Sandra F. Lam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sandra F. Lam has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Steven Carl George
Department of Biomedical Engineering, University of California, Davis, Davis, USA
2 shared publications - Venktesh S. Shirure
Department of Biomedical Engineering, University of California, Davis, Davis, USA
2 shared publications - Alan G Soetikno
Feinberg School of Medicine, Northwestern University, Chicago, US
1 shared publication Bhupinder Shergill
Department of Biomedical Engineering, University of California Davis, USA
1 shared publication- Natalie Ng
Department of Biomedical Engineering, Washington University in St. Louis, USA
1 shared publication Yunli E. Chu
Department of Biomedical Engineering, Washington University in St. Louis, USA
1 shared publication
Latest Publications
- 17 July 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (16) , 3036-3050
Quantitative design strategies for fine control of oxygen in microfluidic systems
We provide a generalized framework for creating fine control of O 2 tension in a microfluidic system and our data emphasize the need to consider mild spatiotemporal changes in O 2 as potentially important factors in disease processes such as cancer.
- 17 July 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (16) , 3036-3050
Quantitative design strategies for fine control of oxygen in microfluidic systems
We provide a generalized framework for creating fine control of O 2 tension in a microfluidic system and our data emphasize the need to consider mild spatiotemporal changes in O 2 as potentially important factors in disease processes such as cancer.
- Open Access
- 20 December 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (12) , e0209574
Microfluidic device to attain high spatial and temporal control of oxygen
Microfluidic devices have been successfully used to recreate in vitro biological microenvironments, including disease states. However, one constant issue for replicating microenvironments is that atmospheric oxygen concentration (21% O2) does not mimic physiological values (often around 5% O2). We have created a microfluidic device that can control both the spatial and temporal variations in oxygen tensions that are characteristic of in vivo biology. Additionally, since the microcirculation is responsive to hypoxia, we used a 3D sprouting angiogenesis assay to confirm the biological relevance of the microfluidic platform. Our device consists of three parallel connected tissue chambers and an oxygen scavenger channel placed adjacent to these tissue chambers. Experimentally measured oxygen maps were constructed using phosphorescent lifetime imaging microscopy and compared with values from a computational model. The central chamber was loaded with endothelial and fibroblast cells to form a 3D vascular network. Four to six days later, fibroblasts were loaded into the side chambers, and a day later the oxygen scavenger (sodium sulfite) was flowed through the adjacent channel to induce a spatial and temporal oxygen gradient. Our results demonstrate that both constant chronic and intermittent hypoxia can bias vessel growth, with constant chronic hypoxia showing higher degrees of biased angiogenesis. Our simple design provides consistent control of spatial and temporal oxygen gradients in the tissue microenvironment and can be used to investigate important oxygen-dependent biological processes in conditions such as cancer and ischemic heart disease.
- 20 December 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (12) , e0209574
Open AccessMicrofluidic device to attain high spatial and temporal control of oxygen
Microfluidic devices have been successfully used to recreate in vitro biological microenvironments, including disease states. However, one constant issue for replicating microenvironments is that atmospheric oxygen concentration (21% O2) does not mimic physiological values (often around 5% O2). We have created a microfluidic device that can control both the spatial and temporal variations in oxygen tensions that are characteristic of in vivo biology. Additionally, since the microcirculation is responsive to hypoxia, we used a 3D sprouting angiogenesis assay to confirm the biological relevance of the microfluidic platform. Our device consists of three parallel connected tissue chambers and an oxygen scavenger channel placed adjacent to these tissue chambers. Experimentally measured oxygen maps were constructed using phosphorescent lifetime imaging microscopy and compared with values from a computational model. The central chamber was loaded with endothelial and fibroblast cells to form a 3D vascular network. Four to six days later, fibroblasts were loaded into the side chambers, and a day later the oxygen scavenger (sodium sulfite) was flowed through the adjacent channel to induce a spatial and temporal oxygen gradient. Our results demonstrate that both constant chronic and intermittent hypoxia can bias vessel growth, with constant chronic hypoxia showing higher degrees of biased angiogenesis. Our simple design provides consistent control of spatial and temporal oxygen gradients in the tissue microenvironment and can be used to investigate important oxygen-dependent biological processes in conditions such as cancer and ischemic heart disease.