Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Soumya Ranjan Das has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multilayer perceptron neural network approach for power quality improvement in a grid integrated PV and electric vehicle systems

    by Soumya Ranjan Das, Jayalakshmi Narayana Sabhahit, K. Abhimanyu Kumar Patro, Devi Prasad Acharya, Asit Mohanty, Erdem Cuce

    Recently, there has been an increase in the grid integration of electric vehicles (EVs) and solar photovoltaic (PV) systems, primarily driven by two goals: lowering energy costs and decreasing emissions. Numerous research studies have concentrated on the separate effects of integrating PVs and EVs into the grid. Nevertheless, it is important to recognize that as the adoption of PVs and EVs continues to grow, the supply grid will face the cumulative effects of PV and EV integration on power quality (PQ) challenges. To provide a comprehensive understanding, this study examines the joint impact of PVs and EVs on PQ aspects in detail. This study has indicated that EVs and PVs alone can adversely impact grid reliability and PQ because of the variable character of PV source and the unpredictability of EV demand. But multiple research efforts have shown that coordination between PVs and EVs can help to alleviate certain problems that arise from their individual integration. This study demonstrates PQ enhancement in a grid system integrated with PV and EV using a multilayer perceptron neural network (MLPNN) approach. In the system with PV integration, the GWO-ANFIS, MPPT technique is employed for optimizing power extraction. Under balanced non-linear loading conditions, simulation results show that the THD is initially 25.97% without compensation, then decreases to 12.57% with a shunt passive filter (SPF), 3.37% with the application of recursive least squares (RLS), and 1.37% with MLPNN. With much lower THD and quicker convergence, the suggested MLPNN-based controller exhibits improved harmonic mitigation. A comparison between the proposed and existing methods are drawn using the MATLAB/Simulink platform.

  • Open Access

    Multi-domain gate-engineered pentacene OFET for hydrogen detection: design, modeling, and simulation

    by Pramod Martha, Soumya Ranjan Das, Bhaskar Awadhiya, Yashwanth N, Amit Kumar Goyal, Praveen Kumar, Sukanta Kumar Tulo

    This research work addresses key challenges in organic field-effect transistor (OFET)-based gas sensors by proposing a compact differential hydrogen ( H 2 ) sensor based on a pentacene OFET with a bottom gate extended in both in-plane and out-of-plane (IP-OP) directions. The IP-OP extended architecture enhances hydrogen sensitivity while reducing footprint and environmental susceptibility, and the differential configuration suppresses common-mode effects, improving robustness against environmental fluctuations. Platinum-coated vias in a 10 μ m-thick parylene-C layer selectively expose the gate while protecting the pentacene channel from environmental effects. The proposed sensor is designed, analytically modeled, and validated using previously reported experimental results. The effects of incoming H 2 gas pressure on charge transfer, the highest occupied molecular orbital and the lowest unoccupied molecular orbital energy levels, and the corresponding drain current characteristics are analyzed, and a Verilog-A model of the sensor is developed for circuit-level integration and differential amplifier performance evaluation. A 16% change in the platinum (Pt) gate work function over 0 to 0.5 torr hydrogen pressure ( P H 2 ) shifts the P-OFET threshold voltage ( V TH ) from − 0.16 V to − 1.5 V. The drain current varies from − 1.35 mA at zero P H 2 to − 0.66 mA at P H 2 = 0.5 torr, with a relative change greater than 50% at V GS = V DS = − 3 V. In the differential amplifier, one leg contains a P-OFET with an extended gate in the IP-OP direction, while the other features a P-OFET covered with Parylene-C to prevent hydrogen-induced current variations. The load resistance ( R L ) is optimized to 700 Ω for maximum gain, resulting in a V out range of 0 to 2.83 V at room temperature. The designed sensor occupies a compact area of 5.5 mm × 6 mm, demonstrating its suitability for early hydrogen leak detection in automotive and industrial applications.

  • Open Access

    Teaching learning based optimization algorithm for effective analysis of power quality using dynamic voltage restorer

    by Soumya Ranjan Das, Surender Reddy Salkuti

    In this study, the load voltage is dynamically restored utilising the dynamic voltage restorer (DVR) using the voltage injection approach. The injected voltage is generated using a voltage-source inverter (VSI), which is necessary to correct for the utility network's sag and swell characteristics voltage. The restoration process is dependent on the condition and quality of the utility system, i.e., it injects energy into the external system for the duration of voltage sag, and during voltage swell, energy is absorbed by the compensator from the external system, causing an rise in dc link voltage, which is connected across the VSI. In this study two different controllers are employed based on a learning based optimized algorithm. The simulation results are shown using two different controllers and the performance of the proposed controller is found to be a better one.


  • Open Access

    Teaching learning optimization technique FOPID controlled Cuk and SEPIC converter-based PF rectification

    by Alok Kumar Mishra, Soumya Ranjan Das, Nimay Chandra Giri, Sangram Kishore Routray, Fathy Abdelaziz Syam, Ehab S. Elwakil

    The foremost cause of harmonic contamination is the ample utilization of loads of non-linear type such as static power converters. Because of this load, the input power factor (PF) decreases heavily as they draw a current of non-sinusoidal in nature. This article gives a general presentation investigation of two PF rectification (PFR) converter (PFRC) geographies: Cuk type and single-ended primary-inductance converter or SEPIC type converter. The average current control (ACC) technique is utilized here. Notwithstanding, for control of output voltage, techniques like conventional proportional integral derivative controller (PIDC) or fractional order proportional integral derivative controller (FOPIDC) are used, and the gains of the controller are calculated using a novel teaching learning optimization technique (TLOT), considering integral time absolute error (ITAE). The analysis of both PFRC acted in Simulink/MATLAB and the estimated converters are studied under consistent and dynamic state conditions. The FOPIDC Cuk PFRC is providing 2.97% of THD compared to other converters.


  • Fuzzy Controller Designed-Based Multilevel Inverter for Power Quality Enhancement

    by Soumya Ranjan Das, Alok Kumar Mishra, Arun Kumar Sahoo, Ambika Prasad Hota, Wattana Viriyasitavat, Norah Saleh Alghamdi, Gaurav Dhiman

    The use of renewable energy seems to be vital as the demand for electricity power rises quickly. But the traditional electric power grid is not able to face the challenges raised by the modern power system. As the distributed generation (DGs) become more and more integrated into the grid, the power quality (PQ) and grid stability of the system will deteriorate. Therefore, to upgrade the existing scenario, a new concept of smart grid (SG) is evolved. This modern power grid infrastructure is used for improved efficiency and reliability through different controlling infrastructures and modern energy management techniques. Many grid interfacing devices (GID) are employed to improve the PQ by reducing the harmonics, enhancing the power factor and managing the imaginary power. In this literature, a modified pack U-Cell (MPUC) multilevel inverter (MLI) topology is proposed. The controlling strategy used in MPUC is of instantaneous active and reactive current technique for reference current generation and the adaptive fuzzy hysteresis current controller (AFHCC) is employed for switching signal. The regulation of DC link is controlled using different types of fuzzy logic controller (FLC).The response of MLI with different load and supply conditions is evaluated and authenticated through proper design in MATLAB/Simulink environment, and the results are validated using a real-time environment.


  • DT-CWT and type-2 fuzzy-HSAPF for harmonic compensation in distribution system

    by Alok Kumar Mishra, Pradip Kumar Nanda, Prakash Kumar Ray, Soumya Ranjan Das, Akshaya Kumar Patra


  • Open Access

    Overshoot Reduction Using Adaptive Neuro-Fuzzy Inference System for an Autonomous Underwater Vehicle

    by Narayan Nayak, Soumya Ranjan Das, Tapas Kumar Panigrahi, Himansu Das, Soumya Ranjan Nayak, Krishna Kant Singh, S. S. Askar, Mohamed Abouhawwash

    In this paper, an adaptive depth and heading control of an autonomous underwater vehicle using the concept of an adaptive neuro-fuzzy inference system (ANFIS) is designed. The autonomous underwater vehicle dynamics have six degrees of freedom, which are highly nonlinear and time-varying. It is affected by environmental effects such as ocean currents and tidal waves. Due to nonlinear dynamics designing, a stable controller in an autonomous underwater vehicle is a difficult end to achieve. Fuzzy logic and neural network control blocks make up the proposed control design to control the depth and heading angle of autonomous underwater vehicle. The neural network is trained using the back-propagation algorithm. In the presence of noise and parameter variation, the proposed adaptive controller’s performance is compared with that of the self-tuning fuzzy-PID and fuzzy logic controller. Simulations are conducted to obtain the performance of both controller models in terms of overshoot, and the rise time and the result of the proposed adaptive controller exhibit superior control performance and can eliminate the effect of uncertainty.