Arata Nishimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arata Nishimura has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Yoshimitsu Hishinuma
Department of Helical Plasma Research, National Institute for Fusion Science, Toki, JAPAN
5 shared publicationsShuji Yoshizawa
Advanced Materials R&D Center, Meisei University, 2-1-1 Hodokubo, Hino, Tokyo 191-8506, Japan
3 shared publications- Akiyoshi Matsumoto
National Institute for Materials Science
1 shared publication Gen Nishijima
IMR, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai, Miyagi 980-8577, Japan
1 shared publicationH Miyata
Japan Superconductor Technology, Inc. Kobe, Hyogo 651-2271 Japan
1 shared publicationHidetoshi Oguro
Tokai University, Hiratsuka City, Japan
1 shared publication
Latest Publications
- Open Access
- 16 August 2026
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 48
Conceptual design of vacuum vessel and welding joint between vacuum vessel sectors for a torus fusion reactor
- 16 August 2026
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 48
Open AccessConceptual design of vacuum vessel and welding joint between vacuum vessel sectors for a torus fusion reactor
- 10 January 2019
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 32 (2) , 024004
Effect of neutron irradiation on Nb 3 Sn wire
A Nb 3 Sn wire which was manufactured for the ITER toroidal field coil conductor by a bronze route process was prepared for this study to investigate the effect of neutron irradiation on the critical current in a high magnetic field. The critical current of the virgin wire was measured in liquid helium with a 28 T hybrid superconducting magnet at the High Field Laboratory for Superconducting Materials in Tohoku University. It was also measured in vacuum with a heat conduction type variable temperature insert (VTI) at the International Research Center for Nuclear Materials Science at Tohoku University. The wire was irradiated at below 100 °C by fission neutrons at up to 4.9 × 10 22 neutrons m −2 (>0.1 MeV) at BR2 in Belgium, and the critical current after the irradiation was evaluated with a VTI in the range of 8–15.5 T. The difference of the critical current measured with two facilities was discussed, focussing on Joule heating of the sample holder which was made of pure copper, and the neutron irradiation effect on the critical current was investigated in the range of up to 15.5 T. The results show that the critical current measured in vacuum becomes lower than that in liquid helium because of the temperature rise of the sample holder where the sample was soldered, the critical current was increased by the neutron irradiation, and the current ratio (I C /I C0 ) was almost constant of 1.75 in the range of 8–15.5 T at around 4 K.
- 10 January 2019
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 32 (2) , 024004
Effect of neutron irradiation on Nb 3 Sn wire
A Nb 3 Sn wire which was manufactured for the ITER toroidal field coil conductor by a bronze route process was prepared for this study to investigate the effect of neutron irradiation on the critical current in a high magnetic field. The critical current of the virgin wire was measured in liquid helium with a 28 T hybrid superconducting magnet at the High Field Laboratory for Superconducting Materials in Tohoku University. It was also measured in vacuum with a heat conduction type variable temperature insert (VTI) at the International Research Center for Nuclear Materials Science at Tohoku University. The wire was irradiated at below 100 °C by fission neutrons at up to 4.9 × 10 22 neutrons m −2 (>0.1 MeV) at BR2 in Belgium, and the critical current after the irradiation was evaluated with a VTI in the range of 8–15.5 T. The difference of the critical current measured with two facilities was discussed, focussing on Joule heating of the sample holder which was made of pure copper, and the neutron irradiation effect on the critical current was investigated in the range of up to 15.5 T. The results show that the critical current measured in vacuum becomes lower than that in liquid helium because of the temperature rise of the sample holder where the sample was soldered, the critical current was increased by the neutron irradiation, and the current ratio (I C /I C0 ) was almost constant of 1.75 in the range of 8–15.5 T at around 4 K.
- Open Access
- 10 April 2018
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 13, 3405023
Several Considerations on Construction Site of Fusion DEMO
A fusion reactor is a human dream aiming to realize a terrestrial sun. The ITER project has been running for over ten years to create D-T burning plasma. Since a fusion DEMO design started within a framework of all-Japan system newly established in Japan, the construction site of the fusion DEMO must be investigated based on the discussions which have been performed for a long time in wide engineering fields. Some of the requirements to the site selection are discussed and summarized. The discussions are mainly focused on infrastructure which will be required to the construction site and very long timespan has been imaged from the construction to the site close after the D-T burning plasma operations. The plasma parameters and the in-vessel systems like the blanket and the diverter will not be discussed and the reactor type, such as Tokamak or Helical, is not concerned severely.
- 10 April 2018
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 13, 3405023
Open AccessSeveral Considerations on Construction Site of Fusion DEMO
A fusion reactor is a human dream aiming to realize a terrestrial sun. The ITER project has been running for over ten years to create D-T burning plasma. Since a fusion DEMO design started within a framework of all-Japan system newly established in Japan, the construction site of the fusion DEMO must be investigated based on the discussions which have been performed for a long time in wide engineering fields. Some of the requirements to the site selection are discussed and summarized. The discussions are mainly focused on infrastructure which will be required to the construction site and very long timespan has been imaged from the construction to the site close after the D-T burning plasma operations. The plasma parameters and the in-vessel systems like the blanket and the diverter will not be discussed and the reactor type, such as Tokamak or Helical, is not concerned severely.
- Open Access
- 30 December 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 279 (1) , 012029
A high field and cryogenic test facility for neutron irradiated superconducting wire
A 15.5 T superconducting magnet and a variable temperature insert (VTI) system were installed at a radiation control area in Oarai center in Tohoku University to investigate the superconducting properties of activated superconducting materials by fast neutron. The superconductivity was measured at cryogenic temperature and high magnetic field. During these tests, some inconvenient problems were observed and the additional investigation was carried out. The variable temperature insert was designed and assembled to perform the superconducting property tests. without the liquid helium. To remove the heat induced by radiation and joule heating, high purity aluminum rod was used in VTI. The thermal contact was checked by FEM analysis and an additional support was added to confirm the decreasing the stress concentration and the good thermal contact. After the work for improvement, it was affirmed that the test system works well and all troubles were resolved. In this report, the improved technical solution is described and the first data set on the irradiation effect on Nb3Sn wire is presented.
- 30 December 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 279 (1) , 012029
Open AccessA high field and cryogenic test facility for neutron irradiated superconducting wire
A 15.5 T superconducting magnet and a variable temperature insert (VTI) system were installed at a radiation control area in Oarai center in Tohoku University to investigate the superconducting properties of activated superconducting materials by fast neutron. The superconductivity was measured at cryogenic temperature and high magnetic field. During these tests, some inconvenient problems were observed and the additional investigation was carried out. The variable temperature insert was designed and assembled to perform the superconducting property tests. without the liquid helium. To remove the heat induced by radiation and joule heating, high purity aluminum rod was used in VTI. The thermal contact was checked by FEM analysis and an additional support was added to confirm the decreasing the stress concentration and the good thermal contact. After the work for improvement, it was affirmed that the test system works well and all troubles were resolved. In this report, the improved technical solution is described and the first data set on the irradiation effect on Nb3Sn wire is presented.
- 1 January 2012
- Published by AIP Publishing in AIP Conference Proceedings
Radiation effect on interlaminar shear strength of the electric insulation system with cyanate ester and epoxy blended resin
A fusion reactor will generate a lot of fast neutrons which will activate the materials in the reactor. Since fusion neutrons will reach superconducting magnets and the activated materials will emit a gamma ray, the materials in the reactor will be exposed by the neutron and the gamma ray at the same time. The weakest material against radiation exposure is an organic material for an electric insulation. Cyanate ester resin has been proposed as a candidate material for the insulation system of ITER and it is clarified that the blended resin with epoxy has a potential to survive a design period in the radiation environment. In this study, a molecular structure analysis of the blended resin was carried out and heat flux measurements by differential scanning calorimetry and interlaminar shear strength (ILSS) tests at 77 K were performed using irradiated samples with the gamma ray and neutrons. The results show that a triazine ring which has excellent resistance against radiation is formed during the curing process and the insulation composite material with 100% cyanate resin shows almost no degradation after irradiation of over 400 MGy.
- 1 January 2012
- Published by AIP Publishing in AIP Conference Proceedings
Radiation effect on interlaminar shear strength of the electric insulation system with cyanate ester and epoxy blended resin
A fusion reactor will generate a lot of fast neutrons which will activate the materials in the reactor. Since fusion neutrons will reach superconducting magnets and the activated materials will emit a gamma ray, the materials in the reactor will be exposed by the neutron and the gamma ray at the same time. The weakest material against radiation exposure is an organic material for an electric insulation. Cyanate ester resin has been proposed as a candidate material for the insulation system of ITER and it is clarified that the blended resin with epoxy has a potential to survive a design period in the radiation environment. In this study, a molecular structure analysis of the blended resin was carried out and heat flux measurements by differential scanning calorimetry and interlaminar shear strength (ILSS) tests at 77 K were performed using irradiated samples with the gamma ray and neutrons. The results show that a triazine ring which has excellent resistance against radiation is formed during the curing process and the insulation composite material with 100% cyanate resin shows almost no degradation after irradiation of over 400 MGy.
- 5 November 2010
- Published by Elsevier in Fusion Engineering and Design
- Vol. 86 (2) , 134-140
Feasibility study on cryogenic irradiation facility in JMTR
- 5 November 2010
- Published by Elsevier in Fusion Engineering and Design
- Vol. 86 (2) , 134-140
Feasibility study on cryogenic irradiation facility in JMTR
- 1 November 2005
- Published by Elsevier in Fusion Engineering and Design
- Vol. 75-79, 173-177
Design, fabrication and installation of cryogenic target system for 14MeV neutron irradiation on superconducting magnet materials
- 1 November 2005
- Published by Elsevier in Fusion Engineering and Design
- Vol. 75-79, 173-177
Design, fabrication and installation of cryogenic target system for 14MeV neutron irradiation on superconducting magnet materials
- 4 August 2003
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 16 (9) , 980-983
Three-point bending fracture behaviour of Bi-2223 bulk composed of Ag wire and its critical current after fracture
Silver wires were composed to Bi-2223 bulk to improve transport current property and fracture behaviour. The Bi-2223/Ag wire bulk prepared was 5 mm wide, 22 mm long and a few millimetres thick depending on the Ag wire content. The mechanical property was investigated using the three-point bending test, and an interlaminar fracture and a bending fracture were observed. The bonding strength on the interface of the silver and Bi-2223 matrix can affect the fracture mode. The composed samples did not separate into small pieces and the cracked sample showed superconductivity at 77 K.
- 4 August 2003
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 16 (9) , 980-983
Three-point bending fracture behaviour of Bi-2223 bulk composed of Ag wire and its critical current after fracture
Silver wires were composed to Bi-2223 bulk to improve transport current property and fracture behaviour. The Bi-2223/Ag wire bulk prepared was 5 mm wide, 22 mm long and a few millimetres thick depending on the Ag wire content. The mechanical property was investigated using the three-point bending test, and an interlaminar fracture and a bending fracture were observed. The bonding strength on the interface of the silver and Bi-2223 matrix can affect the fracture mode. The composed samples did not separate into small pieces and the cracked sample showed superconductivity at 77 K.
- 13 June 2003
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 16 (8) , 845-851
Fabrication and superconductivity of BPSCCO-2223 oxide bulk by a new design composite
We have studied a newly designed BPSCCO-2223 bulk composed of mono-cored BPSCCO-2223/Ag sheath filaments. The composite structure design of the combination of BPSCCO-2223 and mono-cored filaments was newly developed with the aim of protection when bulk material is used as a current feeder for large-scale applications. The composites were made by alternately stacking BPSCCO-2223 oxide-cored Ag sheath filaments and the oxide powder by the powder-in-tube (PIT) method, and then the prepared samples were sintered at 840 °C for 50 h. Then, a cold isosatic pressing (CIP) process was applied and they were re-sintered at 840 °C for 50 h. As a result, the maximum transport current (Ic) value of the composite bulk, which is composed of 24 mono-cored sheath filaments of 0.4 mm in diameter, was estimated to be about 240 A at 4.2 K and 0 T. This Ic value was about three times higher than that of a conventional bulk, and the value of the PIT filaments composite bulk was also higher than that of the Ag wires composite bulk. This is why good c-axis oriented and densely structured BPSCCO-2223 plate-like grains were formed on both the outer and inner interface between the oxide and Ag in the PIT filaments. Furthermore, we confirmed that transport current was flowed into the PIT filaments composite bulk after forcing a fracture by the bending test. We guessed that the PIT filaments could act as a bypass for the fracture of the bulk. We thought that a new design of the composite bulk in this study was interesting in terms of safety precautions for large-scale applications.
- 13 June 2003
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 16 (8) , 845-851
Fabrication and superconductivity of BPSCCO-2223 oxide bulk by a new design composite
We have studied a newly designed BPSCCO-2223 bulk composed of mono-cored BPSCCO-2223/Ag sheath filaments. The composite structure design of the combination of BPSCCO-2223 and mono-cored filaments was newly developed with the aim of protection when bulk material is used as a current feeder for large-scale applications. The composites were made by alternately stacking BPSCCO-2223 oxide-cored Ag sheath filaments and the oxide powder by the powder-in-tube (PIT) method, and then the prepared samples were sintered at 840 °C for 50 h. Then, a cold isosatic pressing (CIP) process was applied and they were re-sintered at 840 °C for 50 h. As a result, the maximum transport current (Ic) value of the composite bulk, which is composed of 24 mono-cored sheath filaments of 0.4 mm in diameter, was estimated to be about 240 A at 4.2 K and 0 T. This Ic value was about three times higher than that of a conventional bulk, and the value of the PIT filaments composite bulk was also higher than that of the Ag wires composite bulk. This is why good c-axis oriented and densely structured BPSCCO-2223 plate-like grains were formed on both the outer and inner interface between the oxide and Ag in the PIT filaments. Furthermore, we confirmed that transport current was flowed into the PIT filaments composite bulk after forcing a fracture by the bending test. We guessed that the PIT filaments could act as a bypass for the fracture of the bulk. We thought that a new design of the composite bulk in this study was interesting in terms of safety precautions for large-scale applications.