Qiang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qiang Zhang has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Jin-Ming Lin
Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology (Ministry of Education), Tsinghua University, Beijing 100084, P. R. China
19 shared publications - Sifeng Mao
Department of Applied Chemistry Graduate School of Urban Environmental Sciences Tokyo Metropolitan University Tokyo 192‐0364 Japan
8 shared publications Shuo Feng
Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology (Ministry of Education), Department of Chemistry, Tsinghua University, Beijing 100084, China
6 shared publicationsTianze Xie
Department of Chemistry, Tshinghua University, Beijing 100084, China
6 shared publicationsWanling Zhang
Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
6 shared publicationsJiaxu Lin
Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology (Ministry of Education), Beijing Key Laboratory of Microanalysis Methods and Instrumentation, Department of Chemistry
4 shared publications
Latest Publications
- 3 June 2026
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 126 (12) , 7068-7111
Methods toward Single-Cell Total-Analysis
Single-cell total-analysis aims to bridge the gap between cellular molecular makeup and functional phenotype, deciphering how genomic, transcriptomic, proteomic, and metabolic networks orchestrate phenotypic outcomes. Despite rapid omics advances, a critical disconnect persists: nucleic acid-based analyses (genomics, epigenomics, transcriptomics) are mature, while proteomic/metabolomic profiling is incomplete, and comprehensive phenomics (the direct readout of cellular function) lags due to dynamic cellular complexity. This raises a core question: how to transcend isolated molecular layers to capture the ″molecular-phenotypic correlation″ in single cells? Multimodal integration progresses but is constrained by technical incompatibilities, throughput-depth trade-offs, and poor temporal resolution. This review examines advances in five core omics domains, identifies bottlenecks, analyzes multiomics coanalysis strategies, and outlines a roadmap for true single-cell total-analysis, emphasizing breakthrough approaches to unify molecular and phenotypic landscapes. We propose that true single-cell total-analysis is defined not by the accumulation of multiomic molecular layers, but by the direct establishment of phenotype-component correlations within the same individual cell.
- 3 June 2026
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 126 (12) , 7068-7111
Methods toward Single-Cell Total-Analysis
Single-cell total-analysis aims to bridge the gap between cellular molecular makeup and functional phenotype, deciphering how genomic, transcriptomic, proteomic, and metabolic networks orchestrate phenotypic outcomes. Despite rapid omics advances, a critical disconnect persists: nucleic acid-based analyses (genomics, epigenomics, transcriptomics) are mature, while proteomic/metabolomic profiling is incomplete, and comprehensive phenomics (the direct readout of cellular function) lags due to dynamic cellular complexity. This raises a core question: how to transcend isolated molecular layers to capture the ″molecular-phenotypic correlation″ in single cells? Multimodal integration progresses but is constrained by technical incompatibilities, throughput-depth trade-offs, and poor temporal resolution. This review examines advances in five core omics domains, identifies bottlenecks, analyzes multiomics coanalysis strategies, and outlines a roadmap for true single-cell total-analysis, emphasizing breakthrough approaches to unify molecular and phenotypic landscapes. We propose that true single-cell total-analysis is defined not by the accumulation of multiomic molecular layers, but by the direct establishment of phenotype-component correlations within the same individual cell.
- 24 March 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1776, 466931
An integrated derivatization-LC-MS strategy reveals cell-type-specific chiral amino acid profiles
- 24 March 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1776, 466931
An integrated derivatization-LC-MS strategy reveals cell-type-specific chiral amino acid profiles
- 21 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (34) , 18689-18696
Dean Flow-Assisted Microfluidic Aqueous Two-Phase Extraction for Purifying Extracellular Vesicles and Facilitating Single-Vesicle Analysis
Extracellular vesicles (EVs) play a crucial role in mediating and regulating biological processes, such as intercellular communication and signaling. The isolation and purification of EVs from biological samples are prerequisites for EV research. Herein, a Dean flow-assisted microfluidic aqueous two-phase extraction chip (DATPEC) was developed for isolating EVs from biological samples. In aqueous two-phase laminar flow, EVs with hydrophilic surfaces selectively migrate from the poly(ethylene glycol) (PEG) phase to the dextran (DEX) phase, which is accelerated by Dean flow. However, the proteins were still retained in the PEG phase due to the laminar effect and their surface properties. The separation performance of the DATPEC was investigated using breast cancer-derived EVs, and 91.1% EVs could be recovered from the cell culture medium supernatant with a protein removal rate of 95.6%. As a proof of concept, this technique was coupled with total internal reflection fluorescence (TIRF) microscopy to analyze surface proteins (EpCAM and EGFR) of EVs derived from eight cell lines. Fluorescent aptamers were specifically labeled on EVs, revealing the single-vesicle heterogeneity. In conclusion, DATPEC enables simple and efficient separation of high-purity EVs and exhibits the potential to be integrated with downstream techniques for EV analysis.
- 21 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (34) , 18689-18696
Dean Flow-Assisted Microfluidic Aqueous Two-Phase Extraction for Purifying Extracellular Vesicles and Facilitating Single-Vesicle Analysis
Extracellular vesicles (EVs) play a crucial role in mediating and regulating biological processes, such as intercellular communication and signaling. The isolation and purification of EVs from biological samples are prerequisites for EV research. Herein, a Dean flow-assisted microfluidic aqueous two-phase extraction chip (DATPEC) was developed for isolating EVs from biological samples. In aqueous two-phase laminar flow, EVs with hydrophilic surfaces selectively migrate from the poly(ethylene glycol) (PEG) phase to the dextran (DEX) phase, which is accelerated by Dean flow. However, the proteins were still retained in the PEG phase due to the laminar effect and their surface properties. The separation performance of the DATPEC was investigated using breast cancer-derived EVs, and 91.1% EVs could be recovered from the cell culture medium supernatant with a protein removal rate of 95.6%. As a proof of concept, this technique was coupled with total internal reflection fluorescence (TIRF) microscopy to analyze surface proteins (EpCAM and EGFR) of EVs derived from eight cell lines. Fluorescent aptamers were specifically labeled on EVs, revealing the single-vesicle heterogeneity. In conclusion, DATPEC enables simple and efficient separation of high-purity EVs and exhibits the potential to be integrated with downstream techniques for EV analysis.
- 28 March 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (10) , 2146-2152
A teicoplanin-cyclodextrin bilayer chiral stationary phase boosts chiral separation of native amino acids
A teicoplanin-cyclodextrin bilayer chiral stationary phase (TK-CD-6 CSP) outperforms TK CSP and TK + CD CSP, with better amino acid separation and a broader range of separable species.
- 28 March 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (10) , 2146-2152
A teicoplanin-cyclodextrin bilayer chiral stationary phase boosts chiral separation of native amino acids
A teicoplanin-cyclodextrin bilayer chiral stationary phase (TK-CD-6 CSP) outperforms TK CSP and TK + CD CSP, with better amino acid separation and a broader range of separable species.
- 26 April 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (18) , 22958-22965
Chemical Plasma Membrane Perforation Generated by a Microfluidic Probe for Single-Cell Intracellular Protein Delivery
Efficient and convenient delivery of exogenous molecules into cells is important for cell biology research. However, many intracellular delivery methods require carrier-mediated or physical field assistance, complicating the delivery process. Here, a general, simple, and effective method for in situ single-cell intracellular delivery is reported. A solution containing digitonin and cargo is precisely applied to single cells using a microfluidic probe. Digitonin binds to cholesterol in the plasma membrane to induce perforation, and the cargo enters the cell through the pore. By optimizing parameters, propidium iodide (0.67 kDa) and FITC-dextran (10, 40, and 150 kDa) can be successfully introduced into single cells within 3 min while maintaining cell viability. To prove the potential of this method for cell research, we delivered cytochrome C (13 kDa) and cyclophilin A (18 kDa) into cells by this method. The delivered cytochrome C successfully induces cell apoptosis by activating the caspase pathway, and cyclophilin A performs an antioxidant effect in the cells, which may enhance the drug resistance of glioma cells. It is believed that this method will be an attractive tool for single-cell intracellular delivery.
- 26 April 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (18) , 22958-22965
Chemical Plasma Membrane Perforation Generated by a Microfluidic Probe for Single-Cell Intracellular Protein Delivery
Efficient and convenient delivery of exogenous molecules into cells is important for cell biology research. However, many intracellular delivery methods require carrier-mediated or physical field assistance, complicating the delivery process. Here, a general, simple, and effective method for in situ single-cell intracellular delivery is reported. A solution containing digitonin and cargo is precisely applied to single cells using a microfluidic probe. Digitonin binds to cholesterol in the plasma membrane to induce perforation, and the cargo enters the cell through the pore. By optimizing parameters, propidium iodide (0.67 kDa) and FITC-dextran (10, 40, and 150 kDa) can be successfully introduced into single cells within 3 min while maintaining cell viability. To prove the potential of this method for cell research, we delivered cytochrome C (13 kDa) and cyclophilin A (18 kDa) into cells by this method. The delivered cytochrome C successfully induces cell apoptosis by activating the caspase pathway, and cyclophilin A performs an antioxidant effect in the cells, which may enhance the drug resistance of glioma cells. It is believed that this method will be an attractive tool for single-cell intracellular delivery.
- 30 November 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (49) , 18082-18090
Microfluidic Sampling of Undissolved Components from Subcellular Regions of Living Single Cells for Mass Spectrometry Analysis
Precise sampling of undissolved chemical components from subcellular regions of living single cells is a prerequisite for their in-depth analysis, which could promote understanding of subtle early stage physiological or pathological processes. Here we report a microfluidic method to extract undissolved components from subcellular regions for MS analysis. The target single cell was isolated by the microchamber beneath the microfluidic probe and washed by the injected biocompatible isotonic glucose aqueous solution (IGAS). Then, the sampling solvent was injected to extract undissolved components from the expected subcellular region of the living single cell, where the position and size of the sampling region could be controlled. The components immobilized by undissolved cellular structures were proven to be successfully extracted. Since unextracted subcellular regions were protected by IGAS, the single cell could survive after a tiny part was extracted, providing the possibility of repetitive sampling of the same living cell. Phospholipids extracted from the subcellular regions were successfully identified. The results demonstrated the feasibility of our method for subcellular sampling and analysis.
- 30 November 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (49) , 18082-18090
Microfluidic Sampling of Undissolved Components from Subcellular Regions of Living Single Cells for Mass Spectrometry Analysis
Precise sampling of undissolved chemical components from subcellular regions of living single cells is a prerequisite for their in-depth analysis, which could promote understanding of subtle early stage physiological or pathological processes. Here we report a microfluidic method to extract undissolved components from subcellular regions for MS analysis. The target single cell was isolated by the microchamber beneath the microfluidic probe and washed by the injected biocompatible isotonic glucose aqueous solution (IGAS). Then, the sampling solvent was injected to extract undissolved components from the expected subcellular region of the living single cell, where the position and size of the sampling region could be controlled. The components immobilized by undissolved cellular structures were proven to be successfully extracted. Since unextracted subcellular regions were protected by IGAS, the single cell could survive after a tiny part was extracted, providing the possibility of repetitive sampling of the same living cell. Phospholipids extracted from the subcellular regions were successfully identified. The results demonstrated the feasibility of our method for subcellular sampling and analysis.
- 21 September 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (39) , 45640-45650
Microfluidic Aqueous Two-Phase Focusing of Chemical Species for In Situ Subcellular Stimulation
Confinement of chemical species in a controllable micrometer-level (several to a dozen micrometers) space in an aqueous environment is essential for precisely manipulating chemical events in subcellular regions. However, rapid diffusion and hard-to-control micrometer-level fluids make it a tough challenge. Here, a versatile open microfluidic method based on an aqueous two-phase system (ATPS) is developed to restrict species inside an open space with micron-level width. Unequal standard chemical potentials of the chemical species in two phases and space-time correspondence in the microfluidic system prevent outward diffusion across the phase interface, retaining the target species inside its preferred phase flow and creating a sharp boundary with a dramatic concentration change. Then, the chemical flow (the preferred phase with target chemical species) is precisely manipulated by a microfluidic probe, which can be compressed to a micron-level width and aimed at an arbitrary position of the sample. As a demonstration of the feasibility and versatility of the strategy, chemical flow is successfully applied to subcellular regions of various kinds of living single cells. Subcellular regions are successfully labeled (cytomembrane and mitochondria) and damaged. Healing-regeneration behaviors of living single cells are triggered by subcellular damage and analyzed. The method is relatively general regarding the species of chemicals and biosamples, which could promote deeper cell research.
- 21 September 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (39) , 45640-45650
Microfluidic Aqueous Two-Phase Focusing of Chemical Species for In Situ Subcellular Stimulation
Confinement of chemical species in a controllable micrometer-level (several to a dozen micrometers) space in an aqueous environment is essential for precisely manipulating chemical events in subcellular regions. However, rapid diffusion and hard-to-control micrometer-level fluids make it a tough challenge. Here, a versatile open microfluidic method based on an aqueous two-phase system (ATPS) is developed to restrict species inside an open space with micron-level width. Unequal standard chemical potentials of the chemical species in two phases and space-time correspondence in the microfluidic system prevent outward diffusion across the phase interface, retaining the target species inside its preferred phase flow and creating a sharp boundary with a dramatic concentration change. Then, the chemical flow (the preferred phase with target chemical species) is precisely manipulated by a microfluidic probe, which can be compressed to a micron-level width and aimed at an arbitrary position of the sample. As a demonstration of the feasibility and versatility of the strategy, chemical flow is successfully applied to subcellular regions of various kinds of living single cells. Subcellular regions are successfully labeled (cytomembrane and mitochondria) and damaged. Healing-regeneration behaviors of living single cells are triggered by subcellular damage and analyzed. The method is relatively general regarding the species of chemicals and biosamples, which could promote deeper cell research.
- 13 September 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (24)
In Situ Time‐Controllable Chemical Plasma Membrane Injury by Microfluidic Probe Reveals Self‐Repair Ability of Single Cells
The loss of plasma membrane integrity poses a serious threat to cells, and the plasma membrane repair mechanism is vital to cell survival. To investigate the plasma membrane repair mechanism, a method for causing controllable plasma membrane injury on single cells and the visualization of the plasma membrane repair process are proposed. A microregion with harmful chemicals is created by open microfluidic probe, which is applied to target single cells for injury. The injury time is precisely controlled by simply moving the target cells in and out of the microregion. Wound‐repair process caused by injury is analyzed by fluorescence imaging in real time, revealing the repair kinetics at the single cell level. Using this method, the effect of external conditions (Ca2+, Mg2+, glucose) on plasma membrane repair in single cells is studied and the dynamics of intracellular species (Ca2+) is monitored. Meanwhile, cellular heterogeneity of plasma membrane repair is revealed. This method provides a precise way to induce chemical plasma membrane injury at the single‐cell level, which is a promising tool to study the mechanism of plasma membrane repair.
- 13 September 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (24)
In Situ Time‐Controllable Chemical Plasma Membrane Injury by Microfluidic Probe Reveals Self‐Repair Ability of Single Cells
The loss of plasma membrane integrity poses a serious threat to cells, and the plasma membrane repair mechanism is vital to cell survival. To investigate the plasma membrane repair mechanism, a method for causing controllable plasma membrane injury on single cells and the visualization of the plasma membrane repair process are proposed. A microregion with harmful chemicals is created by open microfluidic probe, which is applied to target single cells for injury. The injury time is precisely controlled by simply moving the target cells in and out of the microregion. Wound‐repair process caused by injury is analyzed by fluorescence imaging in real time, revealing the repair kinetics at the single cell level. Using this method, the effect of external conditions (Ca2+, Mg2+, glucose) on plasma membrane repair in single cells is studied and the dynamics of intracellular species (Ca2+) is monitored. Meanwhile, cellular heterogeneity of plasma membrane repair is revealed. This method provides a precise way to induce chemical plasma membrane injury at the single‐cell level, which is a promising tool to study the mechanism of plasma membrane repair.
- 23 August 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (35) , 13391-13399
Nanozyme-Mediated Catalytic Signal Amplification for Microfluidic Biosensing of Foodborne Bacteria
Early detection of foodborne bacteria is urgently needed to ensure food quality and to avoid the outbreak of foodborne bacterial diseases. Here, a kind of metal-organic framework (Zr-MOF) modified with Pt nanoparticles (Pt-PCN-224) was designed as a peroxidase-like signal amplifier for microfluidic biosensing of foodborne bacteria. Taking Escherichia coli (E. coli) O157:H7 as a model, a linear range from 2.93 × 102 to 2.93 × 108 CFU/mL and a limit of detection of 2 CFU/mL were obtained. The whole detection procedure was integrated into a single microfluidic chip. Water, milk, and cabbage samples were successfully detected, showing consistency with the results of the standard culture method. Recoveries were in the range from 90 to 110% in spiked testing. The proposed microfluidic biosensor realized the specific and sensitive detection of E. coli O157:H7 within 1 h, implying broad prospects of MOF with biomimetic enzyme activities for biosensing.
- 23 August 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (35) , 13391-13399
Nanozyme-Mediated Catalytic Signal Amplification for Microfluidic Biosensing of Foodborne Bacteria
Early detection of foodborne bacteria is urgently needed to ensure food quality and to avoid the outbreak of foodborne bacterial diseases. Here, a kind of metal-organic framework (Zr-MOF) modified with Pt nanoparticles (Pt-PCN-224) was designed as a peroxidase-like signal amplifier for microfluidic biosensing of foodborne bacteria. Taking Escherichia coli (E. coli) O157:H7 as a model, a linear range from 2.93 × 102 to 2.93 × 108 CFU/mL and a limit of detection of 2 CFU/mL were obtained. The whole detection procedure was integrated into a single microfluidic chip. Water, milk, and cabbage samples were successfully detected, showing consistency with the results of the standard culture method. Recoveries were in the range from 90 to 110% in spiked testing. The proposed microfluidic biosensor realized the specific and sensitive detection of E. coli O157:H7 within 1 h, implying broad prospects of MOF with biomimetic enzyme activities for biosensing.
- 19 January 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (4) , 2321-2328
Microfluidic Mixer for In Situ Ammonia Analysis of Single Cells in Mass Spectrometry
Mass spectrometry (MS) is a powerful tool for exploring single-cell heterogeneity. However, due to the ultralow absolute content of most substances in a single cell, existing methods can only analyze high-content substances; conventional methods are incompetent for quantitative analysis of important trace-amount small-molecule metabolites such as ammonia and sulfide. Herein, a method integrating single-cell extraction, online derivatization, and MS for multifunctional and more accurate MS analysis is reported. For application, ammonia content in a single cell was analyzed, where the cellular heterogeneity in ammonia metabolism was revealed. First, the extraction room of a microfluidic probe was covered on the target single cell, and the extraction fluid was allowed to flow through a single cell and dissolve cellular ammonia. Then, the ammonia was mixed and reacted with the pretreatment reagent input from another inlet to achieve the derivatization and signal amplification, enhancing the analysis sensitivity on MS. Finally, the sample was sent to MS, and the ammonia content was successfully quantitatively evaluated by analyzing its derivative urotropine, demonstrating the potential of this method to advance single-cell mass spectrometry analysis to higher sensitivity.
- 19 January 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (4) , 2321-2328
Microfluidic Mixer for In Situ Ammonia Analysis of Single Cells in Mass Spectrometry
Mass spectrometry (MS) is a powerful tool for exploring single-cell heterogeneity. However, due to the ultralow absolute content of most substances in a single cell, existing methods can only analyze high-content substances; conventional methods are incompetent for quantitative analysis of important trace-amount small-molecule metabolites such as ammonia and sulfide. Herein, a method integrating single-cell extraction, online derivatization, and MS for multifunctional and more accurate MS analysis is reported. For application, ammonia content in a single cell was analyzed, where the cellular heterogeneity in ammonia metabolism was revealed. First, the extraction room of a microfluidic probe was covered on the target single cell, and the extraction fluid was allowed to flow through a single cell and dissolve cellular ammonia. Then, the ammonia was mixed and reacted with the pretreatment reagent input from another inlet to achieve the derivatization and signal amplification, enhancing the analysis sensitivity on MS. Finally, the sample was sent to MS, and the ammonia content was successfully quantitatively evaluated by analyzing its derivative urotropine, demonstrating the potential of this method to advance single-cell mass spectrometry analysis to higher sensitivity.