Tamon Kusumoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tamon Kusumoto has a total of 274 co-authors. Here are the top co-authors by number of shared publications:
Satoshi Kodaira
9 shared publications- Satoshi Kodaira
National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
7 shared publications Tomoya Yamauchi
5 shared publicationsMasato Kanasaki
4 shared publicationsRémi Barillon
Institute Pluridisiplinaire Hubert Curien, 23 Rue du Loess, 67037, Strasbourg, Cedex 2, France
4 shared publications- Teruaki Konishi
National Institutes for Quantum Science and Technology (QST), 4-9-1 Anagawa, Inage-ku, 263-8555 Chiba, Japan
4 shared publications
Latest Publications
- Open Access
- 2 September 2025
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 101 (11) , 1129-1134
Changes in yields of oxidative damages 8-hydroxy-2′-deoxyguanosine in the presence of gold nanoparticles under X-rays, protons and heavy ions
To clarify the mechanisms of GNPs radiosensitizing effects, we investigated changes in yields of 8-hydroxy-2'-deoxyguanosine (8-OHdG), which is an oxidative damage marker and generated by reactions of 2'-deoxyguanosine (dG) with OH radicals in aqueous solutions. Aqueous dG (Sigma Aldrich) solutions (500 μM) are irradiated with X-rays, protons and heavy ions in a wide LET range. The examined LET range is from about 2 to 600 eV/nm. After the irradiation, electrochemical detectors connected to HPLC system are employed to quantitatively evaluate changes in yields of 8-OHdG in the presence and in the absence of GNPs. The size of GNPs applied is a gold core diameter of between 2 and 3 nm. The G value of 8-OHdG formed decreases with increasing LET, and it has the highest value under X-rays. In the presence of GNPs, the G value of 8-OHdG increases significantly under X-rays. Similar trends are seen under heavy ions, except for protons. The increase of G value of 8-OHdG suggests a potential of the applicability of GNPs to particle therapies for cancer.
- 2 September 2025
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 101 (11) , 1129-1134
Open AccessChanges in yields of oxidative damages 8-hydroxy-2′-deoxyguanosine in the presence of gold nanoparticles under X-rays, protons and heavy ions
To clarify the mechanisms of GNPs radiosensitizing effects, we investigated changes in yields of 8-hydroxy-2'-deoxyguanosine (8-OHdG), which is an oxidative damage marker and generated by reactions of 2'-deoxyguanosine (dG) with OH radicals in aqueous solutions. Aqueous dG (Sigma Aldrich) solutions (500 μM) are irradiated with X-rays, protons and heavy ions in a wide LET range. The examined LET range is from about 2 to 600 eV/nm. After the irradiation, electrochemical detectors connected to HPLC system are employed to quantitatively evaluate changes in yields of 8-OHdG in the presence and in the absence of GNPs. The size of GNPs applied is a gold core diameter of between 2 and 3 nm. The G value of 8-OHdG formed decreases with increasing LET, and it has the highest value under X-rays. In the presence of GNPs, the G value of 8-OHdG increases significantly under X-rays. Similar trends are seen under heavy ions, except for protons. The increase of G value of 8-OHdG suggests a potential of the applicability of GNPs to particle therapies for cancer.
- 2 September 2025
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 101 (11) , 1098-1104
Ultra-high dose rate protons in clinical irradiation suppress DNA single-strand breaks induction in the below nano-second time scale of physicochemical stages
This study investigated the impact of ultra-high dose rate (UHDR) proton radiotherapy on DNA damage compared to conventional dose rate (CONV) radiotherapy. We hypothesized that the unique physicochemical processes associated with UHDR could lead to a reduction of DNA damage. Thus, the aim of this study is to clarify the time scale of the physicochemical processes in which the suppression of SSBs by UHDR proton irradiation occurs. Plasmid DNA (pBR322, 4.3 kbp) was irradiated in Tris-HCl solution at three concentrations: 10, 100, and 900 mM. The time-averaged dose rates were 0.1 Gy/s (CONV) and 50 Gy/s (UHDR). Following irradiation, DNA single-strand breaks (SSBs) and double-strand breaks (DSBs) were quantified using agarose gel electrophoresis. A significant reduction in SSB induction was observed only for DNA solution at the highest concentration (900 mM), which corresponds to a scavenging time of approximately 1 ns. These findings suggest that the suppression of SSB induction at UHDR is primarily due to rapid radical-radical reactions occurring within the first nano-second after irradiation. This study provides further insights into the potential benefits of UHDR radiotherapy for reducing healthy tissue damage.
- 2 September 2025
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 101 (11) , 1098-1104
Ultra-high dose rate protons in clinical irradiation suppress DNA single-strand breaks induction in the below nano-second time scale of physicochemical stages
This study investigated the impact of ultra-high dose rate (UHDR) proton radiotherapy on DNA damage compared to conventional dose rate (CONV) radiotherapy. We hypothesized that the unique physicochemical processes associated with UHDR could lead to a reduction of DNA damage. Thus, the aim of this study is to clarify the time scale of the physicochemical processes in which the suppression of SSBs by UHDR proton irradiation occurs. Plasmid DNA (pBR322, 4.3 kbp) was irradiated in Tris-HCl solution at three concentrations: 10, 100, and 900 mM. The time-averaged dose rates were 0.1 Gy/s (CONV) and 50 Gy/s (UHDR). Following irradiation, DNA single-strand breaks (SSBs) and double-strand breaks (DSBs) were quantified using agarose gel electrophoresis. A significant reduction in SSB induction was observed only for DNA solution at the highest concentration (900 mM), which corresponds to a scavenging time of approximately 1 ns. These findings suggest that the suppression of SSB induction at UHDR is primarily due to rapid radical-radical reactions occurring within the first nano-second after irradiation. This study provides further insights into the potential benefits of UHDR radiotherapy for reducing healthy tissue damage.
- 26 May 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (5) , 1-6
Importance of track density for radiolytic reactions: changes in yields of OH radical molecular probe under protons around the Bragg peak
- 26 May 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (5) , 1-6
Importance of track density for radiolytic reactions: changes in yields of OH radical molecular probe under protons around the Bragg peak
- 21 March 2025
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 27 (14) , 6887-6898
Development of a chemical code applicable to ions based on the PHITS code for efficient and visual radiolysis simulations
Water radiolysis plays an important role in elucidating radiation-induced biological effects such as early DNA damage induction, chromosome aberrations, and carcinogenesis. Several Monte Carlo simulation codes for water radiolysis, commonly referred to as chemical simulation codes, have been developed worldwide. However, these codes typically require substantial computational time to calculate the time-dependent G values of water radiolysis species (e.g., ˙OH, e− aq, H2, and H2O2), and their application is often limited to specific ion beam types. In the Particle and Heavy Ion Transport code System (PHITS), the track-structure mode that allows the simulation of each atomic interaction in liquid water for any charged particles and the subsequent chemical code (named PHITS-Chem code) dedicated to electrons was developed previously. In this study, we developed the PHITS-Chem code to support a broader range of ion beam species. To reduce computational time, we introduced new features including a space partitioning method to increase the detection efficiency of reactions between chemical species and a radical scavenger model that reduces the lifetime of OH radicals. We benchmarked the updated PHITS-Chem code by comparing its predicted time-dependent G values for protons, α particles, and carbon ions with those reported in the literature (i.e., other simulation and measured data). The inclusion of a space partitioning method and the modified OH radical scavenger model reduced the time required by the PHITS-Chem code to calculate G values (by approximately 28-fold during radiolysis simulations under 1-MeV electron exposure) while maintaining calculation accuracy. A key advantage of the PHITS-Chem code is the four-dimensional visualization capability, integrated with PHITS′ native visualization software, PHIG-3D. Considering the ability of the PHITS-Chem code to handle OH radical scavengers (i.e., tris(hydroxymethyl)aminomethane and dimethyl sulfoxide), it is anticipated to offer precise and intuitive insights into the radiation-induced biological effects of chemical species in ion-beam radiotherapy.
- 21 March 2025
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 27 (14) , 6887-6898
Development of a chemical code applicable to ions based on the PHITS code for efficient and visual radiolysis simulations
Water radiolysis plays an important role in elucidating radiation-induced biological effects such as early DNA damage induction, chromosome aberrations, and carcinogenesis. Several Monte Carlo simulation codes for water radiolysis, commonly referred to as chemical simulation codes, have been developed worldwide. However, these codes typically require substantial computational time to calculate the time-dependent G values of water radiolysis species (e.g., ˙OH, e− aq, H2, and H2O2), and their application is often limited to specific ion beam types. In the Particle and Heavy Ion Transport code System (PHITS), the track-structure mode that allows the simulation of each atomic interaction in liquid water for any charged particles and the subsequent chemical code (named PHITS-Chem code) dedicated to electrons was developed previously. In this study, we developed the PHITS-Chem code to support a broader range of ion beam species. To reduce computational time, we introduced new features including a space partitioning method to increase the detection efficiency of reactions between chemical species and a radical scavenger model that reduces the lifetime of OH radicals. We benchmarked the updated PHITS-Chem code by comparing its predicted time-dependent G values for protons, α particles, and carbon ions with those reported in the literature (i.e., other simulation and measured data). The inclusion of a space partitioning method and the modified OH radical scavenger model reduced the time required by the PHITS-Chem code to calculate G values (by approximately 28-fold during radiolysis simulations under 1-MeV electron exposure) while maintaining calculation accuracy. A key advantage of the PHITS-Chem code is the four-dimensional visualization capability, integrated with PHITS′ native visualization software, PHIG-3D. Considering the ability of the PHITS-Chem code to handle OH radical scavengers (i.e., tris(hydroxymethyl)aminomethane and dimethyl sulfoxide), it is anticipated to offer precise and intuitive insights into the radiation-induced biological effects of chemical species in ion-beam radiotherapy.
- 13 November 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (16-18) , 1681-1685
Evaluation and optimization of measurement conditions for heavy ions with fluorescent nuclear track detectors
In applying fluorescent nuclear track detectors for heavy ion measurement, the fluorescence intensity directly influences linear energy transfer (LET) estimation. However, the conventional analysis highly depends on the analyzed depth and the reference frames from the optical readout. To improve the accuracy of measurements of heavy ions, the gradient of intensity and moving average fluorescence intensity were acquired and calculated to optimize the measurement conditions. The results indicate that the intensity gradient is an alternative quantity to discriminate ions with different LET, and the moving average fluorescence intensity is readily differentiated among individual ions without overlapping values in fluorescence intensity. The scanned range of 25–45 μm is suggested to be the most suitable depth for measurement. To exclude the impact of the variation in fluorescence intensity on evaluation, it is recommended to use the quantities calculated in moving averages with depth in the future.
- 13 November 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (16-18) , 1681-1685
Evaluation and optimization of measurement conditions for heavy ions with fluorescent nuclear track detectors
In applying fluorescent nuclear track detectors for heavy ion measurement, the fluorescence intensity directly influences linear energy transfer (LET) estimation. However, the conventional analysis highly depends on the analyzed depth and the reference frames from the optical readout. To improve the accuracy of measurements of heavy ions, the gradient of intensity and moving average fluorescence intensity were acquired and calculated to optimize the measurement conditions. The results indicate that the intensity gradient is an alternative quantity to discriminate ions with different LET, and the moving average fluorescence intensity is readily differentiated among individual ions without overlapping values in fluorescence intensity. The scanned range of 25–45 μm is suggested to be the most suitable depth for measurement. To exclude the impact of the variation in fluorescence intensity on evaluation, it is recommended to use the quantities calculated in moving averages with depth in the future.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
3D track extraction from a fluorescent nuclear track detector via machine learning and an application to diagnostics of laser-driven ions
We have developed an ion diagnostic method for laser-driven ion acceleration experiments that uses fluorescent nuclear track detectors (FNTDs). An FNTD records the particle tracks as color centers and does not require chemical etching, unlike CR-39 track detectors. The color centers are observed using a confocal laser microscope, and 3D particle tracks can be obtained by changing its focal position. The intensity of the color centers corresponds to the energy deposited by the ions. The nuclides of the ions can be determined from the intensity distribution of the color centers as a function of depth and the distance between the stopping point and the surface of the detector. To extract the intensity distribution, we must track the same ion tracks in the depth-layered microscopic images from the surface to the stopping point, even if they overlap with those of other ions. In addition, since an FNTD is sensitive not only to ions but also to electrons and photons, we must identify ion tracks among those from the latter particles. To analyze a statistical number of ion tracks, it is necessary to automate these processes. We have thus developed a method for automated ion detection and 3D tracking that relies on a support vector classifier and a kernelized correlation filter. This method was tested on a laser ion acceleration experiment performed using the J-KAREN-P laser. The method automatically detects ion tracks on FNTDs and tracks them in the depth direction. The training data are sampled from the Heavy-Ion Medical Accelerator in Chiba.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
3D track extraction from a fluorescent nuclear track detector via machine learning and an application to diagnostics of laser-driven ions
We have developed an ion diagnostic method for laser-driven ion acceleration experiments that uses fluorescent nuclear track detectors (FNTDs). An FNTD records the particle tracks as color centers and does not require chemical etching, unlike CR-39 track detectors. The color centers are observed using a confocal laser microscope, and 3D particle tracks can be obtained by changing its focal position. The intensity of the color centers corresponds to the energy deposited by the ions. The nuclides of the ions can be determined from the intensity distribution of the color centers as a function of depth and the distance between the stopping point and the surface of the detector. To extract the intensity distribution, we must track the same ion tracks in the depth-layered microscopic images from the surface to the stopping point, even if they overlap with those of other ions. In addition, since an FNTD is sensitive not only to ions but also to electrons and photons, we must identify ion tracks among those from the latter particles. To analyze a statistical number of ion tracks, it is necessary to automate these processes. We have thus developed a method for automated ion detection and 3D tracking that relies on a support vector classifier and a kernelized correlation filter. This method was tested on a laser ion acceleration experiment performed using the J-KAREN-P laser. The method automatically detects ion tracks on FNTDs and tracks them in the depth direction. The training data are sampled from the Heavy-Ion Medical Accelerator in Chiba.