PFPavel Frajtag

Pavel Frajtag

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pavel Frajtag has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    HIGHLY LOCALIZED AZIMUTHAL MEASUREMENTS IN THE CROCUS REACTOR TOWARDS THE VALIDATION OF HIGH-FIDELITY NEUTRONICS CODES

    by Fanny Vitullo, Vincent Lamirand, Pavel Frajtag, Gregory Perret, Andreas Pautz

    Highly localized in-core measurements are necessary for the validation of neutron transport calculations with high spatial resolution. In the present work, a miniature neutron detector developed at EPFL in collaboration with PSI was used to carry out a set of thermal neutrons counting measurements in the zero-power CROCUS reactor core within a spatial range in order of mm. The miniature detector, positioned close to the core reflector, shows a gradient of +(4.29 ± 0.10)% in the count rate profile in the radial direction within 1.3 cm, with higher values pointing towards the core reflector because of the higher share of neutrons in the thermal range. On the contrary, in a control rod guide tube the count rate gradient is -(4.37 ± 0.10)% and it is directed towards the core center. The measured values are compared with the azimuthal trend of the normalized 6Li reaction rate calculated with an iterative three-steps method performed with the Monte Carlo code Serpent 2. These measurements proved the feasibility of resolving spatial effects in the mm-range and they represent a basis for further investigating highly spatially-resolved phenomena in the CROCUS core.


  • Open Access

    Kilogram‐Scale Crystallogenesis of Halide Perovskites for Gamma‐Rays Dose Rate Measurements

    by Pavao Andričević, Pavel Frajtag, Vincent Pierre Lamirand, Andreas Pautz, Márton Kollár, Bálint Náfrádi, Andrzej Sienkiewicz, Tonko Garma, László Forró, Endre Horváth

    Gamma‐rays (γ‐rays), wherever present, e.g., in medicine, nuclear environment, or homeland security, due to their strong impact on biological matter, should be closely monitored. There is a need for simple, sensitive γ‐ray detectors at affordable prices. Here, it is shown that γ‐ray detectors based on crystals of methylammonium lead tribromide (MAPbBr3) ideally meet these requirements. Specifically, the γ‐rays incident on a MAPbBr3 crystal generates photocarriers with a high mobility‐lifetime product, allowing radiation detection by photocurrent measurements at room temperatures. Moreover, the MAPbBr3 crystal‐based detectors, equipped with improved carbon electrodes, can operate at low bias (≈1.0 V), hence being suitable for applications in energy‐sparse environments, including space. The γ‐ray detectors reported herein are exposed to radiation from a 60Co source at dose rates up to 2.3 Gy h−1 under ambient conditions for over 100 h, without any sign of degradation. The excellent radiation tolerance stems from the intrinsic structural plasticity of the organic–inorganic halide perovskites, which can be attributed to a defect‐healing process by fast ion migration at the nanoscale level. The sensitivity of the γ‐ray detection upon volume is tested for MAPbBr3 crystals reaching up to 1000 cm3 (3.3 kg in weight) grown by a unique crystal growth technique.


  • Design of Separated Element Reflector Experiments in CROCUS: PETALE

    by Vincent Lamirand, Gregory Perret, Stefan Radman, Daniel Siefman, Pavel Frajtag, Mathieu Hursin, Adrien Gruel, Pierre Leconte, Patrick Blaise, Andreas Pautz

    The present article describes the preliminary design studies for PETALE (Programme d’Etude en Transmission de l’Acier Lourd et ses Eléments), an oncoming experimental program in the CROCUS reactor. Within the framework of the Venus-Eole-Proteus collaboration, PETALE continues the nuclear data validation efforts required for modeling GEN-III pressurized water reactors with heavy steel reflectors. The inelastic scattering cross sections at around 1 MeV of iron-56, as well as nickel and chromium isotopes, will be studied separately. The water reflector will be replaced successively by sheets of stainless steel alloy and pure metals—iron, nickel, and chromium. Data will be extracted from two sources: the measured neutron flux attenuation using adequate dosimetry and possibly fission chambers in the metal reflector and from the criticality effects of these reflectors. PETALE will also be used with nuclear data adjustment methods because, as a separated and elemental integral experiment, it allows the limiting of compensation effects in the nuclear data adjustments. A parametric study has been carried out with MCNPX for assessing the optimal configuration and the feasibility of the experiments. This study is the first step toward optimizing the global sensitivity of the experiments to the reactions in the energy range of interest, thus assessing the measurements’ target uncertainties and preparing further use of the program results.


  • Kinetic Parameter Measurements in the CROCUS Reactor Using Current Mode Instrumentation

    by O. Pakari, V. Lamirand, G. Perret, P. Frajtag, A. Pautz

    The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff/Λ, the effective delayed neutron fraction βeff, and the mean generation time Λ for nuclear databases and code validation efforts. A newly developed current mode detection system using two fission chambers in the core reflector was used to accurately measure the kinetic parameters of CROCUS. Characteristics of the system and the performed noise measurements are presented. We implemented noise postprocessing of the current signals acquired at 900 mW using the APSD/CPSD method. The final CPSD estimated values were found to be α = (153.3 ± 8.6) s-1, βeff = (778 ± 14) pcm, and Λ = (50.7 ± 2.9) μs. In order to comply with experimental uncertainty targets (<3%), the measurement time was 6 hours. In comparison to code predictions using MCNP5-v1.6 employing the JEFF 3.1 and ENDF/B-7.1 cross section libraries, we found differences up to 3%, confirming the need for accurate kinetic parameter measurements. In the future the new measurement system will also be used for studies of spatial and external reactor noise.


  • Open Access

    Current Mode Neutron Noise Measurements in the Zero Power Reactor CROCUS

    by O. Pakari, V. Lamirand, G. Perret, L. Braun, P. Frajtag, A. Pautz

    The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff / λ, the effective delayed neutron fraction βeff, and the mean generation time λ for code validation efforts. At higher detection rates, i.e. above 2×104 cps in the used configuration at 0.1 W, the previously employed pulse charge amplification electronics with BF3 detectors yielded erroneous results due to dead time effects. Future experimental needs call for higher sensitivity in detectors, higher detection rates or higher reactor powers, and thus a generally more versatile measurement system. We, therefore, explored detectors operated with current mode acquisition electronics to accommodate the need. We approached the matter in two ways: 1) By using the two compensated 10B-coated ionization chambers available in CROCUS as operational monitors. The compensated current signal of these chambers was extracted from coremonitoring output channels. 2) By developing a new current mode amplification station to be used with other available detectors in core. Characteristics and first noise measurements of the new current system are presented. We implemented post-processing of the current signals from 1)and 2) with the APSD/CPSD method to determine α. At two critical states (0.5 and 1.5 W), using the 10B ionization chambers and their CPSD estimate, the prompt decay constant was measured after 1.5 hours to be α=(156.9 ± 4.3) s-1 (1σ). This result is within 1σ of statistical uncertainties of previous experiments and MCNPv5-1.6 predictions using the ENDF/B-7.1 library. The newsystem connected to a CFUL01 fission chamber using the APSDestimate at 100 mW after 33 min yielded α = (160.8 ± 6.3) s-1, also within 1σ agreement. The improvements to previous neutron noise measurementsinclude shorter measurement durations that can achievecomparable statistical uncertainties and measurements at higherdetection rates.


  • Comparative study of LEDs conformally overgrown on multi-facet GaN NWs vs. conventional c-plane LEDs

    by A.M. Hosalli, P. Frajtag, D. M. Van Den Broeck, T. Paskova, N.A. El-Masry, S.M. Bedair

    Over the last decade, considerable efforts have gone into researching techniques to improve the efficiency of light emitting diodes (LEDs) based on the III-nitride material system. These efforts can be classified into two main approaches : improving the internal quantum efficiency (IQE) and increasing the light extraction efficiency of the LED devices. In the work outlined below, we demonstrate a unique LED structure that has a significantly enhanced light output intensity compared to c-plane LEDs by tackling both approaches simultaneously. We investigated the ratio of light output intensity of the NWs LED vs the c-plane LED as a function of current density. At lower current densities, the lower QCSE in NWs LED is responsible for a large ratio. This reduces with increasing current density as carrier screening of the polarization field in the c-plane LED negates the QCSE effect. The ratio saturates at higher current densities where the mechanism for higher light output is dominated by the light extraction efficiency that depends only on the device geometry and is independent of the current density in the NWs LED.

  • Open Access

    Growing thin films that contain embedded voids

    by Pavel Frajtag, Nadia El-Masry, Salah Bedair, Aadhithya Hosalli, Geoffrey Bradshaw

    Uniform voiding defects in thin films offer unique designs for brighter and more efficient LEDs.


  • Embedded voids formation by overgrowth on GaN nanowires for high-quality GaN films

    by P. Frajtag, J.P. Samberg, N.A. El-Masry, N. Nepal, S.M. Bedair


  • Embedded voids approach for low defect density in epitaxial GaN films

    by P. Frajtag, N. A. El-Masry, N. Nepal, S. M. Bedair

    We have developed a technique for defect reduction in GaN epitaxial films grown on sapphire substrates. This technique relies on the generation of high densities of embedded microvoids (∼108/cm2), a few microns long and less than a micron in diameter. These voids are located near the sapphire substrate, where high densities of dislocations are present. Network of embedded voids offer free surfaces that act as dislocation sinks or termination sites for the dislocations generated at the GaN/sapphire interface. Both transmission electron and atomic force microscopy results confirm the uniform reduction of the dislocation density by two orders of magnitude.