Kyle D. Rauch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kyle D. Rauch has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Graham A. Gagnon
Centre for Water Resources Studies, Department of Civil & Resource Engineering, Dalhousie University, 1360 Barrington Street, Halifax, Nova Scotia B3H 4R2, Canada
6 shared publications - Amina K. Stoddart
Centre for Water Resources Studies, Department of Civil & Resource Engineering, Dalhousie University, 1360 Barrington Street, Halifax, Nova Scotia B3H 4R2, Canada
5 shared publications - Sean A. MacIsaac
Dalhousie University
4 shared publications - Allison L. Mackie
Centre for Water Resources Studies, Faculty of Civil and Resource Engineering, Dalhousie University, Halifax, Canada
1 shared publication Amina K. Stoddart
Department of Civil & Resource Engineering, Dalhousie University, Halifax, NS, Canada
1 shared publicationAnthony L Pimentel
Water Technology Group, Black & Veatch, 550 Hope St Suite 2250, Los Angeles 90071, CA, USA
1 shared publication
Latest Publications
- Open Access
- 1 November 2025
- Published by Wiley in AWWA Water Science
- Vol. 7 (6)
Combined UV LED and Chlorine for Synergistic Drinking Water Disinfection and Assessment of Disinfection By‐Product Formation
This study provides a comprehensive evaluation of the effectiveness of 280 nm UV LEDs in enhancing chlorine disinfection in natural water sources. The results of this work indicate sequential treatments (UV‐chlorine and chlorine‐UV) further enhanced the disinfection efficiency of T1 in natural waters, especially at higher UV doses, such as 40 mJ cm −2 . The log reduction value for the chlorine‐UV sequence reached 6.65, slightly higher than the 6.29 for the UV‐chlorine sequence, suggesting that sequencing influences disinfection efficacy at higher fluences. UV LED‐enhanced chlorine disinfection did not significantly alter concentrations of THMs and HAAs. Overall, the findings of this study open new avenues for the application of UV LEDs in drinking water disinfection, demonstrating their potential as an alternative to traditional disinfection methods. Future research should further explore the effects of UV‐chlorine combined treatments under different water quality conditions to optimize disinfection processes and provide theoretical support for innovation in water treatment technologies.
- 1 November 2025
- Published by Wiley in AWWA Water Science
- Vol. 7 (6)
Open AccessCombined UV LED and Chlorine for Synergistic Drinking Water Disinfection and Assessment of Disinfection By‐Product Formation
This study provides a comprehensive evaluation of the effectiveness of 280 nm UV LEDs in enhancing chlorine disinfection in natural water sources. The results of this work indicate sequential treatments (UV‐chlorine and chlorine‐UV) further enhanced the disinfection efficiency of T1 in natural waters, especially at higher UV doses, such as 40 mJ cm −2 . The log reduction value for the chlorine‐UV sequence reached 6.65, slightly higher than the 6.29 for the UV‐chlorine sequence, suggesting that sequencing influences disinfection efficacy at higher fluences. UV LED‐enhanced chlorine disinfection did not significantly alter concentrations of THMs and HAAs. Overall, the findings of this study open new avenues for the application of UV LEDs in drinking water disinfection, demonstrating their potential as an alternative to traditional disinfection methods. Future research should further explore the effects of UV‐chlorine combined treatments under different water quality conditions to optimize disinfection processes and provide theoretical support for innovation in water treatment technologies.
- Open Access
- 18 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
UV LED disinfection as a novel treatment for common salmonid pathogens
Aeromonas salmonicida and Yersinia ruckeri are common pathogenic bacteria that impact salmonid aquaculture. Although vaccinations are available against both organisms, large-scale vaccination efforts can be expensive, cumbersome, and are not always reliable. Alternatively, these pathogens have been effectively inactivated using UV radiation from mercury-based systems. These systems are energy intensive and fragile which currently limits their use to closed and semi-closed production systems. UV light emitting diodes (UV LEDs) have recently emerged as a novel alternative to traditional mercury-based treatment. UV LEDs have durable housing, a relatively low energy draw, can be powered by a battery source and are adaptable to challenging environments. This study examined the effectiveness of three UV LED wavelengths for disinfection of A. salmonicida and Y. ruckeri in pure culture and resuspended in a wastewater matrix. All tested UV LEDs were effective in disinfecting both organisms. 267 and 279 nm wavelengths outperformed 255 nm disinfection in both test matrices. Particulate matter from wastewater reduced the upper limit of treatment for A. salmonicida but results still indicated that all wavelengths were effective for disinfection in a challenging matrix. This study represents the first use of UV LEDs for disinfection of A. salmonicida and Y. ruckeri and provides impact to aquaculture producers looking to implement novel technologies for disease control.
- 18 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Open AccessUV LED disinfection as a novel treatment for common salmonid pathogens
Aeromonas salmonicida and Yersinia ruckeri are common pathogenic bacteria that impact salmonid aquaculture. Although vaccinations are available against both organisms, large-scale vaccination efforts can be expensive, cumbersome, and are not always reliable. Alternatively, these pathogens have been effectively inactivated using UV radiation from mercury-based systems. These systems are energy intensive and fragile which currently limits their use to closed and semi-closed production systems. UV light emitting diodes (UV LEDs) have recently emerged as a novel alternative to traditional mercury-based treatment. UV LEDs have durable housing, a relatively low energy draw, can be powered by a battery source and are adaptable to challenging environments. This study examined the effectiveness of three UV LED wavelengths for disinfection of A. salmonicida and Y. ruckeri in pure culture and resuspended in a wastewater matrix. All tested UV LEDs were effective in disinfecting both organisms. 267 and 279 nm wavelengths outperformed 255 nm disinfection in both test matrices. Particulate matter from wastewater reduced the upper limit of treatment for A. salmonicida but results still indicated that all wavelengths were effective for disinfection in a challenging matrix. This study represents the first use of UV LEDs for disinfection of A. salmonicida and Y. ruckeri and provides impact to aquaculture producers looking to implement novel technologies for disease control.
- Open Access
- 30 October 2024
- Published by Elsevier in Water Research X
- Vol. 25, 100271
A critical review of ultra-violet light emitting diodes as a one water disinfection technology
- 30 October 2024
- Published by Elsevier in Water Research X
- Vol. 25, 100271
Open AccessA critical review of ultra-violet light emitting diodes as a one water disinfection technology
- Open Access
- 1 November 2023
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 3 (11) , 3667-3675
Comparison of Legionella pneumophila and Pseudomonas fluorescens Quantification Methods for Assessing UV LED Disinfection
This study assesses the efficacy of ultraviolet light-emitting diodes (UV LEDs) for deactivating Legionella pneumophila (pure culture) and Pseudomonas fluorescens (pure culture and biofilms) on relevant drinking water distribution system surfaces (cast iron and stainless steel). UV LED treatment at 280 nm demonstrated superior performance compared to that at 365 nm, achieving a 4.8 log reduction value (LRV) for P. fluorescens pure cultures and, for biofilms, 4.02 LRV for stainless steel and 2.96 LRV for cast iron at 280 nm. Conversely, the results were less effective at 365 nm, with suspected photolytic reactions on cast iron. Quantification of L. pneumophila yielded varying results: 4 LRV using standard plate counts, 1.8 LRV with Legiolert, and 1 LRV with quantitative polymerase chain reaction at 280 nm, while the results were less than 1.5 LRV at 365 nm. This study provides insights into managing opportunistic pathogens and biofilms, emphasizing the need for improved quantification tools to better assess treatment efficacy.
- 1 November 2023
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 3 (11) , 3667-3675
Open AccessComparison of Legionella pneumophila and Pseudomonas fluorescens Quantification Methods for Assessing UV LED Disinfection
This study assesses the efficacy of ultraviolet light-emitting diodes (UV LEDs) for deactivating Legionella pneumophila (pure culture) and Pseudomonas fluorescens (pure culture and biofilms) on relevant drinking water distribution system surfaces (cast iron and stainless steel). UV LED treatment at 280 nm demonstrated superior performance compared to that at 365 nm, achieving a 4.8 log reduction value (LRV) for P. fluorescens pure cultures and, for biofilms, 4.02 LRV for stainless steel and 2.96 LRV for cast iron at 280 nm. Conversely, the results were less effective at 365 nm, with suspected photolytic reactions on cast iron. Quantification of L. pneumophila yielded varying results: 4 LRV using standard plate counts, 1.8 LRV with Legiolert, and 1 LRV with quantitative polymerase chain reaction at 280 nm, while the results were less than 1.5 LRV at 365 nm. This study provides insights into managing opportunistic pathogens and biofilms, emphasizing the need for improved quantification tools to better assess treatment efficacy.
- Open Access
- 10 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Improved disinfection performance for 280 nm LEDs over 254 nm low-pressure UV lamps in community wastewater
Ultraviolet (UV) disinfection has been incorporated into both drinking water and wastewater treatment processes for several decades; however, it comes with negative environmental consequences such as high energy demands and the use of mercury. Understanding how to scale and build climate responsive technologies is key in fulfilling the intersection of UN Sustainable Development Goals 6 and 13. One technology that addresses the drawbacks of conventional wastewater UV disinfection systems, while providing a climate responsive solution, is UV light emitting diodes (LEDs). The objective of this study was to compare performance of bench-scale 280 nm UV LEDs to bench-scale low pressure (LP) lamps and full-scale UV treated wastewater samples. Results from the study demonstrated that the UV LED system provides a robust treatment that outperformed LP systems at the bench-scale. A comparison of relative energy consumptions of the UV LED system at 20 mJ cm−2 and LP system at 30 and 40 mJ cm−2 was completed. Based on current projections for wall plug efficiencies (WPE) of UV LED it is expected that the energy consumption of LED reactors will be on par or lower compared to the LP systems by 2025. This study determined that, at a WPE of 20%, the equivalent UV LED system would lead to a 24.6% and 43.4% reduction in power consumption for the 30 and 40 mJ cm−2 scenarios, respectively.
- 10 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Open AccessImproved disinfection performance for 280 nm LEDs over 254 nm low-pressure UV lamps in community wastewater
Ultraviolet (UV) disinfection has been incorporated into both drinking water and wastewater treatment processes for several decades; however, it comes with negative environmental consequences such as high energy demands and the use of mercury. Understanding how to scale and build climate responsive technologies is key in fulfilling the intersection of UN Sustainable Development Goals 6 and 13. One technology that addresses the drawbacks of conventional wastewater UV disinfection systems, while providing a climate responsive solution, is UV light emitting diodes (LEDs). The objective of this study was to compare performance of bench-scale 280 nm UV LEDs to bench-scale low pressure (LP) lamps and full-scale UV treated wastewater samples. Results from the study demonstrated that the UV LED system provides a robust treatment that outperformed LP systems at the bench-scale. A comparison of relative energy consumptions of the UV LED system at 20 mJ cm−2 and LP system at 30 and 40 mJ cm−2 was completed. Based on current projections for wall plug efficiencies (WPE) of UV LED it is expected that the energy consumption of LED reactors will be on par or lower compared to the LP systems by 2025. This study determined that, at a WPE of 20%, the equivalent UV LED system would lead to a 24.6% and 43.4% reduction in power consumption for the 30 and 40 mJ cm−2 scenarios, respectively.
- 1 March 2019
- Published by Elsevier in Water Research
- Vol. 151, 193-202
Inactivation of biofilm-bound Pseudomonas aeruginosa bacteria using UVC light emitting diodes (UVC LEDs)
- 1 March 2019
- Published by Elsevier in Water Research
- Vol. 151, 193-202
Inactivation of biofilm-bound Pseudomonas aeruginosa bacteria using UVC light emitting diodes (UVC LEDs)
- 7 September 2018
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 41 (2) , 146-155
Biomass Recovery Method for Adenosine Triphosphate (ATP) Quantification Following UV Disinfection
A biomass recovery method was developed to monitor UV disinfection efficacy using adenosine triphosphate (ATP). Typically, disinfection monitoring at wastewater treatment facilities (WWTFs) involves quantifying fecal and total coliforms or colony forming units, the results of which take a minimum of 24 h to produce. ATP quantification immediately before and after UV treatment, which takes only minutes, shows little reduction and often an increase in the microbial population since UV irradiation results in cells that are viable (i.e., still producing ATP) but not culturable. To overcome this, our biomass recovery method incorporates an incubation step to encourage life cycling of microbes. Average log reductions in cellular ATP (cATP) were found to be −0.28 ± 0.19, −0.011 ± 0.153, −0.17 ± 0.32, and 0.065 ± 0.074 using direct ATP measurements on UV-treated samples from WWTFs A, B, C, and D, respectively, while those using the recovery method were correspondingly 0.17 ± 0.34, 1.8 ± 0.8, 0.20 ± 0.35, and 0.72 ± 0.26. The response of the biomass recovery-ATP method indicated a significant direct correlation to the microbial population reduction observed in heterotrophic plate count (HPC) and Colilert® methods using both pure Escherichia coli culture and secondary municipal wastewater effluent.
- 7 September 2018
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 41 (2) , 146-155
Biomass Recovery Method for Adenosine Triphosphate (ATP) Quantification Following UV Disinfection
A biomass recovery method was developed to monitor UV disinfection efficacy using adenosine triphosphate (ATP). Typically, disinfection monitoring at wastewater treatment facilities (WWTFs) involves quantifying fecal and total coliforms or colony forming units, the results of which take a minimum of 24 h to produce. ATP quantification immediately before and after UV treatment, which takes only minutes, shows little reduction and often an increase in the microbial population since UV irradiation results in cells that are viable (i.e., still producing ATP) but not culturable. To overcome this, our biomass recovery method incorporates an incubation step to encourage life cycling of microbes. Average log reductions in cellular ATP (cATP) were found to be −0.28 ± 0.19, −0.011 ± 0.153, −0.17 ± 0.32, and 0.065 ± 0.074 using direct ATP measurements on UV-treated samples from WWTFs A, B, C, and D, respectively, while those using the recovery method were correspondingly 0.17 ± 0.34, 1.8 ± 0.8, 0.20 ± 0.35, and 0.72 ± 0.26. The response of the biomass recovery-ATP method indicated a significant direct correlation to the microbial population reduction observed in heterotrophic plate count (HPC) and Colilert® methods using both pure Escherichia coli culture and secondary municipal wastewater effluent.