Hanping Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hanping Mao has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ning Yang
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang 212013, China
2 shared publications Chen Pan
School of Electrical and Information Engineering Jiangsu University Zhenjiang China
1 shared publication- Chiyuan Chen
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang 212013, China
1 shared publication - Hussain Ahmad
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang 212013, China
1 shared publication - Junjie Yu
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang 212013, China
1 shared publication - Liangliang Xie
Faculty of Natural and Mathematics Science, King’s College London, Strand, London WC2R 2LS, UK
1 shared publication
Latest Publications
- Open Access
Pesticide Residues Identification by Optical Spectrum in the Time-Sequence of Enzyme Inhibitors Performed on Microfluidic Paper-Based Analytical Devices (µPADs)
Pesticides vary in the level of poisonousness, while a conventional rapid test card only provides a general “absence or not” solution, which cannot identify the various genera of pesticides. In order to solve this problem, we proposed a seven-layer paper-based microfluidic chip, integrating the enzyme acetylcholinesterase (AChE) and chromogenic reaction. It enables on-chip pesticide identification via a reflected light intensity spectrum in time-sequence according to the different reaction efficiencies of pesticide molecules and assures the optimum temperature for enzyme activity. After pretreatment of figures of reflected light intensity during the 15 min period, the figures mainly focused on the reflected light variations aroused by the enzyme inhibition assay, and thus, the linear discriminant analysis showed satisfying discrimination of imidacloprid (Y = −1.6525X − 139.7500), phorate (Y = −3.9689X − 483.0526), and avermectin (Y = −2.3617X − 28.3082). The correlation coefficients for these linearity curves were 0.9635, 0.8093, and 0.9094, respectively, with a 95% limit of agreement. Then, the avermectin class chemicals and real-world samples (i.e., lettuce and rice) were tested, which all showed feasible graphic results to distinguish all the chemicals. Therefore, it is feasible to distinguish the three tested kinds of pesticides by the changes in the reflected light spectrum in each min (15 min) via the proposed chip with a high level of automation and integration.
Open AccessPesticide Residues Identification by Optical Spectrum in the Time-Sequence of Enzyme Inhibitors Performed on Microfluidic Paper-Based Analytical Devices (µPADs)
Pesticides vary in the level of poisonousness, while a conventional rapid test card only provides a general “absence or not” solution, which cannot identify the various genera of pesticides. In order to solve this problem, we proposed a seven-layer paper-based microfluidic chip, integrating the enzyme acetylcholinesterase (AChE) and chromogenic reaction. It enables on-chip pesticide identification via a reflected light intensity spectrum in time-sequence according to the different reaction efficiencies of pesticide molecules and assures the optimum temperature for enzyme activity. After pretreatment of figures of reflected light intensity during the 15 min period, the figures mainly focused on the reflected light variations aroused by the enzyme inhibition assay, and thus, the linear discriminant analysis showed satisfying discrimination of imidacloprid (Y = −1.6525X − 139.7500), phorate (Y = −3.9689X − 483.0526), and avermectin (Y = −2.3617X − 28.3082). The correlation coefficients for these linearity curves were 0.9635, 0.8093, and 0.9094, respectively, with a 95% limit of agreement. Then, the avermectin class chemicals and real-world samples (i.e., lettuce and rice) were tested, which all showed feasible graphic results to distinguish all the chemicals. Therefore, it is feasible to distinguish the three tested kinds of pesticides by the changes in the reflected light spectrum in each min (15 min) via the proposed chip with a high level of automation and integration.
- Open Access
- 28 April 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (5) , 289
Portable Rice Disease Spores Capture and Detection Method Using Diffraction Fingerprints on Microfluidic Chip
Crop diseases cause great harm to food security, 90% of these are caused by fungal spores. This paper proposes a crop diseases spore detection method, based on the lensfree diffraction fingerprint and microfluidic chip. The spore diffraction images are obtained by a designed large field of view lensless diffraction detection platform which contains the spore enrichment microfluidic chip and lensless imaging module. By using the microfluidic chip to enrich and isolate spores in advance, the required particles can be captured in the chip enrichment area, and other impurities can be filtered to reduce the interference of impurities on spore detection. The light source emits partially coherent light and irradiates the target to generate diffraction fingerprints, which can be used to distinguish spores and impurities. According to the theoretical analysis, two parameters, Peak to Center ratio (PCR) and Peak to Valley ratio (PVR), are found to quantify these spores. The correlation coefficient between the detection results of rice blast spores by the constructed device and the results of microscopic artificial identification was up to 0.99, and the average error rate of the proposed device was only 5.91%. The size of the device is only 4 cm × 4 cm × 5 cm, and the cost is less than $150, which is one thousandth of the existing equipment. Therefore, it may be widely used as an early detection method for crop disease caused by spores.
- 28 April 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (5) , 289
Open AccessPortable Rice Disease Spores Capture and Detection Method Using Diffraction Fingerprints on Microfluidic Chip
Crop diseases cause great harm to food security, 90% of these are caused by fungal spores. This paper proposes a crop diseases spore detection method, based on the lensfree diffraction fingerprint and microfluidic chip. The spore diffraction images are obtained by a designed large field of view lensless diffraction detection platform which contains the spore enrichment microfluidic chip and lensless imaging module. By using the microfluidic chip to enrich and isolate spores in advance, the required particles can be captured in the chip enrichment area, and other impurities can be filtered to reduce the interference of impurities on spore detection. The light source emits partially coherent light and irradiates the target to generate diffraction fingerprints, which can be used to distinguish spores and impurities. According to the theoretical analysis, two parameters, Peak to Center ratio (PCR) and Peak to Valley ratio (PVR), are found to quantify these spores. The correlation coefficient between the detection results of rice blast spores by the constructed device and the results of microscopic artificial identification was up to 0.99, and the average error rate of the proposed device was only 5.91%. The size of the device is only 4 cm × 4 cm × 5 cm, and the cost is less than $150, which is one thousandth of the existing equipment. Therefore, it may be widely used as an early detection method for crop disease caused by spores.
- 18 December 2018
- Published by Wiley in Journal of Food Process Engineering
- Vol. 42 (2)
A novel on‐chip solution enabling rapid analysis of melamine and chloramphenicol in milk by smartphones
Ubiquitous food security control is desirable. However, the analysis methods, such as those for milk, are highly based on manual analysis, leading to low efficiency. Thus, we report a multilayer paper‐based microfluidic chip transforming chromatic readout to electric signals. First, colloidal gold immunochromatographic assays (GICA) are used to achieve the colorimetric occurrence. Secondly, the test (T) lines and control (C) lines are patterned to encode different EAN‐8 barcode. Furthermore, accurate scanning is accomplished by the automatic threshold segmentation. These technologies make the digital determination of melamine (MEL) and chloramphenicol (CAP) by phone readily accessible. Results indicate that the accurate machine‐scanning can be assured when MEL and CAP is above 30 ng/mL and 6 ng/mL in milk respectively. The detection time is under 8 min, and the stable storage life is over 90 days. Therefore, this simple chip allows rapid, machine‐readable, electric‐recordable diagnostic directly from chromatic assays with satisfying stability, specificity and accuracy.Practical applications: This article illustrates a method used to determine the concentration of melamine and chloramphenicol in milk. When melamine and chloramphenicol is above 30 and 6 ng/ml in milk, the produced EAN‐8 barcode can be recognized with high accurate level, compared with international standards, the results are acceptable and sensitive. This method is highly intellectual and environmentally friendly, with the disposable materials and instant smartphone‐readable EAN‐8 results patterns. This article demonstrates a multilayer paper chip based on EAN‐8 encoding rules, colloidal gold nanoparticles, and immunochromatographic assays. The EAN‐8 format assay is achieved by color‐development occurrence of colloidal GICA in different encoding areas of EAN‐8 code, and the analysis device, namely smartphone, is accessible by almost every individual. Therefore, this chip can pave a potential way for massive health control and digital automated analysis for daily life and industrial manufacture.
- 18 December 2018
- Published by Wiley in Journal of Food Process Engineering
- Vol. 42 (2)
A novel on‐chip solution enabling rapid analysis of melamine and chloramphenicol in milk by smartphones
Ubiquitous food security control is desirable. However, the analysis methods, such as those for milk, are highly based on manual analysis, leading to low efficiency. Thus, we report a multilayer paper‐based microfluidic chip transforming chromatic readout to electric signals. First, colloidal gold immunochromatographic assays (GICA) are used to achieve the colorimetric occurrence. Secondly, the test (T) lines and control (C) lines are patterned to encode different EAN‐8 barcode. Furthermore, accurate scanning is accomplished by the automatic threshold segmentation. These technologies make the digital determination of melamine (MEL) and chloramphenicol (CAP) by phone readily accessible. Results indicate that the accurate machine‐scanning can be assured when MEL and CAP is above 30 ng/mL and 6 ng/mL in milk respectively. The detection time is under 8 min, and the stable storage life is over 90 days. Therefore, this simple chip allows rapid, machine‐readable, electric‐recordable diagnostic directly from chromatic assays with satisfying stability, specificity and accuracy.Practical applications: This article illustrates a method used to determine the concentration of melamine and chloramphenicol in milk. When melamine and chloramphenicol is above 30 and 6 ng/ml in milk, the produced EAN‐8 barcode can be recognized with high accurate level, compared with international standards, the results are acceptable and sensitive. This method is highly intellectual and environmentally friendly, with the disposable materials and instant smartphone‐readable EAN‐8 results patterns. This article demonstrates a multilayer paper chip based on EAN‐8 encoding rules, colloidal gold nanoparticles, and immunochromatographic assays. The EAN‐8 format assay is achieved by color‐development occurrence of colloidal GICA in different encoding areas of EAN‐8 code, and the analysis device, namely smartphone, is accessible by almost every individual. Therefore, this chip can pave a potential way for massive health control and digital automated analysis for daily life and industrial manufacture.