ZWZeev Waks

Zeev Waks

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zeev Waks has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterizing patient compliance over six months in remote digital trials of Parkinson’s and Huntington disease

    by Shani Cohen, Zeev Waks, Jordan J. Elm, Mark Forrest Gordon, Igor D. Grachev, Leehee Navon-Perry, Shai Fine, Iris Grossman, Spyros Papapetropoulos, Juha-Matti Savola

    A growing number of clinical trials use various sensors and smartphone applications to collect data outside of the clinic or hospital, raising the question to what extent patients comply with the unique requirements of remote study protocols. Compliance is particularly important in conditions where patients are motorically and cognitively impaired. Here, we sought to understand patient compliance in digital trials of two such pathologies, Parkinson’s disease (PD) and Huntington disease (HD). Patient compliance was assessed in two remote, six-month clinical trials of PD (n = 51, Clinician Input Study funded by the Michael J. Fox Foundation for Parkinson’s Research) and HD (n = 17, sponsored by Teva Pharmaceuticals). We monitored four compliance metrics specific to remote studies: smartphone app-based medication reporting, app-based symptoms reporting, the duration of smartwatch data streaming except while charging, and the performance of structured motor tasks at home. While compliance over time differed between the PD and HD studies, both studies maintained high compliance levels for their entire six month duration. None (− 1%) to a 30% reduction in compliance rate was registered for HD patients, and a reduction of 34 to 53% was registered for the PD study. Both studies exhibited marked changes in compliance rates during the initial days of enrollment. Interestingly, daily smartwatch data streaming patterns were similar, peaking around noon, dropping sharply in the late evening hours around 8 pm, and having a mean of 8.6 daily streaming hours for the PD study and 10.5 h for the HD study. Individual patients tended to have either high or low compliance across all compliance metrics as measured by pairwise correlation. Encouragingly, predefined schedules and app-based reminders fulfilled their intended effect on the timing of medication intake reporting and performance of structured motor tasks at home. Our findings suggest that maintaining compliance over long durations is feasible, promote the use of predefined app-based reminders, and highlight the importance of patient selection as highly compliant patients typically have a higher adherence rate across the different aspects of the protocol. Overall, these data can serve as a reference point for the design of upcoming remote digital studies. Trials described in this study include a sub-study of the Open PRIDE-HD Huntington’s disease study (TV7820-CNS-20016), which was registered on July 7th, 2015, sponsored by Teva Pharmaceuticals Ltd., and registered on Clinicaltrials.gov as NCT02494778 and EudraCT as 2015–000904-24 .


  • Open Access

    Wrist Sensor Fusion Enables Robust Gait Quantification Across Walking Scenarios

    by Zeev Waks, Itzik Mazeh, Chen Admati, Michal Afek, Yonatan Dolan, Avishai Wagner

    Quantifying step abundance via single wrist-worn accelerometers is a common approach for encouraging active lifestyle and tracking disease status. Nonetheless, step counting accuracy can be hampered by fluctuations in walking pace or demeanor. Here, we assess whether the use of various sensor fusion techniques, each combining bilateral wrist accelerometer data, may increase step count robustness. By collecting data from 27 healthy subjects, we find that high-level step fusion leads to substantially improved accuracy across diverse walking scenarios. Gait cycle analysis illustrates that wrist devices can recurrently detect steps proximal to toe-off events. Collectively, our study suggests that dual-wrist sensor fusion may enable robust gait quantification in free-living environments.

  • Open Access

    Evicase: An Evidence-based Case Structuring Approach for Personalized Healthcare

    by Carmeli Boaz, Casali Paolo, Goldbraich Anna, Goldsteen Abigail, Kent Carmel, Licitra Lisa, Locatelli Paolo, Restifo Nicola, Rinott Ruty, Sini Elena, et al.

    The personalized medicine era stresses a growing need to combine evidence-based medicine with case based reasoning in order to improve the care process. To address this need we suggest a framework to generate multi-tiered statistical structures we call Evicases. Evicase integrates established medical evidence together with patient cases from the bedside. It then uses machine learning algorithms to produce statistical results and aggregators, weighted predictions, and appropriate recommendations. Designed as a stand-alone structure, Evicase can be used for a range of decision support applications including guideline adherence monitoring and personalized prognostic predictions.


  • Open Access

    Visualization of single mRNAs reveals temporal association of proteins with microRNA-regulated mRNA

    by Joseph D. Shih, Zeev Waks, Nancy Kedersha, Pamela A. Silver

    Although many proteins are known to function in microRNA (miRNA)-based translational repression, we lack a comprehensive understanding of temporal relationships between the mRNA, miRNA and their constituent proteins. To understand the dynamics of miRNA and protein interactions, we created a synthetic inducible miRNA system in mammalian cells. By visualizing single mRNAs and observing their co-localization with proteins over time, we produced a temporal association map of miRNA-associated factors. Argonaute2, Dcp1a, hedls and Rck co-localize with miRNA-regulated mRNA after 24 h of miRNA induction, and RNAi knockdown of any one of these proteins affected the co-localization of any of the other proteins with miRNA-regulated mRNA, demonstrating that these proteins could interact with each other in a complex. We identified Argonaute2 and hedls as proteins that co-localize and interact with miRNA-regulated mRNA, indicating that processing body components are involved in long-term storage of miRNA-regulated mRNA.