Latest Publications
- Open Access
- 10 September 2026
- Published by Elsevier in Building and Environment
- Vol. 305
Ten questions concerning air movement as a primary cooling strategy: “Fan-first” cooling
- 10 September 2026
- Published by Elsevier in Building and Environment
- Vol. 305
Open AccessTen questions concerning air movement as a primary cooling strategy: “Fan-first” cooling
- 30 April 2026
- Published by Elsevier in Building and Environment
- Vol. 299
Experimental study on airflow containment and pollutant capture of a push-pull ventilation system in residential kitchens
- 30 April 2026
- Published by Elsevier in Building and Environment
- Vol. 299
Experimental study on airflow containment and pollutant capture of a push-pull ventilation system in residential kitchens
- Open Access
- 2 March 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 350
Analysis of time- and size-resolved fluorescent biological aerosol particles in a subway station
- 2 March 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 350
Open AccessAnalysis of time- and size-resolved fluorescent biological aerosol particles in a subway station
- Open Access
- 31 July 2024
- Published by Elsevier in Building and Environment
- Vol. 264
A case-control study of behavioural and built environment determinants of COVID-19 transmission in sheltered markets
- 31 July 2024
- Published by Elsevier in Building and Environment
- Vol. 264
Open AccessA case-control study of behavioural and built environment determinants of COVID-19 transmission in sheltered markets
- Open Access
A Review of In-Flight Thermal Comfort and Air Quality Status in Civil Aircraft Cabin Environments
The civil aircraft cabin is enclosed and highly occupied, making it susceptible to a decline in indoor environmental quality. The environmental quality of civil aircraft cabins not only depends on objective factors such as temperature, relative humidity, and the presence of air pollutants such as carbon dioxide (CO2), carbon monoxide (CO), ozone (O3), particle matter (PM), and volatile organic compounds (VOCs) but also the subjective factors pertaining to the perceptions and health symptoms of passengers and crew. However, few studies have thoroughly examined the air quality and thermal comfort parameters that are measured during in-flight testing in airplane cabins, as well as the passengers’ subjective perceptions. In order to evaluate the in-flight thermal comfort and air quality status, this study conducted a review of the recent literature to compile data on primary categories, standard limits, and distribution ranges of in-flight environmental factors within civil aircraft cabins. Following a search procedure outlined in this paper, 54 papers were selected for inclusion. Utilizing the Monte Carlo method, the Predicted Mean Vote (PMV) distributions under different exercise intensities and clothing thermal resistance were measured with the in-cabin temperature and humidity from in-flight tests. Recommendations based on first-hand data were made to maintain the relative humidity in the cabin below 40%, ensure wind speed remains within the range of 0–1 m/s, and regulate the temperature between 25–27 °C (for summer) and 22–27 °C (for winter). The current estimated cabin air supply rate generally complies with the requirements of international standards. Additionally, potential carcinogenic and non-carcinogenic risks associated with formaldehyde, benzene, tetrachloroethylene, and naphthalene were calculated. The sorted data of in-flight tests and the evaluation of the subjective perception of the occupants provide an evaluation of current cabin thermal comfort and air quality status, which can serve as a reference for optimizing indoor environmental quality in future generations of civil aircraft cabins.
Open AccessA Review of In-Flight Thermal Comfort and Air Quality Status in Civil Aircraft Cabin Environments
The civil aircraft cabin is enclosed and highly occupied, making it susceptible to a decline in indoor environmental quality. The environmental quality of civil aircraft cabins not only depends on objective factors such as temperature, relative humidity, and the presence of air pollutants such as carbon dioxide (CO2), carbon monoxide (CO), ozone (O3), particle matter (PM), and volatile organic compounds (VOCs) but also the subjective factors pertaining to the perceptions and health symptoms of passengers and crew. However, few studies have thoroughly examined the air quality and thermal comfort parameters that are measured during in-flight testing in airplane cabins, as well as the passengers’ subjective perceptions. In order to evaluate the in-flight thermal comfort and air quality status, this study conducted a review of the recent literature to compile data on primary categories, standard limits, and distribution ranges of in-flight environmental factors within civil aircraft cabins. Following a search procedure outlined in this paper, 54 papers were selected for inclusion. Utilizing the Monte Carlo method, the Predicted Mean Vote (PMV) distributions under different exercise intensities and clothing thermal resistance were measured with the in-cabin temperature and humidity from in-flight tests. Recommendations based on first-hand data were made to maintain the relative humidity in the cabin below 40%, ensure wind speed remains within the range of 0–1 m/s, and regulate the temperature between 25–27 °C (for summer) and 22–27 °C (for winter). The current estimated cabin air supply rate generally complies with the requirements of international standards. Additionally, potential carcinogenic and non-carcinogenic risks associated with formaldehyde, benzene, tetrachloroethylene, and naphthalene were calculated. The sorted data of in-flight tests and the evaluation of the subjective perception of the occupants provide an evaluation of current cabin thermal comfort and air quality status, which can serve as a reference for optimizing indoor environmental quality in future generations of civil aircraft cabins.
- Open Access
- 28 June 2024
- Published by Elsevier in Energy and Buildings
- Vol. 318
Comparison of the environmental, energy, and thermal comfort performance of air and radiant cooling systems in a zero-energy office building in Singapore
- 28 June 2024
- Published by Elsevier in Energy and Buildings
- Vol. 318
Open AccessComparison of the environmental, energy, and thermal comfort performance of air and radiant cooling systems in a zero-energy office building in Singapore
- Open Access
- 28 March 2024
- Published by Elsevier in Building and Environment
- Vol. 256
PIV experimental study on natural convective flows at high Rayleigh numbers in industrial buildings
- 28 March 2024
- Published by Elsevier in Building and Environment
- Vol. 256
Open AccessPIV experimental study on natural convective flows at high Rayleigh numbers in industrial buildings
- Open Access
- 2 August 2023
- Published by Elsevier in Building and Environment
- Vol. 243
Energy savings and thermal comfort in a zero energy office building with fans in Singapore
- 2 August 2023
- Published by Elsevier in Building and Environment
- Vol. 243
Open AccessEnergy savings and thermal comfort in a zero energy office building with fans in Singapore
- Open Access
- 1 August 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (8)
Turbulence characterization of instantaneous airflow above passengers with different air distribution systems in a commercial airliner cabin
The environment inside airliner cabins has attracted increasing attention. Instantaneous airflow, as one of the fundamental parameters of airflow field, affects aspects of the airliner cabin environment such as occupant comfort and airborne disease transmission. This study evaluated the characteristics of instantaneous airflow in airliner cabins with different ventilation systems (mixing ventilation and displacement ventilation) and focused on the region above passengers' heads, where complex turbulence characteristics are found. This investigation used ultrasonic anemometers for measurements at ten selected points above passengers' heads. The energy ratio on the low-frequency scale with mixing ventilation was greater than that with displacement ventilation. The instantaneous airflow with mixing ventilation was close to that of natural wind, while the instantaneous airflow with displacement ventilation was close to that of mechanical wind. Compared with mixing ventilation, displacement ventilation produced a smaller vortex length and a shorter residence time. Moreover, there was no long-term vortex in the flow field under displacement ventilation, and therefore, pollutants would be discharged more quickly from the cabin. In addition, this paper distinguishes the spatial and temporal turbulence scales of mixing and displacement ventilation, thus providing a reference for the selection of grid size and time steps in computational fluid dynamics simulations.
- 1 August 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (8)
Open AccessTurbulence characterization of instantaneous airflow above passengers with different air distribution systems in a commercial airliner cabin
The environment inside airliner cabins has attracted increasing attention. Instantaneous airflow, as one of the fundamental parameters of airflow field, affects aspects of the airliner cabin environment such as occupant comfort and airborne disease transmission. This study evaluated the characteristics of instantaneous airflow in airliner cabins with different ventilation systems (mixing ventilation and displacement ventilation) and focused on the region above passengers' heads, where complex turbulence characteristics are found. This investigation used ultrasonic anemometers for measurements at ten selected points above passengers' heads. The energy ratio on the low-frequency scale with mixing ventilation was greater than that with displacement ventilation. The instantaneous airflow with mixing ventilation was close to that of natural wind, while the instantaneous airflow with displacement ventilation was close to that of mechanical wind. Compared with mixing ventilation, displacement ventilation produced a smaller vortex length and a shorter residence time. Moreover, there was no long-term vortex in the flow field under displacement ventilation, and therefore, pollutants would be discharged more quickly from the cabin. In addition, this paper distinguishes the spatial and temporal turbulence scales of mixing and displacement ventilation, thus providing a reference for the selection of grid size and time steps in computational fluid dynamics simulations.