enabled ECG algorithms can be implemented on smartwatches. Model performance generally increased as the number of leads increased (12-lead sets: area under the receiver operating characteristic curve [AUROC] 0.880; 4-lead sets: AUROC 0.858, SD 0.008; 3-lead sets: AUROC 0.845, SD 0.011; 2-lead sets: AUROC 0.813, SD 0.018; single-lead sets: AUROC 0.768, SD 0.001). Considering the short amount of time needed to measure additional leads, measuring at least 3 leads—ideally more than 4 leads—is necessary for minimizing the risk of failing to detect acute myocardial infarction occurring in a certain spatial location or direction. Conclusions: By developing an AI model for detecting acute myocardial infarction with asynchronous ECG lead sets, we demonstrated the feasibility of multiple lead-based AI-enabled ECG algorithms on smartwatches for automated diagnosis of cardiac disorders. We also demonstrated the necessity of measuring at least 3 leads for accurate detection. Our results can be used as reference for the development of other AI models using sequentially measured asynchronous ECG leads via smartwatches for detecting various cardiac disorders.
- 10 September 2021
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 23 (9) , e31129
Open AccessAutomated Detection of Acute Myocardial Infarction Using Asynchronous Electrocardiogram Signals—Preview of Implementing Artificial Intelligence With Multichannel Electrocardiographs Obtained From Smartwatches: Retrospective Study
Background: When using a smartwatch to obtain electrocardiogram (ECG) signals from multiple leads, the device has to be placed on different parts of the body sequentially. The ECG signals measured from different leads are asynchronous. Artificial intelligence (AI) models for asynchronous ECG signals have barely been explored. Objective: We aimed to develop an AI model for detecting acute myocardial infarction using asynchronous ECGs and compare its performance with that of the automatic ECG interpretations provided by a commercial ECG analysis software. We sought to evaluate the feasibility of implementing multiple lead–based AI-enabled ECG algorithms on smartwatches. Moreover, we aimed to determine the optimal number of leads for sufficient diagnostic power. Methods: We extracted ECGs recorded within 24 hours from each visit to the emergency room of Ajou University Medical Center between June 1994 and January 2018 from patients aged 20 years or older. The ECGs were labeled on the basis of whether a diagnostic code corresponding to acute myocardial infarction was entered. We derived asynchronous ECG lead sets from standard 12-lead ECG reports and simulated a situation similar to the sequential recording of ECG leads via smartwatches. We constructed an AI model based on residual networks and self-attention mechanisms by randomly masking each lead channel during the training phase and then testing the model using various targeting lead sets with the remaining lead channels masked. Results: The performance of lead sets with 3 or more leads compared favorably with that of the automatic ECG interpretations provided by a commercial ECG analysis software, with 8.1%-13.9% gain in sensitivity when the specificity was matched. Our results indicate that multiple lead-based AI-enabled ECG algorithms can be implemented on smartwatches. Model performance generally increased as the number of leads increased (12-lead sets: area under the receiver operating characteristic curve [AUROC] 0.880; 4-lead sets: AUROC 0.858, SD 0.008; 3-lead sets: AUROC 0.845, SD 0.011; 2-lead sets: AUROC 0.813, SD 0.018; single-lead sets: AUROC 0.768, SD 0.001). Considering the short amount of time needed to measure additional leads, measuring at least 3 leads—ideally more than 4 leads—is necessary for minimizing the risk of failing to detect acute myocardial infarction occurring in a certain spatial location or direction. Conclusions: By developing an AI model for detecting acute myocardial infarction with asynchronous ECG lead sets, we demonstrated the feasibility of multiple lead-based AI-enabled ECG algorithms on smartwatches for automated diagnosis of cardiac disorders. We also demonstrated the necessity of measuring at least 3 leads for accurate detection. Our results can be used as reference for the development of other AI models using sequentially measured asynchronous ECG leads via smartwatches for detecting various cardiac disorders.
- Open Access
- 23 June 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Automated Detection of Acute Myocardial Infarction Using Asynchronous Electrocardiogram Signals—Preview of Implementing Artificial Intelligence With Multichannel Electrocardiographs Obtained From Smartwatches: Retrospective Study (Preprint)
BACKGROUND When using a smartwatch to obtain electrocardiogram (ECG) signals from multiple leads, the device has to be placed on different parts of the body sequentially. The ECG signals measured from different leads are asynchronous. Artificial intelligence (AI) models for asynchronous ECG signals have barely been explored. OBJECTIVE We aimed to develop an AI model for detecting acute myocardial infarction using asynchronous ECGs and compare its performance with that of the automatic ECG interpretations provided by a commercial ECG analysis software. We sought to evaluate the feasibility of implementing multiple lead–based AI-enabled ECG algorithms on smartwatches. Moreover, we aimed to determine the optimal number of leads for sufficient diagnostic power. METHODS We extracted ECGs recorded within 24 hours from each visit to the emergency room of Ajou University Medical Center between June 1994 and January 2018 from patients aged 20 years or older. The ECGs were labeled on the basis of whether a diagnostic code corresponding to acute myocardial infarction was entered. We derived asynchronous ECG lead sets from standard 12-lead ECG reports and simulated a situation similar to the sequential recording of ECG leads via smartwatches. We constructed an AI model based on residual networks and self-attention mechanisms by randomly masking each lead channel during the training phase and then testing the model using various targeting lead sets with the remaining lead channels masked. RESULTS The performance of lead sets with 3 or more leads compared favorably with that of the automatic ECG interpretations provided by a commercial ECG analysis software, with 8.1%-13.9% gain in sensitivity when the specificity was matched. Our results indicate that multiple lead-based AI-enabled ECG algorithms can be implemented on smartwatches. Model performance generally increased as the number of leads increased (12-lead sets: area under the receiver operating characteristic curve [AUROC] 0.880; 4-lead sets: AUROC 0.858, SD 0.008; 3-lead sets: AUROC 0.845, SD 0.011; 2-lead sets: AUROC 0.813, SD 0.018; single-lead sets: AUROC 0.768, SD 0.001). Considering the short amount of time needed to measure additional leads, measuring at least 3 leads—ideally more than 4 leads—is necessary for minimizing the risk of failing to detect acute myocardial infarction occurring in a certain spatial location or direction. CONCLUSIONS By developing an AI model for detecting acute myocardial infarction with asynchronous ECG lead sets, we demonstrated the feasibility of multiple lead-based AI-enabled ECG algorithms on smartwatches for automated diagnosis of cardiac disorders. We also demonstrated the necessity of measuring at least 3 leads for accurate detection. Our results can be used as reference for the development of other AI models using sequentially measured asynchronous ECG leads via smartwatches for detecting various cardiac disorders.
- 23 June 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAutomated Detection of Acute Myocardial Infarction Using Asynchronous Electrocardiogram Signals—Preview of Implementing Artificial Intelligence With Multichannel Electrocardiographs Obtained From Smartwatches: Retrospective Study (Preprint)
BACKGROUND When using a smartwatch to obtain electrocardiogram (ECG) signals from multiple leads, the device has to be placed on different parts of the body sequentially. The ECG signals measured from different leads are asynchronous. Artificial intelligence (AI) models for asynchronous ECG signals have barely been explored. OBJECTIVE We aimed to develop an AI model for detecting acute myocardial infarction using asynchronous ECGs and compare its performance with that of the automatic ECG interpretations provided by a commercial ECG analysis software. We sought to evaluate the feasibility of implementing multiple lead–based AI-enabled ECG algorithms on smartwatches. Moreover, we aimed to determine the optimal number of leads for sufficient diagnostic power. METHODS We extracted ECGs recorded within 24 hours from each visit to the emergency room of Ajou University Medical Center between June 1994 and January 2018 from patients aged 20 years or older. The ECGs were labeled on the basis of whether a diagnostic code corresponding to acute myocardial infarction was entered. We derived asynchronous ECG lead sets from standard 12-lead ECG reports and simulated a situation similar to the sequential recording of ECG leads via smartwatches. We constructed an AI model based on residual networks and self-attention mechanisms by randomly masking each lead channel during the training phase and then testing the model using various targeting lead sets with the remaining lead channels masked. RESULTS The performance of lead sets with 3 or more leads compared favorably with that of the automatic ECG interpretations provided by a commercial ECG analysis software, with 8.1%-13.9% gain in sensitivity when the specificity was matched. Our results indicate that multiple lead-based AI-enabled ECG algorithms can be implemented on smartwatches. Model performance generally increased as the number of leads increased (12-lead sets: area under the receiver operating characteristic curve [AUROC] 0.880; 4-lead sets: AUROC 0.858, SD 0.008; 3-lead sets: AUROC 0.845, SD 0.011; 2-lead sets: AUROC 0.813, SD 0.018; single-lead sets: AUROC 0.768, SD 0.001). Considering the short amount of time needed to measure additional leads, measuring at least 3 leads—ideally more than 4 leads—is necessary for minimizing the risk of failing to detect acute myocardial infarction occurring in a certain spatial location or direction. CONCLUSIONS By developing an AI model for detecting acute myocardial infarction with asynchronous ECG lead sets, we demonstrated the feasibility of multiple lead-based AI-enabled ECG algorithms on smartwatches for automated diagnosis of cardiac disorders. We also demonstrated the necessity of measuring at least 3 leads for accurate detection. Our results can be used as reference for the development of other AI models using sequentially measured asynchronous ECG leads via smartwatches for detecting various cardiac disorders.
- Open Access
- 31 January 2021
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 27 (1) , 19-28
Effectiveness of Transfer Learning for Deep Learning-Based Electrocardiogram Analysis
X: original ECG data;
- 31 January 2021
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 27 (1) , 19-28
Open AccessEffectiveness of Transfer Learning for Deep Learning-Based Electrocardiogram Analysis
X: original ECG data;
- Open Access
- 1 January 2021
- Published by XMLink in Journal of Korean Medical Science
- Vol. 36 (31) , e198
Machine Learning Approach for Active Vaccine Safety Monitoring
Kim Y, et al. J Korean Med Sci. 2021 Jul;36(31):e198. https://doi.org/10.3346/jkms.2021.36.e198
- 1 January 2021
- Published by XMLink in Journal of Korean Medical Science
- Vol. 36 (31) , e198
Open AccessMachine Learning Approach for Active Vaccine Safety Monitoring
Kim Y, et al. J Korean Med Sci. 2021 Jul;36(31):e198. https://doi.org/10.3346/jkms.2021.36.e198
- Open Access
- 1 August 2020
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 73 (4) , 275-284
Discovering hidden information in biosignals from patients using artificial intelligence
Biosignals such as electrocardiogram or photoplethysmogram are widely used for determining and monitoring the medical condition of patients. It was recently discovered that more information could be gathered from biosignals by applying artificial intelligence (AI). At present, one of the most impactful advancements in AI is deep learning. Deep learning-based models can extract important features from raw data without feature engineering by humans, provided the amount of data is sufficient. This AI-enabled feature presents opportunities to obtain latent information that may be used as a digital biomarker for detecting or predicting a clinical outcome or event without further invasive evaluation. However, the black box model of deep learning is difficult to understand for clinicians familiar with a conventional method of analysis of biosignals. A basic knowledge of AI and machine learning is required for the clinicians to properly interpret the extracted information and to adopt it in clinical practice. This review covers the basics of AI and machine learning, and the feasibility of their application to real-life situations by clinicians in the near future.
- 1 August 2020
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 73 (4) , 275-284
Open AccessDiscovering hidden information in biosignals from patients using artificial intelligence
Biosignals such as electrocardiogram or photoplethysmogram are widely used for determining and monitoring the medical condition of patients. It was recently discovered that more information could be gathered from biosignals by applying artificial intelligence (AI). At present, one of the most impactful advancements in AI is deep learning. Deep learning-based models can extract important features from raw data without feature engineering by humans, provided the amount of data is sufficient. This AI-enabled feature presents opportunities to obtain latent information that may be used as a digital biomarker for detecting or predicting a clinical outcome or event without further invasive evaluation. However, the black box model of deep learning is difficult to understand for clinicians familiar with a conventional method of analysis of biosignals. A basic knowledge of AI and machine learning is required for the clinicians to properly interpret the extracted information and to adopt it in clinical practice. This review covers the basics of AI and machine learning, and the feasibility of their application to real-life situations by clinicians in the near future.